FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Adjustable Output Voltage
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
Electrically Similar To Industry Standard Type LM117HV
DESCRIPTION
This three terminal positive regulator is supplied in a hermetically sealed surface
mount package. All protective features are designed into the circuit, including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
1.0 amp of output current. This unit features output voltages that can be trimmed
using external resistors, from 1.2 volts to 57 volts.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Power Dissipation (Pd) (Internally Limited). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 W
Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Lead Temperature (Soldering 10 Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280°C
Thermal Resistance: Junction-to-Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12°C/W
MECHANICAL OUTLINE
.090
MAX.
.450
SQ.
.02 x 45°
.300
4 PLCS.
.035
4
PIN 1
PIN 28
1
26
TOP
4 11 R0
.05 X 45°
MAX. 3 PLCS.
SIDE
.009 R. BOTTOM
28 PLCS.
3.5 - 107
.050
24 PLCS.
12
.305
SQ.
18
Pin Connection
Pin 1, 15 thru 28:
IN
Pin 2, 3, 13, and 14: ADJ
Pin 4 thru 12:
OUT
3.5
OM7620SM
ELECTRICAL CHARACTERISTICS
-55°C ≤ TA ≤ 125°C, IL = 8mA (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Reference Voltage
VREF
VDIFF = 3.0V, TA = 25°C
1.20
1.30
Line Regulation
RLINE
(Note 1)
VDIFF = 3.3V
•
1.20
1.30
VDIFF = 40V
•
1.20
1.30
VDIFF = 60V
•
1.20
1.30
-12
12
-25
25
-8
8
3.0V ≤ VDIFF ≤ 40V, VOUT = Vref, TA = 25°C
3.3V ≤ VDIFF ≤ 40V, VOUT = Vref
•
40V ≤ VDIFF ≤ 60V, VOUT = Vref, TA = 25°C
40V ≤ VDIFF ≤ 60V, VOUT = Vref
Load Regulation
RLOAD
(Note 1)
•
VDIFF = 3.0V, 10mA ≤ IL ≤ 1.0A, TA = 25°C
VDIFF = 3.3V, 10mA ≤ IL ≤ 1.0A
•
VDIFF = 40V, 10mA ≤ IL ≤ 300mA, TA = 25°C
Thermal Regulation
VRTH
Ripple Rejection
RN
(Note 2)
Adjustment Pin Current
Adjustment Pin
•
-20
20
•
-20
20
-16
16
VIN = 14.6V, IL = 1.0A
Pd = 20 Watts, t = 20 ms, TA = 25°C
f = 120 Hz, VOUT = Vref
•
IAdj
66
∆IAdj
VDIFF = 3.0V, TA = 25°C
ILmin
ICL
mV
mV
mV
100
•
100
VDIFF = 40V
•
100
VDIFF = 60V
•
VDIFF = 3.0V, 10mA ≤ IL ≤ 1.0A, TA = 25°C
VDIFF = 3.3V, 10mA ≤ IL ≤ 1.0A
V
dB
VDIFF = 3.3V
•
•
3.0V ≤ VDIFF ≤ 40V, TA = 25°C
3.5
20
20
VDIFF = 60V, 10mA ≤ IL ≤ 30mA
VDIFF = 40V, 10mA ≤ IL ≤ 195mA
(Note 2)
-20
-20
VDIFF = 40V, 10mA ≤ IL ≤ 195mA
VDIFF = 40V, 10mA ≤ IL ≤ 300mA, TA = 25°C
Current Limit
12
20
CAdj = 10 µF, IOUT = 100 mA
Current Change
Miminum Load Current
-12
-20
Unit
µA
100
-10
10
-10
10
-10
10
-10
10
-10
10
3.3V ≤ VDIFF ≤ 40V
•
-10
10
3.3V ≤ VDIFF ≤ 60V
•
-10
10
VDIFF = 3.0V, VOUT = 1.4V (forced)
µA
10
VDIFF = 3.3V, VOUT = 1.4V (forced)
•
10
VDIFF = 40V, VOUT = 1.4V (forced)
•
10
VDIFF = 60V, VOUT = 1.4V (forced)
•
mA
10
VDIFF = 40V, TA = 25°C
0.3
1.0
VDIFF = 60V, TA = 25°C
0.05
0.40
A
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. If not tested, shall be guaranteed to the specified limits.
3. The • denotes the specifications which apply over the full operating temperature range.