ETC COM117T

C O M 117T
(COTS) COMMERCIAL OFF-THE-SHELF 1.5 AMP POSITIVE
ADJUSTABLE VOLTAGE REGULATOR IN TO-257 PA C K A G E
Three Terminal, Precision Adjustable
Positive Voltage Regulator In TO-257 Package
FEATURES
• Built In Thermal Overload Protection
• Short Circuit Current Limiting
DESCRIPTION
These three terminal positive regulators are supplied in hermetically sealed packages.
All protective features are designed into the circuit, including thermal shutdown,
current-limiting, and safe-area control. With heat sinking, these devices can deliver up
to 1.5 amps of output current. The unit also features output voltages that can be fixed
from 1.2 volts to 37 volts using external resistors.
ABSOLUTE MAXIMUM RATINGS Tc @
25°C
Power Dissipation
TO-257............................. ...........................
. 20 W
Input - Output Voltage Differential.................................... 40
V Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to +
150°C
Lead Temperature (Soldering 10 seconds) . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . .
300°C Thermal Resistance, Junction to Case:. . . . . . . .. . . . . . . . . . . . . . . . . . . . . . .
. . . . .4.2°C/W
Maximum Output Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.1.5 A
Recommended Operating Conditions:
Output Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 to 37 VDC
Ambient Operating Temperature Range (TA ). . . . . . . . . . . .. . . - 55°C to + 125°C
Input Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 to 41.25 VDC
3.3 - 1
3.3
C O M 117T
ELECTRICAL CHARACTERISTICS
-55°C
TA
125°C, IL = 8mA (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Reference Voltage
V REF
V DIFF = 3.0V, TA = 25°C
•
•
V DIFF = 3.3V
V DIFF = 40V
Line Regulation
R LINE
3.0V
R LOAD
V DIFF = 3.0V, 10mA
(Note 1)
VDIFF
3.3V
Load Regulation
(Note 1)
40V, Vout = Vref,TA = 25°C
VDIFF
1.5A, TA = 25°C
V DIFF = 3.3V, 10mA
V DIFF = 40V, 10mA
IL
V DIFF = 40V, 10mA
Thermal Regulation
V RTH
•
40V, Vout = Vref
IL
IL
•
1.5A
300mA, TA = 25°C
IL
•
195mA
V in = 14.6V, IL = 1.5A
Max.
1.20
1.30
1.20
1.30
1.20
1.30
-9
9
-23
23
-15
15
-15
15
-15
15
-15
15
-16
16
Unit
V
mV
mV
mV
P d = 20 Watts, t = 20 ms, TA =25°C
Ripple Rejection
•
RN
f = 120 Hz, Vout = Vref
IAdj
V DIFF = 3.0V, TA = 25°C
(Note 2)
dB
C Adj = 10 µF
Adjustment Pin Current
100
•
•
V DIFF = 3.3V
V DIFF = 40V
Adjustment Pin
I
³Adj
V DIFF = 3.0V, 10mA
Current Change
IL
1.5A, TA = 25°C
V DIFF = 3.3V, 10mA
V DIFF = 40V, 10mA
IL
V DIFF = 40V, 10mA
3.0V
VDIFF
3.3V
Miminum Load Current
ILmin
IL
1.5A
300mA, TA = 25°C
IL
195mA
40V
ICL
V DIFF = 15V
V DIFF = 40V, TA = 25°C
(Note 2)
µA
100
-5
5
-5
5
-5
5
-5
5
-5
5
•
-5
5
V DIFF = 3.0V, VO U T = 1.4V (forced)
V DIFF = 40V, VO U T = 1.4V (forced)
Current Limit
100
•
•
•
40V, TA = 25°C
V DIFF
V DIFF = 3.3V, VO U T = 1.4V (forced)
3.3
66
µA
5.0
•
•
•
5.0
mA
5.0
1.5
3.5
0.18
1.5
A
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. If not tested, shall be guaranteed to the specified limits.
3. The •denotes the specifications which apply over the full operating temperature range.
MECHANICAL OUTLINE
TO-257AA
PIN CONNECTION
.200
.190
.420
.410
.045
.035
Front View
Pin 1: Adjust
Pin 2: Output
Pin 3: Input
Tab:
Isolated
.665
.645
.150
.140
.537
.527
.430
.410
.038 MAX.
.750
.500
.005
1 2 3
.035
.025
.100 TYP.
.120 TYP.
205 Crawford Street, Leominster, MA 01453 USA (978) 534-5776 FAX (978) 537-4246