INCH-POUND MIL-PRF-19500/544D 27 July 2001 SUPERSEDING MIL-PRF-19500/544C 21 July 2000 The documentation and process conversion measures necessary to comply with this revision shall be completed by 27 October 2001. PERFORMANCE SPECIFICATION SEMICONDUCTOR DEVICE, TRANSISTOR, NPN, SILICON, POWER TYPES 2N5152, 2N5154, 2N5152L, 2N5154L, 2N5152U3, 2N5154U3 JAN, JANTX, JANTXV, JANS, JANHC, AND JANKC This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the performance requirements for NPN, silicon, power transistors for use in high-speed power-switching applications. Four levels of product assurance are provided for each encapsulated device type and two levels of product assurance are provided for each unencapsulated device type as specified in MIL-PRF-19500. 1.2 Physical dimensions. Figure 1 (similar to T0-5 and T0-39), figures 2, 3, and 4 (die dimensions), and figure 5 (U3). 1.3 Maximum ratings. PT PT TA = +25°C TC = +25°C W 2N5152, L 2N5154, L 2N5152U3 2N5154U3 Type Safe operating area Tstg and TJ VCBO VCEO VEBO IC IC (1) Reverse pulse (2) energy W V dc V dc V dc A dc A dc mJ 1 (3) 1 (3) 11.8 (4) 11.8 (4) 100 100 80 80 5.5 5.5 2 2 10 10 15 15 See figure 6 -65 to +200 -65 to +200 1.16 (5) 1.16 (5) 100 (6) 100 (6) 100 100 80 80 5.5 5.5 2 2 10 10 15 15 See figure 6 -65 to +200 -65 to +200 °C (1) This value applies for Pw ≤ 8.3 ms, duty cycle ≤ 1% (2) This rating is based on the capability of the transistors to operate safely in the unclamped inductive load energy test circuit of figure 7. (3) Derate linearly 5.7 mW/°C for TA > +25°C (4) Derate linearly 66.7 mW/°C for TC > +25°C (5) Derate linearly 6.67 mW/°C for TA > +25°C (6) Derate linearly 571 mW/°C for TC > +25°C Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Defense Supply Center Columbus, ATTN: DSCCVAC, Post Office Box 3990, Columbus, OH 43216-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A Distribution statement. Approved for public release; distribution is unlimited. FSC 5961 MIL-PRF-19500/544D 1.4 Primary electrical characteristics at TC = +25°C. Limits hFE2 (1) VCE = 5 V IC = 2.5 A 2N5152 (2) 2N5154 (2) hfe VCE = 5 V IC = 500 mA dc 2N5152 (2) 6 VBE(sat)2 (1) IC = 5 A dc IB = 500 mA dc VCE(sat)2 (1) IC = 5 A dc IB = 500 mA dc Cobo VCB = 10 V dc IE = 0 f = 1` Mhz RθJA RθJC Vdc Vdc pF °C/W °C/W 2N5154 (2) Min 30 70 7 Max (TO-5, TO-39) 90 200 2.2 1.5 250 175 15 Max (U3) 90 200 2.2 1.5 250 150 1.75 (1) Pulsed (see 4.5.1). (2) The limits specified apply to all package outlines unless otherwise stated. 2 APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in section 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATION DEPARTMENT OF DEFENSE MIL-PRF-19500 - Semiconductor Devices, General Specification for. STANDARD DEPARTMENT OF DEFENSE MIL-STD-750 - Test Methods for Semiconductor Devices. (Unless otherwise indicated, copies of the above specifications, standards, and handbooks are available from the Document Automation and Production Services (DAPS), Building 4D (DPM-DODSSP), 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification takes precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2 MIL-PRF-19500/544D Symbol 11 Dimensions Inches Millimeters Min Max Min Max CD 0.305 0.335 7.75 8.51 CH 0.240 0.260 6.10 6.60 HD 0.335 0.370 8.51 9.40 LC 0.200 TP 5.08 TP Notes 6 7 LD 0.016 0.021 0.41 0.53 8, 9 LL .500 .750 12.70 19.05 8, 9, 13 LU 0.016 0.019 0.041 0.48 8, 9 1.27 8, 9 L1 L2 0.050 0.250 Q 6.35 0.050 8, 9 1.27 6 TL 0.029 0.045 0.74 1.14 4, 5 TW 0.028 0.034 0.71 0.86 3 0.25 11 r α P Notes 0.010 45° TP 0.100 45° TP 7 2.54 1, 2, 10, 12, 14 FIGURE 1. Physical dimensions (similar to TO – 5 and TO-39). 3 MIL-PRF-19500/544D NOTES: 1. Dimension are in inches. 2. Metric equivalents are given for general information only. 3. Beyond r (radius) maximum, TW shall be held for a minimum length of 0.011 (0.28 mm). 4. TL measured from maximum HD. 5. Outline in this zone is not controlled. 6. CD shall not vary more than 0.010 (0.25 mm) in zone P. This zone is controlled for automatic handling. 7. Leads at gauge plane 0.054 +0.001 -0.000 inch (1.37 +0.03 -0.00 mm) below seating plane shall be within 0.007 inch (0.18 mm) radius of true position (TP) at maximum material condition (MMC) relative to tab at MMC. The device may be measured by direct methods or by gauge. 8. LU applies between L1 and L2. Dimension LD applies between L2 and L minimum. Diameter is uncontrolled in L1 and beyond LL minimum. 9. All three leads. 10. The collector shall be internally connected to the case. 11. r (radius) applies to both inside corners of tab. 12. In accordance with ANSI Y14.5M, diameters are equivalent to ∅x symbology. 13. For "L" suffix devices, dimension LL is 1.50 (38.10 mm) minimum, 1.75 (19.05 mm) maximum. 14. Lead designation, depending on device type, shall be as follows: Lead number 1 2 3 TO-39 TO-5 Emitter Base Collector Emitter Base Collector FIGURE 1. Physical dimensions (similar to TO – 5 and TO-39) continued. 4 MIL-PRF-19500/544D Dimensions LTR A Inches Millimeters Min Max Min Max 0.117 0.127 2.97 3.23 NOTES: 1. 2. 3. 4. Dimensions are in inches. Metric equivalents are given for general information only. Unless otherwise specified, tolerance is ± 0.005 (0.13 mm). The physical characteristics of the die are; Thickness: 0.008 (0.20 mm) to 0.012 (0.30 mm), tolerance is ± 0.005 (0.13 mm). Top metal: Aluminum, 40,000 Å minimum, 50,000 Å nominal. Back metal: Gold 2,500 Å minimum, 3,000 Å nominal. Back side: Collector. Bonding pad: B = 0.015 (0.38 mm) x 0.0072 (0.183). E = 0.015 (0.38 mm) x 0.0060 (0.152). FIGURE 2. JANHCA and JANKCA die dimensions. 5 MIL-PRF-19500/544D Dimensions LTR A Inches Millimeters Min Max Min Max 0.095 0.105 2.41 2.66 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is ±0.005 (0.13 mm). 4. The physical characteristics of the die are; 5. Thickness: 0.0078 (0.198 mm) nominal, tolerance is ±0.005 (0.13 mm). Top metal: Aluminum, 25,000 Å minimum, 33,000 Å nominal. Back metal: Gold 1,500 Å minimum, 2,500 Å nominal. Back side: Collector. Bonding pad: 0.012 (0.305 mm) min. x .030 (0.761 mm) minimum. FIGURE 3. JANHCB and JANKCB die dimensions. 6 MIL-PRF-19500/544D 1. 2. 3. 4. Die size. Die thickness Top metal Back metal 5. Backside 6. Bonding pad 0.120 x 0.120 inches ±0.002 inches 0.010 ±0.0015 inches nominal Aluminum, 30,000Å minimum, 35,000Å nominal A. Al/Ti/Ni/Ag 12kÅ/3kÅ/7kÅ/7kÅ minimal, 15kÅ/5kÅ/10kÅ/10kÅ nominal B. Gold 2500Å minimum, 3000Å nominal Collector B = 0.052 x 0.012 inches, E = 0.084 x 0.012 inches FIGURE 4. JANHCC and JANKCC die dimensions. 7 MIL-PRF-19500/544D Symbol Dimensions Inches BL BW CH LH LW1 LW2 LL1 LL2 LS1 LS2 Q1 Q2 TERM 1 TERM 2 TERM 3 Min 0.395 0.291 0.1085 0.010 0.281 0.090 0.220 0.115 Millimeters Max 0.405 0.301 0.1205 0.020 0.291 0.100 0.230 0.125 Min 10.04 7.40 2.76 0.25 7.14 2.29 5.59 2.93 0.150 BSC 0.075 BSC 0.030 0.030 Max 10.28 7.64 3.06 0.51 7.41 2.54 5.84 3.17 3.81 BSC 1.91 BSC ----- 0.762 0.762 ----- Drain Gate Source NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Dimensions and tolerances shall be in accordance with ANSI Y14.5M-1982. 4. Terminal 1 - collector, terminal 2 - base, terminal 3 – emitter. SCHEMATIC 1 3 2 FIGURE 5. Physical dimensions and configuration for surface mount (U3). 8 MIL-PRF-19500/544D 3. REQUIREMENTS 3.1 General. The requirements for acquiring the product described herein shall consist of this document and MIL-PRF-19500. 3.2 Qualification. Devices furnished under this specification shall be products that are manufactured by a manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturer’s (QML list) before contract award (see 4.2 and 6.3). 3.3 Abbreviations, symbols, and definitions. Abbreviations, symbols, and definitions used herein shall be as specified in MIL-PRF-19500. 3.4 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-19500 and figure 1 (Similar to T0-5 and T0-39), and figures 2, 3, 4 (die dimensions) for JANHC and JANKC, and figure 5 (U3) 3.4.1 Current density. Current density of internal conductors shall be as specified in MIL-PRF-19500. 3.4.2 Lead finish. Lead finish shall be solderable as defined in MIL-PRF-19500, MIL-STD-750, and herein. Where a choice of lead finish is desired, it shall be specified in the acquisition document (see 6.2). 3.5 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in 1.3, 1.4, and table I herein. 3.6 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table I herein. 3.7 Marking. Marking shall be in accordance with MIL-PRF-19500. 3.8 Workmanship. Semiconductor devices shall be processed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance. 4 VERIFICATION 4.1 Classification of inspections. The inspection requirements specified herein are classified as follows: a. Qualification inspection (see 4.2). b. Screening (see 4.3). c. Conformance inspection (see 4.4). 4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-19500 and as specified herein. 4.2.1 JANHC and JANKC qualification. JANHC and JANKC qualification inspection shall be in accordance with MIL-PRF-19500. 9 MIL-PRF-19500/544D 4.3. Screening (JANS, JANTX, and JANTXV levels only). Screening shall be in accordance with table IV of MIL-PRF-19500 and as specified herein. The following measurements shall be made in accordance with table I herein. Devices that exceed the limits of table I herein shall not be acceptable. Screen (see table IV of MIL-PRF-19500) Measurement JANS levels JANTX and JANTXV levels 1a 1b Not required Required Not required Required for JANTXV only 2 Optional Optional 3a 3b 3c Required Not applicable Thermal response (see 4.5.3) Required Not applicable Thermal response (see 4.5.3) 4 Required Optional 5 Required Not applicable 7a and 7b Required Required 8 Required Not required 9 ICES1 and hFE2 Not applicable 10 48 hours minimum 48 hours minimum 11 ICES1 and hFE2; ∆ICES1 = 100 percent of initial value or100 nA dc, whichever is greater. ∆hFE2 = ± 20 percent. ICES1 and hFE2 12 See 4.3.2 See 4.3.2 13 Subgroup 2 and 3 of table I herein; ∆ICES1 = 100 percent of initial value or 100 nA dc, whichever is greater. ∆hFE2 = ± 20 percent. Subgroup 2 of table I herein; ∆ICES1 = 100 percent of initial value or 100 nA dc, whichever is greater. ∆hFE2 = ± 20 percent. 14a and 14b Optional Optional 15 Required Not required 16 Required Not required 4.3.1. Screening (JANHC and JANKC). Screening of JANC die shall be in accordance with MIL-PRF-19500 Burnin duration for the JANKC level follows JANS requirements; the JANHC follows JANTX requirements. 10 MIL-PRF-19500/544D 4.3.2. Power burn-in conditions. Power burn-in conditions are as follows: VCB = 10 - 30 Vdc, TA = room ambient as defined in the general requirements of paragraph 4.5 of MIL-STD-750. Power shall be applied to the device to achieve a Junction temperature, TJ=135 °C minimum and a minimum PD = 75 percent of PT maximum rated as defined in 1.3 herein. 4.4. Conformance inspection. Conformance inspection shall be as specified herein. 4.4.1. Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500 and table I herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. 4.4.2. Group B inspection. Group B inspection shall be conducted in accordance with the test and conditions specified for subgroup testing in table VIa (JANS) and table VIb (JAN, JANTX, and JANTXV) of MIL-PRF-19500 and 4.4.2.1 and 4.4.2.2 herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta measurements shall be in accordance with table II herein. 4.4.2.1. Group B inspection table VIa (JANS) of MIL-PRF-19500. Subgroup Method Conditions B4 1037 VCB = 10 - 30 Vdc. B5 1027 VCB = 10 V dc; TA < +125°C ±25°C for 96 hours with PT adjusted according to the chosen TA to give TJ = +275°C minimum. Optionally the test may be performed for a minimum of 216 hours with PT adjusted to achieve a TJ = +225°C minimum; sample size = 45, c = 0. In this case the ambient temperature shall be adjusted such that a minimum 75 percent of maximum rated PT (see1.3) is applied to the device under test. (NOTE: If a failure occurs, resubmission shall be at the test conditions of the original sample.) B6 3131 See 4.5.2. 4.4.2.2. Group B inspection, (JAN, JANTX, and JANTXV). Separate samples may be used for each step. In the event of a group B failure, the manufacturer may pull a new sample at double size from either the failed assembly lot or from another assembly lot from the same wafer lot. If the new “assembly lot” option is exercised, the failed assembly lot shall be scrapped. Step Method Conditions 1 1039 Steady-state life: Test condition B, 340 hours min., VCB = 10 - 30 V dc, power shall be applied to achieve TJ = +175°C minimum using a minimum of PD = 75 percent of maximum rated PT as defined in 1.3. n = 45 devices, c = 0. 2 1039 The steady-state life test of step 1 shall be extended to 1,000 Hrs for each die design. Samples shall be selected from a wafer lot every twelve months of wafer production. Group B, step 2 shall not be required more than once for any single wafer lot. n = 45, c = 0. 3 1032 High-temperature life (non-operating), t = 340 hours, TA = +200°C. n = 22, c = 0. 11 MIL-PRF-19500/544D 4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following requirements: a. For JAN, JANTX, and JANTXV samples shall be selected randomly from a minimum of three wafers (or from each wafer in the lot) from each wafer lot. See MIL-PRF-19500. b. Must be chosen from an inspection lot that has been submitted to and passed group A, subgroup 2, conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high temperature, the samples for life test (group B for JAN, JANTX, and JANTXV) may be pulled prior to the application of final lead finish. 4.4.3. Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions specified for subgroup testing in table VII of MIL-PRF- and as follows. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta measurements shall be in accordance with table II herein. Subgroup Method Conditions C2 2036 Test condition E, (not applicable for U3 packages). C6 1037 VCB = 10 - 30 V dc, 6,000 cycles. 4.4.4. Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for subgroup testing in table IX of MIL-PRF-19500 and as follows. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta measurements shall be in accordance with table II herein. Subgroup Method Condition Sampling plan E1 1051 500 cycles 45 devices, c = 0 E2 1039 Condition A, 500 hours 45 devices, c = 0 E3 E4 E5 Not applicable 3131 RθJC = 15°C/W maximum (TO-5,and TO-39) RθJC = 1.75°C/W maximum (U3) See 4.5.2 22 devices, c = 0 Not applicable 4.5. Methods of inspection and test. Methods of inspection and test shall be as specified in the appropriate tables and as follows: 4.5.1. Pulse measurements. Conditions for pulse measurements shall be as specified in section 4 of MIL-STD-750. 4.5.2. Thermal resistance. Thermal resistance measurements shall be conducted in accordance with method 3131 of MIL-STD-750. The following details shall apply: a. Collector current magnitude during power application shall be 500 mA dc minimum. b. Collector to emitter voltage magnitude shall be 10 V dc. c. Reference temperature measuring point shall be the case. d. Reference temperature measuring point shall be within the range +25°C ≤ TR ≤ +35°C. The chosen reference temperature shall be recorded before the test is started. e. Mounting arrangement shall be with heat sink to case. f. Maximum limit of RθJC shall be 15.0°C/W for (TO-5, andTO-39) and 1.75°C/W for U3. 12 MIL-PRF-19500/544D 4.5.3. Thermal response (∆VBE measurements). The ∆VBE measurements shall be performed in accordance with method 3131 of MIL-STD-750. The ∆VBE conditions (IH and VH) and maximum limit shall be derived by each vendor. The chosen ∆VBE measurement and conditions for each device in the qualification lot shall be submitted in the qualification report and a thermal response curve shall be plotted. The chosen ∆VBE shall be considered final after the manufacturer has had the opportunity to test five consecutive lots. One-hundred percent safe operating area (SOA) testing may be performed in lieu of thermal response testing herein provided that the appropriate conditions of temperature, time, current, and voltage to achieve die attach integrity are approved by the qualifying activity. The following parameter measurements shall apply: a. IM measurement ......................................................................... 10 mA. b. VCE measurement voltage ......................................................... 16 V (same as VH). c. IH collector heating current ......................................................... 1 A minimum. d. VH collector-emitter heating voltage ........................................... 16 V minimum. e. tH heating time ............................................................................ 10 ms. f. tMD measurement delay time ...................................................... 50 µs maximum. g. tSW sample window time ............................................................ 10 µs maximum. 13 MIL-PRF-19500/544D TABLE I. Group A inspection. Inspection 1/ MIL-STD-750 Method Symbol Conditions Limits Min Unit Max Subgroup 1 2/ Visual and mechanical examination 3/ 2071 n = 45 devices, c = 0 Solderability 3/, 4/ 2026 n = 15 leads, c = 0 Resistance to solvents 3/, 4/, 5/ 1022 n = 15 devices, c = 0 Temp Cycling 3/, 4/ 1051 Test condition C, 25 cycles. n = 22 devices, c = 0 Heremetic Seal 4/ Fine leak Gross leak 1071 n = 22 devices, c = 0 Electrical measurements 4/ Bond strength 3/, 4/ Group A, subgroup 2 2037 Precondition TA = +250°C at t = 24 hrs or TA = +300°C at t = 2 hrs n = 11 wires, c = 0 Breakdown voltage, collector to emitter 3011 Bias condition D, IC = 100 mA dc; IB = 0, Pulsed (see 4.5.1) V(BR)CEO Collector to emitter cutoff current 3041 Bias condition C, VCE = 60 V dc; VBE = 0 ICES1 1.0 µA dc Collector to emitter cutoff current 3041 Bias condition C, VCE = 100 V dc; VBE = 0 ICES2 1.0 mA dc Collector to emitter cutoff current 3041 Bias condition D, VCE = 40 V dc, IB = 0 ICEO 50 µA dc Emitter to base cutoff current 3061 Bias condition D, VEB = 4 V dc, IC = 0 IEBO1 1.0 µA dc Emitter to base cutoff current 3061 Bias condition D, VEB = 5.5 V dc, IC = 0 IEBO2 1.0 mA dc Forward current transfer ratio 3076 VCE = 5 V dc, IC = 50 mA dc hFE1 Subgroup 2 2N5152 2/ 2N5154 See footnote at end of table. 80 20 50 14 V dc MIL-PRF-19500/544D TABLE I. Group A inspection - Continued. Inspection 1/ MIL-STD-750 Symbol Method Conditions 3076 VCE = 5 V dc, IC = 2.5 A dc, pulsed (see 4.5.1) Limits Unit Min Max 30 70 90 200 Subgroup 2 Continued. Forward current transfer ratio hFE2 2N5152 2/ 2N5154 Forward current transfer ratio 3076 VCE = 5 V dc, IC = 5 A dc, pulsed (see 4.5.1) hFE3 2N5152 2/ 2N5154 20 40 Base-emitter voltage (nonsaturated) 3066 Test condition B, VCE = 5 V dc, IC = 2.5 A dc, pulsed (see 4.5.1) VBE 1.45 V dc Base-emitter saturation voltage 3066 Test condition A, IC = 2.5 A dc, IB = 250 mA dc, pulsed (see 4.5.1) VBE(sat)1 1.45 V dc Base-emitter saturation voltage 3066 Test condition A, IC = 5 A dc, IB = 500 mA dc, pulsed (see 4.5.1) VBE(sat)2 2.2 V dc Collector-emitter saturation voltage 3071 IC = 2.5 A dc, IB = 250 mA dc, pulsed (see 4.5.1) VCE(sat)1 0.75 V dc Collector-emitter saturation voltage 3071 IC = 5 A dc, IB = 500 mA dc, pulsed (see 4.5.1) VCE(sat)2 1.5 V dc ICEX 500 µA dc Subgroup 3 High temperature operation: Collector to emitter cutoff current TC = +150°C 3041 Low temperature operation Forward - current transfer ratio 2N5152 2/ 2N5154 Bias condition A, VCE = 60 V dc, VBE = -2 V dc TC = -55°C 3076 VCE = 5 V dc, IC = 2.5 A dc, pulsed (see 4.5.1) See footnote at end of table. 15 hFE4 15 25 MIL-PRF-19500/544D TABLE I. Group A inspection - Continued. Inspection 1/ MIL-STD-750 Method Symbol Conditions Limits Min Unit Max Subgroup 4 Common-emitter, smallsignal, short-circuit, forward-current transfer ratio 3206 VCE = 5 V dc IC = 100 mA dc, f = 1 kHz hfe 2N5152 2/ 2N5154 Magnitude of commonemitter, small-signal short-circuit, forwardcurrent, transfer ratio 20 50 3306 VCE = 5 V dc, IC = 500 mA dc, f = 10 MHz | hfe| 2N5152 2/ 2N5154 Open-circuit output capacitance 6 7 3236 Switching time VCB = 10 V dc, IE = 0, f = 1 MHz IC = 5 A dc, IB1 = 500 mA dc IB2 = -500 mA dc VBE(off) = 3.7 V dc RL = 6Ω; (See figure 8) Subgroup 5 Safe operating area (d.c.) 3051 Pre-pulse condition for each test: VCE = 0, IC = 0, TC = +25°C Pulse condition for each test tp = 1 sec. 1 cycle, TC = +25°C, (see figure 6) Test # 1 VCE = 5.0 V dc, IC = 2 A dc for TO39/5 VCE = 5.8 V dc, IC = 2 A dc for U3, unheatsunk (see note 3) or TBD Test # 2 VCE = 32 V dc, IC = 310 mA dc for TO39/5 VCE = 32 V dc, IC = 360 mA dc for U3, unheatsunk (see note 3) or TBD See footnote at end of table. 16 Cobo 250 pf ton 0.5 µs ts 1.4 µs tf toff 0.5 1.5 µs µs MIL-PRF-19500/544D TABLE I Group A inspection - Continued. Inspection 1/ MIL-STD-750 Method Conditions Symbol Limits Min Unit Max Subgroup 5 –continued Test # 3 VCE = 80 V dc, IC = 12.5 mA dc for TO39/5 VCE = 80 V dc, IC = 14.5 mA dc for U3, unheatsunk (see note 3) or TBD Safe operating area (unclamped inductive) TC = +25°C, RBB1 = 10Ω RBB2 = 100Ω, L = 0.3 mH, RL = 0.1Ω, VCC = 10 V dc, VBB1 = 10 V dc, VBB2 = 4 V dc, ICM = 10 A dc, (see figure 7) End-point electrical measurements See table I, subgroup 2 Subgroups 6 and 7 Not applicable 1/ For sampling plan see MIL-PRF-19500. 2/ For resubmission of failed subgroup A1, double the sample size of the failed test or sequence of tests. A failure in group A, subgroup 1 shall not require retest of the entire subgroup. Only the failed test shall be rerun upon submission. 3/ Separate samples may be used. 4/ Not required for JANS devices. 5/ Not required for laser marked devices. 17 MIL-PRF-19500/544D TABLE II. Groups B, C and E delta electrical measurements. 1/ 2/ 3/ Step Inspection MIL-STD-750 Method 1. Forward current transfer ratio 3076 Symbol Conditions Limits Min IC = 2.5 A dc, VCE = 5 V dc, Pulsed (see 4.5.1) ∆hFE2 Unit Max ± 20percent change from initial reading. 1/ The delta measurements for table VIa (JANS) of MIL-PRF-19500 are as follows: Subgroups 4 and 5, see table II herein, step 1. 2/ The delta measurements for table VIb (JAN, JANTX and JANTXV) of MIL-PRF-19500 are as follows: All subgroups, see table II herein, step 1. 3/ The delta measurements for table VII of MIL-PRF-19500 are as follows: Subgroup 6, see table II herein, step 1. 4/ The delta measurements for 4.4.4 are as follows: Subgroups 1 and 2, see table II herein, step 1. 18 MIL-PRF-19500/544D FIGURE 6. Maximum safe operating area. RBB1 = 10Ω RBB2 = 100Ω L = 0.3 mH RL = 0.1Ω VCC = 10 V dc ICM = 10 A VBB1 = 10 V dc VBB2 = 4 V dc FIGURE 7. Unclamped inductive load energy test circuit. 19 MIL-PRF-19500/544D NOTES: 1. Vgen is a -30 pulse (from 0 V) into a 50 ohm termination. 2. The Vgen waveform is supplied by a generator with the following characteristics: tr ≤ 15 ns, tf ≤ 15 ns, Zout = 50 ohm, duty cycle ≤ 2%, tw = 20 µs. 3. Waveforms are monitored on an oscilloscope with the following characteristics: tr ≤ 1 ns, Rin ≥ 10 Mohm, Cin ≤ 11.5 pF. 4. Resistors must be noninductive types. 5. The dc power supplies may require additional bypassing in order to minimize ringing. 6. An equivalant drive circuit may be used FIGURE 8. Switching time test circuit. 20 MIL-PRF-19500/544D 5. PACKAGING 5.1. Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel, these personnel need to contact the responsible packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Points' packaging activity within the Military Department or Defense Agency, or within the Military Departments' System Command. Packaging data retrieval is available from the managing Military Departments' or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity. 6. NOTES (This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.) 6.1 Intended use. The notes specified in MIL-PRF-19500 are applicable to this specification. 6.2 Acquisition requirements. Acquisition documents must specify the following: a. Title, number, and date of this specification. b. Issue of DODISS to be cited in the solicitation, and if required, the specific issue of individual documents referenced (see 2.2.1). c. The lead finish as specified (see 3.4.2). d. Type designation and quality assurance level. e. Packaging requirements (see 5.1). 6.3 Qualification. With respect to products requiring qualification, awards will be made only for products which are, at the time of award of contract, qualified for inclusion in Qualified Manufacturers List QML-19500 whether or not such products have actually been so listed by that date. The attention of the contractors is called to these requirements, and manufacturers are urged to arrange to have the products that they propose to offer to the Federal Government tested for qualification in order that they may be eligible to be awarded contracts or orders for the products covered by this specification. Information pertaining to qualification of products may be obtained from Defense Supply Center, Columbus, ATTN: DSCC-VQE, P.O. Box 3990, Columbus, OH 43216-5000. 6.4. Suppliers of JANHC and JANKC die. The qualified JANHC and JANKC suppliers with the applicable letter version (example JANHCA2N5152) will be identified on the QML. JANHC and JANKC ordering information PIN Manufacturer 33178 34156 43611 2N5152 2N5154 JANHCA2N5152 JANHCA2N5154 JANHCB2N5152 JANHCB2N5154 JANHCC2N5152 JANHCC2N5154 2N5152 2N5154 JANKCA2N5152 JANKCA2N5154 JANKCB2N5152 JANKCB2N5154 JANKCC2N5152 JANKCC2N5154 6.5. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extensiveness of the changes. 21 MIL-PRF-19500/544D Custodians: Air Force - 11 Navy NW NASA - NA DLA – CC Preparing activity: DLA – CC (Project 5961-2398) Review activity: Air Force - 19 22 STANDARDIZATION DOCUMENT IMPROVEMENT PROPOSAL INSTRUCTIONS 1. The preparing activity must complete blocks 1, 2, 3, and 8. In block 1, both the document number and revision letter should be given. 2. The submitter of this form must complete blocks 4, 5, 6, and 7. 3. The preparing activity must provide a reply within 30 days from receipt of the form. NOTE: This form may not be used to request copies of documents, nor to request waivers, or clarification of requirements on current contracts. Comments submitted on this form do not constitute or imply authorization to waive any portion of the referenced document(s) or to amend contractual requirements. I RECOMMEND A CHANGE: 1. DOCUMENT NUMBER MIL-PRF-19500/544D 2. DOCUMENT DATE 010727 3. DOCUMENT TITLE SEMICONDUCTOR DEVICE, TRANSISTOR, NPN, SILICON, POWER TYPES 2N5152, 2N5154, 2N5152L, 2N5154L, 2N5152U3 2N5154U3 JAN, JANTX, JANTXV, JANS, JANHC, AND JANKC 4. NATURE OF CHANGE (Identify paragraph number and include proposed rewrite, if possible. Attach extra sheets as needed.) 5. REASON FOR RECOMMENDATION 6. SUBMITTER a. NAME (Last, First, Middle initial) c. ADDRESS (Include Zip Code) b. ORGANIZATION d. TELEPHONE (Include Area Code) COMMERCIAL DSN FAX EMAIL 7. DATE SUBMITTED 8. PREPARING ACTIVITY a. Point of Contact Alan Barone c. ADDRESS Defense Supply Center Columbus, ATTN: DSCC-VAC, P. O. Box 3990, Columbus, OH 43216-5000 DD Form 1426, Feb 1999 (EG) b. TELEPHONE Commercial DSN FAX EMAIL 614-692-0510 850-0510 614-692-6939 [email protected] IF YOU DO NOT RECEIVE A REPLY WITHIN 45 DAYS, CONTACT: Defense Standardization Program Office (DLSC-LM) 8725 John J. Kingman, Suite 2533, Fort Belvoir, VA 22060-6221 Telephone (703) 767-6888 DSN 427-6888 Previous editions are obsolete WHS/DIOR, Feb 99