www.ti.com TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS SLVS695A – JUNE 2007 – REVISED MARCH 2008 FEATURES 1 • • • • • • • • Eight Constant-Current Output Channels Output Current Adjusted Through External Resistor Constant Output Current Range: 5 mA to 120 mA Constant Output Current Invariant to Load Voltage Change Open Load, Short Load and Overtemperature Detection 256-Step Programmable Global Current Gain Excellent Output Current Accuracy: – Between Channels: < ±3% (Max) – Between ICs: < ±6% (Max) Fast Response of Output Current • • • • 30-MHz Clock Frequency Schmitt-Trigger Input 3.3-V or 5-V Supply Voltage Thermal Shutdown for Overtemperature Protection APPLICATIONS • • • • • • General LED Lighting Applications LED Display Systems LED Signage Automotive LED Lighting White Goods Gaming Machines/Entertainment DESCRIPTION/ORDERING INFORMATION The TLC5916/TLC5917 is designed for LED displays and LED lighting applications with constant-current control and open-load, shorted-load, and overtemperature detection. The TLC5916/TLC5917 contains an 8-bit shift register and data latches, which convert serial input data into parallel output format. At the output stage, eight regulated current ports are designed to provide uniform and constant current for driving LEDs within a wide range of VF variations. Used in system design for LED display applications, e.g., LED panels, it provides great flexibility and device performance. Users can adjust the output current from 5 mA to 120 mA through an external resistor, Rext, which gives flexibility in controlling the light intensity of LEDs. The devices are designed for up to 17 V at the output port. The high clock frequency, 30 MHz, also satisfies the system requirements of high-volume data transmission. The TLC5916/TLC5917 provides a Special Mode in which two functions are included, Error Detection and Current Gain Control. There are two operation modes and three phases: Normal Mode phase, Mode Switching transition phase, and Special Mode phase. The signal on the multiple function pin OE(ED2) is monitored to determine the mode. When an one-clock-wide pulse appears on OE(ED2), the device enters the Mode Switching phase. At this time, the voltage level on LE(ED1) determines the mode to which the TLC5916/TLC5917 switches. In the Normal Mode phase, the serial data can be transferred into TLC5916/TLC5917 via the pin SDI, shifted in the shift register, and transferred out via the pin SDO. LE(ED1) can latch the serial data in the shift register to the output latch. OE(ED2) enables the output drivers to sink current. In the Special Mode phase, the low-voltage-level signal OE(ED2) can enable output channels and detect the status of the output current, to determine if the driving current level is sufficient. The detected Error Status is loaded into the 8-bit shift register and shifted out via the pin SDO, synchronous to the CLK signal. The system controller can read the error status and determine whether or not the LEDs are properly lit. In the Special Mode phase, the TLC5916/TLC5917 allows users to adjust the output current level by setting a runtime-programmable Configuration Code. The code is sent into the TLC5916/TLC5917 via SDI. The positive pulse of LE(ED1) latches the code in the shift register into a built-in 8-bit configuration latch, instead of the output latch. The code affects the voltage at the terminal R-EXT and controls the output-current regulator. The output current can be finely adjusted by a gain ranging from 1/12 to 127/128 in 256 steps. Therefore, the current skew between ICs can be compensated within less than 1%. This feature is suitable for white balancing in LED color display panels. 1 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2007–2008, Texas Instruments Incorporated TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ORDERING INFORMATION (1) SHORT TO VLED DETECTION TA PACKAGE (2) PDIP – N No SOIC – D TSSOP – PW –40°C to 125°C PDIP – N Yes SOIC – D TSSOP – PW (1) (2) ORDERABLE PART NUMBER Tube of 25 TLC5916IN Tube of 40 TLC5916ID Reel of 2500 TLC5916IDR Tube of 90 TLC5916IPW Reel of 2000 TLC5916IPWR Tube of 25 TLC5917IN Tube of 40 TLC5917ID Reel of 2500 TLC5917IDR Tube of 90 TLC5917IPW Reel of 2000 TLC5917IPWR TOP-SIDE MARKING TLC5916IN TLC5916I Y5916 TLC5917IN TLC5917I Y5917 For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI web site at www.ti.com. Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. BLOCK DIAGRAM OUT0 OUT1 OUT6 OUT7 I/O Regulator R-EXT 8 OE(ED2) Output Driver and Error Detection Control Logic 8 8 VDD 8-Bit Output Latch LE(ED1) Configuration Latches 8 CLK 8 SDI 8-Bit Shift Register SDO 8 2 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 D, N, OR PW PACKAGE (TOP VIEW) GND SDI CLK LE(ED1) OUT0 OUT1 OUT2 OUT3 1 16 2 15 3 14 4 5 13 12 6 11 7 10 8 9 VDD R-EXT SDO OE(ED2) OUT7 OUT6 OUT5 OUT4 Terminal Descriptions TERMINAL NAME DESCRIPTION CLK Clock input for data shift on rising edge GND Ground for control logic and current sink LE(ED1) Data strobe input Serial data is transferred to the respective latch when LE(ED1) is high. The data is latched when LE(ED1) goes low. Also, a control signal input for an Error Detection Mode and Current Adjust Mode (see Timing Diagram). LE(ED1) has an internal pulldown. OE(ED2) Output enable. When OE(ED2) is active (low), the output drivers are enabled; when OE(ED2) is high, all output drivers are turned OFF (blanked). Also, a control signal input for an Error Detection Mode and Current Adjust Mode (see Figure 1). OE(ED2) has an internal pullup. OUT0–OUT7 Constant-current outputs R-EXT Input used to connect an external resistor for setting up all output currents SDI Serial-data input to the Shift register SDO Serial-data output to the following SDI of next driver IC or to the microcontroller VDD Supply voltage Diagnostic Features OVERTEMPERATURE DETECTION OPEN-LOAD DETECTION SHORT TO GND DETECTION TLC5916 X X X TLC5917 X X X DEVICE (1) (1) SHORT TO VLED DETECTION X The device has one single error register for all these conditions (one error bit per channel). Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 3 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Timing Diagram 0 1 2 3 4 5 6 7 CLK OE(ED2) 1 LE(ED1) 0 SDI off OUT0 on off OUT1 on off OUT2 on off OUT3 on off OUT7 on Don't care SDO Figure 1. Normal Mode Truth Table in Normal Mode CLK LE(ED1) OE(ED2) SDI OUT0...OUT7 SDO ↑ H L Dn Dn...Dn – 7 Dn – 7 ↑ L L Dn + 1 No change Dn – 6 ↑ H L Dn + 2 Dn + 2...Dn – 5 Dn – 5 ↓ X L Dn + 3 Dn + 2...Dn – 5 Dn – 5 ↓ X H Dn + 3 Off Dn – 5 The signal sequence shown in Figure 2 makes the TLC5916/TLC5917 enter Current Adjust and Error Detection Mode. 1 2 3 4 5 OE(ED2) 1 0 1 1 1 LE(ED1) 0 0 0 1 0 CLK Figure 2. Switching to Special Mode 4 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 In the Current Adjust Mode, sending the positive pulse of LE(ED1), the content of the shift register (a current adjust code) is written to the 8-bit configuration latch (see Figure 3). 0 1 2 6 3 7 CLK OE(ED2) 1 LE(ED1) 0 8-bit Configuration Code SDI Figure 3. Writing Configuration Code When the TLC5916/TLC5917 is in the Error Detection Mode, the signal sequence shown in Figure 4 enables a system controller to read error status codes through SDO. 1 2 3 CLK >2 µs OE(ED2) 1 LE(ED1) 0 SDO Error Status Code Figure 4. Reading Error Status Code The signal sequence shown in Figure 5 makes TLC5916/TLC5917 resume the Normal Mode. Switching to Normal Mode resets all internal Error Status registers. OE(ED2) always enables the output port, whether the TLC5916/TLC5917 enters Current Adjust Mode or not. 1 2 3 4 5 OE(ED2) 1 0 1 1 1 LE(ED1) 0 0 0 0 0 CLK Figure 5. Switching to Normal Mode Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 5 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted) MIN MAX 0 7 V Input voltage range –0.4 VDD + 0.4 V VO Output voltage range –0.5 20 V fclk Clock frequency 25 MHz IOUT Output current 120 mA IGND GND terminal current 960 mA TA Operating free-air temperature range –40 125 °C TJ Operating junction temperature range –40 150 °C Tstg Storage temperature range –55 150 °C ESD Electrostatic discharge capability, V(HBMESD) 1.5 kV VDD Supply voltage range VI 100 pF, 1.5 kΩ UNIT Power Dissipation and Thermal Impedance MIN D package PD Power dissipation Mounted on JEDEC 4-layer board (JESD 51-7), No airflow, TA = 25°C, TJ = 125°C Mounted on JEDEC 1-layer board (JESD 51-3), No airflow θJA Thermal impedance, junction to free air N package D package 103 N package 148 PW package 176 PW package 6 Submit Documentation Feedback 1 0.9 N package UNIT 1.5 PW package D package Mounted on JEDEC 4-layer board (JESD 51-7), No airflow MAX 66 W °C/W 97 112 Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Recommended Operating Conditions CONDITIONS VDD Supply voltage VO Supply voltage to output pins MIN MAX 3 5.5 V 17 V OUT0–OUT7 VO ≥ 0.6 V 5 UNIT IO Output current DC test circuit IOH High-level output current source SDO shorted to GND –1 mA IOL Low-level output current sink SDO shorted to VCC 1 mA VIH High-level input voltage CLK, OE(ED2), LE(ED1), and SDI 0.7 × VDD VDD V VIL Low-level input voltage CLK, OE(ED2), LE(ED1), and SDI 0 0.3 × VDD V VO ≥ 1 V 120 mA Recommended Timing VDD = 3 V to 5.5 V (unless otherwise noted) CONDITIONS MIN MAX UNIT tw(L) LE(ED1) pulse duration Normal Mode 20 ns tw(CLK) CLK pulse duration Normal Mode 20 ns tw(OE) OE(ED2) pulse duration tsu(D) Setup time for SDI Normal Mode th(D) Hold time for SDI tsu(L) Setup time for LE(ED1) th(L) Normal Mode, IOUT < 60 mA 500 Normal Mode, IOUT > 60 mA 700 ns 3 ns Normal Mode 2 ns Normal Mode 15 ns Hold time for LE(ED1) Normal Mode 15 ns tw(CLK) CLK pulse duration Error Detection Mode 20 ns tw(ED2) OE(ED2) pulse duration Error Detection Mode 2000 ns tsu(ED1) Setup time for LE(ED1) Error Detection Mode 4 ns th(ED1) Hold time for LE(ED1) Error Detection Mode 10 ns tsu(ED2) Setup time for OE(ED2) Error Detection Mode 6 ns th(ED2) Hold time for OE(ED2) Error Detection Mode 10 fCLK Clock frequency Cascade operation Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 ns 30 Submit Documentation Feedback MHz 7 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Electrical Characteristics VDD = 3 V, TJ = –40°C to 125°C (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP (1) UNIT Input voltage VO Supply voltage to the output pins IO Output current IOH High-level output current, source IOL Low-level output current, sink VIH High-level input voltage 0.7 × VDD VDD V VIL Low-level input voltage GND 0.3 × VDD V Ileak Output leakage current VOH = 17 V VOH High-level output voltage SDO, IOL = –1 mA VOL Low-level output voltage SDO, IOH = 1 mA Output current 1 VOUT = 0.6 V, Rext = 720 Ω, CG = 0.992 26 Output current error, die-die IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω, TJ = 25°C ±3 ±6 % Output current skew, channel-to-channel IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω, TJ = 25°C ±1.5 ±3 % Output current 2 VO = 0.8 V, Rext = 360 Ω, CG = 0.992 52 Output current error, die-die IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω, TJ = 25°C ±2 ±6 % Output current skew, channel-to-channel IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω, TJ = 25°C ±1.5 ±3 % VO = 1 V to 3 V, IO = 26 mA ±0.1 IO(1) IO(2) IOUT vs VOUT Output current vs output voltage regulation 3 MAX VDD VO ≥ 0.6 V –1 1 mA TJ = 25°C 0.5 TJ = 125°C 2 VDD – 0.4 500 LE(ED1) 500 Restart temperature hysteresis IOUT,Th1 Threshold current for open error detection IOUT,Th2 175 V mA mA %/V ±1 150 µA V 0.4 VDD = 3.0 V to 5.5 V, IO = 26 mA/120 mA mA mA OE(ED2) Thys V 120 Pulldown resistance Overtemperature shutdown (2) V 17 5 VO ≥ 1 V Pullup resistance Tsd 5.5 kΩ kΩ 200 °C 15 °C IOUT,target = 26 mA 0.5 × Itarget % Threshold current for open error detection IOUT,target = 52 mA 0.5 × Itarget % IOUT,Th3 Threshold current for open error detection IOUT,target = 104 mA 0.5 × Itarget % IOUT,Th Threshold current for open error detection IOUT,target = 5 mA to 120 mA 0.5 × Itarget % VOUT,TTh Trigger threshold voltage for short-error detection (TLC5917 only) IOUT,target = 5 mA to 120 mA 2.5 VOUT,RTh Return threshold voltage for short-error detection (TLC5917 only) IOUT,target = 5 mA to 120 mA 2.2 IDD (1) (2) 8 Supply current 2.7 3.1 V V Rext = Open 5 10 Rext = 720 Ω 8 14 Rext = 360 Ω 11 18 Rext = 180 Ω 16 22 mA Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the application and configuration and may vary over time. Typical values are not ensured on production material. Specified by design. Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Electrical Characteristics VDD = 5.5 V, TJ = –40°C to 125°C (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP (1) UNIT Input voltage VO Supply voltage to the output pins IO Output current IOH High-level output current, source IOL Low-level output current, sink VIH High-level input voltage 0.7 × VDD VDD V VIL Low-level input voltage GND 0.3 × VDD V Ileak Output leakage current VOH = 17 V VOH High-level output voltage SDO, IOL = –1 mA VOL Low-level output voltage SDO, IOH = 1 mA Output current 1 VOUT = 0.6 V, Rext = 720 Ω, CG = 0.992 26 Output current error, die-die IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω, TJ = 25°C ±3 ±6 % Output current skew, channel-to-channel IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω, TJ = 25°C ±1.5 ±3 % Output current 2 VO = 0.8 V, Rext = 360 Ω, CG = 0.992 52 Output current error, die-die IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω, TJ = 25°C ±2 ±6 % Output current skew, channel-to-channel IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω, TJ = 25°C ±1.5 ±3 % VO = 1 V to 3 V , IO = 26 mA ±0.1 IO(1) IO(2) IOUT vs VOUT Output current vs output voltage regulation 3 MAX VDD VO ≥ 0.6 V –1 1 mA TJ = 25°C 0.5 TJ = 125°C 2 VDD – 0.4 500 LE(ED1), 500 Restart temperature hysteresis IOUT,Th1 Threshold current for open error detection IOUT,Th2 175 V mA mA %/V ±1 150 µA V 0.4 VDD = 3.0 V to 5.5 V, IO = 26 mA/120 mA mA mA OE(ED2), Thys V 120 Pulldown resistance Overtemperature shutdown (2) V 17 5 VO ≥ 1 V Pullup resistance Tsd 5.5 kΩ kΩ 200 °C 15 °C IOUT,target = 26 mA 0.5 × Itarget % Threshold current for open error detection IOUT,target = 52 mA 0.5 × Itarget % IOUT,Th3 Threshold current for open error detection IOUT,target = 104 mA 0.5 × Itarget % IOUT,Th Threshold current for open error detection IOUT,target = 5 mA to 120 mA 0.5 × Itarget % VOUT,TTh Trigger threshold voltage for short-error detection (TLC5917 only) IOUT,target = 5 mA to 120 mA 2.5 VOUT,RTh Return threshold voltage for short-error detection (TLC5917 only) IOUT,target = 5 mA to 120 mA 2.2 IDD (1) (2) Supply current 2.7 3.1 V V Rext = Open 6 10 Rext = 720 Ω 11 14 Rext = 360 Ω 13 18 Rext = 180 Ω 19 24 mA Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the application and configuration and may vary over time. Typical values are not ensured on production material. Specified by design. Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 9 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Switching Characteristics VDD = 3 V, TJ = –40°C to 125°C (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP (1) MAX UNIT tPLH1 Low-to-high propagation delay time, CLK to OUTn 40 65 95 ns tPLH2 Low-to-high propagation delay time, LE(ED1) to OUTn 40 65 95 ns tPLH3 Low-to-high propagation delay time, OE(ED2) to OUTn 40 65 95 ns tPLH4 Low-to-high propagation delay time, CLK to SDO 12 20 30 ns tPHL1 High-to-low propagation delay time, CLK to OUTn 300 365 ns tPHL2 High-to-low propagation delay time, LE(ED1) to OUTn 300 365 ns tPHL3 High-to-low propagation delay time, OE(ED2) to OUTn 300 365 ns tPHL4 High-to-low propagation delay time, CLK to SDO 12 20 30 ns tw(CLK) Pulse duration, CLK 20 ns tw(L) Pulse duration, LE(ED1) 20 ns tw(OE) Pulse duration, OE(ED2) 500 ns tw(ED2) Pulse duration, OE(ED2) in Error Detection Mode 2 µs th(ED1,ED2) Hold time, LE(ED1) and OE(ED2) 10 ns th(D) Hold time, SDI 2 ns tsu(D,ED1) Setup time, SDI, LE(ED1) 3 ns tsu(ED2) Setup time, OE(ED2) 8.5 ns th(L) Hold time, LE(ED1), Normal Mode 15 ns tsu(L) Setup time, LE(ED1), Normal Mode 15 ns (2) tr Rise time, CLK tf Fall time, CLK (2) tor Rise time, outputs (off) tor Rise time, outputs (off), TJ = 25°C tof Rise time, outputs (on) tof Rise time, outputs (on), TJ = 25°C fCLK Clock frequency (1) (2) 10 VIH = VDD, VIL = GND, Rext = 360 Ω, VL = 4 V, RL = 44 Ω, CL = 10 pF, CG = 0.992 40 100 Cascade operation 500 ns 500 ns 85 105 ns 83 100 ns 280 370 ns 170 225 ns 30 MHz Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the application and configuration and may vary over time. Typical values are not ensured on production material. If the devices are connected in cascade and tr or tf is large, it may be critical to achieve the timing required for data transfer between two cascaded devices. Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Switching Characteristics VDD = 5.5 V, TJ = –40°C to 125°C (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP (1) MAX UNIT tPLH1 Low-to-high propagation delay time, CLK to OUTn 40 65 95 ns tPLH2 Low-to-high propagation delay time, LE(ED1) to OUTn 40 65 95 ns tPLH3 Low-to-high propagation delay time, OE(ED2) to OUTn 40 65 95 ns tPLH4 Low-to-high propagation delay time, CLK to SDO 8 20 30 ns tPHL1 High-to-low propagation delay time, CLK to OUTn 300 365 ns tPHL2 High-to-low propagation delay time, LE(ED1) to OUTn 300 365 ns tPHL3 High-to-low propagation delay time, OE(ED2) to OUTn 300 365 ns tPHL4 High-to-low propagation delay time, CLK to SDO 20 30 ns tw(CLK) Pulse duration, CLK 20 ns tw(L) Pulse duration, LE(ED1) 20 ns tw(OE) Pulse duration, OE(ED2) 500 ns tw(ED2) Pulse duration, OE(ED2) in Error Detection Mode 2 µs th(D,ED1,ED2) Hold time, SDI, LE(ED1), and OE(ED2) 10 ns th(D) Hold time, SDI 2 ns tsu(D,ED1) Setup time, SDI, LE(ED1) 3 ns tsu(ED2) Setup time, OE(ED2) 8.5 ns th(L) Hold time, LE(ED1), Normal Mode 15 ns tsu(L) Setup time, LE(ED1), Normal Mode 15 ns Rise time, CLK tf Fall time, CLK (2) tor Rise time, outputs (off) tor Rise time, outputs (off), TJ = 25°C tof Rise time, outputs (on) tof Rise time, outputs (on), TJ = 25°C fCLK Clock frequency (2) VIH = VDD, VIL = GND, Rext = 360 Ω, VL = 4 V, RL = 44 Ω, CL = 10 pF, CG = 0.992 (2) tr (1) 8 40 100 Cascade operation 500 ns 500 ns 85 105 ns 83 100 ns 280 370 ns 170 225 ns 30 MHz Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the application and configuration and may vary over time. Typical values are not ensured on production material. If the devices are connected in cascade and tr or tf is large, it may be critical to achieve the timing required for data transfer between two cascaded devices. Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 11 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 PARAMETER MEASUREMENT INFORMATION IDD VDD OE(ED2) IIH, IIL IOUT OUT0 CLK LE(ED1) OUT7 SDI VIH, VIL R-EXT GND SDO Iref Figure 6. Test Circuit for Electrical Characteristics IDD IOUT VDD VIH, VIL OE(ED2) CLK LE(ED1) Function Generator OUT0 OUT7 RL CL SDI Logic Input Waveform VIH = 5 V VIL = 0V R-EXT GND SDO Iref CL VL Figure 7. Test Circuit for Switching Characteristics 12 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 PARAMETER MEASUREMENT INFORMATION (continued) tw(CLK) 50% CLK 50% tsu(D) SDI 50% 50% th(D) 50% 50% tPLH4, tPHL4 50% SDO tw(L) 50% LE(ED1) tsu(L) th(L) OE(ED2) LOW tPLH2, tPHL2 Output off OUTn 50% Output on tPLH1, tPHL1 tw(OE) OE(ED2) HIGH 50% 50% tPLH3 tPHL3 Output off 80% 80% OUTn 50% 50% 20% 20% tof tor Figure 8. Normal Mode Timing Waveforms Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 13 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 PARAMETER MEASUREMENT INFORMATION (continued) tw(CLK) 50% CLK tsu(ED2) OE(ED2) th(ED2) 50% tsu(ED1) LE(ED1) th(ED1) 50% 2 CLK Figure 9. Switching to Special Mode Timing Waveforms CLK OE(ED2) 50% 50% tw(ED2) Figure 10. Reading Error Status Code Timing Waveforms 14 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 TYPICAL CHARACTERISTICS LE = 5 V (active) OE = GND (active) CLK OUTn Figure 11. Response Time, CLK to OUTn Turn on only one channel Channel 1 OE OUT1 Figure 12. Response Time, OE to OUT1 Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 15 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 TYPICAL CHARACTERISTICS (continued) Turn on only one channel Channel 8 OE OUT7 Figure 13. Response Time, OE to OUT7 16 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 APPLICATION INFORMATION Operating Principles Constant Current In LED display applications, TLC5916/TLC5917 provides nearly no current variations from channel to channel and from IC to IC. While IOUT ≤ 100 mA, the maximum current skew between channels is less than ±3% and between ICs is less than ±6%. Adjusting Output Current TLC5916/TLC5917 scales up the reference current, Iref, set by the external resistor Rext to sink a current, Iout, at each output port. Users can follow the below formulas to calculate the target output current IOUT,target in the saturation region: VR-EXT = 1.26 V × VG Iref = VR-EXT/Rext, if another end of the external resistor Rext is connected to ground IOUT,target = Iref × 15 × 3CM – 1 Where Rext is the resistance of the external resistor connected to the R-EXT terminal, and VR-EXT is the voltage of R-EXT, which is controlled by the programmable voltage gain (VG), which is defined by the Configuration Code. The Current Multiplier (CM) determines that the ratio IOUT,target/Iref is 15 or 5. After power on, the default value of VG is 127/128 = 0.992, and the default value of CM is 1, so that the ratio IOUT,target/Iref = 15. Based on the default VG and CM: VR-EXT = 1.26 V × 127/128 = 1.25 V IOUT,target = (1.25 V/Rext) × 15 Therefore, the default current is approximately 52 mA at 360 Ω and 26 mA at 720 Ω. The default relationship after power on between IOUT,target and Rext is shown in Figure 14. 140 IOUT – mA 120 100 80 40 0 0 500 1000 1500 2000 2500 3000 3500 4000 Rext – Ω Figure 14. Default Relationship Curve Between IOUT,target and Rext After Power Up Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 17 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Operation Phases Operation Mode Switching To switch between its two modes, TLC5916/TLC5917 monitors the signal OE(ED2). When an one-clock-wide pulse of OE(ED2) appears, TLC5916/TLC5917 enters the two-clock-period transition phase, the Mode Switching phase. After power on, the default operation mode is the Normal Mode (see Figure 15). Switching to Special Mode 1 2 3 Switching to Normal Mode 4 5 1 CLK 2 3 4 5 CLK OE(ED2) 1 0 1 1 1 OE(ED2) 1 0 1 1 1 LE(ED1) 0 0 0 1 0 LE(ED1) 0 0 0 0 0 Actual Mode Phase (Normal or Special) Mode Switching Special Mode Actual Mode Phase (Normal or Special) Mode Switching Normal Mode Figure 15. Mode Switching As shown in Figure 15, once a one-clock-wide short pulse (101) of OE(ED2) appears, TLC5916/TLC5917 enters the Mode Switching phase. At the fourth rising edge of CLK, if LE(ED1) is sampled as voltage high, TLC5916/TLC5917 switches to Special Mode; otherwise, it switches to Normal Mode. The signal LE(ED1) between the third and the fifth rising edges of CLK cannot latch any data. Its level is used only to determine into which mode to switch. However, the short pulse of OE(ED2) can still enable the output ports. During mode switching, the serial data can still be transferred through SDI and shifted out from SDO. NOTES: 1. The signal sequence for the mode switching may be used frequently to ensure that TLC5916/TLC5917 is in the proper mode. 2. The 1 and 0 on the LE(ED1) signal are sampled at the rising edge of CLK. The X means its level does not affect the result of mode switching mechanism. 3. After power on, the default operation mode is Normal Mode. Normal Mode Phase Serial data is transferred into TLC5916/TLC5917 via SDI, shifted in the Shift Register, and output via SDO. LE(ED1) can latch the serial data in the Shift Register to the Output Latch. OE(ED2) enables the output drivers to sink current. These functions differ only as described in Operation Mode Switching, in which case, a short pulse triggers TLC5916/TLC5917 to switch the operation mode. However, as long as LE(ED1) is high in the Mode Switching phase, TLC5916/TLC5917 remains in the Normal Mode, as if no mode switching occurred. Special Mode Phase In the Special Mode, as long as OE(ED2) is not low, the serial data is shifted to the Shift Register via SDI and shifted out via SDO, as in the Normal Mode. However, there are two differences between the Special Mode and the Normal Mode, as shown in the following sections. 18 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Reading Error Status Code in Special Mode When OE(ED2) is pulled low while in Special Mode, error detection and load error status codes are loaded into the Shift Register, in addition to enabling output ports to sink current. Figure 16 shows the timing sequence for error detection. The 0 and 1 signal levels are sampled at the rising edge of each CLK. At least three zeros must be sampled at the voltage low signal OE(ED2). Immediately after the second zero is sampled, the data input source of the Shift Register changes to the 8-bit parallel Error Status Code register, instead of from the serial data on SDI. Normally, the error status codes are generated at least 2 µs after the falling edge of OE(ED2). The occurrence of the third or later zero saves the detected error status codes into the Shift Register. Therefore, when OE(ED2) is low, the serial data cannot be shifted into TLC5916/TLC5917 via SDI. When OE(ED2) is pulled high, the data input source of the Shift Register is changed back to SDI. At the same time, the output ports are disabled and the error detection is completed. Then, the error status codes saved in the Shift Register can be shifted out via SDO bit by bit along with CLK, as well as the new serial data can be shifted into TLC5916/TLC5917 via SDI. While in Special Mode, the TLC5916/TLC5917 cannot simultaneously transfer serial data and detect LED load error status. 1 2 3 CLK >2 µs OE(ED2) 1 0 0 0 0 0 1 1 1 1 LE(ED1) 0 0 0 0 0 0 0 0 0 0 Error Status Code SDO Bit 7 Data source of shift register Error Detection SDI Bit 6 Bit 5 Bit 4 SDI Figure 16. Reading Error Status Code Writing Configuration Code in Special Mode When in Special Mode, the active high signal LE(ED1) latches the serial data in the Shift Register to the Configuration Latch, instead of the Output Latch. The latched serial data is used as the Configuration Code. The code is stored until power off or the Configuration Latch is rewritten. As shown in Figure 17, the timing for writing the Configuration Code is the same as the timing in the Normal Mode to latching output channel data. Both the Configuration Code and Error Status Code are transferred in the common 8-bit Shift Register. Users must pay attention to the sequence of error detection and current adjustment to avoid the Configuration Code being overwritten by Error Status Code. 0 1 2 3 4 5 6 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 CLK OE(ED2) 1 LE(ED1) 0 Bit 7 Bit 6 SDI 8-Bit Configuration Code Figure 17. Writing Configuration Code Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 19 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Open-Circuit Detection Principle The LED Open-Circuit Detection compares the effective current level Iout with the open load detection threshold current IOUT,Th. If IOUT is below the IOUT,Th threshold, the TLC5916/TLC5917 detects an open-load condition. This error status can be read as an error status code in the Special Mode. For open-circuit error detection, a channel must be on. Table 1. Open-Circuit Detection STATE OF OUTPUT PORT CONDITION OF OUTPUT CURRENT ERROR STATUS CODE MEANING IOUT = 0 mA 0 Detection not possible IOUT < IOUT,Th (1) 0 Open circuit Channel n error status bit 1 Normal Off On (1) IOUT ≥ IOUT,Th (1) IOUT,Th = 0.5 × IOUT,target (typical) Short-Circuit Detection Principle (TLC5917 Only) The LED short-circuit detection compares the effective voltage level (VOUT) with the shorted-load detection threshold voltages VOUT,TTh and VOUT,RTh. If VOUT is above the VOUT,TTh threshold, the TLC5917 detects an shorted-load condition. If VOUT is below the VOUT,RTh threshold, no error is detected/error bit is reset. This error status can be read as an error status code in the Special Mode. For short-circuit error detection, a channel must be on. Table 2. Shorted-Load Detection STATE OF OUTPUT PORT CONDITION OF OUTPUT VOLTAGE ERROR STATUS CODE MEANING Off On IOUT = 0 mA 0 Detection not possible VOUT ≥ VOUT,TTh 0 Short circuit VOUT < VOUT,RTh 1 Normal Minimum Return Threshold Minimum Trigger Threshold 2.2 V 2.5 V Maximum Trigger Threshold No Fault Short Fault 3.1 V VOUT,RTh VOUT,TTh VOUT Figure 18. Short-Circuit Detection Principle 20 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 Overtemperature Detection and Shutdown TLC5916/TLC5917 is equipped with a global overtemperature sensor and eight individual, channel-specific, overtemperature sensors. • When the global sensor reaches the trip temperature, all output channels are shut down, and the error status is stored in the internal Error Status register of every channel. After shutdown, the channels automatically restart after cooling down, if the control signal (output latch) remains on. The stored error status is not reset after cooling down and can be read out as the error status code in the Special Mode. • When one of the channel-specific sensors reaches trip temperature, only the affected output channel is shut down, and the error status is stored only in the internal Error Status register of the affected channel. After shutdown, the channel automatically restarts after cooling down, if the control signal (output latch) remains on. The stored error status is not reset after cooling down and can be read out as error status code in the Special Mode. For channel-specific overtemperature error detection, a channel must be on. The error status code is reset when TLC5916/TLC5917 returns to Normal Mode. Table 3. Overtemperature Detection (1) STATE OF OUTPUT PORT (1) CONDITION ERROR STATUS CODE MEANING Off IOUT = 0 mA 0 On On → all channels Off Tj < Tj,trip global 1 Normal Tj > Tj,trip global All error status bits = 0 Global overtemperature On On → Off Tj < Tj,trip channel n 1 Normal Tj > Tj,trip channel n Channel n error status bit = 0 Channel n overtemperature The global shutdown threshold temperature is approximately 170°C. Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 21 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 8-Bit Configuration Code and Current Gain Bit definition of the Configuration Code in the Configuration Latch is shown in Table 4. Table 4. Bit Definition of 8-Bit Configuration Code Meaning Default Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 CM HC CC0 CC1 CC2 CC3 CC4 CC5 1 1 1 1 1 1 1 1 Bit 7 is first sent into TLC5916/TLC5917 via SDI. Bits 1 to 7 {HC, CC[0:5]} determine the voltage gain (VG) that affects the voltage at R-EXT and indirectly affects the reference current, Iref, flowing through the external resistor at R-EXT. Bit 0 is the Current Multiplier (CM) that determines the ratio IOUT,target/Iref. Each combination of VG and CM gives a specific Current Gain (CG). • VG: the relationship between {HC,CC[0:5]} and the voltage gain is calculated as shown below: VG = (1 + HC) × (1 + D/64) / 4 D = CC0 × 25 + CC1 × 24 + CC2 × 23 + CC3 × 22 + CC4 × 21 + CC5 × 20 Where HC is 1 or 0, and D is the binary value of CC[0:5]. So, the VG could be regarded as a floating-point number with 1-bit exponent HC and 6-bit mantissa CC[0:5]. {HC,CC[0:5]} divides the programmable voltage gain VG into 128 steps and two sub-bands: Low voltage sub-band (HC = 0): VG = 1/4 ~ 127/256, linearly divided into 64 steps High voltage sub-band (HC = 1): VG = 1/2 ~ 127/128, linearly divided into 64 steps • CM: In addition to determining the ratio IOUT,target/Iref, CM limits the output current range. High Current Multiplier (CM = 1): IOUT,target/Iref = 15, suitable for output current range IOUT = 10 mA to 120 mA. Low Current Multiplier (CM = 0): IOUT,target/Iref = 5, suitable for output current range IOUT = 5 mA to 40 mA • CG: The total Current Gain is defined as the following. VR-EXT = 1.26 V × VG Iref = VR-EXT/Rext, if the external resistor, Rext, is connected to ground. IOUT,target = Iref × 15 × 3CM – 1 = 1.26 V/Rext × VG × 15 × 3CM – 1 = (1.26 V/Rext × 15) × CG CG = VG × 3CM – 1 Therefore, CG = (1/12) to (127/128), and it is divided into 256 steps. If CG = 127/128 = 0.992, the IOUT,target-Rext. Examples • Configuration Code {CM, HC, CC[0:5]} = {1,1,111111} VG = 127/128 = 0.992 and CG = VG × 30 = VG = 0.992 • Configuration Code = {1,1,000000} VG = (1 + 1) × (1 + 0/64)/4 = 1/2 = 0.5, and CG = 0.5 • Configuration Code = {0,0,000000} VG = (1 + 0) × (1 + 0/64)/4 = 1/4, and CG = (1/4) × 3–1 = 1/12 After power on, the default value of the Configuration Code {CM, HC, CC[0:5]} is {1,1,111111}. Therefore, VG = CG = 0.992. The relationship between the Configuration Code and the Current Gain is shown in Figure 19. 22 Submit Documentation Feedback Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 TLC5916, TLC5917 8-BIT CONSTANT-CURRENT LED SINK DRIVERS www.ti.com SLVS695A – JUNE 2007 – REVISED MARCH 2008 1.00 CM = 0 (Low Current Multiplier) Current Gain (CG) 0.75 HC = 1 (High Voltage SubBand) 0.50 HC = 0 (Low Voltage SubBand) HC = 0 (Low Voltage SubBand) HC = 1 (High Voltage SubBand) 0.25 CM = 1 (High Current Multiplier) 0.00 Configuration Code (CM, HC, CC[0:5]) in Binary Format Figure 19. Current Gain vs Configuration Code Copyright © 2007–2008, Texas Instruments Incorporated Product Folder Link(s): TLC5916 TLC5917 Submit Documentation Feedback 23 PACKAGE OPTION ADDENDUM www.ti.com 18-Sep-2008 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty TLC5916ID ACTIVE SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IDG4 ACTIVE SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IDR ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IDRG4 ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IN ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type TLC5916INE4 ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type TLC5916IPW ACTIVE TSSOP PW 16 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IPWG4 ACTIVE TSSOP PW 16 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IPWR ACTIVE TSSOP PW 16 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5916IPWRG4 ACTIVE TSSOP PW 16 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917ID ACTIVE SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IDG4 ACTIVE SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IDR ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IDRG4 ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IN ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type TLC5917INE4 ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type TLC5917IPW ACTIVE TSSOP PW 16 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IPWG4 ACTIVE TSSOP PW 16 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IPWR ACTIVE TSSOP PW 16 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC5917IPWRG4 ACTIVE TSSOP PW 16 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. Addendum-Page 1 PACKAGE OPTION ADDENDUM www.ti.com 18-Sep-2008 TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. OTHER QUALIFIED VERSIONS OF TLC5916, TLC5917 : • Automotive: TLC5916-Q1, TLC5917-Q1 NOTE: Qualified Version Definitions: • Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 19-Mar-2008 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing SPQ Reel Reel Diameter Width (mm) W1 (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant 10.3 2.1 8.0 16.0 Q1 TLC5916IDR SOIC D 16 2500 330.0 16.4 6.5 TLC5916IPWR TSSOP PW 16 2000 330.0 12.4 7.0 5.6 1.6 8.0 12.0 Q1 TLC5917IDR SOIC D 16 2500 330.0 16.4 6.5 10.3 2.1 8.0 16.0 Q1 TLC5917IPWR TSSOP PW 16 2000 330.0 12.4 7.0 5.6 1.6 8.0 12.0 Q1 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 19-Mar-2008 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) TLC5916IDR SOIC D 16 2500 333.2 345.9 28.6 TLC5916IPWR TSSOP PW 16 2000 346.0 346.0 29.0 TLC5917IDR SOIC D 16 2500 333.2 345.9 28.6 TLC5917IPWR TSSOP PW 16 2000 346.0 346.0 29.0 Pack Materials-Page 2 MECHANICAL DATA MTSS001C – JANUARY 1995 – REVISED FEBRUARY 1999 PW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PINS SHOWN 0,30 0,19 0,65 14 0,10 M 8 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 7 0°– 8° A 0,75 0,50 Seating Plane 0,15 0,05 1,20 MAX PINS ** 0,10 8 14 16 20 24 28 A MAX 3,10 5,10 5,10 6,60 7,90 9,80 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064/F 01/97 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-153 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated