ACT-D1M96S High Speed 96 MegaBit 3.3V Synchronous DRAM Multichip Module Features ■ ■ ■ ■ ■ ■ ■ ■ 6 Low Power Micron 1M X 16 Synchronous Dynamic Random Access Memory Chips in one MCM User Configureable as "2" Independent 512K X 48 X 2 Banks High-Speed, Low-Noise, Low-Voltage TTL (LVTTL) Interface 3.3-V Power Supply (±10% Tolerance) Separate Logic and Output Driver Power Pins Two Banks for On-Chip Interleaving (Gapless Accesses) Up to 50-MHz Data Rates CAS Latency (CL) Programmable to 2 Cycles From Column-Address Entry ■ ■ ■ ■ ■ ■ ■ ■ Burst Length Programmable to 4 or 8 Pipeline Architecture Cycle-by-Cycle DQ-Bus Write Mask Capability With Upper and Lower Byte Control Chip Select and Clock Enable for Enhanced-System Interfacing Serial Burst Sequence Auto-Refresh 4K Refresh (Total for Both Banks) 200-lead CQFP, cavity-up package General Description The ACT-D1M96S device is a high-speed 96Mbit synchronous dynamic random access memory (SDRAM) organized as 2 independent 512K X 48 X 2 banks. All inputs and outputs of the ACT-D1M96S are compatible with the LVTTL interface. All inputs and outputs are synchronized with the CLK input to simplify system design and enhance use with high-speed microprocessors and caches. BLOCK DIAGRAM S E C T I O N A CS1 CLK1 CKE1 DQMU1 DQML1 RAS1 CAS1 WE1 A0-A11 12 1M X 16 or 512K X 16 X 2 Banks BANK T 1M X 16 or 512K X 16 X 2 Banks 1M X 16 or 512K X 16 X 2 Banks BANK B 16 DQ 0-15 S E C T I O N B CS2 CLK2 CKE2 DQMU2 DQML2 RAS2 CAS2 WE2 BA0-BA11 BANK T 16 DQ 16-31 16 DQ 32-47 12 1M X 16 or 512K X 16 X 2 Banks 1M X 16 or 512K X 16 X 2 Banks 1M X 16 or 512K X 16 X 2 Banks BANK B 16 DQ48-63 16 DQ 64-79 16 DQ80-95 eroflex Circuit Technology - Advanced Multichip Modules © SCD3369-1 REV C 5/31/00 Operation complete (as determined by the programmed-burst length), the outputs are in the high-impedance state until the next read access is initiated. All inputs to the ACT-D1M96S SDRAM are latched on the rising edge of the system (synchronous) clock. The outputs, DQ0-DQ95, also are referenced to the rising edge of CLK. The ACT-D1M96S has two banks in each section that are accessed independently. A bank must be activated before it can be accessed (read from or written to). Refresh cycles refresh both banks alternately. Five basic commands or functions control most operations of the ACT-D1M96S: ● Bank activate/row-address entry ● Column-address entry/write operation ● Column-address entry/read operation ● Bank deactivate ● Auto-refresh Additionally, operations can be controlled by three methods: ● Chip select (CS) to select/ deselect the devices ● DQMx to enable/mask the DQ signals on a cycle-by-cycle basis ● CKE to suspend (or gate) the CLK input The device contains a mode register that must be programmed for proper operation. Table 1 through Table 3 show the various operations that are available on the ACT-D1M96S. These truth tables identify the command and/or operations and their respective mnemonics. Each truth table is followed by a legend that explains the abbreviated symbols. An access operation refers to any read or write command in progress at cycle n. Access operations include the cycle upon which the read or write command is entered and all subsequent cycles through the completion of the access burst. Latency The beginning data-out cycle of a read burst can be programmed to occur two CLK cycles after the read command. The delay between the READ command and the beginning of the output burst is known as CAS latency. After the initial output cycle begins, the data burst occurs at the CLK frequency without any intervening gaps. There is no latency for data-in cycles (write latency). The first data-in cycle of a write burst is entered at the same rising edge of CLK on which the WRT command is entered. The write latency is fixed and is not determined by the mode-register contents. Two-Bank Operation The ACT-D1M96S contains two independent banks that can be accessed individually or in an interleaved fashion. Each bank must be activated with a row address before it can be accessed. Each bank then must be deactivated before it can be activated again with a new row address. The bank-activate/row-address-entry command (ACTV) is entered by holding RAS low, CAS high, WE high, and A11 valid on the rising edge of CLK. A bank can be deactivated either automatically during a READ-P or a WRT-P command or by use of the deactivate-bank (DEAC) command. Both banks can be deactivated at once by use of the DCAB command (see Table 1 and the section on bank deactivation). Two-Bank Row-Access Operation The two-bank feature allows access of information on random rows at a higher rate of operation than is possible with a standard DRAM, by activating one bank with a row address and, while the data stream is being accessed to/from that bank, activating the second bank with another row address. When the data stream to or from the first bank is complete, the data stream to or from the second bank can begin without interruption. After the second bank is activated, the first bank can be deactivated to allow the entry of a new row address for the next round of accesses. In this manner, operation can continue in an interleaved fashion. Burst Sequence All data for the ACT-D1M96S is written or read in a burst fashion, that is, a single starting address is entered into the device and then the ACT-D1M96S internally accesses a sequence of locations based on that starting address. After the first access some of the subsequent accesses can be at preceding as well as succeeding column addresses, depending on the starting address entered. This sequence is programmed to follow a serial burst (see Table 4 and 5). The length of the burst can be programmed is 4 or 8. After a read burst is Aeroflex Circuit Technology 2 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 DQ80-87 and DQMU controls DQ8-15, DQ24-31, DQ40-47, DQ56-63, DQ72-79, and DQ88-95. The application of DQMx to a write burst has no latency (nDID = 0 cycle). During a write burst, if DQMx is held high on the rising edge of CLK, the data-input is ignored on that cycle. Two-Bank Column-Access Operation The availability of two banks allows the access of data from random starting columns between banks at a higher rate of operation. After activating each bank with a row address (ACTV command), A11 can be used to alternate READ or WRT commands between the banks to provide gapless accesses at the CLK frequency, provided all specified timing requirements are met. CLK-Suspend For normal device operation, CKE should be held high to enable CLK. If CKE goes low during the execution of a READ (READ-P) or WRT (WRT-P) operation, the DQ bus occurring at the immediate next rising edge of CLK is frozen at its current state, and no further inputs are accepted until CKE returns high. This is known as a CLK-suspend operation, and its execution indicates a HOLD command. The device resumes operation from the point when it was placed in suspension, beginning with the second rising edge of CLK after CKE returns high. Bank Deactivation (Precharge) Both banks can be deactivated (placed in precharge) simultaneously by using the DCAB command. A single bank can be deactivated by using the DEAC command. The DEAC command is entered identically to the DCAB command except that A10 must be low and A11 used to select the bank to be precharged as shown in Table 1. A bank can be deactivated automatically by using A10 during a read or write command. If A10 is held high during the entry of a read or write command, the accessed bank (selected by A11) is deactivated automatically upon completion of the access burst. If A10 is held low during the entry of a read or write command, that bank remains active following the burst. The read and write commands with automatic deactivation are signified as READ-P and WRT-P. Setting the Mode Register The ACT-D1M96S contains a mode register in each chip that must be programmed with the CAS latency, the burst type, and the burst length. This is accomplished by executing a mode-register set (MRS) command with the information entered on the address lines A0-A9. A logic 0 must be entered on A7 and A8, but A10 and A11 are don’t-care entries for the ACT-D1M96S. When A9 = 0, the write-burst length is defined by A0-A2. Figure 1 shows the valid combinations for a successful MRS command. Only valid addresses allow the mode register to be changed. If the addresses are not valid, the previous contents of the mode register remain unaffected. The MRS command is executed by holding RAS, CAS, and WE low and the input mode word valid on A0-A9 on the rising edge of CLK (see Table 1). The MRS command can be executed only when both banks are deactivated. Chip Select (CS) CS can be used to select or deselect the ACT-D1M96S for command entry, which might be required for multiple-memory-device decoding. If CS is held high on the rising edge of CLK (DESL command), the device does not respond to RAS, CAS, or WE until the device is selected again by holding CS low on the rising edge of CLK. Any other valid command can be entered simultaneously on the same rising CLK edge of the select operation. The device can be selected/deselected on a cycle-by-cycle basis (see Table 1 and Table 2). The use of CS does not affect an access burst that is in progress; the DESL command can only restrict RAS, CAS, and WE input to the ACT-D1M96S. Refresh The ACT-D1M96S must be refreshed at intervals not exceeding tREF (see timing requirements) or data cannot be retained. Refresh can be accomplished by performing a read or write access to every row in both banks or 4096 auto-refresh (REFR) commands. Regardless of the method used, refresh must be accomplished before tREF has expired. Data Mask The mask command or its opposite, the data-in enable (ENBL) command (see Table 3), is performed on a cycle-by-cycle basis to gate any data cycle within a write burst. DQML controls DQ0-7, DQ16-23, DQ32-39, DQ48-55, DQ64-71, Aeroflex Circuit Technology 3 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 Auto Refresh (REFR) Before performing a REFR, both banks of all 6 chips must be deactivated (placed in precharge). To enter a REFR command, RAS and CAS must be low and WE must be high upon the rising edge of CLK (see Table 1). The refresh address is generated internally such that, after 4096 REFR commands, both banks of all 6 chips of the ACT-D1M96S have been refreshed. The external address and bank select (A11) are ignored. The execution of a REFR command automatically deactivates both banks upon completion of the internal auto-refresh cycle, allowing consecutive REFR-only commands to be executed, if desired, without any intervening DEAC commands. The REFR commands do not necessarily have to be consecutive, but all 4096 must be completed before tREF expires. Power Up Initialization Device initialization should be performed after a power up to the full VCC level. After power is established, a 200µs interval is required (with no inputs other than CLK). After this interval, both banks of the device must be deactivated. Eight REFR commands must be performed, and the mode register must be set to complete the device initialization. General Information for AC Timing Measurements All specifications referring to READ commands are also valid for READ-P commands unless otherwise noted. All specifications referring to WRT commands are also valid for WRT-P commands unless otherwise noted. All specifications referring to consecutive commands are specified as consecutive commands for the same bank unless otherwise noted. Note: For all pin references in the General Description, both sections apply. For example, A11 signals also apply for BA11 signals. For additional Detail Information regarding the operation of the individual chip (MT48LC1M16A1) see Micron’s 524,288-WORD BY 16-BIT BY 2-BANK SYNCHRONOUS DYNAMIC RANDOM-ACCESS MEMORY Datasheet Revision 8/99 or contact the Aeroflex Sales Department. Aeroflex Circuit Technology 4 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 BA11 BA10 BA9 BA8 BA7 BA6 BA5 BA4 BA3 BA2 BA1 BA0 0 0 Reserved 0 = Serial Register Bits Register Bit A9/ BA9 Write Burst Length A2 - A0 0 BA2 - BA0 † Register Bits A6 A5 A4 BA6 BA5 BA4 0 1 0 CAS Latency † Burst Length A2 A1 A0 BA2 BA1 BA0 0 1 0 4 0 1 1 8 2 NOTES: † All other combinations are reserved. Figure 1 – Mode Register Programming 3.3 V AC Test Conditions 1200 Ω Output 10 pF 870 Ω Parameter Input Pulse Level Input Rise and Fall Input and Output Timing Reference Typical 0.4 – 2.4 5 1.5 Units V ns V Figure 2 – LVTTL-Load Circuit Aeroflex Circuit Technology 5 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 Table 1 — Basic Command Truth Table State of Bank(s) Command ‡ T = deac Mode register set B = deac † CS1 RAS1 CAS1 WE1 A11 A10 A9-A0 CS2 RAS2 CAS2 WE2 BA11 BA10 BA9-BA0 L L L L X X A8,BA8,A7,BA7 = 0 Mnemonic A9,BA9 = V MRS A6-A0,BA6-BA0 = V Bank deactivate (precharge) X L L H L BS L X DEAC Deactivate all banks (precharge) X L L H L X H X DCAB Bank activate/row-address entry SB = deac L L H H BS V V ACTV Column-address entry/write operation SB = actv L H L L BS L V WRT Column-address entry/write operation with auto-deactivate SB = actv L H L L BS H V WRT-P Column-address entry/read operation SB = actv L H L H BS L V READ Column-address entry/read operation with auto-deactivate SB = actv L H L H BS H V READ-P Burst stop SB = actv L H H L X X X STOP No operation X L H H H X X X NOOP Control-input inhibit/no operation X H X X X X X X DESL L L L H X X X REFR Auto refresh T = deac § B = deac NOTES: † For execution of these commands on cycle n: -CKE (n-1) must be high, or -tCES and nCLE must be satisfied for clock-suspend exit. DQMx(n) is a don’t care. ‡ All other unlisted commands are considered vendor-reserved commands or illegal commands. § Auto-refresh entry requires that all banks be deactivated or in an idle state prior to the command entry. Legend: n = CLK cycle number, L = Logic low, H = Logic high, X = Don’t care, either logic low or logic high, V = Valid, T = Bank T, B = Bank B, actv = Activated, deac = Deactivated, BS = Logic high to select bank T; logic low to select bank B, SB = Bank selected by A11 at cycle n Table 2 — Clock Enable (CKE) Command Truth Table † Command ‡ CLK suspend on cycle (n + 1) CLK suspend exit on cycle (n + 1) State of Bank(s) CKE (n-1) CKE (n) CS RAS CAS WE (n) (n) (n) (n) H L X X X X HOLD L H X X X X — T = access operation¶ B = access operation¶ T = access operation¶ B = access operation¶ Mnemonic NOTES: † For execution of these commands, A0-A11 (n) and DQMx (n) are don’t cares. ‡ All other unlisted commands are considered vendor-reserved commands or illegal commands. ¶ A bank is no longer in an access operation one cycle after the last data-out cycle of a read operation, and two cycles after the last data-in cycle of a write operation. Neither the PDE nor the HOLD command is allowed on the cycle immediately following the last data-in cycle of a write operation. Legend: n = CLK cycle number, L = Logic low, H = Logic high, X = Don’t care, either logic low or logic high, T = Bank T, B = Bank B Aeroflex Circuit Technology 6 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 Table 3 — Data-Mask (DQM) Command Truth Table Command ‡ DQML § State of Bank(s) Data In (n) Data Out (n+2) Mnemonic X N/A Hi-Z — X N/A Hi-Z — L V N/A ENBL H M N/A MASK L N/A V ENBL DQMU (n) T = deac and — B = deac † T = actv and — B = actv (no access operation) ¶ T = Write or Data-in enable B = Write T = Write or Data-in mask B = Write T = Write or Data-out enable B = Write NOTES: † For execution of these commands on cycle n: - CKE (n) must be high, or -t CES and n CLE must be satisfied for clock suspend exit. CS(n), RAS(n), CAS(n), WE(n), and A0-A11 are don’t cares. ‡ All other unlisted commands are considered vendor-reserved commands or illegal commands. § DQML controlsDQ0-7, DQ16-23, DQ32-39, DQ48-55, DQ64-71, DQ80-87 and DQMU controls DQ8-15, DQ24-31, DQ40-47, DQ56-63, DQ72-79, and DQ88-95 ¶ A bank is no longer in an access operation one cycle after the last data-out cycle of a read operation, and two cycles after the last data-in cycle of a write operation. Neither the PDE nor the HOLD command is allowed on the cycle immediately following the last data-in cycle of a write operation. Legend: n = CLK cycle number, L = Logic low, H = Logic high, X = Don’t care, either logic low or logic high, V = Valid, M = Masked input data, N/A = Not applicable, T = Bank T, B = Bank B, actv = Activated, deac = Deactivated, write = Activated and accepting data inputs on cycle n, read = Activated and delivering data outputs on cycle (n + 2) . Table 4 — Serial 4-Word Burst Sequences INTERNAL COLUMN ADDRESS A1-A0, BA1-BA0 DECIMAL BINARY START 2ND 3RD 4TH START 2ND 3RD 4TH 0 1 2 3 00 01 10 11 1 2 3 0 01 10 11 00 2 3 0 1 10 11 00 01 3 0 1 2 11 00 01 10 Table 5 – Serial 8-Word Burst Sequences INTERNAL COLUMN ADDRESS A2-A0, BA2-BA0 DECIMAL BINARY START 2ND 3RD 4TH 5TH 6TH 7TH 8TH START 2ND 3RD 4TH 5TH 6TH 7TH 8TH 0 1 2 3 4 5 6 7 000 001 010 011 100 101 110 111 1 2 3 4 5 6 7 0 001 010 011 100 101 110 111 000 2 3 4 5 6 7 0 1 010 011 100 101 110 111 000 001 3 4 5 6 7 0 1 2 011 100 101 110 111 000 001 010 4 5 6 7 0 1 2 3 100 101 110 111 000 001 010 011 5 6 7 0 1 2 3 4 101 110 111 000 001 010 011 100 6 7 0 1 2 3 4 5 110 111 000 001 010 011 100 101 7 0 1 2 3 4 5 6 111 000 001 010 011 100 101 110 Aeroflex Circuit Technology 7 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 Absolute Maximum Ratings1 Symbol Rating Range Units VCC Supply Voltage -0.5 to 4.6 V VCCQ Supply Voltage range for output drivers -0.5 to 4.6 V Voltage range on any pin with respect to VSS -0.5 to 4.6 V -55 to +125 °C -65 to +150 °C Short-Circuit Output Current 50 mA Power Dissipation 4.2 W VRANGE TBIAS Case Temperature under Bias TSTG Storage Temperature ISHORT PW 2 1. Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. 2. The temperature rise of θjc is negligible due to the low duty cycle during testing. Recommended Operating Conditions Symbol Parameter Minimum Typical Maximum Units VCC Supply Voltage 3 3.3 3.6 V VCCQ Supply Voltage range for output drivers 3 3.3 3.6 V VSS Supply Voltage 0 V VSSQ Supply Voltage range for output drivers 0 V VIH Input High Voltage VIL Input Low Voltage 1 TC Operating Temperature (Case) 2 2 VCC + 0.3 V -0.3 0.8 V -55 +110 °C 1. VIL Minimum = 1.5Vac (Pulsewidth < 5ns) 2. The temperature rise of θjc is negligible due to the low duty cycle during testing. DC Characteristics (VCC = 3.3V ±10%; Tc =-55°C to +110°C, See Notes 1 & 5) Parameter Symbol Conditions Min Output Low Voltage VOL IOL = 2mA Output High Voltage VOH IOH = -2mA 2.4 Max Units 0.4 V V Input current (Leakage) II 0V < VI < VCC + 0.3V, All other pins = 0V to VCC -10 +10 µA Output current (Leakage) IO 0V < VO < VCC + 0.3V, Output disabled -10 +10 µA Precharge standby current in non-power-down mode ICC2N CKE > VIH MIN, tCK = 20ns (See note 2) 180 mA ICC2NS CKE > VIH MIN, CLK < VIL MAX, tCK = ∞ (See note 3) 40 mA 1. All specifications apply to the device after power- up initialization. All control and address inputs must be stable and valid. 2. Control, DQ, and address inputs change state only once every 40 ns. 3. Control, DQ, and address inputs do not change (stable). 4. All ICC parameters measured with VCC, not VCCQ. 5. The temperature rise of θjc is negligible due to the low duty cycle during testing. Aeroflex Circuit Technology 8 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 Capacitance † (f = 1MHz, Tc = 25°C) Symbol Ci(S) Ci(AC) Ci(E) CO † Parameter Min Max Units Input Capacitance, CLK Input 50 pF Input Capacitance, Address and Control Inputs: A0-A11, CS, DQMx, RAS, CAS, WE 40 pF Input Capacitance, CKE Input 50 pF Output Capacitance 20 pF Parameters Guaranteed but not tested †‡ AC Timing (Vcc = 3.3V ±0.3V, Tc = -55°C to +110°C, See Note 4) Parameter Symbol Cycle time, CLK tCK2 Pulse duration, CLK high Test Conditions Min Max Units 20 ns tCH 6 ns Pulse duration, CLK low tCL 6 ns Access time, CLK high to data out (see Note 1) tAC2 Hold time, CLK high to data out tOH 1 ns Setup time, address, control, and data input tIS 5 ns Hold time, address, control, and data input tIH 3 ns Delay time, ACTV command to DEAC or DCAB command tRAS 72 Delay time, ACTV or REFR to ACTV, MRS or REFR command tRC 108 ns Delay time ACTV command to READ, READ-P, WRT, or WRT-P command (see Note 2) tRCD 30 ns Delay time, DEAC or DCAB command to ACTV, MRS or REFR command tRP 36 ns Delay time, ACTV command in one bank to ACTV command in the other bank tRRD 24 ns Delay time, MRS command to ACTV, MRS or REFR command tRSA 30 ns Final data out of READ-P operation to ACTV, MRS or REFR command tAPR Final data in of WRT-P operation to ACTV, MRS or REFR command tAPW CAS latency = 2 13 CAS latency = 2 100000 ns ns Min Aeroflex Circuit Technology t RP - (CL -1) * tCK ns (see Note 3) 9 60 ns SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 †‡ (cont.) AC Timing (Vcc = 3.3V ±0.3V, Tc = -55°C to +110°C, See Note 4) Parameter Symbol Delay time, final data in of WRT operation to DEAC or DCAB command tWR Refresh interval tREF Delay time, CS low or high to input enabled or inhibited nCDD Delay time, CKE high or low to CLK enabled or disabled Test Conditions Min Max 20 Units ns 50 ms 0 0 cycle nCLE 1 1 cycle Delay time, final data in of WRT operation to READ, READ-P, WRT, or WRT-P nCWL 1 Delay time, ENBL or MASK command to enabled or masked data in nDID 0 0 cycle Delay time, ENBL or MASK command to enabled or masked data out nDOD 2 2 cycle Delay time, DEAC or DCAB, command to DQ in high-impedance state nHZP2 2 cycle Delay time, WRT command to first data in nWCD 0 cycle Delay time, STOP command to READ or WRT command nBSD 2 cycle CAS latency = 2 0 cycle † See Figure 2 - LVTTL Load Circuit for load circuits. ‡ All references are made to the rising transition of CLK, unless otherwise noted. NOTES: 1. tAC is referenced from the rising transition of CLK that is previous to the data-out cycle. For example, the first data out tAC is referenced from the rising transition of CLK within the following cycle: CAS latency minus one cycle after the READ command. An access time is measured at output reference level 1.5 V. 2. For read or write operations with automatic deactivate, tRCD must be set to satisfy minimum tRAS . 3. CL = CAS Latency. 4. The temperature rise of θjc is negligible due to the low duty cycle during testing. Aeroflex Circuit Technology 10 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 tCK tCH CLK tT tCL tT ti S ti H DQ, A0-A11, CS, RAS, CAS, WE, DQMx, CKE tT ti H tiS, tCESP DQ, A0-A11, CS, RAS, CAS, WE, DQMx, CKE tT Figure 3 – Input-Attribute Parameters CAS latency CLK ACTV Command tHZ tAC READ Command tLZ tOH DQ Figure 4 – Output Parameters DESL nCDD Command Disable ACTV tRAS DEAC, DCAB ACTV, REFR tRC ACTV (same bank), MRS, REFR ACTV tRCD READ, READ-P, WRT, WRT-P DEAC, DCAB tRP ACTV tRRD ACTV (Different Bank) MRS tRSA ACTV, MRS, REFR ACTV, MRS, REFR Figure 5 – Command-to-Command Parameters Aeroflex Circuit Technology 11 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 Package Information – "F20" – CQFP 200 Leads 1.464 (37.186) SQ 1.436 (36.474) SQ 150 101 100 .028 (.711) .022 (.559) 151 .010R MIN .015 (.381) .009 (.229) .010R MIN .130 (3.302) MAX 1.230 (31.242) 1.220 (30.988) 49 Spaces at .025 (49 Spaces at .635) 0°±5° .100 (2.540) .080 (2.032) .012 (.304) .009 (.229) .035 (.889) .025 (.635) Detail "A" 51 200 Pin 1 Chamfer 1 50 .045 (1.143) REF .1.290 (32.766) SQ REF .008 (.202) .005 (.127) Detail "A" 1.664 (42.266) 1.596 (40.538) .115 (2.921) MAX .066 (1.676) .054 (1.372) Note: 1. All Dimensions in inches (Millimeters) MAX or Typical where noted. MIN Pin Nomenclature A0-A10 BA0-BA10 Address Inputs A0-A10, BA0-BA10 Row Addresses A0-A7, BA0-BA7 Column Addresses A10, BA10 Automatic-Precharge Select DQML1,2 DQMU1,2 Data/Input Mask Enables A11,BA11 Bank Select RAS1,RAS2 Row-Address Strobe CAS1,CAS2 Column-Address Strobe VCC Power Supply CKE1,CKE2 Clock Enable VCCQ Power Supply for Output Drivers CLK1,CLK2 System Clock VSS Ground CS1,CS2 Chip Select VSSQ Ground for Output Drivers DQ0-DQ95 SDRAM Data Input/Output WE1,WE2 Write Enable Aeroflex Circuit Technology 12 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 ACT-D1M96S CQFP Pinouts – "F20" PIN # FUNCTION PIN # FUNCTION PIN # FUNCTION PIN # FUNCTION PIN # FUNCTION 1 DQ2 41 DQ91 81 DQ67 121 VSSQ 161 DQ30 2 DQ3 42 VSSQ 82 DQ66 122 BA1 162 VSSQ 3 VSSQ 43 DQ92 83 VSS 123 BA2 163 DQ29 4 DQ4 44 DQ93 84 DQ65 124 VCCQ 164 DQ28 5 DQ5 45 VCCQ 85 DQ64 125 BA3 165 VCC 6 VCCQ 46 DQ94 86 VCC 126 A4 166 DQ27 7 DQ6 47 DQ95 87 DQ63 127 VCCQ 167 DQ26 8 DQ7 48 VSSQ 88 DQ62 128 A5 168 VSS 9 VSSQ 49 DQ87 89 VSSQ 129 A6 169 DQ25 10 DQML1 50 DQ86 90 DQ61 130 VSSQ 170 DQ24 11 WE1 51 DQ85 91 DQ60 131 A7 171 VSSQ 12 VSSQ 52 DQ84 92 VSSQ 132 A8 172 CLK1 13 CAS1 53 VSSQ 93 DQ59 133 VSS 173 CKE1 14 RAS1 54 DQ83 94 DQ58 134 A9 174 VCCQ 15 VCC 55 DQ82 95 VCCQ 135 DQMU1 175 DQ23 16 CS1 56 VCCQ 96 DQ57 136 VCC 176 DQ22 17 A11 57 DQ81 97 DQ56 137 DQ40 177 VCCQ 18 VSS 58 DQ80 98 VSSQ 138 DQ41 178 DQ21 19 A10 59 VSSQ 99 DQ48 139 VSSQ 179 DQ20 20 A0 60 DQ79 100 DQ49 140 DQ42 180 VSSQ 21 VSSQ 61 DQ78 101 DQ50 141 DQ43 181 DQ19 22 A1 62 VSSQ 102 DQ51 142 VSSQ 182 DQ18 23 A2 63 DQ77 103 VSSQ 143 DQ44 183 VSS 24 VCCQ 64 DQ76 104 DQ52 144 DQ45 184 DQ17 25 A3 65 VCC 105 DQ53 145 VCCQ 185 DQ16 26 BA4 66 DQ75 106 VCCQ 146 DQ46 186 VCC 27 VCCQ 67 DQ74 107 DQ54 147 DQ47 187 DQ15 28 BA5 68 VSS 108 DQ55 148 VSSQ 188 DQ14 29 BA6 69 DQ73 109 VSSQ 149 DQ39 189 VSSQ 30 VSSQ 70 DQ72 110 DQML2 150 DQ38 190 DQ13 31 BA7 71 VSSQ 111 WE2 151 DQ37 191 DQ12 32 BA8 72 CLK2 112 VSSQ 152 DQ36 192 VSSQ 33 VSS 73 CKE2 113 CAS2 153 VSSQ 193 DQ11 34 BA9 74 VCCQ 114 RAS2 154 DQ35 194 DQ10 35 DQMU2 75 DQ71 115 VCC 155 DQ34 195 VCCQ 36 VCC 76 DQ70 116 CS2 156 VCCQ 196 DQ9 37 DQ88 77 VCCQ 117 BA11 157 DQ33 197 DQ8 38 DQ89 78 DQ69 118 VSS 158 DQ32 198 VSSQ 39 VSSQ 79 DQ68 119 BA10 159 VSSQ 199 DQ0 40 DQ90 80 VSSQ 120 BA0 160 DQ31 200 DQ1 Aeroflex Circuit Technology 13 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700 CIRCUIT TECHNOLOGY Sample Ordering Information Part Number Screening Speed Package ACT-D1M96S-020F20C Commercial Temperature 20 ns 200 Lead CQFP ACT-D1M96S-020F20T Extended Temperature 20 ns 200 Lead CQFP ACT-D1M96S-020F20M Extended Temperature Screening 20 ns 200 Lead CQFP Part Number Breakdown ACT– D 1M 96 S – 020 F20 M Aeroflex Circuit Technology Screening Memory Type C = Commercial Temp, 0°C to +70°C I = Industrial Temp, -40°C to +85°C T = Extended Temp, -55°C to +110°C M = Extended Temp, -55°C to +110°C, Screened * Q = MIL-PRF-38534 Compliant/SMD if applicable Package Type & Size D = DRAM Memory Depth, Locations Memory Width, Bits Surface Mount Package F20 = 1.45" SQ 200 Lead CQFP Options S = Syncronous Memory Speed, ns * Screened to the individual test methods of MIL-STD-883 Specifications subject to change without notice. Aeroflex Circuit Technology 35 South Service Road Plainview New York 11803 www.aeroflex.com/act1.htm Aeroflex Circuit Technology Telephone: (516) 694-6700 FAX: (516) 694-6715 Toll Free Inquiries: (800) 843-1553 E-Mail: [email protected] 14 SCD3369-1 REV C 5/31/00 Plainview NY (516) 694-6700