AUK A4558

A4558
Semiconductor
Low Noise Dual OP AMP
Description
The A4558 is a monolithic Integrated Circuit designed for dual operational amplifier.
Features
•
•
•
•
•
•
Power consumption as small as about 50mW (typ.)
Built-in output short-circuit protecting circuit.
Internal phase consumption type.
No latch-up
Wide same phase mode and differential voltage ranges
High gain. low noise
Applications
•
•
•
•
Active filters
Audio amplifiers
VCOs
Other electronic circuits
Ordering Information
Type NO.
A4558
Marking
A4558
Package Code
SOP-8
Outline Dimensions
unit : mm
Block Diagram
KSI-8010-003
1
A4558
Absolute maximum ratings
Characteristic
Symbol
Ratings
Unit
Supply voltage
VCC
20 or ±10
V
Differential input voltage
VIND
20
V
Input voltage
VIN
±10
V
Power Dissipation
PD
300
mW
Operating temperature
Topr
-45 ~ +85
°C
Storage temperature
Tstg
-55 ~ +150
°C
Electrical Characteristics
(Unless otherwise specified. VCC = +5V, VEE=-5V and
Parameter
Input Offset Voltage
Symbol
VIOS
Input Offset Current
IIOS
Input Bias Current
Input Common Mode
Voltage Range
Maximum Output Voltage
Common Mode Rejection
Ratio
Power Supply Rejection
Ratio
Ta = 25 °C)
Min.
0
Typ.
0.5
Max.
6
Unit
mV
-
-
5
200
nA
IIB
-
-
60
500
nA
VICR
-
±5
±7
-
V
RL=10 ㏀
±2.9
±3.4
-
V
RL=2 ㏀
±2.7
±3.2
-
V
VOM
Test Conditions
Rg≤ 10 ㏀
CMRR
Rg≤ 10 ㏀
70
90
-
dB
PSRR
Rg≤ 10 ㏀
-
30
150
uV/V
-
3
6
mA
RL≥ 2 ㏀
-
2
-
V/us
-
3
-
MHz
86
100
-
dB
mA
mA
Supply Current
ICC
Slew Rate
SR
-
Unity Gain Cross Frequency
fT
Open Loop
Large Signal Voltage Gain
GV
VCC=8V, VEE=-8V, RL=2K
Output Sink Current
Output Source Current
ISINK
-
15
25
-
ISOURCE
-
15
25
-
KSI-8010-003
2
A4558
Electrical Characteristic Curves
Fig. 1 GV - f
Fig. 3 IIB - Ta
Fig. 2 VOPP -f
Fig. 4 VOM-Vcc, VEE
KSI-8010-003
3
A4558
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KSI-8010-003