HONEYWELL 141PC05G

Interactive Catalog Replaces Catalog Pages
Honeywell Sensing and Control has replaced
the PDF product catalog with the new
Interactive Catalog. The Interactive Catalog is
a power search tool that makes it easier to find
product information. It includes more
installation, application, and technical
information than ever before.
Sensing and Control
Honeywell Inc.
11 West Spring Street
Freeport, Illinois 61032
Click this icon to try the new
Interactive Catalog.
Pressure Sensors
Absolute, Differential, Gage, Vacuum Gage/Amplified
140PC Series
FEATURES
1 PCB terminals on opposite side from
the ports
1 Fully signal conditioned
140PC SERIES PERFORMANCE CHARACTERISTICS at 8.0 ±0.01 VDC
Excitation, 25°C
Typ.
Max.
Units
Excitation
7.00
8.00
16.0
VDC
Supply Current
---
8.00
20.0
mA
Current Sourcing Output
---
---
10
mA
Null Offset (141/142PC)
0.95
1.00
1.05
V
Null Offset (143PC) *
3.45
3.50
3.55
V
Null Offset
142PC15A @ 2 psia
142PC30A @ 2 psia
1.62
1.28
1.67
1.33
1.72
1.38
V
V
Output at Full Pressure
5.90
6.00
6.10
V
Span† (141/142PC)
4.95
5.00
5.05
V
Span† (143PC) *
---
5.00
---
V
Span
142PC15A (2 to 15 psia)
142PC30A (2 to 30 psia)
4.28
4.62
4.33
4.67
4.48
4.72
V
V
Ratiometricity Error
7 to 8 V or 8 to 9 V
9 to 12 V
-----
±0.50
±2.00
-----
% Span
Stability over One Year
---
±0.50
---
% Span
Response Time
---
---
1.00
msec
Common Mode Pressure * *
---
---
40
psi
Weight
---
28
---
grams
Short Circuit Protection
Output may be shorted indefinitely to ground
Output Ripple
None, DC device
Ground Reference
Supply and output are common
Amplified
Min.
*Positive and negative pressure measurement.
**Higher common mode pressures possible if sensor is not used over entire operating temperature range.
†Span is defined as the algebraic difference between end points. Please note: actual output is 1 V to 6 V (at 8.00
±0.01 VDC). Span is then 5V.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
−40° to +85°C (−40° to +185°F)
Storage Temperature
−55° to +125°C (−67° to +257°F)
Compensated Temperature
−18° to +63°C (0° to +145°F)
Shock
MIL-STD-202, Method 213 (50 g, half sine, 6 msec)
Vibration
MIL-STD-202, Method 204 (10 to 2000 Hz at 10 g)
Media
P2 port Wetted materials; polyester housing, epoxy
adhesive, silicon, borosilicate glass, and silicon-toglass bond*
P1 port Dry gases only
*Liquid media containing some highly ionic solutions could potentially neutralize the chip-to-glass tube
bond.
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
37
Pressure Sensors
Absolute, Differential, Gage, Vacuum Gage/Amplified
140PC Series
140PC SERIES ORDER GUIDE, VACUUM GAGE TYPE
Shift
Null, Sensitivity, Combined**
25 to 5°
25 to 45°C
Linearity, B.F.S.L.
P2 > P1
P2 < P1
Repeatability
& Hysteresis
%Span
Typ.
25 to −18°
25 to +63°C
25 to −40°
25 to 85°C
Max.
Max.
Max.
Sensitivity
V/psi
Overpressure
psi
Max.
Max.
Max.
---
±1.50
---
---
5.000
20
---
±0.75
±0.30
0-−5
±0.50
---
±1.00
±2.00
1.000
20
---
±0.75
±0.25
0-−15
±0.50
---
±1.00
±2.00
0.333
45
---
±0.40
±0.15
Catalog
Listing
Pressure
Range
psi
Typ.
141PC01G
0-−1
141PC05G
141PC15G
%Span
140PC SERIES ORDER GUIDE, GAGE TYPE
Shift
Null, Sensitivity, Combined**
25 to 5°
25 to 45°C
Linearity, B.S.F.L.
Max.
Max.
Repeatability
& Hysteresis
%Span
Typ.
20
±0.75
---
±0.30
25 to −18°
25 to +63°C
25 to −40°
25 to 85°C
Max.
Max.
Max.
Sensitivity
V/psi
Overpressure
psi
Max.
---
±1.50
---
---
5.000
Catalog
Listing
Pressure
Range
psi
Typ.
142PC01G
0-1
P2 > P1
P2 < P1
%Span
142PC02G
0-2
---
±1.50
---
---
2.500
20
±0.75
---
±0.30
142PC05G
0-5
±0.50
---
±1.00
±2.00
1.000
20
±1.50
---
±0.25
142PC15G
0-15
±0.50
---
±1.00
±2.00
0.333
45
±0.75
---
±0.15
142PC30G
0-30
±0.50
---
±1.00
±2.00
0.167
60
±0.75
---
±0.15
143PC03G
±2.5
---
---
±1.00
±1.50
1.000
20
±0.75
---
±0.25
143PC05G
±5
---
---
±1.00
±1.50
0.500
30
±0.75
---
±0.15
143PC15G
±15
---
---
±1.00
±1.50
0.177
50
±0.75
---
±0.15
140PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE
Shift
Null, Sensitivity, Combined**
25 to 5°
25 to 45°C
Linearity, B.F.S.L.
P2 > P1
P2 < P1
Repeatability
& Hysteresis
%Span
Typ.
25 to −18°
25 to +63°C
25 to −40°
25 to 85°C
Max.
Max.
Max.
Sensitivity
V/psi
Overpressure
psi
Max.
---
±1.50
---
---
5.000
0-2
---
±1.50
---
---
142PC05D
0-5
±0.50
---
±1.00
142PC15D
0-15
±0.50
---
±1.00
142PC30D
0-30
±0.50
---
±1.00
143PC03D
±2.5
---
---
±1.00
±1.50
1.000
20
±0.75
±0.40
±0.25
143PC05D
±5
---
---
±1.00
±1.50
0.500
30
±0.75
±0.40
±0.15
143PC15D
±15
---
---
±1.00
±1.50
0.177
50
±0.75
±0.40
±0.15
Catalog
Listing
Pressure
Range
psi
Typ.
142PC01D
0-1
142PC02D
%Span
Max.
Max.
20
±0.75
±0.40
±0.30
2.500
20
±0.75
±0.40
±0.30
±2.00
1.000
20
±1.50
±0.75
±0.25
±2.00
0.333
45
±0.75
±0.40
±0.15
±2.00
0.167
60
±0.75
±0.40
±0.15
140PC SERIES ORDER GUIDE, ABSOLUTE TYPE*
Shift
Null, Sensitivity, Combined**
Linearity, B.F.S.L.
25 to −18°
25 to +63°C
25 to −40°
25 to 85°C
Max.
Max.
Max.
Sensitivity
V/psi
Overpressure
psi
Max.
Max.
Max.
Repeatability
& Hysteresis
%Span
Typ.
±0.50
---
±1.00
±2.00
0.333
45
---
±0.40
±0.15
±0.50
---
±1.00
±2.00
0.167
60
---
±0.40
±0.15
25 to 5°
25 to 45°C
Catalog
Listing
Pressure
Range
psia
Typ.
142PC15A
0-15
142PC30A
0-30
P2 > P1
P2 < P1
%Span
*Tested at 2 psia reference
**% Span specification applies to each shift independently. (Null, sensitivity, or combined).
38
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Pressure Sensors
Absolute, Differential, Gage, Vacuum Gage/Amplified
ELECTRICAL CONNECTION
Voltage Excitation
NULL AND SENSITIVITY
TEMPERATURE SHIFT
Amplified pressure sensors are 100%
tested to insure that the maximum null
and sensitivity temperature shift does not
exceed the specification. The diagram
below illustrates how null and sensitivity
shift relates to temperature. Note that the
maximum shift occurs at temperature extremes. Therefore, if a sensor is not ex-
140PC Series
posed to the entire temperature range,
the maximum null and sensitivity shift will
actually be less than the value specified.
This diagram indicates the temperature
shift pertaining to a few listings. Maximum
null and sensitivity shift varies from listing
to listing.
Amplified
NOTES
1. Terminals are labeled on the sensor.
2. Input and output share a common
ground.
3. RL must be greater than or equal to
3000 ohms.
INTERNAL CIRCUITRY
RATIOMETRICITY
SCALING OF 140PC SERIES SENSORS WITH 8V EXCITATION
Ratiometricity refers to the output voltage
being directly proportional to the supply
voltage. 140PC sensors in this catalog are
calibrated at 8 VDC supply voltage to provide a 1-6 volt (5V Span) output swing. For
example, if supply increases by 50% to 12
VDC, the output voltage increases by
50% to 1.5-9 volts (7.5 V Span).
142PC15A
Absolute
142PC30A
Absolute
VO J 1 V at 0 psia & 6 V at 30 psia
142PC15G
Gage
VO J 1 V at 0 psig & 6 V at 15 psig
141PC15G
Vacuum Gage
VO J 1 V at 0 psig & 6 V at −15 psig
143PC05D
Differential
VO J 1 V at −5 psig & 6 V at 5 psig
143PC15D
Differential
VO J 1 V at −15 psig & 6 V at 15 psig
NOTE
The output is not perfectly ratiometric.
See specifications for the degree of error.
VO J 1 V at 0 psia & 6 V at 15 psia
NOTE: 141PC sensors are scaled for vacuum pressure on P2.
142PC sensors are scaled for greater pressure on the P2 side of the chip. Input pressures on
absolute units are applied to the P1 port.
Other scalings available upon request.
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
39
Pressure Sensors
Absolute, Differential, Gage, Vacuum Gage/Amplified
140PC Series
MOUNTING DIMENSIONS (For reference only)
Dimensions shown apply to Differential and Absolute versions. Gage units are identical, except the P1 port is absent.
140PC CONSTRUCTION
40
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada