ERICSSON PGE60802

PGE 608 02
Erbium-Doped Fiber Amplifier
for Digital Applications
Key Features
• Operating wavelength window: 15301560 nm
• Saturation output power: +13 dBm
• Noise figure, typ. <7.0 dB
• Serial (RS-232) interface with parallel
alarms
Applications
• Single channel digital applications
(SDH/SONET)
Description
The PGE 608 02 is an integrated, output power-locked amplifier. It has
optically isolated input and output ports as well as input and output power
monitoring. The serial and parallel interface is provided through a DB-25
electrical connector. The modules are based on industry standard platforms
and are optimized for single channel SDH/SONET applications.
1
PGE 608 02
Optical
input
signal
Optical
output
signal
Gain
Input
power
monitor
Output
power
monitor
Control
Circuitry
Alarm
and
monitor signals
Set
Commands
Figure 1. Block diagram
48.5
129
118
4 x M3
124
150
Figure 2. Mechanical outline and pin description
2
11
37.8
15.5
[mm]
Pin
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
Description
NC
NC
NC
NC
Output Power Monitor
Input Power Monitor
GND
Alarm #1 Optical Output Fault
Alarm #2 Pump Drive Current Fault
Alarm #3 Pump Temperature
-5.0 V
+5.0 V
GND
NC
NC
NC
NC
Serial output (TTL)
Alarm #4 Optical Input Fault
Eye-safe Power Control Input
Amplifier Disable Input
Serial input (TTL)
-5.0 V
+5.0 V
GND.
PGE 608 02
Optical Characteristics
Electrical and optical characteristics at recommended operating conditions, unless otherwise noted.
Parameter
Operating Wavelength
Input Power
Output Power
Input/Output Return Loss
Noise Figure
Small Signal Gain
Conditions
At 1550 nm, Pin = -6 dBm, at RT
Over Tc and λL. EDFA turned on.
Pin = -6dBm
< -6 dBm Input, at RT
Symbol
Min
λL
Pin
Pout
IRL/ORL
1530
12.5
NF
Typ
-6
13.0
≥ 28
Max
Unit
1560
nm
dBm
dBm
dB
13.5
< 7.0
25
dB
dB
Electrical Characteristics
Parameter
Conditions
Operating Current
Positive Voltage
Negative Voltage
Pins # 12 and 24
Pins #11 and 23
On both Positive and Negative Voltage
Max. Duration 75 ms
Max. Duration 75 ms
Over operating temperature and time
Operating Voltage
Ripple and Noise
Transients – Positive V
Transients – Negative
Power Dissipation
Symbol
Min
4.75
–5.50
Typ
5.00
–5.00
4.5
-6.0
Max
Unit
2
1
5.50
–4.75
2% PP
6.0
-4.5
10
A
A
V
V
V
V
W
Operating Conditions
Parameter
Symbol
Min
Max
Unit
Operating Case Temperature
TCase
0
Typ
65
°C
Min
Max
Unit
-40
75
ºC
Absolute Maximum Ratings
Parameter
Storage Temperature
Symbol
CAUTION: Stresses outside those listed in ”Absolute Maximum Ratings” may cause permanent damage to the device.
3
PGE 608 02
Handling Precautions
This device may be damaged as a result of electrostatic
discharge (ESD). Take proper precautions during both handling and testing. This typically includes grounded wrist
wraps, workbenches and floor mats in ESD controlled areas.
Semiconductor devices may be damaged by current surges,
use appropriate transient protection.
Quality Assurance
Ericsson Microelectronics commitment to quality has been
proven through a decade of semiconductor device production and has been confirmed to ISO 9001. Opto product
qualification is made according to the intention of applicable Telcordia standards.
Connector Options
SC/SPC
SC/APC
(Other connectors available on request)
DANGER
INVISIBLE LASER RADIATION
AVOID DIRECT EXPOSURE TO BEAM
WAVELENGTH 1300 nm - 1600 nm
CLASS 3B LASER
Information given in this data sheet is believed to be accurate and
reliable. However no responsibility is assumed for the consequences of
its use nor for any infringement of patents or other rights of third
parties which may result from its use. No license is granted by
implication or otherwise under any patent or patent rights of Ericsson
Microelectronics. These products are sold only according to Ericsson
Microelectronics' general conditions of sale, unless otherwise
confirmed in writing.
Product specifications subject to change without
notice.
Ericsson Microelectronics AB
SE-164 81 Kista, Sweden
Telephone: +46 8 757 50 00
www.ericsson.com/microelectronics
For local sales contacts, please refer to our website
or call: Int + 46 8 757 47 00, Fax: +46 8 757 47 76
4