ETC 186314186314

General-purpose Relay
MY
An Improved Miniature Power Relay
with Many Models for Sequence Control
and Power Applications
A wide range of relay variations including ones with
operation indicators, high-capacity capability,
built-in diodes, etc.
Arc barrier standard on 3- and 4-pole relays.
Withstand voltage: 2,000 VAC.
Ordering Information
Type
Contact form
Plug-in socket/solder terminals
PCB terminals
Upper-mounting/
solder terminals
With indicator
Standard
SPDT
*MY1
–––
*MY1-02
MY1F
DPDT
MY2
MY2N
MY2-02
MY2F
DPDT (bifurcated)
MY2Z
MY2ZN
MY2Z-02
MY2ZF
3PDT
MY3
MY3N
MY3-02
MY3F
4PDT
MY4
MY4N
MY4-02
MY4F
4PDT (bifurcated)
MY4Z
MY4ZN
MY4Z-02
MY4ZF
With built-in diode
DPDT
MY2-D
MY2N-D2
–––**
–––
(DC only)
DPDT (bifurcated)
MY2Z-D
MY2ZN-D2
–––
–––
3PDT
MY3-D
MY3N-D2
–––
–––
4PDT
MY4-D
MY4N-D2
–––
–––
4PDT (bifurcated)
MY4Z-D
MY4ZN-D2
–––
–––
With built-in CR
DPDT
MY2-CR
MY2N-CR
–––
Not available.
(AC only)
DPDT (bifurcated)
MY2Z-CR
–––
–––
3PDT
MY3-CR
–––
–––
4PDT
MY4-CR
MY4N-CR
–––
4PDT (bifurcated)
MY4Z-CR
–––
–––
DPDT
MY2I4
MY2I4N
–––
–––
4PDT
MY4I4
MY4I4N
–––
–––
With test button
1
MY
MY
Type
Contact form
Plug-in socket/solder terminals
PCB terminals
Upper-mounting/
solder terminals
With indicator
High-humidity
DPDT
MY2-TU
–––
–––
–––
DPDT (bifurcated)
MY2Z-TU
–––
–––
–––
3PDT
MY3-TU
–––
–––
–––
4PDT
MY4-TU
MY4N-TU
–––
–––
4PDT (bifurcated)
MY4Z-TU
–––
–––
Not available.
High-capacity (7 A)
DPDT
MY2-Y
MY2N-Y
–––
High-sensitivity
3PDT
MYC3
Not available
MYC3-02
Note:
1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Example: MY2, 6 VAC
Rated coil voltage
*2. Models mark with an asterisk are not available with international safety standard ratings.
3. Add “-G” to the model number if mounting studs are required (e.g., MY4-G).
4. The standard contacts for MY2Z-series Relays and for the MY4Z are gold-plated.
**5. Models denoted by “–––” will be manufactured upon request. Ask your OMRON representative.
6. The following variations are also available.
Plastic-sealed relays (MYQ4):
See page 46.
Latching relays (MY2K):
See page 51.
Hermetically sealed relays (MY4H): Ask your OMRON representative.
Accessories (Order Separately)
Sockets
Poles
Front-mounting socket
Back-mounting socket
(DIN-rail/screw mounting)
Solder terminals
W/ clip
W/o clip
Wire-wrap terminals
W/ clip
W/o clip
PCB
terminals
1 or 2
PYF08A-E, PYF08A,
PYF08A-N (finger protection)
PY08
PY08-Y1
PY08QN
PY08QN-Y1
PY08–02
3
PYF11A-E, PYF11A
PY11
PY11-Y1
PY11QN
PY11QN-Y1
PY11-02
4
PYF14A-E, PYF14A
PYF14A-N (finger protection)
PY14
PY14-3*
PY14-Y1
PY14QN
PY14QN-Y1
PY14-02
Note:
*1. Equipped with operation check terminal.
2. The PYF08A(-E), PYF11A(-E), and PYF14A(-E) have been approved as individual sockets by UL S08 and CSA C22.2.
Mounting Plates for Sockets
Socket model
PY08, PY11, PY14, PY08QN(2),
PY11QN(2), PY14QN(2)
Note:
2
For 1 socket
PYP-1
For 18 sockets
PYP-18
For 36 sockets
PYP-36
PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of sockets.
MY
MY
Socket Hold-down Clip Pairing
Relay type
Poles
Front-connecting
sockets
(rail-/screw-mounted)
Socket
Standard, bifurcated contacts, operation
indicator, built-in diode, high-capacity,
high-sensitivity,
g
y, or high-humidity
g
y
Clip
Solder/wire-wrap terminals
Socket
PCB terminals
Clip
3
PYF11A
PY11(QN)
PY11(QN)
4
PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN)
PY14(QN)
MY2N-D4
4
PYF14A-N,
PYF14A-E,
PYF14A
Y92H-3
PY14(QN)
PYC-1
PY08(QN)
PYC-1
Test button
1, 2
PYF08A-N,
PYF08A-E,
PYF08A
PYC-A1
PY08(QN)
PYC-P2
PY08(QN)
PYC-P2
3
PYF11A
PY11(QN)
PY11(QN)
4
PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN)
PY14(QN)
1, 2
PYF08A-N,
PYF08A-E,
PYF08A
3
PYF11A
PY11(QN)
PY11(QN)
4
PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN)
PY14(QN)
PY08(QN)
PYC-P
PY08(QN)
Clip
PYF08A-N,
PYF08A-E,
PYF08A
Y92H-3
PY08(QN)
Socket
1, 2
CR circuit
PYC-A1
Back-connecting sockets
PYC-1
PY08(QN)
PYC-P
PYC-1
Specifications
Coil Ratings
Rated voltage
Rated current
50 Hz
AC
DC
Note:
Coil
resistance
60 Hz
Inductance
(reference value)
Arm.
OFF
Must
operate
Arm. ON
Must
release
Max.
voltage
% of rated voltage
6V
214.1 mA
183 mA
12.2 Ω
0.04 H
0.08 H
80%
30%
12 V
106.5 mA
91 mA
46 Ω
0.17 H
0.33 H
max.
min.
24 V
53.8 mA
46 mA
180 Ω
0.69 H
1.30 H
50 V
25.7 mA
22 mA
788 Ω
3.22 H
5.66 H
100/110 V
11.7/12.9 mA
10/11 mA
3,750 Ω
14.54 H
24.6 H
110/120 V
9.9/10.8 mA
8.4/9.2 mA
4,430 Ω
19.20 H
32.1 H
200/220 V
6.2/6.8 mA
5.3/5.8 mA
12,950 Ω
54.75 H
94.07 H
220/240 V
4.8/5.3 mA
4.2/4.6 mA
18,790 Ω
83.50 H
136.40 H
6V
150 mA
40 Ω
0.17 H
0.33 H
10%
12 V
75 mA
160 Ω
0.73 H
1.37 H
min.
24 V
36.9 mA
650 Ω
3.20 H
5.72 H
48 V
18.5 mA
2,600 Ω
10.60 H
21.00 H
100/110 V
9.1/10 mA
11,000 Ω
45.60 H
86.20 H
110%
Power
consum.
(A
)
(Approx.)
1.0 to
1 2 VA
1.2
(60 Hz)
0.9 to
1 1 VA
1.1
(60 Hz)
0.9 W
See notes under next table on next page.
3
MY
MY
High-sensitivity Relays
Power supply ratings
Voltage
Current
Coil
resistance
Input ratings
Max.
voltage*
Power consum.
Input
voltage
Approx. 900 mW
2 to 12 V
Must
operate
Must
release
Power
consum.
% of rated voltage
24 VDC
Note:
36.9 mA
650 W
110%
2 V max.
1 V min.
0.5 to 52 mW
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents
and ±15% for DC coil resistance.
2.
3.
4.
5.
Performance characteristic data are measured at a coil temperatures of 23°C.
The must operate and must release voltages for High-sensitivity Relays was measured at the rated power supply voltage.
AC coil resistance and impedance are provided as reference values (at 60 Hz).
Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder
resistor if required.
Contact Ratings
Item
Single-, double- or three-pole
Resistive load
(cosf = 1)
Four-pole and High-sensitivity
Inductive load
(cosf=0.4,
L/R=7 ms)
2 A, 220 VAC
2 A, 24 VDC
Resistive load
(cosf = 1)
3 A, 220 VAC
3 A, 24 VDC
Inductive load
(cosf=0.4,
L/R=7 ms)
0.8 A, 220 VAC)
1.5 A, 24 VDC
High-capacity
Resistive load
(cosf = 1)
Rated load
5 A, 220 VAC
5 A, 24 VDC
Carry
current
5A
3A
7A
Max.
switching
voltage
250 VAC
125 VDC
250 VAC
125 VDC
250 VAC
125 VDC
Max.
switching
current
5A
5A
3A
3A
7A
7A
Max.
switching
capacity
1,100 VA
120 W
440 VA
48 W
660 VA
72 W
176 VA
36 W
1,540 VA
168 W
770 VA
84 W
Min.
permissible
load*
Standard type: 100 mA, 5 VDC
Bifurcated type: 100 µA, 1 VDC
Standard and high sensitivity types: 1
mA, 1 VDC
Bifurcated type: 100 µA, 1 VDC
7 A, 220 VAC
7 A, 24 VDC
Inductive load
(cosf=0.4,
L/R=7 ms)
3.5 A, 220 VAC
3.5 A, 24 VDC
–––
*Note: P level: λ60 = 0.1 x 10-6/operation, reference value
Characteristics
Item
All relays but High-sensitivity Relays
High-sensitivity Relays
Contact resistance
50 mΩ max.
Operate time
20 ms max.
Release time
20 ms max.
Max. operating frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric withstand voltage
2,000 VAC, 50/60 Hz for 1 min (1,000 VAC
between contacts of same polarity)
Vibration resistance
Destruction: 10 to 55 Hz, 1.0-mm double amplitude
Malfunction: 10 to 55 Hz, 1.0-mm double amplitude
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 (approx. 20G)
Life expectancy
See following table.
Ambient operating temperature*
Single- and double-pole standard, bifurcated-contact, test-button, and high-humidity relays:
–55°C to 70°C (with no icing)
All other relays: –55°C to 60°C (with no icing)
Ambient operating humidity
35% to 85%
Weight
Approx. 85 g
Note:
4
The values given above are initial values.
1,500 VAC, 50/60 Hz for 1 min (1,000 VAC
between contacts of same polarity)
MY
MY
Life Expectancy Characteristics
Relays
Mechanical life
(at 18,000 operations/hr)
Electrical life
(at 1,800 operations/hr under rated load)
Normal, High-humidity, With test button (except relays
with operation indicator), With CR
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
1-,2-,3-pole: 500,000 operations min.
4-pole:
200,000 operations min.
High-capacity
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
500,000 operations min.
With operation indicator or built-in diode
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
1-,2-,3-pole: 500,000 operations min.
4-pole:
200,000 operations min.
With bifurcated contacts
2-pole: 50,000,000 operations min.
4-pole: 20,000,000 operations min.
2-pole: 200,000 operations min.
4-pole: 100,000 operations min.
High-sensitivity
100,000,000 operations min.
200,000 operations min.
Note:
See following tables for real load life expectancies.
Life Expectancies Under Real Loads
MY2
Rated voltage
100 VAC
Load type
AC motor
AC solenoid
Conditions
Operating frequency
Electrical life
50 W, 100 VAC single-phase with
2.8-A inrush current, 0.4-A carry
current
ON for 2 s, OFF for 30 s
100,000 operations
50 W, 100 VAC single-phase with
1.6-A inrush current, 1-A carry current
ON for 1 s, OFF for 30 s
300,000 operations
24 W with 1-A carry current
ON for 1.5 s, OFF for 1.5 s
4,000,000 operations
MY2E
Rated voltage
24 VDC
Load type
AC lamp
Conditions
300 W with 50-A inrush current, 3-A
carry current
Operating frequency
ON for 5 s, OFF for 55 s
Electrical life
55,000 operations
MY4
Rated voltage
100 VAC
24 VDC
Load type
Conditions
Operating frequency
ON for 1 s, OFF for 3 s
Electrical life
AC solenoid
50 VA with 2-A inrush current, 0.7A
carry current
25,000 operations
DC magnetic
switch
25 W with L/R = 40 ms , 0.2-A carry
current
AC magnetic
switch
35 VA with 1.5-A inrush current,
0.35-A carry current
DC solenoid
40 W with L/R = 10 ms, 1.6-A carry
current
ON for 0.5 s, OFF for 1.5 s
5,000,000 operations
30 W with L/R = 10 ms with 0.34-A
carry current
ON for 0.5 s, OFF for 1.5 s
6,000,000 operations
500,000 operations
5
MY
MY
Approved by Standards
Some MY Relays are available in models meeting various safety
standards. When ordering, you must specify the desired standards.
Refer to Ordering Information for specific models. Note that the rating recognized by the various standards sometimes vary from the
ratings of the individual relays.
SEV
Model
MYj
No. of
poles
2, 3
6 to 100
VDC
6 to 220
VAC
UL 508 Recognitions (File No. 41515)
No. of poles
2
Coil ratings
6 to 240 VAC
6 to 120 VDC
3
Contact ratings
5 A, 120 VAC resistive load
5 A, 28 VDC resistive load
5 A, 240 VAC inductive load
5 A, 28 VDC resistive load
5 A, 240 VAC inductive load
4
6 to 240 VAC
6 to 120 VDC
Coil
ratings
Contact ratings
5 A, 200 VAC
5 A, 24 VDC
LR (No. 563KOB-204524)
Model
MYj-LR
3 A 28 VDC resistive load
3 A 120 VAC inductive load
1.5 A, 240 VAC inductive load
5 A, 240 VAC inductive load
(between contacts of same
polarity)
5 A, 28 VDC resistive load
(between contacts of same
polarity)
0.2 A, 120 VDC
No. of
poles
2
Coil
ratings
6 to 240
VAC
6 to 120
VDC
4
Contact ratings
2 A, 30 VDC inductive
load
2 A, 200 VAC inductive
load
1.5 A, 30 VDC
inductive load
0.8 A, 200 VAC
inductive load
1.5 A, 115 VAC
inductive load
CSA 22.2 No. 0 and No.14 (File No. LR31928)
Model
MYj
No. of
poles
2, 3
Coil
ratings
6 to 240
VAC
6 to 120
VDC
4
Contact ratings
5 A, 28 VDC resistive
load
5 A, 240 VAC inductive
load
3 A, 28VDC resistive
load
3 A, 240 VAC inductive
load
5 A, 240 VAC inductive
load (between contacts
of same polarity)
5 A, 28 VDC resistive
load (between contacts
of same polarity)
0.2 A, 120 VDC
Engineering Data
Maximum Switching Capacity
MY2-Y
AC resistive load
AC inductive load
(cosf = 0.4)
DC resistive
load
DC inductive
load (L/R = 7 ms)
Switching current (A)
Switching current (A)
MY1, MY2, MY3
AC resistive load
AC inductive load
(cosf = 0.4)
DC resistive
load
DC inductive load
L/R = 7 ms
Switching voltage (V)
6
Switching voltage (V)
MY
MY
MY4, MY4Z
AC resistive
load
Switching current (A)
AC inductive load
(cosf = 0.4)
DC resistive load
DC resistive load
L/R = 7 ms
Switching voltage (V)
Life Expectancy
5,000
110 VAC resistive load
220 VAC
resistive load
1,000
500
24 VDC resistive
load
100
MY1, MY2, MY3 (Inductive Loads)
Life expectancy (x103 operations)
Life expectancy (x103 operations)
MY1, MY2, MY3 (Resistive Loads)
5,000
110 VAC inductive
load (cosf = 0.4)
1,000
500
100
Switching current (A)
Switching current (A)
5,000
110 VAC resistive
load
220 VAC resistive load
1,000
500
30 VDC resistive
load
100
Switching current (A)
MY4 (Inductive Loads)
Life expectancy (x10 3 operations)
Life expectancy (x103 operations)
MY4 (Resistive Loads)
220 VAC inductive load
(cosf = 0.4)
24 VDC inductive load
(L/R = 7 ms)
5,000
110 VAC resistive
load
1,000
500
100
220 VAC resistive
load
30 VDC resistive
load
Switching current (A)
7
MY
MY
MY4Z (Inductive Loads)
5,000
1,000
500
100
220 VAC resistive load
24 VDC resistive load
Life expectancy (x103 operations)
Life expectancy (x103 operations)
MY4Z (Resistive Loads)
5,000
1,000
220 VAC (cosf = 0.4)
5,000
110 VAC resistive
load
1,000
220 VAC resistive load
500
24 VDC resistive
load
100
Life expectancy (x103 operations)
Life expectancy (x103 operations)
Switching current (A)
MY2-Y (Inductive Loads)
Switching current (A)
8
24 VDC
L/R = 7 ms
100
Switching current (A)
MY2-Y (Resistive Loads)
110 VAC (cosf = 0.4)
500
5,000
110 VAC (cosf = 0.4)
24 VDC L/R = 7 ms
1,000
500
220 VAC (cosf = 0.4)
100
Switching current (A)
MY
MY
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Relays with Solder Terminals
Terminal arrangement/internal connections
(bottom view)
MY1
2.6
MY1
Five, 1.2 dia. x 2.2 elliptic holes
0.5
28 max.
6.3
35.5 max.
6.4
21.5
max.
MY2, MY2-TU, MY2N, MY2N-D2
MY2N
Standard
2.6
DC type
AC type
Eight, 1.2 dia. x 2.2 ellipse holes
0.5
28 max.
6.3
0.5
36 max.
6.4
21.5
max.
Note:
1. AC type is equipped with a coil disconnection
self–diagnostic function.
2. Pay due attention as DC type has polarity.
MY2N-D2
9
MY
MY
MY3, MY3-TU, MY3N, MY3N-D2, MYC3
MY3N
2.6
Standard
DC type
AC type
Eleven, 1.2 dia. x 2.2
ellipse holes
28 max.
6.3
0.5
36
max.
6.4
21.5
max.
Note:
1. AC type is equipped with a coil disconnection self–
diagnostic function.
2. Do not reverse the polarity of DC relays.
MYC3
MY4N-D2
Coil connections
Input
Note:
10
The MYC3 High–sensitivity Relay incorporates a
semi–conductor. A surge–absorb element should
be attached to it if the relay is used with a load that
can generate noise, or a surge current cannot be
avoided in the circuit.
MY
MY
MY4, MY4-TU
2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes.
0.5
28 max.
6.3
0.5
36
max.
21.5
max.
6.4
Terminal arrangement/internal connections
(bottom view)
MY4N
Standard
Note:
MY4N-D2
DC type
AC type
1. AC type is equipped with a coil disconnection selfdiagnostic function.
2. Do not reverse the polarity of DC relays.
MYjI4
MYjI
2.6
2.6
2.6
3.3
20.3
Push button
Fourteen, 1.2 dia. x 2.2
ellipse holes
Fourteen, 1.2 dia. x 2.2
ellipse holes
3 max.
Push button
0.8
28 max.
0.5
28 max.
6.3
36
max.
Note:
6.4
4 max.
1. Mount the relay with a socket.
6.3
0.5
21.5 max..
36
max.
6.4
21.5 max.
Mounting holes
2. The above dimensions are for -G type relays
(with mounting studs).
3. Test button
I4: AC with red push button
DC with blue push button
16.4
0.5
Two, 5 dia.
holes
3.4 dia.
hole
Note:
3.8
13.2
19.4
The terminal arrangement and internal connections of the above relays are as same as these of MYj relays.
11
MY
MY
MYj(N)-CR, MYj(Z)-CR, MY4N-D4
MYj(N)-C
R
2.6
MYj(Z)-C
R
Fourteen, 1.2 dia. x 2.2 ellipse holes
CR
CR
0.5
28 max.
6.3
0.5
53
max.
21.5
max.
6.4
MY4N-D4
Relays with PCB Terminals
MYj-02
MY4-02 (4PDT)
PC board mounting holes
3.5
1
SPDT
DPDT
3PDT
13.2
13.2
13.2
3.3 (2.6)
4PDT
13.2
44
4.3
4.1
0.5
12.65
28 max.
6.35
6.3
6.3
0.5
36
max.
Note:
4
21.5
max.
1. The figures in the parentheses are for MY4-02.
2. The above dimensions also apply to the SPDT,
DPDT, and 3PDT relays.
4. The internal connections of the above relays are as
same as these of MYj relays.
12
3.75
Note:
Five,
1.3±0.1
holes
Eight,
1.3±0.1
holes
The tolerance is ±0.1.
Eleven,
1.3±0.1
holes
Fourteen,
1.3±0.1
holes
MY
MY
Upper-mounting Relays
MYjF
Mounting holes
MY4F
2.6
Two 3.5 dia holes or M3 holes
Fourteen, 1.2 dia. x 2.2
ellipse holes
2
4.35
38
29 max.
0.5
0.5
36
max
.
Note:
38 44 max.
6.4
3.5
22.5 max.
1. The above dimensions also apply to the SPDT,
DPDT, and 3PDT relays.
2. The internal connections of the above relays are as
same as these of MYj relays.
Mounting Height with Socket
DIN rail/surface–mounting socket
Back-mounting socket
MY
70 (87)
MY
66 (83)
54 (71)
39 (56)
MY
PYF08M
PYFjA(-E)
PYj
Note:
1. The PTF-A can be rail–mounted or screw-mounted.
2. For the MYj-CR (CR circuit built-in type) model, figure
in the parentheses apply.
3. PYC-P hold down clip should be used with PYF08M.
Sockets
PYF08A-E
PYF08A-N
PY14QN(2)-Y1
PY14-02
PYF14A-N
PY14
PY14-Y1
PY14QN(2)
13
MY
MY
Mounting Plates for Sockets
PYP-1
PYP-18
PYP-36
72 wide ellipse
hole
27.4
±0.15
492
17 x 27.4 = 465.8 ± 0.6
72 wide ellipse hole
21.6
27.4
±0.15
Two, 3.4 dia. holes
492
17 x 27.4 = 465.8 ± 0.6
21.6
13.1
13.1
4.5
3.4
+0.2
21.4 0
R1.7
4.5
3.4
39.7±0.2
Square
hole
86.4
42
±0.1
42±0.1
49
49
39.7±0.2
+0.2
21.4 0
28
t = 1.6
13.1
t = 1.6
21.6
17 x 27.4 = 465.8 ± 0.6
t = 1.6
Hold-down Clips
Hold-down clips are used to hold relays to sockets and prevent them from coming loose due to vibration or shock.
Connection to socket
PYC-A1
Connection to
mounting plate
PYC-P
PYC-S
PY14-3 (for 4PDT)
with operation check terminal
For relays with test
buttons
PYC–P2
For relays with CR circuits
Y92H-3
Mounting holes
81
56
28
9(7.7)
2
38.5
78 +0.3
–0
0.3 34.5+0.4
Operation check terminal
Operation checklamp can be built-in.
77.5 +0
–0.4
Three, 1.2 dia holes Two dia. holes Short-circuit lead wire
Safety Standards for Sockets
Item
Standards
File No.
PYF08A (-E), PYF11A
UL508
E87929
PYF14A (-E)
CSA22.2
LR31928
14
PYC-1
36 +0.3
–0
MY
MY
Precautions
Connections
Do not reverse polarity when connecting DC-operated relays with
built-in diodes or indicators or high-sensitivity DC-operated relays.
Mounting
•
•
Whenever possible, mount relays so that it is not subject to
vibration or shock in the same direction as that of contact
movement.
The test button should be be pointed upwards when mounting
(refer to the right figure).
Test button
15
MY
MY
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J01-E1-11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Relay Division
28th Fl., Crystal Tower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540 Japan
Phone: 06-949-6125 Fax: 06-949-6134
16
Printed in Japan
0794-2M