OMRON E3C-2

E3C
E3C
Special-Purpose Photoelectric Sensors
E3C
Miniature Sensors with Separate
Amplifiers Fit Tight Spaces
■
■
■
■
■
■
Fast, 1 ms response time
Light incident indicator on sensor
Dust-resistant flat lens surface
New, thin side view model
Prewired sensors have 2 m (6.56 ft) cable
Amplifier with built-in ON-, OFF- and oneshot delays available
■ New prewired DC amplifier designed for
track mounting has alarm output to signal
unstable sensing conditions
Ordering Information
■ SENSORS
Through-beam Type
Shape
Sensing distance 10 cm (3.94 in)
Part number
E3C-S10
20 cm (7.87 in
E3C-S20W
30 cm (11.81 in)
E3C-S30W
E3C-S30T
50 cm (19.69 in)
E3C-S50
1 m (3.28 ft)
E3C-1
2 m (6.56 ft)
E3C-2
Diffuse Reflective Type
Shape
Sensing distance
Part number
5 cm (1.97 in)
E3C-DS5W
10 cm (3.94 in)
E3C-DS10
■ AMPLIFIERS
Shape
Fits 1/16 DIN
panel cutout
Supply voltage
Output
100 to 240 VAC, 50/60 Hz
Relay and NPN solid-state
Timer functions
—
Mounting style
ON-delay
OFF-delay
One-shot
Socket (included)
Part number
E3C-A
E3C-C
For S3D8
controller
12 to 24 VDC
NPN and PNP
solid-state
—
Track
E3C-WH4F
2
Miniature
NPN
solid-state
—
PNP
solid-state
Socket Track
(order separately)
E3C-GE4
E3C-GF4
Slim, prewired
NPN
PNP
40 ms OFF-delay
E3C-JC4P
E3C-JB4P
E3C
E3C
■ ACCESSORIES
Description
Mounting brackets
Sockets required for
E3C-G❑4 amplifier
Mounting track
Part number
OAC-T1
OAC-T2
OAC-T3
E39-L42
E39-L31
PYF08M
PYF08A-E
PFP-50N
PFP-100N
PFP-M
PFP-S
U-shaped, for E3C-S10, with 10 mm (0.394 in) sensing distance gap
U-shaped, for E3C-S10, with 20 mm (0.787 in) sensing distance gap
U-shaped, for E3C-S10, with 30 mm (1.181 in) sensing distance gap
L-shaped, for E3C-DS10
L-shaped, for E3C-S50
Bottom surface mount socket
Combination bottom surface and track-mount socket
DIN rail, 50 cm (1.64 ft) length
DIN rail, 1 m (3.28 ft) length
End plate
Spacer
■ REPLACEMENT PARTS
Description
Track-mount socket for E3C-A and E3C-C amplifiers
Mounting bracket for E3C-1
Mounting bracket for E3C-2
Mounting bracket for E3C-J❑4P
Part number
PF113A-E
E39-L41
E39-L42
E39-L48
■ TYPICAL APPLICATIONS
Detect parts coming from a bowl feeder
in a space-confined location
Space-saving flat sensors can detect small parts
in tight spaces
E3C-S20W
E3C-S50
3
E3C
E3C
Specifications
■ THROUGH-BEAM TYPE
Part number
Sensing distance
Light source
Detectable
Type
object
Size
E3C-S10
E3C-S20W
E3C-S30❑ E3C-S50
E3C-1
10 cm (3.94 in)
20 cm (7.87 in) 50 cm (1.64 ft)
1 m (3.28 ft)
Pulse modulated infrared LED
Opaque materials
2 mm (0.08 in)
2 mm (0.09 in) 3 mm (1.18 in)
4 mm (0.16 in)
min. dimension
min. dimension min. dimension
min. dimension
Required amplifier
E3C-A, E3C-C, E3C-GE4, E3C-GF4, E3C-JC4P, E3C-JB4P, E3C-WH4F
Indicators
Emitter
Light Incident (red LED)
Receiver
None
Materials
Lens
Plastic, polycarbonate
Case
Plastic, polycarbonate
Cable sheath Plastic, polyethylene
Mounting
Side surface
Side surface
Side surface with two
Side surface
with two through
with two through through holes. Bracket
with two through
holes. Brackets
holes.
E39-L31 optional, see
holes. Bracket
OAC-T1, OAC-T2,
Accessories
E39-L41 and
OAC-T3 optional,
hardware
see Accessories
included.
Connections Prewired
Emitter: 2-conductor cable, 2 m (6.56 ft) length
Receiver: 2-conductor cable, 2 m (6.56 ft) length
Weight
Emitter
25 g (0.9 oz.)
30 g (1.1 oz.)
Receiver
25 g (0.9 oz.)
30 g (1.1 oz.)
Enclosure
UL
—
ratings
NEMA
1, 2, 12
1
1
1, 2, 12
1, 2, 4, 4X, 12
IEC 144
IP64
IP50
IP60
IP64
IP66
Approvals
UL
—
CSA
—
Ambient
Operating
-25° to 70°C (-13° to 158°F)
temperature Storage
-25° to 70°C (-13° to 158°F)
E3C-2
2 m (3.28 ft)
8 mm (0.32 in)
min. dimension
Zinc die-cast
Side surface
with two through
holes. Bracket
E39-L42 and
hardware
included.
60 g (2.2 oz.)
60 g (2.2 oz.)
■ DIFFUSE REFLECTIVE TYPE
Part number
Sensing distance
Detectable object type
Required amplifier
Indicators
Materials
Lens
Case
Cable sheath
Mounting
Connections
Weight
Enclosure
ratings
Approvals
Ambient
temperature
Prewired
UL
NEMA
IEC 144
UL
CSA
Operating
Storage
E3C-DS5W
E3C-DS10
5 cm (1.97 in) with 10 X 10 cm
10 cm (3.94 in) with 5 X 5 cm (1.97 in)
(3.94 in) 90% reflectance white mat paper
90% reflectance white mat paper
Opaque and transparent materials
E3C-A, E3C-C, E3C-GE4, E3C-GF4, E3C-JC4P, E3C-JB4P, E3C-WH4F
Light Incident (red LED)
Plastic, polycarbonate
Plastic, polycarbonate
Plastic, polyethylene
Side surface with two through holes.
Side surface with two through holes.
Bracket E39-L42 optional, see Accessories.
4-conductor cable, 2 m (6.56 ft) length
50 g (1.8 oz.)
—
1
1, 2, 12
IP50
IP64
—
—
-25° to 70°C (-13° to 158°F)
-25° to 70°C (-13° to 158°F)
4
E3C
E3C
■ AMPLIFIERS
AC Powered
Part number
Supply voltage
Power consumption
Operation mode
Sensitivity
Control
Relay
output
DC
solidstate
Response
time
ON
OFF
Timer functions
Circuit
protection
Indicators
Materials
Mounting
Connections
Weight
Enclosure
ratings
Approvals
Ambient
temperature
Type
Max. load
Min. load
Type
Max. load
Max. on-state
voltage drop
Solid-state
Contact
Solid-state
Contact
Type
Range
Output shortcircuit
E3C-A
E3C-C
100 to 240 VAC, 50/60 Hz
3 VA max.
Light-ON/Dark-ON, switch selectable
Adjustable
SPDT
1 A, 240 VAC (p.f. = 1)
1 mA, 5 VDC
NPN-SPST with constant current source
Load (relay, sink) logic, 80 mA, 24 VDC
Voltage logic (source): 1.5 to 4 mA
1.0 VDC
1 ms or 2 ms max., switch selectable
20 ms max.
1 ms or 2 ms max., switch selectable
20 ms max.
—
ON-delay, OFF-delay, one-shot, switch selectable
—
0.1 to 1 second or 1 to 10 seconds, switch selectable
Not available
Light Incident (red LED), Output Stability (green LED), Output Operation (red LED)
Plastic
Requires PF113A-E socket (included); socket mount to DIN rail track
Terminal screws on socket
220 g (7.8 oz.), including socket
—
1
IP20
—
—
-10° to 55°C (14° to 131°F)
-25° to 70°C (-13° to 158°F)
Case
UL
NEMA
IEC144
UL
CSA
Operating
Storage
DC Powered
Part number
Supply voltage
Current consumption
Operation mode
Sensitivity
Control DC
Type
output solidstate
Max. load
Alarm
output
Response
time
Circuit
protection
E3C-JB4P
E3C-JC4P
E3C-GE4
E3C-GF4
12 to 24 VDC ±10%; 1 V max. permissible ripple peak-to-peak
50 mA
Light-ON/Dark-ON
Light-ON/Dark-ON,
switch selectable
jumper selectable
Adjustable
PNP output
NPN output
NPN output
PNP output
with constant
current source
100 mA max.
100 mA max.
Load (relay, sink)
100 mA max.
24 VDC
24 VDC
logic: 80 mA, 24 VDC
24 VDC
Voltage logic (source):
1.5 to 4 mA
0.7 VDC
0.7 VDC
1.2 VDC
Max. on-state
voltage drop
Type
Max. load
ON
PNP
NPN
50 mA, 24 VDC 50 mA, 24 VDC
1 ms
OFF
1 ms or 40 ms, selectable
Output short-circuit
DC power supply
reverse polarity
Yes
Yes
—
—
1 ms or 2 ms max.,
selectable
1 ms or 2 ms max.,
selectable
Yes
Yes
5
E3C-WH4F
Light-ON/Dark-ON,
switch selectable
NPN and PNP
open collector
outputs
100 mA, 40 VDC
(each output)
0.7 VDC
1 ms or 2 ms max.,
switch selectable
1 ms or 2 ms max.,
switch selectable
Yes
Yes
E3C
E3C
DC Amplifiers, continued
Part number
Indicators
Materials
Mounting
Case
Connections
Weight
Enclosure
Approvals
Ambient
temperature
UL
NEMA
IEC 144
UL
CSA
Operating
Storage
E3C-JB4P
E3C-JC4P
E3C-GE4
E3C-GF4
Light Incident (red LED), Output Stability (green LED)
Plastic
DIN rail track or mounting
Requires PYF08A-E
bracket E39-L48 (included)
or PYF08M
or side surface with two
socket (not included).
through holes
Order separately
from Accessories.
Prewired with 5 conductor
Terminal screws
cable, 2 m (6.56 ft) length
on socket
80 g (2.8 oz.)
—
1, 2
IP50
—
—
-10° to 55°C (14° to 131°F)
-25° to 70°C (-13° to 158°F)
15 g (0.5 oz.)
—
1
IP20
■ OUTPUT CIRCUIT DIAGRAMS
Amplifiers E3C-A, E3C-C
Amplifiers E3C-J❑4P
PNP output type
E3C-JB4P
NPN output type
E3C-JC4P
6
E3C-WH4F
DIN rail track or
bottom surface with
two through holes.
Terminal screws or
direct connection to
S3D8 Sensor
Controller with
E99-C connector
(included).
100 g (3.5 oz.)
E3C
E3C
OUTPUT CIRCUIT DIAGRAMS, continued
Amplifier E3C-GE4
Light-ON
Dark-ON
PNP Output E3C-GF4
Light-ON
0V
Dark-ON
+12 to 24 VDC
+12 to 24 VDC
0V
Load
Amplifier E3C-WH4F
Engineering Data
■ EXCESS GAIN RATIO
E3C-S20W
E3C-S10
E3C-S30T, E3C-S30W
100
50
10
10
10
Excess gain ratio
Excess gain ratio
Excess gain ratio
100
1
1
1
0
5
10
Detecting distance (cm)
15
0
5
10 15 20 25 30 35
Detecting distance (cm)
7
40 45
50
0
20
40
60
Detecting distance (cm)
80
100
E3C
E3C
EXCESS GAIN RATIO, continued
E3C-S50
E3C-2
E3C-1
Excess gain ratio
100
10
1
0
10
20 30 40 50 60 70
Detecting distance (cm)
E3C-DS5W
80
90 100
E3C-DS10
■ LIGHT SOURCE/RECEIVER SETTING RANGE
E3C-S30T, E3C-S30W
E3C-S20W
Parallel offset distance Y (cm)
Separate type
E3C-S10
Detecting distance X (cm)
8
E3C
E3C
LIGHT SOURCE/RECEIVER SETTING RANGE, continued
E3C-S50
E3C-1
E3C-2
E3C-DS10 (Example 1)
E3C-DS10 (Example 2)
■ OPERATING RANGE
Diffuse Reflective Type
E3C-DS5W
Dimensions
Unit: mm
■ SENSORS
E3C-S10
Mounting Brackets for E3C-S10
Mount the emitter and receiver on
the legs of the U-shaped bracket so
they face each other. Dimension
"A" shows the fixed sensing
distance.
Part number
OAC-T1
OAC-T1
OAC-T3
9
Dimension A
10 mm (0.394 in)
20 mm (0.787 in)
30 mm (1.81 in)
E3C
E3C
E3C-S20W
Receiver
Light source
E3C-S30T
2 m (6,56 ft) cable, 1.8 mm OD
E3C-S30W
2 m (6,56 ft) cable, 1.8 mm OD
10
E3C
E3C
E3C-S50
E39-L31 Optional Mounting Bracket
E3C-1
NOTE:
E3C-1 is shown
mounted in E39-L41
bracket supplied with
each sensor.
E3C-2
NOTE:
E3C-2 is shown mounted
in E39-L42 bracket
supplied with each
sensor.
E3C-DS5W
11
E3C
E3C
E3C-DS10
NOTE:
Use mounting bracket
E39-L42, shown on
E3C-2; order separately
from Accessories.
■ AMPLIFIERS
E3C-A, E3C-C
NOTE: Socket PF113A-E and two hold-down clips are included with these amplifiers.
E3C-JB4P, E3C-JC4P
* Attach the caution label after adjusting the sensitivity adjuster.
** This is not necessary when mounting the amplifier
on DIN rail track.
E3C-GE4, E3C-GF4
NOTE:
Order required socket
PYF08A-E or PYF08M from
Accessories section.
12
E3C
E3C
E3C-WH4F
Mounting holes
■ SOCKETS
PF113A-E Track-Mount Socket
Socket PF113A-E and two hold-down
clips are supplied with E3C-A and E3C-C
amplifiers.
Terminal
arrangement
(top view)
PYF08A-E Combination Track and Bottom Mount Socket for E3C-GE4, E3C-GF4
Terminal
arrangement
(top view)
Mounting holes
Mounting holes
PYF08M Bottom Surface Mount Socket for E3C-GE4, E3C-GF4
Terminal arrangement
(top view)
13
Mounting holes
E3C
E3C
■ MOUNTING TRACK AND ACCESSORIES
PFP-100N/PFP-50N DIN Rail
PFP-M End Plate
PFP-S Spacer
Connections
Amplifier
model
Sensors
Diffuse reflective type
Through-beam type
E3C-S10, E3C-S20W, E3C-S30■, E3C-S50, E3C-1, E3C-2
E3C-DS5W, E3C-DS10
E3C-A,
E3C-C
E3C-JB4P
and
E3C-JC4P
E3C-GE4
Notes
*Shielded wires must not be peeled in excess of 2 cm
(0.787 in) for receiver (white lead) and 5 cm (1.969 in) for
the light source (red lead).
**Response time is 1 ms when terminal 8 is left open and
2 ms when terminal 8 is short-circuited with the
0 V terminal of the power supply (negative side).
14
*Shielded wires must not be peeled in excess of 2 cm
(0.787 in).
**Response time is 1 ms when terminal 8 is left open and
2 ms when terminal 8 is short-circuited with the 0 V
terminal of the power supply (negative side).
E3C
E3C
Connections, continued
Amplifier
model
Sensors
Through-beam type
Diffuse reflective type
E3C-S10, E3C-S20W, E3C-S30■, E3C-S50, E3C-1, E3C-2 E3C-DS5W, E3C-DS10
E3C-WH4F
Notes
NOTE: Terminals 5, 6, 7, and 8 are not used when connected to S3D8
or S3D-F sensor controllers.
NOTE: Terminals 5, 6, 7, and 8 are not used when connected to S3D8
or S3D-F sensor controllers.
*Shielded wires must not be peeled in excess of
2 cm (0.787 in) for the receiver (white lead) and 5 cm
(1.969 in) for the light source (red lead).
*Shielded wires must not be peeled in excess of
2 cm (0.787 in).
Operation
■ E3C-A Timing Chart
■ E3C-A Amplifier
Selection of operation mode
DARK ON
LIGHT ON
When light is incident, the output relay
operates and solid-state output becomes
high (H).
DARK ON
LIGHT ON
When light is interrupted, the output relay
operates and the solid-state output becomes
high (H).
Selection of response time
NOTE: 1. Control output is produced only during the input time.
2. When t exceeds 1 ms or 2 ms, solid-state output is produced. To produce
relay contact output, t must be longer than 20 ms.
15
2 msec (B)
1 msec (A)
The response time is set to 2 ms.
2 msec (B)
1 msec (A)
The response time is set to 1 ms.
E3C
E3C
■ E3C-C AMPLIFIER
Selection of operation mode
Selection of response time
Setting the delay time
Gate input operation
When the gate input terminal 9 is opened at HIGH level (6 to 30
VDC), the output relay performs the timer operation according
to the input signal (light incident or light interrupted).
When the gate input terminal 9 is short-circuited with the 0 V
terminal 2 at LOW level (0 to 2 VDC), the output relay releases
without regard to the input signal or output state. The terminal
generates an inhibit signal.
Selecting timer function
ON D.
(ON-delay)
operation
OFF D.
(OFF-delay)
operation
O.S.D.
(One-shot
delay)
operation
16
E3C
E3C
E3C-C ON-Delay Timing Chart
E3C-C One-Shot Timing Chart
E3C-C OFF-Delay Timing Chart
■ E3C-JB4P, E3C-JC4P AMPLIFIERS
Timing Charts
Light-ON
Stability
indicator
(green LED)
Light
incident
(red LED)
Sensitivity
adjuster
OFF-delay
selector
switch
Light-ON/
Dark-ON
operation
selector
switch
Light beam
Dark-ON
Light beam
Incident
Interrupted
LIGHT
ON
indicator
OFF
Transistor Output
ON
(1 ms)
OFF
Transistor Output
ON
(40 ms OFF-delay)
OFF
Incident
Interrupted
LIGHT
indicator
ON
OFF
Transistor Output
(1 ms)
ON
OFF
Transistor Output
(40 ms OFF-delay)
ON
OFF
Alarm Output Timing Chart
The alarm output operates when the control output approaches
critical OFF or ON state for more than 300 ms. An unstable
state occurs when the amount of light incident upon the
receiving element is within 20% of the amount of light needed
to change the control output state.
The alarm output feature is designed to indicate gradual
changes in sensor/reflector position, atmosphere, temperature
or ambient light which result in an unstable control output. A
change occurring less than 300 ms will not cause the alarm
output to operate.
A 300 ms time delay is built into the alarm output circuit. This
prevents false triggering of the alarm output as the leading and
trailing edges of the object to be detected are sensed. The
time can be extended by using an ON-delay timer in the circuit.
Operation level 120%
Operation level
Operation level 80%
Control output
(light on mode)
On
Off
Self-diagnostic
output
On
Off
300 ms max.
17
300 ms max.
E3C
E3C
■ E3C-GE4 , E3C-GF4 AMPLIFIER
E3C-GF4 Timing Chart
Selection of response time
NOTE: t1 and t2 must exceed selected response time (1 or 2 ms) before solid-state
output states will change.
Response
1 ms
2 ms
Wiring
Terminal 8 open
Terminal 8 shorted with terminal 4 (0 V)
■ E3C-WH4F AMPLIFIER
E3C-WH4F Timing Chart
NOTE: t1 and t2 must exceed selected response time (1 or 2 ms) before solid-state
output states will change.
18
E3C
E3C
OMRON ELECTRONICS LLC
OMRON ON-LINE
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
Cat. No. CEDSAX4
11/01
Specifications subject to change without notice.
19
416-286-6465
Printed in the U.S.A.