Phase Control Thyristor CS 1250 ITRMS = 3000 A ITAVM = 1250 A VRRM = 1200 - 1600 V V RSM V RRM V DSM V DRM V V Type 1 3 2 2 4 3 4 1200 1400 1600 1200 1400 1600 CS 1250 - 12io1 CS 1250 - 14io1 CS 1250 - 16io1 1 Symbol Test Conditions I TRMS I TAVM TC = 83°C; 180° sine I TSM ∫i2dt (di/dt)cr TVJ = 45°C; VR = 0 Maximum Ratings t = 10 ms (50 Hz), sine t = 8.3 ms (60 Hz), sine 3000 1250 A A 23000 25000 A A A A 2645000 2594000 A2s A2 s ● 2205000 2195000 A2s A2 s 320 A/µs t = 10 ms (50 Hz), sine t = 8.3 ms (60 Hz), sine 21000 23000 TVJ = 45°C VR = 0 t = 10 ms (50 Hz), sine t = 8.3 ms (60 Hz), sine TVJ = TVJM VR = 0 t = 10 ms (50 Hz), sine t = 8.3 ms (60 Hz), sine (dv/dt) cr TVJ = TVJM; VDR = 2/3 VDRM RGK = ∞; method 1 (linear voltage rise) P GM TVJ = TVJM IT = ITAVM tP = 30 µs tP = 500 µs tP = 10 ms 1000 V/µs ● ● V RGM 5 V T VJ T VJM Tstg -40...+125 125 -40...+ 50 °C °C °C 24.0 .. 28.0 kN Weight ● ● W W W Mounting force ● Thyristor for line frequency International standard package Long-term stability of blocking voltages Gate and auxiliary cathode pin connection Amplifying gate Typical Applications 120 60 16 Md ● ● TVJ = TVJM VR = 0 TVJ = TVJM repetitive, IT = 2500 A f = 5 Hz, tP =200 ms VD = 1/2 VDRM IG = 2 A diG/dt = 2 A/µs Features 600 DC Motor control Power converter AC power controller g Data according to DIN/IEC 747-6 IXYS reserves the right to change limits, test conditions and dimensions ©1996 IXYS Corporation. All rights reserved. IXYS Corporation 3540 Bassett Street, Santa Clara CA 95054 Phone: (408) 982-0700 Fax: 408-496-0670 IXYS Semiconductor GmbH Edisonstr. 15, D-68623 Lampertheim, Germany Phone: +49-6206-5030 Fax: +49-6206-503627 CS 1250 Symbol Test Conditions Characteristic Values IR, ID TVJ = T VJM; VR = VRRM; VD = VDRM ≤ 60 VT IT ≤ 1.85 V V T0 rT For power-loss calculations only (TVJ = 125°C) 1.0 0.21 V mΩ V GT VD = 12 V; TVJ = 25°C ≤ 3.0 V I GT VD = 12 V; TVJ = 25°C ≤ 300 mA V GD TVJ = T VJM; VD = 2/3 VDRM ≤ 0.25 V IL TVJ = 25°C; tP = 10 µs IG = 2 A; diG/dt = 2 A/µs ≤ 1.0 A IH TVJ = 25°C; VD = 12 V; RGK = ∞ ≤ 0.3 A tgd TVJ = 25°C; VD = 500 V IG = 2 A; diG/dt = 2 A/µs ≤ 2.5 µs tq TVJ = TVJM; IT = 1250 A, tP = 200 µs; di/dt = -10 A/µstyp. VR = 100 V; dv/dt = 50 V/µs; VD = 2/3 VDRM 150 µs RthJC DC current 0.02 K/W = 3.14 xITAVM ;TVJ = 25°C Dimensions in mm (1 mm = 0.0394") IXYS reserves the right to change limits, test conditions, and dimensions. mA