ALPHA AV132-315

HIP3™ Variable Attenuator
for DCS and PCS Base Stations
AV132-315
Features
■ 23 dB Attenuation Range
■ 1.5 dB Insertion Loss, 1.5 SWR
■ 0–12 V Control Voltage
■ 43 dBm IP3
■ Small Footprint LGA Package
■ Designed for DCS/PCS Base Station
Applications
Description
The AV132-315 is a voltage controlled variable attenuator
from Alpha’s series of HIP3™ components. It is
specifically designed and specified for use as a wide
dynamic range low distortion attenuator for DCS and PCS
base station applications centered at 1837.5 MHz and
1960 MHz. The AV132-315 employs a monolithic
quadrature hybrid and a pair of silicon PIN diodes to
achieve the specified low distortion performance. It
operates from 0–12 V with 1.6 mA typical control current
at maximum attenuation. The AV132-315 is packaged in
a small outline LGA (Land Grid Array) surface mount
package with the internal elements affixed to an organic
BT substrate.
Electrical Specifications at 25°C
Parameter
Condition
DCS Frequency Range (BW)
PCS Frequency Range (BW)
FO ± 30.0 MHz
Control Voltage (CV) Range
Insertion Loss in BW
CV = 0 V
Attenuation Range
At FO, CV = 12 V
Max.
Unit
1805
Min.
Typ.
1870
MHz
1930
1990
MHz
0
12
V
1.5
dB
23
VSWR in BW
dB
1.5
IP3
1900/1905 MHz, CV = 0 V
IM3
8 dBm
43
dBm
-70
Alpha Industries, Inc. [978] 241-7000 • Fax [978] 241-7906 • Email [email protected] • www.alphaind.com
Specifications subject to change without notice. 1/02A
dBc
1
HIP3™ Variable Attenuator for DCS and PCS Base Stations
AV132-315
Typical Performance Data
0
0
-0.05
0V
Control Voltage (V)
Loss (dB)
-5
4V
-10
8V
-15
-20
-0.20
-0.25
-0.30
-0.35
-0.40
-0.50
1.830
1.855
1.880
0
2
4
6
8
10
12
Frequency (GHz)
Flatness (dB)
Insertion Loss vs. Frequency and
Control Voltage — DCS Band
Insertion Loss Flatness vs.
Control Voltage — DCS Band
12
-10
0V
-20
8V
12 V
-25
12 V
10
Phase (Degrees)
4V
-15
Return Loss (dB)
-0.15
-0.45
12 V
-25
1.805
-0.10
-30
8
6
4
8V
2
4V
0V
-35
1.805
1.830
1.855
0
1.805
1.880
1.830
Frequency (GHz)
1.855
1.880
Frequency (GHz)
Input/Output Return Loss vs. Frequency
and Control Voltage — DCS Band
Phase vs. Frequency and
Control Voltage — DCS Band
2.0
50
48
Total Current (mA)
46
IP3 (dBm)
44
42
40
38
36
34
1.5
1.0
0.5
32
0
30
0
2
2
4
6
8
10
12
0
3
6
9
12
Control Voltage (V)
Control Voltage (V)
IP3 vs. Control Voltage
RF1 = 1.900 GHz, RF2 = 1.905 GHz @ 8 dBm
Total Current vs. Control Voltage
Alpha Industries, Inc. [978] 241-7000 • Fax [978] 241-7906 • Email [email protected] • www.alphaind.com
Specifications subject to change without notice. 1/02A
HIP3™ Variable Attenuator for DCS and PCS Base Stations
AV132-315
0
0
-0.05
0V
-0.10
4V
Flatness (dB)
Loss (dB)
-5
-10
8V
-15
-20
-0.15
-0.20
-0.25
-0.30
-0.35
-0.40
12 V
-25
1.93
-0.45
-0.50
1.94
1.95
1.96
1.97
1.98
1.99
0
4
6
8
10
12
Frequency (GHz)
Control Voltage (V)
Insertion Loss vs. Frequency and
Control Voltage — PCS Band
Insertion Loss Flatness vs.
Control Voltage — PCS Band
12
-10
10
0V
4V
Phase (Degrees)
-15
Return Loss (dB)
2
-20
8V
12 V
-25
-30
12 V
8
6
4
8V
2
-35
1.93
1.94
1.95
1.96
1.97
1.98
1.99
4V
0V
0
1.93 1.94
Frequency (GHz)
1.95
1.96
1.97
1.98
1.99
Frequency (GHz)
Input/Output Return Loss vs. Frequency
and Control Voltage — PCS Band
Phase vs. Frequency and
Control Voltage — PCS Band
50
48
Intermod (dBm)
46
44
42
40
38
36
34
32
30
0
2
4
6
8
10
12
Control Voltage (V)
3rd Order Intermod vs. Control Voltage
RF1 = 1.900 GHz, RF2 = 1.905 GHz @ 8 dBm
Alpha Industries, Inc. [978] 241-7000 • Fax [978] 241-7906 • Email [email protected] • www.alphaind.com
Specifications subject to change without notice. 1/02A
3
HIP3™ Variable Attenuator for DCS and PCS Base Stations
GND
Vcontrol
Connection Diagram
Vcontrol
Pin Out (Bottom View)
C1
C2
C3
AV132
RF
IN/OUT
A1
A2
A3
GND
IN/OUT
B3 GND
IN/OUT
GND B1
AV132-315
Vcontrol
10 pF
10 pF
CONTROL
VOLTAGE
RF
IN/OUT
Vcontrol
10 pF
A2
GND
A3
IN/OUT
B1
GND
B3
GND
C1
Vcontrol
C2
GND
C3
Vcontrol
-315
A1
0.126
B
(3.20 mm) 1
Absolute Maximum Ratings
Characteristic
Value
RF Input Power
0.5 W CW, 4 W @ 12.5%
Duty Cycle
Control Voltage
15 V
0.037 (1.00 mm)
Control Current
50 mA Each Diode
0.047 (1.20 mm)
Operating Temperature
-40 to +85°C
Storage Temperature
-40 to +85°C
Maximum Reverse Diode Voltage
Electrostatic Discharge
0.091 (2.32 mm)
0.193 (4.90 mm)
0.000
0.079 (2.00 mm)
-10 V
C1
C2
0.166 (4.22 mm)
0.193 (4.90 mm)
IN/OUT
0.112 (2.85 mm)
0.135 (3.42 mm)
A1
10 pF
0.058 (1.48 mm)
0.081 (2.05 mm)
Terminal Name
0.000
0.027 (0.68 mm)
Terminal No.
C3
0.079 (2 mm)
ENCAP
0.014 (0.36 mm)
SUBSTRATE
0.024 (0.60 mm)
B3
B1
A1
A2
A3
0.031
(0.775 mm) 0.054 (1.370 mm)
+125 V
Note: Operating this device above any of these parameters may cause
irreversible damage.
4
Alpha Industries, Inc. [978] 241-7000 • Fax [978] 241-7906 • Email [email protected] • www.alphaind.com
Specifications subject to change without notice. 1/02A