TI TLC5916IPWRG4

www.ti.com
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
SLVS695A – JUNE 2007 – REVISED MARCH 2008
FEATURES
1
•
•
•
•
•
•
•
•
Eight Constant-Current Output Channels
Output Current Adjusted Through External
Resistor
Constant Output Current Range:
5 mA to 120 mA
Constant Output Current Invariant to Load
Voltage Change
Open Load, Short Load and Overtemperature
Detection
256-Step Programmable Global Current Gain
Excellent Output Current Accuracy:
– Between Channels: < ±3% (Max)
– Between ICs: < ±6% (Max)
Fast Response of Output Current
•
•
•
•
30-MHz Clock Frequency
Schmitt-Trigger Input
3.3-V or 5-V Supply Voltage
Thermal Shutdown for Overtemperature
Protection
APPLICATIONS
•
•
•
•
•
•
General LED Lighting Applications
LED Display Systems
LED Signage
Automotive LED Lighting
White Goods
Gaming Machines/Entertainment
DESCRIPTION/ORDERING INFORMATION
The TLC5916/TLC5917 is designed for LED displays and LED lighting applications with constant-current control
and open-load, shorted-load, and overtemperature detection. The TLC5916/TLC5917 contains an 8-bit shift
register and data latches, which convert serial input data into parallel output format. At the output stage, eight
regulated current ports are designed to provide uniform and constant current for driving LEDs within a wide range
of VF variations. Used in system design for LED display applications, e.g., LED panels, it provides great flexibility
and device performance. Users can adjust the output current from 5 mA to 120 mA through an external resistor,
Rext, which gives flexibility in controlling the light intensity of LEDs. The devices are designed for up to 17 V at
the output port. The high clock frequency, 30 MHz, also satisfies the system requirements of high-volume data
transmission.
The TLC5916/TLC5917 provides a Special Mode in which two functions are included, Error Detection and
Current Gain Control. There are two operation modes and three phases: Normal Mode phase, Mode Switching
transition phase, and Special Mode phase. The signal on the multiple function pin OE(ED2) is monitored to
determine the mode. When an one-clock-wide pulse appears on OE(ED2), the device enters the Mode Switching
phase. At this time, the voltage level on LE(ED1) determines the mode to which the TLC5916/TLC5917 switches.
In the Normal Mode phase, the serial data can be transferred into TLC5916/TLC5917 via the pin SDI, shifted in
the shift register, and transferred out via the pin SDO. LE(ED1) can latch the serial data in the shift register to the
output latch. OE(ED2) enables the output drivers to sink current.
In the Special Mode phase, the low-voltage-level signal OE(ED2) can enable output channels and detect the
status of the output current, to determine if the driving current level is sufficient. The detected Error Status is
loaded into the 8-bit shift register and shifted out via the pin SDO, synchronous to the CLK signal. The system
controller can read the error status and determine whether or not the LEDs are properly lit.
In the Special Mode phase, the TLC5916/TLC5917 allows users to adjust the output current level by setting a
runtime-programmable Configuration Code. The code is sent into the TLC5916/TLC5917 via SDI. The positive
pulse of LE(ED1) latches the code in the shift register into a built-in 8-bit configuration latch, instead of the output
latch. The code affects the voltage at the terminal R-EXT and controls the output-current regulator. The output
current can be finely adjusted by a gain ranging from 1/12 to 127/128 in 256 steps. Therefore, the current skew
between ICs can be compensated within less than 1%. This feature is suitable for white balancing in LED color
display panels.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2007–2008, Texas Instruments Incorporated
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION (1)
SHORT TO VLED
DETECTION
TA
PACKAGE (2)
PDIP – N
No
SOIC – D
TSSOP – PW
–40°C to 125°C
PDIP – N
Yes
SOIC – D
TSSOP – PW
(1)
(2)
ORDERABLE PART NUMBER
Tube of 25
TLC5916IN
Tube of 40
TLC5916ID
Reel of 2500
TLC5916IDR
Tube of 90
TLC5916IPW
Reel of 2000
TLC5916IPWR
Tube of 25
TLC5917IN
Tube of 40
TLC5917ID
Reel of 2500
TLC5917IDR
Tube of 90
TLC5917IPW
Reel of 2000
TLC5917IPWR
TOP-SIDE MARKING
TLC5916IN
TLC5916I
Y5916
TLC5917IN
TLC5917I
Y5917
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
BLOCK DIAGRAM
OUT0
OUT1
OUT6
OUT7
I/O Regulator
R-EXT
8
OE(ED2)
Output Driver and
Error Detection
Control
Logic
8
8
VDD
8-Bit Output
Latch
LE(ED1)
Configuration
Latches
8
CLK
8
SDI
8-Bit Shift
Register
SDO
8
2
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
D, N, OR PW PACKAGE
(TOP VIEW)
GND
SDI
CLK
LE(ED1)
OUT0
OUT1
OUT2
OUT3
1
16
2
15
3
14
4
5
13
12
6
11
7
10
8
9
VDD
R-EXT
SDO
OE(ED2)
OUT7
OUT6
OUT5
OUT4
Terminal Descriptions
TERMINAL
NAME
DESCRIPTION
CLK
Clock input for data shift on rising edge
GND
Ground for control logic and current sink
LE(ED1)
Data strobe input
Serial data is transferred to the respective latch when LE(ED1) is high. The data is latched when LE(ED1) goes low.
Also, a control signal input for an Error Detection Mode and Current Adjust Mode (see Timing Diagram). LE(ED1) has
an internal pulldown.
OE(ED2)
Output enable. When OE(ED2) is active (low), the output drivers are enabled; when OE(ED2) is high, all output drivers
are turned OFF (blanked). Also, a control signal input for an Error Detection Mode and Current Adjust Mode (see
Figure 1). OE(ED2) has an internal pullup.
OUT0–OUT7
Constant-current outputs
R-EXT
Input used to connect an external resistor for setting up all output currents
SDI
Serial-data input to the Shift register
SDO
Serial-data output to the following SDI of next driver IC or to the microcontroller
VDD
Supply voltage
Diagnostic Features
OVERTEMPERATURE
DETECTION
OPEN-LOAD
DETECTION
SHORT TO GND
DETECTION
TLC5916
X
X
X
TLC5917
X
X
X
DEVICE (1)
(1)
SHORT TO VLED
DETECTION
X
The device has one single error register for all these conditions (one error bit per channel).
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
3
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Timing Diagram
0
1
2
3
4
5
6
7
CLK
OE(ED2)
1
LE(ED1)
0
SDI
off
OUT0
on
off
OUT1
on
off
OUT2
on
off
OUT3
on
off
OUT7
on
Don't care
SDO
Figure 1. Normal Mode
Truth Table in Normal Mode
CLK
LE(ED1)
OE(ED2)
SDI
OUT0...OUT7
SDO
↑
H
L
Dn
Dn...Dn – 7
Dn – 7
↑
L
L
Dn + 1
No change
Dn – 6
↑
H
L
Dn + 2
Dn + 2...Dn – 5
Dn – 5
↓
X
L
Dn + 3
Dn + 2...Dn – 5
Dn – 5
↓
X
H
Dn + 3
Off
Dn – 5
The signal sequence shown in Figure 2 makes the TLC5916/TLC5917 enter Current Adjust and Error Detection
Mode.
1
2
3
4
5
OE(ED2)
1
0
1
1
1
LE(ED1)
0
0
0
1
0
CLK
Figure 2. Switching to Special Mode
4
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
In the Current Adjust Mode, sending the positive pulse of LE(ED1), the content of the shift register (a current
adjust code) is written to the 8-bit configuration latch (see Figure 3).
0
1
2
6
3
7
CLK
OE(ED2)
1
LE(ED1)
0
8-bit Configuration Code
SDI
Figure 3. Writing Configuration Code
When the TLC5916/TLC5917 is in the Error Detection Mode, the signal sequence shown in Figure 4 enables a
system controller to read error status codes through SDO.
1
2
3
CLK
>2 µs
OE(ED2)
1
LE(ED1)
0
SDO
Error Status Code
Figure 4. Reading Error Status Code
The signal sequence shown in Figure 5 makes TLC5916/TLC5917 resume the Normal Mode. Switching to
Normal Mode resets all internal Error Status registers. OE(ED2) always enables the output port, whether the
TLC5916/TLC5917 enters Current Adjust Mode or not.
1
2
3
4
5
OE(ED2)
1
0
1
1
1
LE(ED1)
0
0
0
0
0
CLK
Figure 5. Switching to Normal Mode
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
5
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
0
7
V
Input voltage range
–0.4
VDD + 0.4
V
VO
Output voltage range
–0.5
20
V
fclk
Clock frequency
25
MHz
IOUT
Output current
120
mA
IGND
GND terminal current
960
mA
TA
Operating free-air temperature range
–40
125
°C
TJ
Operating junction temperature range
–40
150
°C
Tstg
Storage temperature range
–55
150
°C
ESD
Electrostatic discharge capability, V(HBMESD)
1.5
kV
VDD
Supply voltage range
VI
100 pF, 1.5 kΩ
UNIT
Power Dissipation and Thermal Impedance
MIN
D package
PD
Power dissipation
Mounted on JEDEC 4-layer board (JESD 51-7),
No airflow, TA = 25°C, TJ = 125°C
Mounted on JEDEC 1-layer board (JESD 51-3),
No airflow
θJA
Thermal impedance,
junction to free air
N package
D package
103
N package
148
PW package
176
PW package
6
Submit Documentation Feedback
1
0.9
N package
UNIT
1.5
PW package
D package
Mounted on JEDEC 4-layer board (JESD 51-7),
No airflow
MAX
66
W
°C/W
97
112
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Recommended Operating Conditions
CONDITIONS
VDD
Supply voltage
VO
Supply voltage to output pins
MIN
MAX
3
5.5
V
17
V
OUT0–OUT7
VO ≥ 0.6 V
5
UNIT
IO
Output current
DC test circuit
IOH
High-level output current source
SDO shorted to GND
–1
mA
IOL
Low-level output current sink
SDO shorted to VCC
1
mA
VIH
High-level input voltage
CLK, OE(ED2), LE(ED1), and SDI
0.7 × VDD
VDD
V
VIL
Low-level input voltage
CLK, OE(ED2), LE(ED1), and SDI
0
0.3 × VDD
V
VO ≥ 1 V
120
mA
Recommended Timing
VDD = 3 V to 5.5 V (unless otherwise noted)
CONDITIONS
MIN
MAX
UNIT
tw(L)
LE(ED1) pulse duration
Normal Mode
20
ns
tw(CLK)
CLK pulse duration
Normal Mode
20
ns
tw(OE)
OE(ED2) pulse duration
tsu(D)
Setup time for SDI
Normal Mode
th(D)
Hold time for SDI
tsu(L)
Setup time for LE(ED1)
th(L)
Normal Mode, IOUT < 60 mA
500
Normal Mode, IOUT > 60 mA
700
ns
3
ns
Normal Mode
2
ns
Normal Mode
15
ns
Hold time for LE(ED1)
Normal Mode
15
ns
tw(CLK)
CLK pulse duration
Error Detection Mode
20
ns
tw(ED2)
OE(ED2) pulse duration
Error Detection Mode
2000
ns
tsu(ED1)
Setup time for LE(ED1)
Error Detection Mode
4
ns
th(ED1)
Hold time for LE(ED1)
Error Detection Mode
10
ns
tsu(ED2)
Setup time for OE(ED2)
Error Detection Mode
6
ns
th(ED2)
Hold time for OE(ED2)
Error Detection Mode
10
fCLK
Clock frequency
Cascade operation
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
ns
30
Submit Documentation Feedback
MHz
7
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Electrical Characteristics
VDD = 3 V, TJ = –40°C to 125°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP (1)
UNIT
Input voltage
VO
Supply voltage to the output pins
IO
Output current
IOH
High-level output current, source
IOL
Low-level output current, sink
VIH
High-level input voltage
0.7 × VDD
VDD
V
VIL
Low-level input voltage
GND
0.3 × VDD
V
Ileak
Output leakage current
VOH = 17 V
VOH
High-level output voltage
SDO, IOL = –1 mA
VOL
Low-level output voltage
SDO, IOH = 1 mA
Output current 1
VOUT = 0.6 V, Rext = 720 Ω,
CG = 0.992
26
Output current error, die-die
IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω,
TJ = 25°C
±3
±6
%
Output current skew,
channel-to-channel
IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω,
TJ = 25°C
±1.5
±3
%
Output current 2
VO = 0.8 V, Rext = 360 Ω, CG = 0.992
52
Output current error, die-die
IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω,
TJ = 25°C
±2
±6
%
Output current skew,
channel-to-channel
IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω,
TJ = 25°C
±1.5
±3
%
VO = 1 V to 3 V, IO = 26 mA
±0.1
IO(1)
IO(2)
IOUT vs
VOUT
Output current vs
output voltage regulation
3
MAX
VDD
VO ≥ 0.6 V
–1
1
mA
TJ = 25°C
0.5
TJ = 125°C
2
VDD – 0.4
500
LE(ED1)
500
Restart temperature hysteresis
IOUT,Th1
Threshold current for open error
detection
IOUT,Th2
175
V
mA
mA
%/V
±1
150
µA
V
0.4
VDD = 3.0 V to 5.5 V,
IO = 26 mA/120 mA
mA
mA
OE(ED2)
Thys
V
120
Pulldown resistance
Overtemperature shutdown (2)
V
17
5
VO ≥ 1 V
Pullup resistance
Tsd
5.5
kΩ
kΩ
200
°C
15
°C
IOUT,target = 26 mA
0.5 × Itarget
%
Threshold current for open error
detection
IOUT,target = 52 mA
0.5 × Itarget
%
IOUT,Th3
Threshold current for open error
detection
IOUT,target = 104 mA
0.5 × Itarget
%
IOUT,Th
Threshold current for open error
detection
IOUT,target = 5 mA to 120 mA
0.5 × Itarget
%
VOUT,TTh
Trigger threshold voltage for
short-error detection
(TLC5917 only)
IOUT,target = 5 mA to 120 mA
2.5
VOUT,RTh
Return threshold voltage for
short-error detection
(TLC5917 only)
IOUT,target = 5 mA to 120 mA
2.2
IDD
(1)
(2)
8
Supply current
2.7
3.1
V
V
Rext = Open
5
10
Rext = 720 Ω
8
14
Rext = 360 Ω
11
18
Rext = 180 Ω
16
22
mA
Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
Specified by design.
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Electrical Characteristics
VDD = 5.5 V, TJ = –40°C to 125°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP (1)
UNIT
Input voltage
VO
Supply voltage to the output pins
IO
Output current
IOH
High-level output current, source
IOL
Low-level output current, sink
VIH
High-level input voltage
0.7 × VDD
VDD
V
VIL
Low-level input voltage
GND
0.3 × VDD
V
Ileak
Output leakage current
VOH = 17 V
VOH
High-level output voltage
SDO, IOL = –1 mA
VOL
Low-level output voltage
SDO, IOH = 1 mA
Output current 1
VOUT = 0.6 V, Rext = 720 Ω,
CG = 0.992
26
Output current error, die-die
IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω,
TJ = 25°C
±3
±6
%
Output current skew,
channel-to-channel
IOL = 26 mA, VO = 0.6 V, Rext = 720 Ω,
TJ = 25°C
±1.5
±3
%
Output current 2
VO = 0.8 V, Rext = 360 Ω, CG = 0.992
52
Output current error, die-die
IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω,
TJ = 25°C
±2
±6
%
Output current skew,
channel-to-channel
IOL = 52 mA, VO = 0.8 V, Rext = 360 Ω,
TJ = 25°C
±1.5
±3
%
VO = 1 V to 3 V , IO = 26 mA
±0.1
IO(1)
IO(2)
IOUT vs
VOUT
Output current vs
output voltage regulation
3
MAX
VDD
VO ≥ 0.6 V
–1
1
mA
TJ = 25°C
0.5
TJ = 125°C
2
VDD – 0.4
500
LE(ED1),
500
Restart temperature hysteresis
IOUT,Th1
Threshold current for open error
detection
IOUT,Th2
175
V
mA
mA
%/V
±1
150
µA
V
0.4
VDD = 3.0 V to 5.5 V,
IO = 26 mA/120 mA
mA
mA
OE(ED2),
Thys
V
120
Pulldown resistance
Overtemperature shutdown (2)
V
17
5
VO ≥ 1 V
Pullup resistance
Tsd
5.5
kΩ
kΩ
200
°C
15
°C
IOUT,target = 26 mA
0.5 × Itarget
%
Threshold current for open error
detection
IOUT,target = 52 mA
0.5 × Itarget
%
IOUT,Th3
Threshold current for open error
detection
IOUT,target = 104 mA
0.5 × Itarget
%
IOUT,Th
Threshold current for open error
detection
IOUT,target = 5 mA to 120 mA
0.5 × Itarget
%
VOUT,TTh
Trigger threshold voltage for
short-error detection
(TLC5917 only)
IOUT,target = 5 mA to 120 mA
2.5
VOUT,RTh
Return threshold voltage for
short-error detection
(TLC5917 only)
IOUT,target = 5 mA to 120 mA
2.2
IDD
(1)
(2)
Supply current
2.7
3.1
V
V
Rext = Open
6
10
Rext = 720 Ω
11
14
Rext = 360 Ω
13
18
Rext = 180 Ω
19
24
mA
Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
Specified by design.
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
9
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Switching Characteristics
VDD = 3 V, TJ = –40°C to 125°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP (1)
MAX
UNIT
tPLH1
Low-to-high propagation delay time, CLK to OUTn
40
65
95
ns
tPLH2
Low-to-high propagation delay time, LE(ED1) to OUTn
40
65
95
ns
tPLH3
Low-to-high propagation delay time, OE(ED2) to OUTn
40
65
95
ns
tPLH4
Low-to-high propagation delay time, CLK to SDO
12
20
30
ns
tPHL1
High-to-low propagation delay time, CLK to OUTn
300
365
ns
tPHL2
High-to-low propagation delay time, LE(ED1) to OUTn
300
365
ns
tPHL3
High-to-low propagation delay time, OE(ED2) to OUTn
300
365
ns
tPHL4
High-to-low propagation delay time, CLK to SDO
12
20
30
ns
tw(CLK)
Pulse duration, CLK
20
ns
tw(L)
Pulse duration, LE(ED1)
20
ns
tw(OE)
Pulse duration, OE(ED2)
500
ns
tw(ED2)
Pulse duration, OE(ED2) in Error Detection Mode
2
µs
th(ED1,ED2)
Hold time, LE(ED1) and OE(ED2)
10
ns
th(D)
Hold time, SDI
2
ns
tsu(D,ED1)
Setup time, SDI, LE(ED1)
3
ns
tsu(ED2)
Setup time, OE(ED2)
8.5
ns
th(L)
Hold time, LE(ED1), Normal Mode
15
ns
tsu(L)
Setup time, LE(ED1), Normal Mode
15
ns
(2)
tr
Rise time, CLK
tf
Fall time, CLK (2)
tor
Rise time, outputs (off)
tor
Rise time, outputs (off), TJ = 25°C
tof
Rise time, outputs (on)
tof
Rise time, outputs (on), TJ = 25°C
fCLK
Clock frequency
(1)
(2)
10
VIH = VDD, VIL = GND,
Rext = 360 Ω, VL = 4 V,
RL = 44 Ω, CL = 10 pF,
CG = 0.992
40
100
Cascade operation
500
ns
500
ns
85
105
ns
83
100
ns
280
370
ns
170
225
ns
30
MHz
Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
If the devices are connected in cascade and tr or tf is large, it may be critical to achieve the timing required for data transfer between two
cascaded devices.
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Switching Characteristics
VDD = 5.5 V, TJ = –40°C to 125°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP (1)
MAX
UNIT
tPLH1
Low-to-high propagation delay time, CLK to OUTn
40
65
95
ns
tPLH2
Low-to-high propagation delay time, LE(ED1) to OUTn
40
65
95
ns
tPLH3
Low-to-high propagation delay time, OE(ED2) to OUTn
40
65
95
ns
tPLH4
Low-to-high propagation delay time, CLK to SDO
8
20
30
ns
tPHL1
High-to-low propagation delay time, CLK to OUTn
300
365
ns
tPHL2
High-to-low propagation delay time, LE(ED1) to OUTn
300
365
ns
tPHL3
High-to-low propagation delay time, OE(ED2) to OUTn
300
365
ns
tPHL4
High-to-low propagation delay time, CLK to SDO
20
30
ns
tw(CLK)
Pulse duration, CLK
20
ns
tw(L)
Pulse duration, LE(ED1)
20
ns
tw(OE)
Pulse duration, OE(ED2)
500
ns
tw(ED2)
Pulse duration, OE(ED2) in Error Detection Mode
2
µs
th(D,ED1,ED2)
Hold time, SDI, LE(ED1), and OE(ED2)
10
ns
th(D)
Hold time, SDI
2
ns
tsu(D,ED1)
Setup time, SDI, LE(ED1)
3
ns
tsu(ED2)
Setup time, OE(ED2)
8.5
ns
th(L)
Hold time, LE(ED1), Normal Mode
15
ns
tsu(L)
Setup time, LE(ED1), Normal Mode
15
ns
Rise time, CLK
tf
Fall time, CLK (2)
tor
Rise time, outputs (off)
tor
Rise time, outputs (off), TJ = 25°C
tof
Rise time, outputs (on)
tof
Rise time, outputs (on), TJ = 25°C
fCLK
Clock frequency
(2)
VIH = VDD, VIL = GND,
Rext = 360 Ω, VL = 4 V,
RL = 44 Ω, CL = 10 pF,
CG = 0.992
(2)
tr
(1)
8
40
100
Cascade operation
500
ns
500
ns
85
105
ns
83
100
ns
280
370
ns
170
225
ns
30
MHz
Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
If the devices are connected in cascade and tr or tf is large, it may be critical to achieve the timing required for data transfer between two
cascaded devices.
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
11
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
PARAMETER MEASUREMENT INFORMATION
IDD
VDD
OE(ED2)
IIH, IIL
IOUT
OUT0
CLK
LE(ED1)
OUT7
SDI
VIH, VIL
R-EXT
GND
SDO
Iref
Figure 6. Test Circuit for Electrical Characteristics
IDD
IOUT
VDD
VIH, VIL
OE(ED2)
CLK
LE(ED1)
Function
Generator
OUT0
OUT7
RL
CL
SDI
Logic Input
Waveform
VIH = 5 V
VIL = 0V
R-EXT
GND
SDO
Iref
CL
VL
Figure 7. Test Circuit for Switching Characteristics
12
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
PARAMETER MEASUREMENT INFORMATION (continued)
tw(CLK)
50%
CLK
50%
tsu(D)
SDI
50%
50%
th(D)
50%
50%
tPLH4, tPHL4
50%
SDO
tw(L)
50%
LE(ED1)
tsu(L)
th(L)
OE(ED2)
LOW
tPLH2, tPHL2
Output off
OUTn
50%
Output on
tPLH1, tPHL1
tw(OE)
OE(ED2)
HIGH
50%
50%
tPLH3
tPHL3
Output off
80%
80%
OUTn
50%
50%
20%
20%
tof
tor
Figure 8. Normal Mode Timing Waveforms
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
13
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
PARAMETER MEASUREMENT INFORMATION (continued)
tw(CLK)
50%
CLK
tsu(ED2)
OE(ED2)
th(ED2)
50%
tsu(ED1)
LE(ED1)
th(ED1)
50%
2 CLK
Figure 9. Switching to Special Mode Timing Waveforms
CLK
OE(ED2)
50%
50%
tw(ED2)
Figure 10. Reading Error Status Code Timing Waveforms
14
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
TYPICAL CHARACTERISTICS
LE = 5 V (active)
OE = GND (active)
CLK
OUTn
Figure 11. Response Time, CLK to OUTn
Turn on only one channel
Channel 1
OE
OUT1
Figure 12. Response Time, OE to OUT1
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
15
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
TYPICAL CHARACTERISTICS (continued)
Turn on only one channel
Channel 8
OE
OUT7
Figure 13. Response Time, OE to OUT7
16
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
APPLICATION INFORMATION
Operating Principles
Constant Current
In LED display applications, TLC5916/TLC5917 provides nearly no current variations from channel to channel
and from IC to IC. While IOUT ≤ 100 mA, the maximum current skew between channels is less than ±3% and
between ICs is less than ±6%.
Adjusting Output Current
TLC5916/TLC5917 scales up the reference current, Iref, set by the external resistor Rext to sink a current, Iout, at
each output port. Users can follow the below formulas to calculate the target output current IOUT,target in the
saturation region:
VR-EXT = 1.26 V × VG
Iref = VR-EXT/Rext, if another end of the external resistor Rext is connected to ground
IOUT,target = Iref × 15 × 3CM – 1
Where Rext is the resistance of the external resistor connected to the R-EXT terminal, and VR-EXT is the voltage of
R-EXT, which is controlled by the programmable voltage gain (VG), which is defined by the Configuration Code.
The Current Multiplier (CM) determines that the ratio IOUT,target/Iref is 15 or 5. After power on, the default value of
VG is 127/128 = 0.992, and the default value of CM is 1, so that the ratio IOUT,target/Iref = 15. Based on the default
VG and CM:
VR-EXT = 1.26 V × 127/128 = 1.25 V
IOUT,target = (1.25 V/Rext) × 15
Therefore, the default current is approximately 52 mA at 360 Ω and 26 mA at 720 Ω. The default relationship
after power on between IOUT,target and Rext is shown in Figure 14.
140
IOUT – mA
120
100
80
40
0
0 500
1000
1500
2000
2500
3000
3500 4000
Rext – Ω
Figure 14. Default Relationship Curve Between IOUT,target and Rext After Power Up
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
17
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Operation Phases
Operation Mode Switching
To switch between its two modes, TLC5916/TLC5917 monitors the signal OE(ED2). When an one-clock-wide
pulse of OE(ED2) appears, TLC5916/TLC5917 enters the two-clock-period transition phase, the Mode Switching
phase. After power on, the default operation mode is the Normal Mode (see Figure 15).
Switching to Special Mode
1
2
3
Switching to Normal Mode
4
5
1
CLK
2
3
4
5
CLK
OE(ED2)
1
0
1
1
1
OE(ED2)
1
0
1
1
1
LE(ED1)
0
0
0
1
0
LE(ED1)
0
0
0
0
0
Actual Mode
Phase (Normal or Special)
Mode
Switching
Special
Mode
Actual Mode
Phase (Normal or Special)
Mode
Switching
Normal
Mode
Figure 15. Mode Switching
As shown in Figure 15, once a one-clock-wide short pulse (101) of OE(ED2) appears, TLC5916/TLC5917 enters
the Mode Switching phase. At the fourth rising edge of CLK, if LE(ED1) is sampled as voltage high,
TLC5916/TLC5917 switches to Special Mode; otherwise, it switches to Normal Mode. The signal LE(ED1)
between the third and the fifth rising edges of CLK cannot latch any data. Its level is used only to determine into
which mode to switch. However, the short pulse of OE(ED2) can still enable the output ports. During mode
switching, the serial data can still be transferred through SDI and shifted out from SDO.
NOTES:
1. The signal sequence for the mode switching may be used frequently to ensure that TLC5916/TLC5917 is in
the proper mode.
2. The 1 and 0 on the LE(ED1) signal are sampled at the rising edge of CLK. The X means its level does not
affect the result of mode switching mechanism.
3. After power on, the default operation mode is Normal Mode.
Normal Mode Phase
Serial data is transferred into TLC5916/TLC5917 via SDI, shifted in the Shift Register, and output via SDO.
LE(ED1) can latch the serial data in the Shift Register to the Output Latch. OE(ED2) enables the output drivers to
sink current. These functions differ only as described in Operation Mode Switching, in which case, a short pulse
triggers TLC5916/TLC5917 to switch the operation mode. However, as long as LE(ED1) is high in the Mode
Switching phase, TLC5916/TLC5917 remains in the Normal Mode, as if no mode switching occurred.
Special Mode Phase
In the Special Mode, as long as OE(ED2) is not low, the serial data is shifted to the Shift Register via SDI and
shifted out via SDO, as in the Normal Mode. However, there are two differences between the Special Mode and
the Normal Mode, as shown in the following sections.
18
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Reading Error Status Code in Special Mode
When OE(ED2) is pulled low while in Special Mode, error detection and load error status codes are loaded into
the Shift Register, in addition to enabling output ports to sink current. Figure 16 shows the timing sequence for
error detection. The 0 and 1 signal levels are sampled at the rising edge of each CLK. At least three zeros must
be sampled at the voltage low signal OE(ED2). Immediately after the second zero is sampled, the data input
source of the Shift Register changes to the 8-bit parallel Error Status Code register, instead of from the serial
data on SDI. Normally, the error status codes are generated at least 2 µs after the falling edge of OE(ED2). The
occurrence of the third or later zero saves the detected error status codes into the Shift Register. Therefore,
when OE(ED2) is low, the serial data cannot be shifted into TLC5916/TLC5917 via SDI. When OE(ED2) is pulled
high, the data input source of the Shift Register is changed back to SDI. At the same time, the output ports are
disabled and the error detection is completed. Then, the error status codes saved in the Shift Register can be
shifted out via SDO bit by bit along with CLK, as well as the new serial data can be shifted into
TLC5916/TLC5917 via SDI.
While in Special Mode, the TLC5916/TLC5917 cannot simultaneously transfer serial data and detect LED load
error status.
1
2
3
CLK
>2 µs
OE(ED2)
1
0
0
0
0
0
1
1
1
1
LE(ED1)
0
0
0
0
0
0
0
0
0
0
Error Status Code
SDO
Bit 7
Data source of
shift register
Error Detection
SDI
Bit 6
Bit 5
Bit 4
SDI
Figure 16. Reading Error Status Code
Writing Configuration Code in Special Mode
When in Special Mode, the active high signal LE(ED1) latches the serial data in the Shift Register to the
Configuration Latch, instead of the Output Latch. The latched serial data is used as the Configuration Code.
The code is stored until power off or the Configuration Latch is rewritten. As shown in Figure 17, the timing for
writing the Configuration Code is the same as the timing in the Normal Mode to latching output channel data.
Both the Configuration Code and Error Status Code are transferred in the common 8-bit Shift Register. Users
must pay attention to the sequence of error detection and current adjustment to avoid the Configuration Code
being overwritten by Error Status Code.
0
1
2
3
4
5
6
7
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
CLK
OE(ED2)
1
LE(ED1)
0
Bit 7 Bit 6
SDI
8-Bit Configuration Code
Figure 17. Writing Configuration Code
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
19
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Open-Circuit Detection Principle
The LED Open-Circuit Detection compares the effective current level Iout with the open load detection threshold
current IOUT,Th. If IOUT is below the IOUT,Th threshold, the TLC5916/TLC5917 detects an open-load condition. This
error status can be read as an error status code in the Special Mode. For open-circuit error detection, a channel
must be on.
Table 1. Open-Circuit Detection
STATE OF OUTPUT PORT
CONDITION OF OUTPUT
CURRENT
ERROR STATUS CODE
MEANING
IOUT = 0 mA
0
Detection not possible
IOUT < IOUT,Th (1)
0
Open circuit
Channel n error status bit 1
Normal
Off
On
(1)
IOUT ≥ IOUT,Th
(1)
IOUT,Th = 0.5 × IOUT,target (typical)
Short-Circuit Detection Principle (TLC5917 Only)
The LED short-circuit detection compares the effective voltage level (VOUT) with the shorted-load detection
threshold voltages VOUT,TTh and VOUT,RTh. If VOUT is above the VOUT,TTh threshold, the TLC5917 detects an
shorted-load condition. If VOUT is below the VOUT,RTh threshold, no error is detected/error bit is reset. This error
status can be read as an error status code in the Special Mode. For short-circuit error detection, a channel must
be on.
Table 2. Shorted-Load Detection
STATE OF OUTPUT PORT
CONDITION OF OUTPUT
VOLTAGE
ERROR STATUS CODE
MEANING
Off
On
IOUT = 0 mA
0
Detection not possible
VOUT ≥ VOUT,TTh
0
Short circuit
VOUT < VOUT,RTh
1
Normal
Minimum
Return
Threshold
Minimum
Trigger
Threshold
2.2 V
2.5 V
Maximum
Trigger
Threshold
No Fault
Short Fault
3.1 V
VOUT,RTh
VOUT,TTh
VOUT
Figure 18. Short-Circuit Detection Principle
20
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
Overtemperature Detection and Shutdown
TLC5916/TLC5917 is equipped with a global overtemperature sensor and eight individual, channel-specific,
overtemperature sensors.
• When the global sensor reaches the trip temperature, all output channels are shut down, and the error status
is stored in the internal Error Status register of every channel. After shutdown, the channels automatically
restart after cooling down, if the control signal (output latch) remains on. The stored error status is not reset
after cooling down and can be read out as the error status code in the Special Mode.
• When one of the channel-specific sensors reaches trip temperature, only the affected output channel is shut
down, and the error status is stored only in the internal Error Status register of the affected channel. After
shutdown, the channel automatically restarts after cooling down, if the control signal (output latch) remains
on. The stored error status is not reset after cooling down and can be read out as error status code in the
Special Mode.
For channel-specific overtemperature error detection, a channel must be on.
The error status code is reset when TLC5916/TLC5917 returns to Normal Mode.
Table 3. Overtemperature Detection (1)
STATE OF OUTPUT PORT
(1)
CONDITION
ERROR STATUS CODE
MEANING
Off
IOUT = 0 mA
0
On
On → all channels
Off
Tj < Tj,trip global
1
Normal
Tj > Tj,trip global
All error status bits = 0
Global overtemperature
On
On → Off
Tj < Tj,trip channel n
1
Normal
Tj > Tj,trip channel n
Channel n error status bit = 0
Channel n overtemperature
The global shutdown threshold temperature is approximately 170°C.
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
21
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
8-Bit Configuration Code and Current Gain
Bit definition of the Configuration Code in the Configuration Latch is shown in Table 4.
Table 4. Bit Definition of 8-Bit Configuration Code
Meaning
Default
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
CM
HC
CC0
CC1
CC2
CC3
CC4
CC5
1
1
1
1
1
1
1
1
Bit 7 is first sent into TLC5916/TLC5917 via SDI. Bits 1 to 7 {HC, CC[0:5]} determine the voltage gain (VG) that
affects the voltage at R-EXT and indirectly affects the reference current, Iref, flowing through the external resistor
at R-EXT. Bit 0 is the Current Multiplier (CM) that determines the ratio IOUT,target/Iref. Each combination of VG and
CM gives a specific Current Gain (CG).
• VG: the relationship between {HC,CC[0:5]} and the voltage gain is calculated as shown below:
VG = (1 + HC) × (1 + D/64) / 4
D = CC0 × 25 + CC1 × 24 + CC2 × 23 + CC3 × 22 + CC4 × 21 + CC5 × 20
Where HC is 1 or 0, and D is the binary value of CC[0:5]. So, the VG could be regarded as a floating-point
number with 1-bit exponent HC and 6-bit mantissa CC[0:5]. {HC,CC[0:5]} divides the programmable voltage
gain VG into 128 steps and two sub-bands:
Low voltage sub-band (HC = 0): VG = 1/4 ~ 127/256, linearly divided into 64 steps
High voltage sub-band (HC = 1): VG = 1/2 ~ 127/128, linearly divided into 64 steps
• CM: In addition to determining the ratio IOUT,target/Iref, CM limits the output current range.
High Current Multiplier (CM = 1): IOUT,target/Iref = 15, suitable for output current range IOUT = 10 mA to 120 mA.
Low Current Multiplier (CM = 0): IOUT,target/Iref = 5, suitable for output current range IOUT = 5 mA to 40 mA
• CG: The total Current Gain is defined as the following.
VR-EXT = 1.26 V × VG
Iref = VR-EXT/Rext, if the external resistor, Rext, is connected to ground.
IOUT,target = Iref × 15 × 3CM – 1 = 1.26 V/Rext × VG × 15 × 3CM – 1 = (1.26 V/Rext × 15) × CG
CG = VG × 3CM – 1
Therefore, CG = (1/12) to (127/128), and it is divided into 256 steps. If CG = 127/128 = 0.992, the
IOUT,target-Rext.
Examples
• Configuration Code {CM, HC, CC[0:5]} = {1,1,111111}
VG = 127/128 = 0.992 and CG = VG × 30 = VG = 0.992
• Configuration Code = {1,1,000000}
VG = (1 + 1) × (1 + 0/64)/4 = 1/2 = 0.5, and CG = 0.5
• Configuration Code = {0,0,000000}
VG = (1 + 0) × (1 + 0/64)/4 = 1/4, and CG = (1/4) × 3–1 = 1/12
After power on, the default value of the Configuration Code {CM, HC, CC[0:5]} is {1,1,111111}. Therefore,
VG = CG = 0.992. The relationship between the Configuration Code and the Current Gain is shown in Figure 19.
22
Submit Documentation Feedback
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
TLC5916, TLC5917
8-BIT CONSTANT-CURRENT LED SINK DRIVERS
www.ti.com
SLVS695A – JUNE 2007 – REVISED MARCH 2008
1.00
CM = 0 (Low Current Multiplier)
Current Gain (CG)
0.75
HC = 1 (High
Voltage SubBand)
0.50
HC = 0 (Low
Voltage SubBand)
HC = 0 (Low
Voltage SubBand)
HC = 1 (High
Voltage SubBand)
0.25
CM = 1 (High Current Multiplier)
0.00
Configuration Code (CM, HC, CC[0:5]) in Binary Format
Figure 19. Current Gain vs Configuration Code
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TLC5916 TLC5917
Submit Documentation Feedback
23
PACKAGE OPTION ADDENDUM
www.ti.com
18-Sep-2008
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
TLC5916ID
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IDG4
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IDR
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IDRG4
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IN
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC5916INE4
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC5916IPW
ACTIVE
TSSOP
PW
16
90
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IPWG4
ACTIVE
TSSOP
PW
16
90
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IPWR
ACTIVE
TSSOP
PW
16
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5916IPWRG4
ACTIVE
TSSOP
PW
16
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917ID
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IDG4
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IDR
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IDRG4
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IN
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC5917INE4
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
TLC5917IPW
ACTIVE
TSSOP
PW
16
90
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IPWG4
ACTIVE
TSSOP
PW
16
90
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IPWR
ACTIVE
TSSOP
PW
16
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TLC5917IPWRG4
ACTIVE
TSSOP
PW
16
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
Lead/Ball Finish
MSL Peak Temp (3)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
18-Sep-2008
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF TLC5916, TLC5917 :
• Automotive: TLC5916-Q1, TLC5917-Q1
NOTE: Qualified Version Definitions:
• Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
19-Mar-2008
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
Diameter Width
(mm) W1 (mm)
A0 (mm)
B0 (mm)
K0 (mm)
P1
(mm)
W
Pin1
(mm) Quadrant
10.3
2.1
8.0
16.0
Q1
TLC5916IDR
SOIC
D
16
2500
330.0
16.4
6.5
TLC5916IPWR
TSSOP
PW
16
2000
330.0
12.4
7.0
5.6
1.6
8.0
12.0
Q1
TLC5917IDR
SOIC
D
16
2500
330.0
16.4
6.5
10.3
2.1
8.0
16.0
Q1
TLC5917IPWR
TSSOP
PW
16
2000
330.0
12.4
7.0
5.6
1.6
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
19-Mar-2008
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
TLC5916IDR
SOIC
D
16
2500
333.2
345.9
28.6
TLC5916IPWR
TSSOP
PW
16
2000
346.0
346.0
29.0
TLC5917IDR
SOIC
D
16
2500
333.2
345.9
28.6
TLC5917IPWR
TSSOP
PW
16
2000
346.0
346.0
29.0
Pack Materials-Page 2
MECHANICAL DATA
MTSS001C – JANUARY 1995 – REVISED FEBRUARY 1999
PW (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
14 PINS SHOWN
0,30
0,19
0,65
14
0,10 M
8
0,15 NOM
4,50
4,30
6,60
6,20
Gage Plane
0,25
1
7
0°– 8°
A
0,75
0,50
Seating Plane
0,15
0,05
1,20 MAX
PINS **
0,10
8
14
16
20
24
28
A MAX
3,10
5,10
5,10
6,60
7,90
9,80
A MIN
2,90
4,90
4,90
6,40
7,70
9,60
DIM
4040064/F 01/97
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0,15.
Falls within JEDEC MO-153
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Amplifiers
Data Converters
DLP® Products
DSP
Clocks and Timers
Interface
Logic
Power Mgmt
Microcontrollers
RFID
RF/IF and ZigBee® Solutions
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
dsp.ti.com
www.ti.com/clocks
interface.ti.com
logic.ti.com
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/lprf
Applications
Audio
Automotive
Broadband
Digital Control
Medical
Military
Optical Networking
Security
Telephony
Video & Imaging
Wireless
www.ti.com/audio
www.ti.com/automotive
www.ti.com/broadband
www.ti.com/digitalcontrol
www.ti.com/medical
www.ti.com/military
www.ti.com/opticalnetwork
www.ti.com/security
www.ti.com/telephony
www.ti.com/video
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265