AUK S393

S393
Semiconductor
Dual Voltage Comparator
Description
The S393 consists of two independent voltage comparators designed to operate from
a single power supply over a wide voltage range.
Features
•
•
•
•
•
•
•
•
Single Supply Operation: 2V to 36V.
Dual Supply Operation: ±1V to ±18V.
Allow Comparison of Voltages Near Ground Potential.
Low Current Drain 800uA Typ.
Compatible with all Forms of Logic.
Low Input Bias Current: 25nA Typ.
Low Input Offset Current: ±5nA Typ.
Low Offset Voltage: ±1mV Typ.
Applications
• Transducer amplifier
• DC gain blocks
• Conventional operational amplifiers
Ordering Information
Type NO.
S393
Marking
Package Code
S393
SOP-8
Outline Dimensions
unit : mm
Block Diagram
B
A
A
KSI-8003-001
1
S393
Absolute maximum ratings
Characteristic
Symbol
Ratings
Unit
Supply voltage
VCC
36 or ±18
V
Differential input voltage
VIND
36
V
Input voltage
VIN
-0.3 ~ +36
V
Power Dissipation
PD
300
mW
Operating temperature
Topr
-40 ~ +85
°C
Storage temperature
Tstg
-65 ~ 150
°C
Electrical Characteristics
(Unless otherwise specified. VCC = 5V and –40 °C ≤ Ta ≤ +85 °C)
Characteristic
Symbol
Test Condition
VO = 1.4V
Rs = 0Ω
Min. Typ. Max.
Unit
-
±1
±5
mV
Input Offset Voltage
VIOS
Input Offset Current
IIOS
-
-
±5
±50
nA
Input Bias Current
IIB
-
-
25
250
nA
Input Common Mode
Voltage Range
VICR
-
0
-
VCC
–1.5
V
Supply Current
ICC
VCC = 30V, RL = ∞, All Channel
-
-
2.5
mA
Large Signal Voltage
Gain
AV
VCC = 15V
RL = 15 KΩ
50
200
-
V/mV
Output Voltage (‘L’ Level)
VSAT
VIN+= 0V, VIN-= 1V
ISINK≤ 4mA
-
150
400
mV
Response Time
tRES
RL = 5.1 KΩ, CL = 15pF
-
1.3
-
uS
Output Sink Current
ISINK
VO ≤ 1.5V
VIN+ = 0V, VIN- = 1V
6
16
-
mA
Output Leakage Current
ILeak
VO = 5V
VIN+ = 1V, VIN- = 0V
-
0.1
-
nA
KSI-8003-001
2
S393
Electrical Characteristic Curves
Fig. 1 VCC-ICC
Fig. 2 VCC-IIB
Fig. 3 VOL-ISINK
Fig. 4 PD-Ta
Fig. 5 VIN,VOUT-trsp
Fig. 6 VIN,VOUT-trsp
Ω
Ω
KSI-8003-001
3
S393
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KSI-8003-001
4