Current Transducer FA-050 .. 100PV IPN = 50 .. 100 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary nominal DC current Primary current measuring range IPN (A) Type IP (A) 50 100 0 .. ± 70 0 .. ± 130 FA - 050PV FA - 100PV FA - 050PV VOUT FA - 100PV IC Output voltage @ ± IPN , RL = 10 kΩ, T A = 25°C ± 4 Current consumpution 16 + IPN /1000 VC Vd Supply voltage (± 5 %) R.m.s. voltage for AC isolation test, AC50/60Hz, 1 min Features ±4 16+IPN /2000 V mA ± 15 2.5 V kV • Hall effect measuring principle • PC Board Mount Type • Low power consumption • Extended measuring range (3 x IPN ) • Galvanic isolation between Primary and Secondary circuit • Isolation voltage 2000V Accuracy-Dynamic performance data X ε L VOE VOH VOT TCε G tr f Accuracy @ T A = 25°C, @ ± 15V (± 5%) Linearity (0 .. ± IPN ) Electrical offset voltage, T A = 25°C Hysteresis offset voltage @ IP = 0, after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth (- 1 dB) < ± 1.5 @IPN < ± 0.25 ± 0.016 < ± 0.012 < ± 0.04 < ± 0.1 <1 DC .. 100 % % V V mV/°C %/°C µs kHz Advantages • Easy Mounting • Small size and space saving • Only one design for wide current ratings range • High immunity to external inteference Applications • DC motor drives • Switched Mode Power Supplies General data TA TS m Ambient operating temperature Ambient storage temperature Mass - 10 .. + 70 - 15 .. + 80 25 °C °C g (SMPS) • AC variable speed drives • Uninterruptible Power Supplies (UPS) • Battery supplied applications • Power supplies for welding applications. 010301/1 www.nanalem.co.jp FA- 050 .. 100PV Terminal Pin Identification UNIT: mm NANALEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.