High Sensitivity Omni-Polar Hall Effect Switch
TO-92S
Pin Definition:
1. VCC
2. GND
3. Output
SOT-23
Pin Definition:
1. VCC
2. Output
3. GND
Description
TSH253 Hall-effect sensor is a temperature stable, stress-resistant switch. Superior high-temperature
performance is made possible through a dynamic offset cancellation that utilizes chopper-stabilization. This
method reduces the offset voltage normally caused by device over molding, temperature dependencies, and
thermal stress. TSH253 includes the following on a single silicon chip: voltage regulator, Hall voltage generator,
small-signal amplifier, chopper stabilization, Schmitt trigger, open-drain output. Advanced CMOS wafer fabrication
processing is used to take advantage of low-voltage requirements, component matching, very low input-offset
errors, and small component geometries.
Features
●
●
●
●
●
●
CMOS Hall IC Technology
Solid-State Reliability much better than reed switch
Omni polar output switches with absolute value of
North or South pole from magnet
Operation down to 1.8 V and Max at 6V.
High Sensitivity for reed switch replacement
ESD HBM ±4KV Min
Ordering Information
Part No.
TSH253CT B0G
TSH253CX RFG
Package
Packing
TO-92S
SOT-23
1Kpcs / Bulk Bag
3Kpcs / 7” Reel
Note: “G” denote for Halogen Free Product
Application
●
●
●
●
●
Solid state switch, Revolution counter
Lid close sensor for power supply devices
Magnet proximity sensor for reed switch
replacement in high duty cycle applications.
Safety Key on sporting equipment
Speed sensor, Position Sensor, Rotation Sensor
Absolute Maximum Rating (Ta = 25oC unless otherwise noted)
Characteristics
Limit
Value
Unit
Supply voltage
Output Voltage
Reverse voltage
Magnetic flux density
Output current
Operating Temperature Range
VCC
VOUT
VCC/OUT
6
6
-0.3
Unlimited
1
V
V
V
Gauss
mA
o
C
IOUT
TOPR
-40 to +85
o
-55
to +150
Storage temperature range
TSTG
C
o
150
Maximum Junction Temp
TJ
C
206
TO-92S
o
Thermal Resistance - Junction to Ambient
θJA
C/W
543
SOT-23
148
TO-92S
o
Thermal Resistance - Junction to Case
θJC
C/W
410
SOT-23
606
TO-92S
Package Power Dissipation
PD
mW
230
SOT-23
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximumrated conditions for extended periods may affect device reliability.
1/8
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
Block Diagram
Note: Static sensitive device; please observe ESD precautions. Reverse VDD protection is not included. For
reverse voltage protection, a 100Ω resistor in series with VDD is recommended.
Typical Application Circuit
C1:10nF
C2:100pF
R1:10KΩ
Electrical Specifications (DC Operating Parameters:TA=+25oC,VCC=5V)
Parameters
Test Conditions
Min
Typ
Max
Units
1.8
--
6
V
Supply Voltage
Operating
Supply Current
Average
--
2.6
6.0
mA
Output Low Voltage
IOUT=0.5mA
--
--
200
mV
Output Leakage Current
IOFF B<BRP, VOUT = 3V
--
--
10
uA
Output Rise Time
RL=10kΩ, CL =20pF
--
--
0.45
uS
Output Fall Time
RL=10kΩ; CL =20pF
--
--
0.45
uS
Electro-Static Discharge
HBM
4
--
--
KV
2/8
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
Magnetic Specifications (TSH253CT)
Parameter
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Operating
Point
BOPS
S pole to branded side, B > BOP, Vout On
30
60
Gauss
BOPN
N pole to branded side, B > BOP, Vout On
-60
-30
Gauss
5
25
Gauss
Release
Point
BRPS
S pole to branded side, B < BRP, Vout Off
BRPN
N pole to branded side, B < BRP, Vout Off
-25
Hysteresis
BHYS
|BOPx - BRPx|
5
-5
Gauss
Gauss
Note: 1G (Gauss) = 0.1mT (millitesta)
Magnetic Specifications (TSH253CX)
Parameter
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Operating
Point
BOPS
N pole to branded side, B > BOP, Vout On
--
30
60
Gauss
BOPN
S pole to branded side, B > BOP, Vout On
-60
-30
--
Gauss
Release
Point
BRPS
N pole to branded side, B < BRP, Vout Off
5
25
--
Gauss
BRPN
S pole to branded side, B < BRP, Vout Off
--
-25
-5
Gauss
Hysteresis
BHYS
|BOPx - BRPx|
--
5
--
Gauss
Note: 1G (Gauss) = 0.1mT (millitesta)
Output Behavior versus Magnetic Pole
o
DC Operating Parameters: TA = -40 to 125 C, VCC = 1.8V ~ 6V
Parameter
Test condition
OUT
South pole
B<Bop[(-60)~(-5)]
Low
Null or weak magnetic field
B=0 or B < BRP
Open(Pull-up Voltage)
North pole
B>Bop(60~5)
Low
TO-92S
SOT-23
3/8
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
Characteristic Performance
Figure 1. Supply Voltage vs. Flux Density
Figure 2. Temperature vs. Flux Density
Figure 3. Supply Current vs. Temperature
Figure 4. Supply Current vs. Supply Voltage
Figure 5. Output Saturation Voltage vs.
Supply Voltage
Figure 6. Output Saturation Voltage vs.
Temperature
4/8
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
Characteristic Performance
Figure 7. Output Leakage Current vs.
Supply Voltage
Figure 8. Power Dissipation vs. Temperature
5/8
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
TO-92S Mechanical Drawing
Unit: Millimeters
Marking Diagram
253
Y
WW
= Device Code
= Year Code (3=2013, 4=2014….)
= Week Code (01~52)
6/8
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
SOT-23 Mechanical Drawing
Unit: Millimeters
Marking Diagram
253
WW
= Device Code
= Week Code Table
week
code
week
code
week
code
week
code
1
OA
14
ON
27
PA
40
PN
2
OB
15
OO
28
PB
41
PO
3
OC
16
OP
29
PC
42
PP
4
OD
17
OQ
30
PD
43
PQ
7/8
5
OE
18
OR
31
PE
44
PR
6
OF
19
OS
32
PF
45
PS
7
OG
20
OT
33
PG
46
PT
8
OH
21
OU
34
PH
47
PU
9
OI
22
OV
35
PI
48
PV
10
OJ
23
OW
36
PJ
49
PW
11
OK
24
OX
37
PK
50
PX
12
OL
25
OY
38
PL
51
PY
13
OM
26
OZ
39
PM
52
PZ
Version: C13
TSH253
High Sensitivity Omni-Polar Hall Effect Switch
Notice
Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf,
assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, to
any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of
sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty,
relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose,
merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify TSC for any damages resulting from such improper use or sale.
8/8
Version: C13