OMRON G5V-2

PCB Relay
G5V-2
Miniature Relay for Signal Circuits
■
■
■
■
■
Wide switching power of 10 µA to 2 A.
High dielectric strength coil-contacts:1,000 VAC;
open contacts: 750 VAC.
Conforms to FCC Part 68 requirements.
Ag + Au clad bifurcated crossbar contacts and
fully sealed for high contact reliability.
New 150-mW relays with high-sensitivity.
RoHS Compliant
Refer to pages 16 to 17 for details.
RC FCC
Ordering Information
Classification
Contact form
Standard
DPDT
Contact type
Bifurcated crossbar
Contact material
Ag + Au-Alloy
Enclosure ratings
Fully sealed
Model
G5V-2
High-sensitivity
G5V-2-H1
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 12 VDC
Rated coil voltage
Model Number Legend
G5V -
1
VDC
2
3
2. Classification
H1: High-sensitivity
1. Contact Form
2: DPDT
3. Rated Coil Voltage
3, 5, 6, 9, 12, 24, 48 VDC
Specifications
■
Coil Ratings
Standard Models
Rated voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
Rated current
166.7 mA
100 mA
83.3 mA
55.6 mA
41.7 mA
20.8 mA
12 mA
18 Ω
50 Ω
72 Ω
162 Ω
288 Ω
1,152 Ω
4,000 Ω
Armature OFF
0.04
0.09
0.16
0.31
0.47
1.98
7.23
Armature ON
0.05
0.11
0.19
0.49
0.74
2.63
10.00
Coil resistance
Coil inductance
(H) (ref. value)
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
120% of rated voltage at 23°C
Power consumption
Approx. 500 mW
Note:
Approx.
580 mW
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
105
G5V-2
G5V-2
High Sensitivity Models
Rated voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
Rated current
50 mA
30 mA
25 mA
16.7 mA
12.5 mA
8.33 mA
6.25 mA
Coil resistance
60 Ω
166.7 Ω
240 Ω
540 Ω
960 Ω
2,880 Ω
7,680 Ω
Armature ON
0.18
0.46
0.70
1.67
2.90
6.72
20.1
Armature OFF
0.57
0.71
0.97
2.33
3.99
9.27
26.7
Coil inductance
(H) (ref. value)
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
180% of rated voltage at 23°C
Power consumption
Approx. 150 mW
Note:
■
150% of rated
voltage at
23°C
Approx.
200 mW
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Contact Ratings
Item
Standard models
Load
Resistive load (cosφ = 1)
Rated load
0.5 A at 125 VAC; 2 A at 30 VDC
Contact material
Ag + Au-clad
Rated carry current
2A
Max. switching voltage
125 VAC, 125 VDC
High sensitivity models
0.5 A at 125 VAC; 1 A at 24 VDC
Max. switching current
2A
1A
Max. switching power
62.5 VA, 60 W
62.5 VA, 24 W
Failure rate (reference value)
(See note.)
0.01 mA at 10 mVDC
Note:
■
Approx.
300 mW
P level: λ60 = 0.1 x 10–6/operation
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value
may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
Characteristics
Item
Standard models
High sensitivity models
Contact resistance (See note 1.)
50 mΩ max.
100 mΩ max.
Operate time
7 ms max.
Release time
3 ms max.
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance (See note 2.)
1,000 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts
of same polarity
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Impulse withstand voltage
1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 (approx. 20G)
Endurance
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Operating: −25°C to 65°C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 5 g
Note:
Note:
106
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Operating: −25°C to 70°C (with no icing)
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength.
G5V-2
■
G5V-2
Approved Standards
UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928)
Contact form
Coil ratings
Contact ratings
G5V-2
DPDT
3 to 48 VDC
G5V-2-H1
0.5 A, 125 VAC (general use)
0.2 A, 110 VDC (resistive load)
1 A, 24 VDC (resistive load)
0.6 A, 125 VAC (general use)
0.6 A, 110 VDC (resistive load)
2 A, 30 VDC (resistive load)
Engineering Data
Maximum Switching Power
Endurance
G5V-2
G5V-2
Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
AC resistive load
DC
resistive
load
Endurance (x10 3 operations)
Switching current (A)
G5V-2
30-VDC
resistive
load
125-VAC resistive
load
1
Switching voltage (V)
2
3
Ambient temperature (°)
G5V-2-H1
G5V-2-H1
0.7
0.5
DC resistive load
0.2
0.1
0
Switching voltage (V)
500
200
24-VDC resistive load
300
100
125-VAC resistive load
50
30
10
Maximum coil voltage (%)
1
Life expectancy (x10 3 operations)
Switching current (A)
AC resistive
load
0.3
The maximum coil voltage refers to the
maxi-mum value in a varying range of
operating power voltage, not a continuous
voltage.
1000
5
3
48 VDC
Switching current (A)
Note:
G5V-2-H1
Coil rated voltage
3 to 24 VDC
3 to 24 VDC
180
160
140
48 VDC
120
100
80
0
Switching current (A)
Ambient temperature (°)
Note:
The maximum coil voltage refers to the
maxi-mum value in a varying range of
operating power voltage, not a continuous
voltage.
107
G5V-2
G5V-2
Dimensions
Note:
1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
Terminal Arrangement/
Internal Connections
(Bottom View)
1
8
4
6
13
11
Mounting Holes
(Bottom View)
Tolerance: ±0.1
(1.3)
7.62
5.08 5.08
(1.2)
10.1 max.
9.9 typ.
20.5 max.
20.3 typ.
7.62
16
11.5 max.
11.4 typ.
9
(1.3)
Eight, 1-dia. holes
0.5
0.5
0.3
7.62
3.5
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable
contacts because the heat generated by the coil itself will affect
the insulation, causing a film to develop on the contact surfaces.
Be sure to use a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep the
solvent temperature to less than 40°C. Do not put the Relay in a
cold cleaning bath immediately after soldering.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K046-E1-03
108