TSH188 Ultra High Sensitivity Hall Effect Latch TO-92S Pin Definition: 1. VCC 2. GND 3. Output SOT-23 Pin Definition: 1. VCC 2. Output 3. GND Description TSH188 Hall-effect sensor is a temperature stable, stress-resistant sensor. Superior high-temperature performance is made possible through a dynamic offset cancellation that utilizes chopper-stabilization. This method reduces the offset voltage normally caused by device over molding, temperature dependencies, and thermal stress. TSH188 includes the following on a single silicon chip: voltage regulator, Hall voltage generator, small-signal amplifier, chopper stabilization, Schmitt trigger. Advanced DMOS wafer fabrication processing is used to take advantage of low-voltage requirements, component matching, very low input-offset errors, and small component geometries. This device requires the presence of both south and north polarity magnetic fields for operation. In the presence of a south polarity field of sufficient strength, the device output sensor on, and only switches off when a north polarity field of sufficient strength is present Features ● ● ● ● ● Ordering Information o 100% tested at 125 C Temperature compensation function Chopper stabilized amplifier stage. Optimized for BLDC motor applications. Reliable and low shifting on high Temp condition. TSH188CT B0G TSH188CT A3G TSH188CX RFG Package Packing TO-92S TO-92S SOT-23 1Kpcs / Bulk Bag 2Kpcs / Ammo 3Kpcs / 7” Reel Note: “G” denote for Halogen Free Product Application ● ● ● ● ● ● Part No. High temperature Fan motor 3 phase BLDC motor application Speed sensing, Position sensing, Current sensing Revolution counting Solid-State Switch Linear/Angular Position Detection Absolute Maximum Rating (Ta = 25oC unless otherwise noted) Characteristics Supply voltage Output Voltage Reverse voltage Magnetic flux density Output current Operating Temperature Range Storage temperature range Maximum Junction Temp Thermal Resistance - Junction to Ambient Thermal Resistance - Junction to Case Package Power Dissipation Note: Do not apply reverse voltage to VCC and VOUT Limit Value Unit VCC VOUT VCC/OUT 28 28 -28 Unlimited 50 V V V Gauss mA o C IOUT TOPR -40 to +125 o -55 to +150 TSTG C o 150 TJ C 206 TO-92S o θJA C/W 543 SOT-23 148 TO-92S o θJC C/W 410 SOT-23 606 TO-92S PD mW 230 SOT-23 Pin, It may be caused for Miss function or damaged device. 1/8 Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch Block Diagram Typical Application Circuit C1:10nF C2:1nF R1:1KΩ Electrical Specifications (DC Operating Parameters:TA=+25oC,VCC=12V) Parameters Test Conditions Min Typ Max Units 2.5 -- 24 V Supply Voltage Operating Supply Current B<BOP -- -- 5 mA Output Saturation Voltage IOUT=20mA,B>BOP -- -- 400 mV Output Leakage Current IOFF B<BRP, VOUT = 12V -- -- 10 uA -- 69 -- kHz Internal Oscillator Chopper Frequency Output Rise Time RL=1.1KΩ, CL=20pF -- 0.04 0.45 uS Output Fall Time RL=820Ω; CL=20pF -- 0.18 0.45 uS ESD HBM 4 -- -- KV Operate Point 5(-25) -- 25(-5) Gauss Release Point -25(5) -- -5(25) Gauss -- 30 -- Gauss Hysteresis Note: 1G (Gauss) = 0.1mT (millitesta) 2/8 Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch Output Behavior versus Magnetic Pole o DC Operating Parameters: TA = -40 to 125 C, VCC = 2.5~24V Parameter Test condition OUT (TO-92S) OUT (SOT-23) North pole B>BOP Open(Hi) Low South pole B<BRP Low Open(Hi) TO-92S OUT=Hi (Pull-up Voltage) SOT-23 OUT=Low (VDSon) OUT=Low (VDSon) 3/8 OUT=Hi (Pull-up Voltage) Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch Characteristic Performance Figure 1. Supply Voltage vs. Flux Density Figure 2. Temperature vs. Flux Density Figure 3. Supply Current vs. Temperature Figure 4. Supply Current vs. Supply Voltage Figure 5. Supply Voltage vs. Saturation Voltage Figure 6. Saturation Voltage vs. Temperature 4/8 Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch Characteristic Performance Figure 7. Supply Voltage vs. Leakage Current Figure 8. Temperature vs. Power Dissipation Figure 9. Supply Voltage vs. Internal Frequency Figure 10. Temperature vs. Internal Frequency 5/8 Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch TO-92S Mechanical Drawing Unit: Millimeters Marking Diagram 188 Y WW = Device Code = Year Code = Week Code (01~52) 6/8 Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch SOT-23 Mechanical Drawing Unit: Millimeters Marking Diagram 188 WW = Device Code = Week Code Table week code week code week code week code 1 OA 14 ON 27 PA 40 PN 2 OB 15 OO 28 PB 41 PO 3 OC 16 OP 29 PC 42 PP 4 OD 17 OQ 30 PD 43 PQ 7/8 5 OE 18 OR 31 PE 44 PR 6 OF 19 OS 32 PF 45 PS 7 OG 20 OT 33 PG 46 PT 8 OH 21 OU 34 PH 47 PU 9 OI 22 OV 35 PI 48 PV 10 OJ 23 OW 36 PJ 49 PW 11 OK 24 OX 37 PK 50 PX 12 OL 25 OY 38 PL 51 PY 13 OM 26 OZ 39 PM 52 PZ Version: C13 TSH188 Ultra High Sensitivity Hall Effect Latch Notice Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify TSC for any damages resulting from such improper use or sale. 8/8 Version: C13