ERICSSON PGE60830

PGE 608 30
EDFA Gain Block
for DWDM Applications
Key Features
• Operating wavelength window:
1540-1560 nm
• Operating temperature range:
-5 °C to 70 °C (with cooled pump)
• Small size (120x80x15 mm)
Applications
• Ideal for Metro DWDM networks up to
8 channels
Description
A cost effective, small sized EDFA gain block for Metro applications. Booster,
line-, and pre-amplifier configurations are available.
1
PGE 608 30
Optical
input
signal
Optical
gain
Optical
output
signal
28 pin
electrical
interface
Figure 1. Block diagram
47.5
Base View
39
39
R26 (x4)
Output
22
28
7
15
21
4 x M3 (5.6 deep)
28
14
14
25
8
1
2.0
2.0
40
80
0.50 x 0.50 square
(2 x 7)
Pin type:
Molex Milli-Grid
(87089-1416)
or equivalent.
2.00 mm Pitch
2 x 7 Pins
Input
10
23.75
50
Note:
1. Dimensions in mm
2. Tolerance ± 0.15 mm
100
Side View
15
3.5
Top View
120
80
Output
Input
Figure 2. Mechanical Outline Drawing and Pin Connection
2
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15-17
18
19-24
25
26-28
Function
Thermistor, Pump
Laser Anode, Pump
TEC Neg., Pump
GND
Pump Monitor Anode, Pump
NC
Input Monitor Cathode
Thermistor, Pump
Laser Cathode, Pump
TEC Pos., Pump
GND
Pump Monitor Cathode, Pump
NC
Input Monitor Anode
NC
GND
NC
GND
NC
PGE 608 30
Optical Characteristics
Electrical and optical characteristics over recommended operating conditions, unless otherwise noted.
Parameter
Operating Wavelength
Measurement Wavelength
Input Power
Output Power
Noise Figure
Gain Flatness
Conditions
@ PIL=-6 dBm @ λL
@ PIL=-6 dBm @ λL (Note1)
Symbol
λL
λM
PIL
Pout
NF
GFLAT
Min
Typ
1540
-9
12
1550
-6
13
6
-1
Max
Unit
1560
nm
nm
0
7
1
dBm
dB
dB
Note 1. GFLAT = (GMAX-GMIN)/2, where GMAX is the maximum gain for λL and GMIN is the minimum gain for λL.
The gain is measured as dynamic gain under constant saturation.
Electrical Characteristics
Parameter
Conditions
Operating Current
Operating Voltage
Power Dissipation
Thermistor Resistance
TEC Current
TEC Voltage
Symbol
IDRIVE
VF
PE
RTH
ITEC
VTEC
Min
Typ
9.5
10
Typ
Max
Unit
720
2.5
7
10.5
1.2
3.3
mA
V
W
kΩ
A
V
Recommended Operating Conditions
Parameter
Symbol
Min
Operating Case Temperature
TCase
-5
Max
70
Parameter
Symbol
Min
Max
Storage Temperature
Drive Current
Tstg
ILD_MAX
-40
75
800
Unit
°C
Absolute Maximum Ratings
Unit
°C
mA
CAUTION: Stresses outside those listed in ”Absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress only rating and operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied.
3
PGE 608 30
Handling Precautions
This device may be damaged as a result of electrostatic
discharge (ESD). Take proper precautions during both handling and testing. This typically includes grounded wrist
wraps, workbenches and floor mats in ESD controlled areas.
Semiconductor devices may be damaged by current surges,
use appropriate transient protection.
Quality Assurance
Ericsson Microelectronics commitment to quality has been
proven through a decade of semiconductor device production and has been confirmed to ISO 9001. Opto product
qualification is made according to the intention of applicable
Telcordia standards.
Connector Options
SC/SPC
(Other connectors available on request)
DANGER
INVISIBLE LASER RADIATION
AVOID DIRECT EXPOSURE TO BEAM
WAVELENGTH 1300 nm - 1600 nm
CLASS 3B LASER
Information given in this data sheet is believed to be accurate and
reliable. However no responsibility is assumed for the consequences of
its use nor for any infringement of patents or other rights of third
parties which may result from its use. No license is granted by
implication or otherwise under any patent or patent rights of Ericsson
Microelectronics. These products are sold only according to Ericsson
Microelectronics' general conditions of sale, unless otherwise
confirmed in writing.
Product specifications subject to change without
notice.
Ericsson Microelectronics AB
SE-164 81 Kista, Sweden
Telephone: +46 8 757 50 00
www.ericsson.com/microelectronics
For local sales contacts, please refer to our website
or call: Int + 46 8 757 47 00, Fax: +46 8 757 47 76
4
1522-PGE 608 30 Rev. C
© Ericsson Microelectronics AB, August 2000