Bussmann® Super-Lag Renewable Fuses REN and RES and Fuse Links 250 and 600 Volts, 1-600 Amps (LKN & LKS) Dimensional Data REN (250V) 2" 7.13" .56" 1/10A to 30A 110A to 200A 3" 8.63" .81" 35A to 60A 225A to 400A 10.38" 5.88" 70A to 100A 450A to 600A Dimensional Data RES (600V) 0.81" 5" 1/10A to 30A 5.5" 35A to 60A 9.63" 110A to 200A 11.63" 1.06" 225A to 400A 13.38" 7.88" CATALOG SYMBOLS: REN (250V); RES (600V) TIME-LAG 1 TO 600 AMPERES 250 AND 600 VOLTS AC (OR LESS) NON-CURRENT LIMITING INTERRUPTING RATING–10,000A RMS SYM. CLASS H 11-27-00 J00269 70A to 100A 450A to 600A • Designed for easy replacement. • No multiple links to complicate replacement. • Buss SUPER-LAG Renewable fuses with longer time-lag than other Class H fuses of this type can better sustain overloads without needlessly opening. • SUPER-LAG fuses are used in circuits of industrial and commercial structures where maximum short-circuit currents are of a low level (below 10,000 amperes) and frequent outages dictate the economy of the “renewable” type fuse. • These fuses are generally sized at the ampere rating of noninductive circuits and 300% for motor circuits. Form No. REN/RES Page 1 of 4 BIF Doc #1028 Bussmann® Super-Lag Renewable Fuses REN and RES and Fuse Links 250 and 600 Volts, 1-600 Amps (LKN & LKS) RENEWABLE FUSES REN SUPER-LAG –– 250 VOLTS AC RES SUPER-LAG –– 600 VOLTS AC Catalog Numbers and Ampere Ratings Catalog Numbers and Ampere Ratings REN-1 REN-12 REN-60 REN-200 RES-1 RES-15 RES-70 RES-225 REN-2 REN-15 REN-70 REN-225 RES-2 RES-20 RES-80 RES-250 REN-3 REN-20 REN-80 REN-250 RES-3 RES-25 RES-90 RES-300 REN-4 REN-25 REN-90 REN-300 RES-4 RES-30 RES-100 RES-350 REN-5 REN-30 REN-100 REN-350 RES-5 RES-35 RES-110 RES-400 REN-6 REN-35 REN-110 REN-400 RES-6 RES-40 RES-125 RES-450 REN-7 REN-40 REN-125 REN-450 RES-8 RES-45 RES-150 RES-500 REN-8 REN-45 REN-150 REN-500 RES-10 RES-50 RES-175 RES-600 REN-10 REN-50 REN-175 REN-600 RES-12 RES-60 RES-200 — Carton Quantity and Weight Catalog Number Carton Quantity and Weight Carton Qty Weight* Lbs. Kg. REN 1–30 10 0.55 0.249 REN 35–65 10 1.40 REN 70–100 5 2.3 REN 110–200 1 1.09 REN 225–400 1 2.66 REN 450–600 *Weight per carton. 1 3.13 Catalog Number Carton Qty Weight* Lbs. Kg. RES 1–30 10 0.18 0.082 0.634 RES 35–60 10 0.36 0.163 1.043 RES 70–100 5 4.16 1.886 0.494 RES 110–200 1 1.83 0.830 1.206 RES 225–400 1 3.73 1.690 1.419 RES 450–600 *Weight per carton. 1 3.75 1.701 FUSE LINKS LKN SUPER-LAG –– 250 VOLTS AC LKS SUPER-LAG –– 600 VOLTS AC Catalog Numbers and Ampere Ratings Catalog Numbers and Ampere Ratings LKN-1 LKN-10 LKN-60 LKN-175 LKS-1 LKS-10 LKS-50 LKS-200 LKN-1-1/2 LKN-12 LKN-65 LKN-200 LKS-2 LKS-12 LKS-60 LKS-225 LKN-2 LKN-15 LKN-70 LKN-225 LKS-2-1/2 LKS-15 LKS-70 LKS-250 LKN-3 LKN-20 LKN-75 LKN-250 LKS-3 LKS-17-1/2 LKS-80 LKS-300 LKN-4 LKN-25 LKN-80 LKN-300 LKS-4 LKS-20 LKS-90 LKS-350 LKN-5 LKN-30 LKN-90 LKN-350 LKS-5 LKS-25 LKS-100 LKS-400 LKN-6 LKN-35 LKN-100 LKN-400 LKS-6 LKS-30 LKS-110 LKS-450 LKN-7 LKN-40 LKN-110 LKN-450 LKS-7 LKS-35 LKS-125 LKS-500 LKN-8 LKN-45 LKN-125 LKN-500 LKS-8 LKS-40 LKS-150 LKS-600 LKN-9 LKN-50 LKN-150 LKN-600 LKS-9 LKS-45 LKS-175 — Carton Quantity and Weight Catalog Number Carton Quantity and Weight Carton Qty Weight* Lbs. Kg. Catalog Number LKN 1–30 20 0.05 0.02 LKN 35–65 20 0.20 LKN 70–100 10 0.20 LKN 110–200 5 LKN 225–400 LKN 450–600 *Weight per carton. 11-27-00 Carton Qty Weight* Lbs. Kg. LKS 1–30 20 0.05 0.02 0.09 LKS 35–60 20 0.02 0.09 0.09 LKS 65–100 10 0.02 0.09 0.25 0.11 LKS 110–200 5 0.25 0.11 5 0.55 0.25 LKS 225–400 5 0.55 0.25 2 0.32 0.15 LKS 450–600 *Weight per carton. 2 0.32 0.15 J00269 Form No. REN/RES Page 2 of 4 BIF Doc #1028 Bussmann® Super-Lag Renewable Fuses and Fuse Links 250 Volts, 1-600 Amps REN and RES (LKN & LKS) Time-Current Characteristic Curves–Average Melt REN SUPER-LAG (250 VOLTS AC) 11-27-00 J00269 Form No. REN/RES Page 3 of 4 BIF Doc #1028 Bussmann® Super-Lag Renewable Fuses and Fuse Links 600 Volts, 1-600 Amps REN and RES (LKN & LKS) Time-Current Characteristic Curves–Average Melt RES SUPER-LAG (600 VOLTS AC) The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 11-27-00 J00269 Form No. REN/RES Page 4 of 4 BIF Doc #1028