HONEYWELL 1805-01

1800/1805 Series
TO-8, 0 psi to 3 psi, 0 psi to
150 psi Silicon Pressure
Sensors
DESCRIPTION
The 1800/1805 Series contains a solid state piezoresistive
The 1800/1805 Series sensors are high performance TO-8
pressure sensor mounted in a standard TO-8 package. They
pressure transducers specifically designed to address a variety
are printed circuit board and pin-for-pin compatible with other
of both low and medium pressure original equipment
TO-8 pressure sensors.
manufacture applications.
The transducers offer two performance grades and a variety of
compensation options, including span and calibration to within
±2 mV (normalized output). The 1800/1805 Series can operate
with either constant current or voltage excitation.
FEATURES
•
POTENTIAL APPLICATIONS
Standard pressure ranges from 0 psi to 3 psi, 0 psi to
•
Instrumentation calibration
150 psi
•
Avionics/aerospace
•
Gauge, absolute or differential models
•
Medical equipment
•
Voltage or constant current excitation
•
HVAC
•
Choice of temperature compensation options
•
Pneumatic controls
– Laser trim, normalized output
– Laser trim, standard output
– Resistor compensation
•
Uncompensated version available for microprocessorbased designs
1800/1805 Series
TO-8, 0 psi to 3 psi, 0 psi to 150 psi
ENVIRONMENTAL SPECIFICATIONS (All devices)
Characteristic
Supply voltage, VS
Compensated temperature range
Operating temperature tange
Vibration
Shock
Life
Parameter
10 Vdc
-1 °C to 54 °C [34 °F to 129 °F]
-40 °C to 121 °C [-40 °F to 257 °F]
10 g rms at 20 Hz to 200 Hz
100 g for 11 ms
100 million cycles
PERFORMANCE CHARACTERISTICS
Parameter
100 MOhm at 50 Vdc
50 % ± 10 %
150 psig
260 °C [500 °F] 10 s max.
Supply voltage Vs =15 Vdc max.
Supply current Is = 2 mA max.
(1)
Characteristic
Zero pressure offset(1)
Zero pressure offset (3 psi to 5 only) (1)
Full-scale span(2)
Standard output–current excitation
Standard output–voltage excitation
Normalized output–current excitation
Normalized output–current excitation (3 psi only)
Normalized output–voltage excitation
Pressure non-linearity(3)
Pressure hysteresis(3)
Repeatability
Temperature effect on offset(4)
Temperature effect on offset (3 psi and 5 psi only) (4)
Temperature effect on span
Temperature effect on span (3 psi and 5 psi only) (4)
Thermal hysteresis
Response time(5)
Long term stability of offset and span(6)
Common mode voltage(7)
Standard output–current excitation
Standard output–voltage excitation
Normalized output–current excitation
Normalized output–voltage excitation
Input resistance
Current excitation
Voltage excitation
Output resistance
PRESSURE RANGE SPECIFICATIONS
Catalog Listing
1805-00 (G,D) - (K,L) (0..4) (M,L,N)
1805-01 (G,D) - (K,L) (0..4) (M,L,N)
1800-02 (G,D) - (K,L) (0..4) (M,L,N)
1800-03 (G,D) - (K,L) (0..4) (M,L,N)
1800-07 (G,D) - (K,L) (0..4) (M,L,N)
1800-08 (G,D) - (K,L) (0..4) (M,L,N)
1800-09 (G,D) - (K,L) (0..4) (M,L,N)
1800-10 (G,D) - (K,L) (0..4) (M,L,N)
Characteristic
Insulation resistance
Humidity
Common-mode pressure
Max. soldering temperature
Excitation voltage VS
Excitation current
Pressure Range
0 psi to 3 psi
0 psi to 5 psi
0 psi to 10 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 50 psi
0 psi to 100 psi
0 psi to 150 psi
Min.
–
–
Typ.
–
–
Max.
±0.5
±1
Unit
mV
mV
75
40
98
73
38
–
–
–
–
–
–
–
–
–
–
–
–
–
–
±0.15
–
–
–
–
–
–
±0.1
–
–
150
120
102
77
42
±0.20
±0.0125
±0.0125
±0.5
±1
±0.5
±1
–
1
±0.2
mV
mV
mV
mV
mV
%FSS
%FSS
%FSS
mV
mV
mV
mV
%FSS
ms
%FSS
–
–
–
–
–
2.0
8.0
3.5
50 %
50 %
35 %
25 %
–
–
–
–
–
–
–
–
–
8.0
40
6.0
input
input
input
input
–
kΩ
kΩ
kΩ
Top Side Overpressure(8)
15 psi
25 psi
50 psi
65 psi
250 psi
350 psi
350 psi
350 psi
Bottom Side Overpressure(9)
9 psi
15 psi
30 psi
45 psi
50 psi
50 psi
50 psi
50 psi
Notes:
1. Reference conditions (unless otherwise noted); TA = 25 °C [77 °F], Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA ±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. FFS is
ratiometric to the supply voltage.
3. Pressure non-linearity is based on best-fit straight line from the zero to the full-scale pressure. Pressure hysteresis is the maximum output
difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F] reading.
5. Response time for a 0 psi to full-scale span pressure step change, 10 % to 90 % rise time.
6. Long term stability over a six month period.
7. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact the factory.
8. Pressure overrange: Top: 5 x full-scale pressure or ≤350 psi, whichever is less.
9. Pressure overrange: Bottom: 3 x full-scale or ≤50 psi, whichever is less.
2
www.honeywell.com/sensing
Silicon Pressure Sensors
STANDARD COMPENSATION AND TRIM CHOICES
For maximum convenience, the 1800/1805 Series is
temperature compensated from -1 °C to 54 °C [34 °F to
129 °F]. Other temperature ranges are available upon request.
Laser Trim: Compensation is accomplished by using an inhouse laser trim facility that allows for tighter product
performance control and improved flexibility in response to
special customer performance requirements.
Normalized Output Option: For design convenience and
sensor interchangeability, the 1800/1805 Series is available
with normalized output (100 ±2 mV dc in current excited
versions with pressure range >3 psi). Normalized output for
current excited 3 psi devices is 75 ±2 mV dc.
Resistors: This option includes a printout of suggested
temperature compensation and zero offset resistor values for
each individual sensor.
ELECTRICAL CONNECTIONS
Pin 1 on normalized and voltage
excited standard output.
CURRENT EXCITATION
Normalized output shown.
Standard output on pin 5 R6 shorted.
VOLTAGE EXCITATION
R5 open for standard output.
EXTERNAL CONNECTIONS
POSITIVE PRESSURE ON TOP AND BOTTOM SIDES
Current Excitation – Standard Output
Voltage Excitation – Standard Output
Discrete Resistor
Laser Trim Board
Discrete Resistor
Laser Trim Board
Pin
Connection
Pin
Connection
Pin
Connection
Pin
Connection
4
+ Output
4
+ Output
4
+ Output
4
+ Output
5
+ Input
5
+ Input
5
+ Input
5
NC
6
- Input
6
- Input
6
- Input
6
- Input
10
- Output
10
- Output
10
- Output
10
- Output
11
NC
11
NC
11
NC
11
NC
12
NC
12
NC
12
NC
12
NC
1
+ Input
PRESSURE CONNECTION OPTIONS
OPTION 0
OPTION 1
OPTION 2
Current or Voltage Excitation –
Normalized Output
Laser Trim Board
Pin
Connection
4
+ Output
5
NC
6
- Input
10
+ Output
11
NC
12
NC
1
+ Input
OPTION 4
Honeywell Sensing and Control
3
ORDER GUIDE
1800/1805
02
A
L
1
L
Compensation
Series
1800/1805
L: Laser trimmed, standard output
N: Laser trimmed, normalized output
M: Computer printout of resistor values
Pressure Range
For Model 1800 For Model 1805
02: 0 psi to 10 psi
00: 0 psi to 3 psi
03: 0 psi to 15 psi
01: 0 psi to 5 psi
07: 0 psi to 30 psi
08: 0 psi to 50 psi
09: 0 psi to 100 psi (G and A only)
10: 0 psi to 150 psi (G only)
Sensor Type
G: Gage
A: Absolute
D: Differential
Pressure Connections
Top
Bottom
0: 3/16 in tube
1: 3/16 hole
2: 3/16 in hole
4: 3/16 in tube
none
1/8 in tube
none
1/8 in tube
Excitation
L: Current
K: Voltage
Note:
Transducer recommended for use with non-corrosive, non-condensing gases.
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
•
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Automation and Control Solutions
Sensing and Control
Honeywell
11 West Spring Street
Freeport, Illinois 61032
www.honeywell.com/sensing
008137-2-EN IL50 GLO Printed in USA
October 2005
© 2005 Honeywell International Inc.