LEM FA-PV

Current Transducer FA-050 .. 100PV
IPN = 50 .. 100 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
DC current
Primary current
measuring range
IPN (A)
Type
IP (A)
50
100
0 .. ± 70
0 .. ± 130
FA - 050PV
FA - 100PV
FA - 050PV
VOUT
FA - 100PV
IC
Output voltage
@ ± IPN , RL = 10 kΩ, T A = 25°C ± 4
Current consumpution
16 + IPN /1000
VC
Vd
Supply voltage (± 5 %)
R.m.s. voltage for AC isolation test, AC50/60Hz, 1 min
Features
±4
16+IPN /2000
V
mA
± 15
2.5
V
kV
• Hall effect measuring principle
• PC Board Mount Type
• Low power consumption
• Extended measuring range (3 x IPN )
• Galvanic isolation between Primary
and Secondary circuit
• Isolation voltage 2000V
Accuracy-Dynamic performance data
X
ε
L
VOE
VOH
VOT
TCε G
tr
f
Accuracy @ T A = 25°C, @ ± 15V (± 5%)
Linearity (0 .. ± IPN )
Electrical offset voltage, T A = 25°C
Hysteresis offset voltage @ IP = 0,
after an excursion of 1 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (- 1 dB)
< ± 1.5 @IPN
< ± 0.25
± 0.016
< ± 0.012
< ± 0.04
< ± 0.1
<1
DC .. 100
%
%
V
V
mV/°C
%/°C
µs
kHz
Advantages
• Easy Mounting
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external inteference
Applications
• DC motor drives
• Switched Mode Power Supplies
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 10 .. + 70
- 15 .. + 80
25
°C
°C
g
(SMPS)
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
• Battery supplied applications
• Power supplies for welding
applications.
010301/1
www.nanalem.co.jp
FA- 050 .. 100PV
Terminal Pin Identification
UNIT: mm
NANALEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.