AUK A358

A358
Semiconductor
Low Power Dual OP AMP
Description
The A358 consists of two independent high gain Internally frequency compensated
operational amplifiers designed to operate from a single power supply over a wide
range of voltage.
Features
•
•
•
•
•
•
Input common mode voltage range includes ground
Internally frequency compensated for unity gain
Large DC voltage gain : 100dB
Wide bandwidth for unity gain : 1 MHz
Very low power consumption
Wide supply voltage range : Single : 3V ~ 20V, Dual : ±1.5 ~ ±10V
Applications
• Transducer amplifier
• DC gain blocks
• Conventional operational amplifiers
Ordering Information
Type NO.
A358
Marking
Package Code
A358
SOP-8
Outline Dimensions
unit : mm
Block Diagram
KSI-8009-001
1
A358
Absolute maximum ratings
Characteristic
Symbol
Ratings
Unit
Supply voltage
VCC
20 or ±10
V
Differential input voltage
VIND
20
V
Input voltage
VIN
±10
V
Power Dissipation
PD
300
mW
Operating temperature
Topr
-45 ~ +85
°C
Storage temperature
Tstg
-55 ~ 150
°C
Electrical Characteristics
(Unless otherwise specified. VCC = 5V, VEE = GND, Ta=25°C)
Characteristic
Symbol
Input offset voltage
VIOS
Input offset current
Input bias current
Rg ≤ 10 KΩ
Min. Typ. Max.
Unit
-
2
7
mV
IIOS
-
5
50
nA
IIB
-
45
250
nA
V
common mode voltage range
VICR
Supply current
ICC
Output voltage swing
Test Condition
VCC = 15V, VEE = GND
0
-
VCC
–1.5
VCC = 15V, RL = ∞
-
0.7
1.4
VCC = 5V, RL = ∞
-
0.5
1.2
mA
VOH
VIN+ = 1V, VIN- = 0V, RL=2 KΩ
2.5
3.5
4.2
V
VOL
VIN+ = 0V, VIN- = 1V, RL=2 KΩ
-
2
20
mV
Common mode rejection ratio
CMRR
VCC = 15V
65
90
-
dB
Power supply rejection ratio
PSRR
VCC = 15V
65
100
-
dB
Output source current
IO+
VIN+ = 1V, VIN- = 0V, VOUT = 0V
20
40
-
mA
Output sink current
IO-
VIN+ = 0V, VIN- = 1V, VOUT = 5V
10
20
-
mA
Slew Rate
SR
-
-
0.5
-
V/uS
KSI-8009-001
2
A358
Electrical Characteristic Curves
Fig. 1 VIOS-Ta
Fig. 2 IO-Ta
Fig. 3 CMRR-f
Fig. 4 VOR-f
KSI-8009-001
3
SA2332
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KSI-8009-001
4