ETC OM7915SM

OM7905SM
OM7912SM
OM7915SM
SURFACE MOUNT NEGATIVE FIXED
VOLTAGE REGULATOR
Three Terminal, Fixed Voltage, 1.0 Amp
Precision Negative Regulator In A Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally to ±2%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
DESCRIPTION
This three terminal negative regulator is supplied in a hermetically sealed surface
mount package. All protective features are designed into the circuit, including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
1.0 amp of output current. This unit features internally trimmed voltages to ±2% of
nominal voltage. Standard voltages are -5V, -12V and -15V. These units are ideally
suited for Military applications where a hermetic surface mount package is required.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Power Dissipation (Pd) (Internally Limited). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 W
Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Lead Temperature (Soldering 10 Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280°C
Thermal Resistance: Junction-to-Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18°C/W
MECHANICAL OUTLINE
.090
MAX.
.450
SQ.
.02 x 45°
.300
4 PLCS.
.035
4
PIN 1
PIN 28
1
26
TOP
4 11 R0
.05 X 45°
MAX. 3 PLCS.
SIDE
.009 R. BOTTOM
28 PLCS.
3.5 - 157
.050
24 PLCS.
12
.305
SQ.
18
Pin Connection
Pin 1, 15 thru 28:
OUT
Pin 2, 3, 13, and 14: GND
Pin 4 thru 12:
IN
3.5
OM7905SM OM79012SM OM79015SM
ELECTRICAL CHARACTERISTICS
Parameter
Output Voltage, VOUT
Part Number
OM7905SM
OM7912SM
OM7915SM
Line Regulation, VRLINE
(Note 1)
IO = 500mA, -55°C ≤TA ≤ 125°C (unless otherwise specified.)
OM7905SM: VIN = -10V; OM7912SM: VIN = -19V; OM7915SM: VIN = -23V.
Conditions
VIN = -7.5V to -20V
VIN = -14.5V to -27V
VIN = -17.5V to -30V
VIN = -7.5V to -20V
OM7905SM
VIN = -8.0V to -12V
VIN = -14.5V to -27V
OM7912SM
VIN = -16V to -22V
VIN = -17.5V to -30V
OM7915SM
VIN = -20V to -26V
Load Regulation, VRLOAD
(Note 1)
IO = -5mA to -1.0Amp
OM7905SM
IO = -250mA to -750mA
IO = -5mA to -1.0Amp
OM7912SM
IO = -250mA to -750mA
IO = -5mA to -1.0Amp
OM7915SM
IO = -250mA to -750mA
Standby Current Drain, ISCD
OM7905SM
Standby Current Drain Change
With Load, ∆ISCD (Load)
Dropout Voltage
Peak Output Current, IO (pk)
Short Circuit Current, IDS
(Note 2)
Ripple Rejection
VIN = -7.0V to -20V
VIN = -14.5V to -27V
VIN = -17.5V to -30V
3.5
RMS Output Noise, NO (Note 3)
Long Term Stability (Note 3)
∆VIN
∆t
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Units
V
V
V
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
mA
mA
mA
mA
mA
mA
•
0.6
mA
∆VOUT = 100mV, IO = 1.0A
•
2.5
V
2.0
1.0
2.0
A
A
A
dB
dB
dB
dB
dB
dB
µV/V rms
mV
mV
mV
TA = 25°C
VIN = -35V
OM7905SM
f = 120Hz, ∆VIN = -10V
OM7912SM
f = 120Hz, ∆VIN = 10V
OM7915SM
f = 120Hz, ∆VIN = 10V
TA = 25°C, f = 10Hz to 100kHz
OM7905SM
OM7912SM
OM7915SM
Max.
-4.85
-11.64
-14.55
20
35
12
20
33
80
24
70
41
82
36
60
35
50
25
45
55
70
26
55
60
110
34
70
3.0
3.5
4.2
4.6
7.2
8.0
0.6
1.0
1.0
IO = 5mA to 1000mA
∆VIN
∆VOUT
•
•
OM7915SM
OM7905SM
OM7912SM
OM7915SM
Min.
-5.15
-12.36
-15.45
•
OM7912SM
Standby Current Drain Change
With Line, ∆ISCD (Line)
•
•
•
TA = 25°C, t = 1000 hrs.
.70
•
•
•
•
63
60
56
53
53
50
40
75
120
150
Note 1: Load and line regulation are specified at a constant junction temperature. Pulse testing with low
duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
Note 2: Short Circuit protection is only assured up to VIN = -35V.
Note 3: If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range. If not noted TA = 25°C