NEC EA2-5TNP

DATA S H E E T
MINIATURE SIGNAL RELAY
EA2 SERIES
COMPACT AND LIGHTWEIGHT
DESCRIPTION
The EA2 series has reduced package size and power consumption to other NEC Conventional relays.
Furthermore, it complies with 1500 V surge-voltage requirement of FCC part 68 by the unique structure and the
efficient magnetic circuit
FEATURES
™ Low power consumption
™ Compact and light weight
™ 2 form c contact arrangement
™ Low magnetic arrangement
™ Breakdown voltage : 1000 Vac (surge voltage 1500 V), FCC Part 68 compliant
™ Tube packaging
™ UL recognized (E73266), CAS certified (LR46266)
APPLICATIONS
Electronic switching systems, PBX, key telephone systems, automatic test equipment and other electronic equipment.
ATTENTION
DO NOT EXCEED MAXIMUM RATINGS.
Do not use relays under exceeding conditions such as over ambient temperature, over voltage and over
current. Incorrect use could result in abnormal heating, damage to related parts or cause burning.
READ CAUTIONS IN THE SELECTION GUIDE.
Read the cautions described in NEC's "Miniature Relays" (ER0046EJ∗) when you choose relays for
your application.
Document No. ER0001EJ6V0DS00 (6th edition)
Date Published June 1999 M
Printed in Japan
©
1989 (1996)
EA2 SERIES
OUTLINE DRAWING AND DIMENSIONS
PAD LAYOUT (bottom view)
Unit : mm (inch)
0.33 (0.013)
7.62
(0.30)
10- φ 0.8(0.03)
(0.36)
2.54
(0.10)
0.5
(0.02)
0.25
(0.01)
10.16
(0.40)
Note. Tolerance +
– 0.1 ( +
– 0.004) unless othewise specified
7.62
3.5
2.54
2.54
(0.10)
9.2 max.
(0.21)
(0.56)
5.4 max.
14.2 max.
(0.10)
(0.30)
Note. tolerance +
– 0.2 ( +
– 0.008) unless otherwise specified
Dimensions in
show basic size.
NJ type : Cover height-6.3 mm (0.248), Leads-2.8 mm (0.11)
MARKINGS
SAFETY STANDARD AND RATING
1
2
UL Recognized
(UL508)∗
File No E73266
CSA Certificated
(CSA C22.2 No 14)
File No LR46266
30 Vdc, 1 A
(Resistive)
110 Vdc, 0.3 A (Resistive)
125 Vdc, 0.5 A (Resistive)
EA2-5
q Part number
JAPAN
5
9106
∗ Spacing : UL114, UL478
w Manufacturer
e Country of origin
3
r Date code
4
t Index mark of relay direction
Standard type
(pin No. 1, 10.)
1
y UL, CSA Marking
2
EA2-5NU
JAPAN
3
9106
5
6
4
UL recognized,
CSA certified type
PIN CONFIGURATIONS
S
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
– +
+
+
–
+
–
RS
–
+ –
10
9
8
7
6
10
9
8
7
6
Index mark of
relay direction
Non-latch type
(not energized position)
Single coil latch type
(reset position)
10
9
8
7
6
R
Double coil latch type
(reset position)
S : Coil polarity of set (operate)
R : Coil polarity of reset (release)
2
DATA SHEET ER0001EJ6V0DS00
EA2 SERIES
PART NUMBER SYSTEM
EA2 – 3 S NU
Nil : Standard type
NU : UL recognized, CSA certified type
NJ : Trimmed leads type ∗
NP : Silver-palladium alloy contact (with gold alloy overlay) ∗
∗ UL recognized, CAS certified type
Latch type
Nil : Non-latch type (standard type)
S : Single coil latch type
T : Double coil latch type
Nominal coil voltage
3, 4.5, 5, 6, 9, 12, 24 Volts
EA2 series
PERFORMANCE CHARACTERISTICS
Contact Form
Contact rating
2 form c
Maximum switching power
30 W (resistive)
62.5 VA (resistive)
Maximum switching voltage
220 Vdc
250 Vac
Maximum switching current
1A
Maximum carrying current
2A
Minimum contact ratings
10 mVdc, 10 µA ∗ 1
Initial contact resistance
50 mΩ typ. (Initial)
Contact material
Silver alloy with gold alloy overlay
Nominal operating Power
Minimum operating Power
Non-latch type and double coil latch type
140 mW (3 to 12 V)
200 mW (24 V)
Single coil Latch type
100 mW (3 to 12 V)
150 mW (24 V)
Non-latch type and double coil latch type
79 mW (3 to 12 V)
113 mW (24 V)
Single coil latch type
56 mW (3 to 12 V)
85 mW (24 V)
Operate time (excluding bounce)
Approximately 2 ms without diode
Release time (excluding bounce)
Approximately 1 ms without diode
Insulation resistance
1000 MΩ at 500 Vdc
Between open contacts
Breakdown voltage
Between adjacent contacts
1000 Vac (for one minute)
1500 V surge (10 × 160 µ s ∗ 2)
Between coil and contact
Shock resistance
735 m / s 2 (75 G) (misoperating)
980 m / s 2 (100 G) (destructive failure)
Vibration resistance
10 to 55 Hz at double amplitude of 3 mm (20 G)
(misoperating)
10 to 55 Hz, at double amplitude of 5 mm (30 G)
(destructive failure)
Ambient temperature
–40°C to 85°C
Coil temperature rise
18 degrees at nominal coil voltage
Noload
1 × 108 operations (Non-latch type) ∗ 3
1 × 107 operations (latch type)
Running specifications
Load
50 Vdc 0.1 A (resistive), 1 × 106 operations at 85˚C, 2 Hz
10 Vdc 10 mA (resistive), 1 × 106 operations at 85˚C, 2 Hz
Weight
Approximately 1.5 grams
∗ 1 This value is a reference value in the resistance load.
Minimum capacity changes depending on seitching frequency and environment temperature and the load.
∗ 2 Rise time : 10 µ s, fall time : 160 µ s
∗ 3 This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of
operation by which a steady characteristic is maintained is 1 × 107 times.
DATA SHEET ER0001EJ6V0DS00
3
EA2 SERIES
PRODUCT LINEUP
Non-latch Type
at 20˚C
Coil
Resistance
(Ω) ±10 %
Nominal Coil
Voltage
(Vdc)
3
Must Operate
Voltage
(Vdc)
64.3
Must Release
Voltage
(Vdc)
2.25
0.3
4.5
145
3.38
0.45
5
178
3.75
0.5
6
257
4.5
0.6
9
579
6.75
0.9
12
1028
9
1.2
24
2880
18
2.4
Single-Coil Latch Type
at 20˚C
Nominal Coil
Voltage
(Vdc)
Coil
Resistance
(Ω) ±10 %
Must Operate
Voltage
(Vdc)
Must Release
Voltage
(Vdc)
90
2.25
2.25
4.5
202.5
3.38
3.38
5
250
3.75
3.75
6
360
4.5
4.5
9
810
6.75
6.75
12
1440
9
9
24
3840
18
18
3
Double-Coil Latch Type ∗∗ (Can not be driven by revese polarity for reverse operation.)
Nominal Coil
Voltage
(Vdc)
3
4.5
5
6
9
12
24
Note
4
Must Operate
Voltage
(Vdc)
Coil
Resistance
(Ω) ±10 %
at 20˚C
Must Release
Voltage
(Vdc)
S
64.3
2.25
–
R
64.3
–
2.25
S
145
3.38
–
R
145
–
3.38
S
178
3.75
–
R
178
–
3.75
S
257
4.5
–
R
257
–
4.5
S
579
6.75
–
R
579
–
6.75
S
1028
R
1028
–
9
S
2880
R
2880
–
18
9
–
18
–
∗ Test by pulse voltage
∗∗ S : Set coil (pin No.1... + , pin No.5... – ) R : Reset coil (pin No.10... + , pin No.6... – )
The latch type relays should be initalized at appointed position before using, and should be enegized to specific
polanity by a bone polabity to avoid wrong operation.
Any special coil requirement, please contact NEC for availability.
DATA SHEET ER0001EJ6V0DS00
EA2 SERIES
TYPICAL PERFORMANCE DATA
SWITCHING CAPACITY
80
DC Load (resistive)
AC Load (resistive)
Coil Temperature Rise (˚C)
Switching Current (A)
2.0
COIL TEMPERATURE RISE
1.0
0.5
0.4
0.3
0.25A
0.136A
0.2
30
100
200
Switching Voltage (V)
60
40
20
0
250 Vdc
220 Vdc
100
200
300
400
Applied Power (mW)
Release Time or
Bounce Time at Release (ms)
OPERATE TIME
Operate Time
2
Bounce Time at Operate
1
0
100
200
300
400
500
RELEASE TIME WITHOUT DIODE
RELEASE TIME WITH DIODE
Release Time or
Bounce Time at Release (ms)
Release Time or
Bounce Time at Release (ms)
Applied Power (mW)
2
Release Time
1
Bounce Time at Release
100
0
200
300
400
500
Release Time
2
1
0
Bounce Time at Release
100
200
300
400
500
Applied Power (mW)
Applied Power (mW)
RUNNING SPECIFICATIONS (Noload)
Temperature : 85˚C
Drive : 5 Vdc, 10 Hz 50% duty
Operate Voltage or
Release Voltage (V)
5
Contact Resistance (mΩ)
Sample : EA2-5 n = 10
Load : None
Operate Voltage
Release Voltage
4
3
2
1
0
1
5
10
2
3
Number of Operations ( × 10 6 operations)
1000
Make contact
Break contact
500
300
200
100
50
30
20
10
0
DATA SHEET ER0001EJ6V0DS00
1
2
3
5
10
Number of Operations ( × 10 6 operations)
5
EA2 SERIES
50
40
30
20
10
Max.
0
–10
–20
–30
–40
–50
Min.
I
II
III
IV
Layout
V
VI
Drift of Release Voltage (%)
Drift of Operate Voltage (%)
MAGNETIC INTERFERENCE
50
40
30
20
10
0
–10
–20
–30
–40
–50
Max.
Min.
I
II
III
IV
Layout
V
VI
2.54
ON
Layout
I
OFF
OFF
ON
OFF
ON
OFF
Layout
II
Layout
III
ON
OFF
ON
OFF
ON
OFF
Layout
IV
2.54
ON
Sample
Layout VI
Layout V
Mounting Layout (mm)
PACKAGE
Dimensions of Relay Tube (Unit : mm)
40 pieces / Tube
Material : Polyvinyl chloride
(auti-static treated)
586 +
–1
12.0 +
– 0.3
(4.6)
(0.5 t)
(6.2)
(2.5)
13.7 +
– 0.3
( ) Reference
(4.5)
Outline of Package
Rubber stopper (Red)
Rubber stopper (Green)
Index Mark
6
DATA SHEET ER0001EJ6V0DS00
EA2 SERIES
GUIDE TO APPLICATIONS
1. When connecting coils, refer to the pin configuration to prevent misoperation or malfunction.
2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should
be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state.
3. Soldering should be done at 250˚C within 10 sec.
4. Ultrasonic cleaning is not recommended to keep reliable contact performance. Alcohol-based solvents are
available as proper solvents.
5. Pressurized stress on the relay cover is not favorable to keep reliable operation of the relay during operation.
6. Minimum contact load of the relay is 10 mV, 10 µ A.
This value is a reference value in the resistance load.
Minimum capacity changes depending on swiching frequency and environment temperature and the load.
DATA SHEET ER0001EJ6V0DS00
7
EA2 SERIES
No part of this document may be copied or reproduced in any form or by any means without the prior
written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which
may appear in this document.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other
liability arising from use of such device. No license, either express, implied or otherwise, is granted
under any patents, copyrights or other intellectual property rights of NEC Corporation or others.
While NEC Corporation has been making continuous effort to enhance the reliability of its electronic
components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or
injury to persons or property arising from a defect in an NEC electronic component, customers must
incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and antifailure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based
on a customer designated "quality assurance program" for a specific application. The recommended
applications of a device depend on its quality grade, as indicated below. Customers must check the
quality grade of each device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
Anti-radioactive design is not implemented in this product.