140PC...-PCB Series

140PC...-PCB Series
Signal conditioned precision pressure transducers
FEATURES
· 1 to 150 psi absolute, gage or
differential pressure
· 1...6 V output
· Output ratiometric to supply voltage
· Precision temperature compensated
and calibrated
· EMC-proof
SERVICE
Non-corrosive, non-ionic working fluids,
such as dry air and dry gases
ELECTRICAL CONNECTION
SPECIFICATIONS
Maximum ratings
Supply voltage
Maximum load current
Source
Sink
Temperature limits
Storage
Operating
Compensated
Lead temperature
(10 sec. soldering)
Humidity limits
Pressure inlets only
7...16 V
10 mA
5 mA
-55 to 100°C
-40 to 85°C
0 to 70°C
300°C
+Vs
140PC...-PCB
7 V to 16 V
(NOM 8.00 V)
Vout
V
-Vs
0 - 98 %RH
1
Proof pressure
All 1 psi, 3 psi, 5 psi devices
All 15 psi devices
All 30 psi devices
All 100 psi devices
All 150 psi devices
E / 11554 / A
20 psi
30 psi
60 psi
150 psi
200 psi
1/3
www.first-sensor.com
www.sensortechnics.com
140PC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
(unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
vacuum gage devices2
differential devices3
absolute devices3
pressure/vacuum devices3
Zero pressure offset
Full scale span4
Min.
141PC01G-PCB
141PC05G-PCB
141PC15G-PCB
141PC30G-PCB
141PC100G-PCB
142PC01D-PCB
142PC05D-PCB
142PC15D-PCB
142PC30D-PCB
142PC100D-PCB
142PC150D-PCB
142PC15A-PCB
142PC30A-PCB
142PC100A-PCB
143PC01D-PCB
143PC03D-PCB
143PC05D-PCB
143PC15D-PCB
141PC.../142PC...-PCB
143PC...-PCB
141PC.../142PC...-PCB
143PC...-PCB
Full scale output
Output at lowest specified pressure
Non-linearity and hysteresis (BSL)5
Thermal effects6
Combined offset and span (0 to 70°C)
Long term stability7
-1
-5
-15
-30
-100
0
0
0
0
0
0
0
0
0
-1
-2.5
-5
-15
0.95
3.45
4.95
2.45
5.90
Max.
1.00
3.50
5.00
2.50
6.00
0
0
0
0
0
1
5
15
30
100
150
15
30
100
1
2.5
5
15
1.05
3.55
5.05
2.55
6.10
143PC...-PCB
1.00
all 1 psi devices
all others
0.1
±1.5
±0.5
±0.1
Response time (10 to 90%)
Current consumption
Radiated, radio frequency electromagnetic
field immunity (RFI) EN6100-4-3 grade 3,
80 to 1000 MHz,
80 % AMC (1 KHz)
Typ.
0.1
4.5
10
0.5
±3.0
±1.0
Unit
p si g
(vacuum)
psid(g)
p si a
psid(g)
V
%FSO
ms
mA
V/m
Specification notes:
1. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
2. The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the
output signal increases when pressure is applied to port B relative to port A.
3. The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to port A, relative
to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.
4. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
5. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
6. Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.
7. Change in output after one year or 1 million pressure cycles.
E / 11554 / A
2/3
www.first-sensor.com
www.sensortechnics.com
140PC...-PCB Series
Signal conditioned precision pressure transducers
OUTLINE DRAWING
30.0
port A
(high pressure)
31.5
2 x 5.08 typ.
9.1
3 terminals
0.56 diam.
10.7
4.8
diam.
3,4
3.2 diam.
2 x mounting holes
22.7
52.4
59.8
18.3
14.0
NOM 6.0
12.6
pin
1
2
3
mass: 20 g
1
2
3
connection
+Vs
-Vs
Vout
dimensions in mm
ORDERING INFORMATION
Operating pressure
Vacuum gage devices
Differential / gage devices
Absolute devices
Pressure/vacuum devices
0...-1 psig
0...-5 psig
0...-15 psig
0...-30 psig
0...-100 psig
0...1 psid(g)
0...5 psid(g)
0...15 psid(g)
0...30 psid(g)
0...100 psid(g)
0...150 psid(g)
0...15 psia
0...30 psia
0...100 psia
0...±1 psid(g)
0...±2.5 psid(g)
0...±5 psid(g)
0...±15 psid(g)
part number
141PC01G-PCB
141PC05G-PCB
141PC15G-PCB
141PC30G-PCB
141PC100G-PCB
142PC01D-PCB
142PC05D-PCB
142PC15D-PCB
142PC30D-PCB
142PC100D-PCB
142PC150D-PCB
142PC15A-PCB
142PC30A-PCB
142PC100A-PCB
143PC01D-PCB
143PC03D-PCB
143PC05D-PCB
143PC15D-PCB
Other pressure ranges and calibrations are available on request. Please contact First Sensor.
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11554 / A
3/3
www.first-sensor.com
www.sensortechnics.com