CLARE M-959

M-959
Dial Pulse Counter and Hook Status Monitor
Features
• Time-guarded dial pulse counting
• 10 or 20 PPS dialing speeds pin selectable
• Tri-state data outputs
• Valid data output strobe
• Data strobe control for use in interrupt-driven
environments
• Independent hook status monitoring
• Low-power CMOS construction
Pin Diagram
Description
The M-959 is a low-power dial pulse counter and
hook status monitor. Contained in a 14-pin package,
the M-959 requires no external components except a
single 3.579 MHz television color burst crystal.
The M-959 is typically connected to a loop current
sensing circuit, which is connected in series with the
voice pair (Tip and Ring) of a telephone line. The M959 receives pulses from the loop current sense circuit and translates them into logic level outputs
indicating hook status and decoded dialed digits.
Logic inputs to the M-959 select dialed digit speeds
and control Data and Strobe outputs supporting bus
interrupt driven implementations.
Ordering Information
Part #
M-959
Description
14-pin plastic DIP
Block Diagram
DS-M959-R3
www.clare.com
1
M-959
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of
the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability.
Absolute Maximum Ratings
DC Supply Voltage
Any Input Voltage Relative to VDD
Any Input Voltage Relative to VSS
Operating Temperature Range
Storage Temperature Range
6.0 V
+0.3 V
-0.3 V
-40˚C to +85˚C
-55˚C to + 125˚C
* Exceeding these ratings may permanently damage the M-959.
Specifications
VDD - VSS = 2.5 through 6.0 V unless otherwise noted.
Parameter
Signal Timing Break Recognition
Spurious Break
Rejection
Make Recognition
Interdigit Time (IDT)
Off-hook Delay
On-hook Delay
LC Hysteresis
EOD (End of Digit)
Recognition
STROBE Active
Data Change Before
Logic Input
Input Voltages
Requirements
Input Current
Pull Up/Down Resistance
Logic Output Output Voltages
Characteristics
Output Currents
Power
Requirement
Tri-State Leakage
Supply Current
Conditions
10 PPS
20 PPS
–
Min
45
30
0
Typ
–
–
–
Max
85
40
10
Units
ms
ms
ms
10 PPS
20 PPS
10 PPS
20 PPS
–
–
–
10 PPS
20 PPS
10 PPS
20 PPS
–
Logic 0
Logic 1
30
15
285
142.5
95
285
1
95
47.5
190
95
1.0
0.0
3.5
–
–
0.0
4.5
-2.1
-0.44
0.44
–
–
–
–
300
150
100
300
1.5
100
50
200
100
1.5
2.25
2.75
–
–
65
24
315
157.5
105
315
2
105
52.5
210
105
2.0
1.5
5.0
± 30
2.0
0.5
5.0
–
–
–
± 1.0
2.0
ms
ms
ms
ms
ms
ms
ms
ms
ms
ms
ms
ms
V
V
µA
mA
V
V
mA
mA
mA
µA
mA
–
Logic 0
Logic 1
Vout = 2.5V
Vout = 4.6V
Vout = 0.4V
–
–
-4.2
-0.88
0.88
–
–
Notes
1, 2
1,3
1, 4
1, 3
1
1
1
Notes:
1. VDD - VSS = 5.0V
2. Maximimum is 30% of VDD - VSS
3. Minimum is 70% of VDD - VSS
4. No load.
5. Typical column for reference only.
2
www.clare.com
Rev. 3
M-959
Pin Functions
Pin
LC
OH
10/20
D3-D0
OE
XIN
XOUT
Clear
Strobe
Function
Loop Current Input. Signal from phone line to be monitored for dial pulse signaling and hook status. Active low,
internally pulled high.
Off-hook Output. Hook status of phone line. Active (off-hook) high.
Pulse Speed Input. Low for 10 pulse per second, high for 20 pulse per second. Internally pulled low.
Data Outputs. Binary decoded rotary dialed digit. Active during valid digit time (strobe high), low at any other time.
Digit Dialed D3
D2
D1
D0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
0
1
0
1
0
Output Enable Input. Active high, a log low tri-states D3 through D0 outputs. Internally pulled high.
Crystal Oscillator Input
Crystal Oscillator Output.
Strobe Control Input. Momentary high during digit valid time resets STROBE latch output low until next valid
digit is received. Internally pulled low.
Digit Valid Output. Indicates valid digit data present on D3 through D0. Active high.
Timing Diagram
Rev. 3
www.clare.com
3
M-959
Mechanical Dimensions
Tolerances
Inches
Min
A
A1
b
b2
C
D
E
E1
e
ec
L
Max
.210
.015
.014
.022
.045
.070
.008
.014
.735
.775
.300
.325
.240
.280
100 BSC
0˚
15˚
.115
.150
Metric (mm)
Min
Max
5.33
.38
.36
.56
1.14
1.78
.20
.36
18.67
19.70
7.62
8.26
6.10
7.1
2.54 BSC
0˚
15˚
2.92
3.81
Dimensions
mm
(inches)
4
www.clare.com
Rev. 3
Worldwide Sales Offices
CLARE LOCATIONS
EUROPE
ASIA/PACIFIC
Clare Headquarters
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
European Headquarters
CP Clare nv
Bampslaan 17
B-3500 Hasselt (Belgium)
Tel: 32-11-300868
Fax: 32-11-300890
Clare Switch Division
4315 N. Earth City Expressway
Earth City, MO 63045
Tel: 1-314-770-1832
Fax: 1-314-770-1812
France
Clare France Sales
Lead Rep
99 route de Versailles
91160 Champlan
France
Tel: 33 1 69 79 93 50
Fax: 33 1 69 79 93 59
Asian Headquarters
Clare
Room N1016, Chia-Hsin, Bldg II,
10F, No. 96, Sec. 2
Chung Shan North Road
Taipei, Taiwan R.O.C.
Tel: 886-2-2523-6368
Fax: 886-2-2523-6369
Clare Micronix Division
145 Columbia
Aliso Viejo, CA 92656-1490
Tel: 1-949-831-4622
Fax: 1-949-831-4628
SALES OFFICES
AMERICAS
Americas Headquarters
Clare
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
Eastern Region
Clare
603 Apache Court
Mahwah, NJ 07430
Tel: 1-201-236-0101
Fax: 1-201-236-8685
Toll Free: 1-800-27-CLARE
Central Region
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Western Region
Clare
1852 West 11th Street, #348
Tracy, CA 95376
Tel: 1-209-832-4367
Fax: 1-209-832-4732
Toll Free: 1-800-27-CLARE
Canada
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Germany
Clare Germany Sales
ActiveComp Electronic GmbH
Mitterstrasse 12
85077 Manching
Germany
Tel: 49 8459 3214 10
Fax: 49 8459 3214 29
Italy
C.L.A.R.E.s.a.s.
Via C. Colombo 10/A
I-20066 Melzo (Milano)
Tel: 39-02-95737160
Fax: 39-02-95738829
http://www.clare.com
Sweden
Clare Sales
Comptronic AB
Box 167
S-16329 Spånga
Tel: 46-862-10370
Fax: 46-862-10371
United Kingdom
Clare UK Sales
Marco Polo House
Cook Way
Bindon Road
Taunton
UK-Somerset TA2 6BG
Tel: 44-1-823 352541
Fax: 44-1-823 352797
Clare, Inc. makes no representations or warranties with respect to
the accuracy or completeness of the contents of this publication
and reserves the right to make changes to specifications and
product descriptions at any time without notice. Neither circuit
patent licenses nor indemnity are expressed or implied. Except as
set forth in Clare’s Standard Terms and Conditions of Sale, Clare,
Inc. assumes no liability whatsoever, and disclaims any express or
implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed,
intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction
of Clare’s product may result in direct physical harm, injury, or
death to a person or severe property or environmental damage.
Clare, Inc. reserves the right to discontinue or make changes to its
products at any time without notice.
Specification: DS-M959-R3
©Copyright 2001, Clare, Inc.
All rights reserved. Printed in USA.
7/20/01