NEC EC2-12T

DATA S H E E T
MINIATURE SIGNAL RELAY
EC2 SERIES
COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE,
HIGH BREAKDOWN VOLTAGE
DESCRIPTION
The EC2 series has reduced mounting space but sustained high-performance of NEC EA2 series. Furthermore,
it complies with 2500 V surge-voltage requirement of Bellcore specification.
FEATURES
™ Compact and light weight
™ 2 form c contact arrangement
™ Low power consumption
™ Reduced mounting space : 15 mm × 7.5 mm
™ High-breakdown voltage of coil to contacts :
1500 Vac, 2500 V (rise time : 2 µs, fall time : 10 µs)
™ Capable of High-power switching :
700 Vac, 4.2 A, 4 times in case of accident
™ UL recognized (E73266), CAS certified (LR46266)
APPLICATIONS
Electronic switching systems, PBX, terminal equipment, telephone systems.
For Right Use of Miniature Relays
DO NOT EXCEED MAXIMUM RATINGS.
Do not use relays under exceeding conditions such as over ambient temperature, over voltage
and over current. Incorrect use could result in abnormal heating, damage to related parts or
cause burning.
READ CAUTIONS IN THE SELECTION GUIDE.
Read the cautions described in NEC's "Miniature Relays" (ER0046EJ∗) when you choose relays
for your application.
Document No. ER0002EJ4V0DS00 (4th edition)
Date Published June 1999 M
Printed in Japan
©
1994(1996)
EC2 SERIES
PAD LAYOUT (bottom view)
9.4(0.37) MAX.
0.25
(0.01)
3.2
(0.13)
0.5
(0.02)
5.08 2.54 2.54 2.54
(0.20)(0.10)(0.10)(0.10)
2.54
(0.10)
Note. General tolerance : +
– 0.2 ( +
– 0.008)
Dimensions in
show basic size.
NJ type : Leads-2.8 mm (0.11)
5 × 2.54 (0.1)
Note. General tolerance : +
– 0.1 ( +
– 0.004)
MARKINGS
SAFETY STANDARD AND RATING
UL Recognized
(UL508)∗
File No E73266
CSA Certificated
(CSA C22.2 No 14)
File No LR46266
30 Vdc, 2A
(Resistive)
110 Vdc, 0.3A (Resistive)
125 Vdc, 0.5A (Resistive)
Standard type
1
2
10- φ 0.8 (0.31)
2.54
(0.10)
4 × 2.54 (0.1)
5.08
(0.20)
Double coil latch
2 × 2.54(0.1)
8- φ 0.8 (0.31)
7.5 (0.30) MAX.
15.0 (0.59) MAX.
2.54(0.1)
Non-latch and Single coil latch
EC2-5
∗ Spacing : UL114, UL478
JAPAN
5
9206
q Part number
3
(pin No. 1, 12)
TUV Certificate
(EN60255 / IEC60255)
No. R 9751153
(Nonlatch and Single-coil-latch)
Creepage and clearance of
coil to contact is more than 2 mm.
(According EN60950)
y UL, CSA Marking
Basic insulation class
w Manufacturer
4
e Country of origin
r Date code
UL recognized,
t Index mark of relay direction
CSA certified type
1
2
5
EC2-5NU
JAPAN
6
9206
3
4
PIN CONFIGURATIONS (bottom view)
1
3
4
5
1
3
4
5
R S
Index mark of
relay direction
12
10
9
8
Non-latch type
(not energized position)
3
4
5
6
S
12
10
9
8
Single coil latch type
(reset position)
S : Coil polarity of set (operate)
R : Coil polarity of reset (release)
2
1
DATA SHEET ER0002EJ4V0DS00
R
12
10
9
8
7
Double coil latch type
(reset position)
2 × 2.54(0.1)
Unit : mm (inch)
2.54(0.1)
OUTLINE DRAWING AND DIMENSIONS
EC2 SERIES
PART NUMBER SYSTEM
E C 2 – 9 S NU
Nil : Standard type
NU : UL recognized, CSA certified type
NJ : Trimed leads type ∗
NP : Silver-palladium alloy contact (with gold alloy overlay) ∗
∗ UL recognized, CSA certified type
Latch type
Nil : Non-latch type
S : Single coil latch type
T : Double coil latch type
Nominal coil voltage
3, 4.5, 5, 6, 9, 12, 24 V
EC2 series
PERFORMANCE CHARACTERISTICS
Contact Form
2 Form c
Contact Material
Silver alloy with gold alloy overlay
Contact Ratings
(UL / CSA Rating)
Maximum Switching Power
60 W, 125 VA
Maximum Switching Voltage
220 Vdc, 250 Vac
Maximum Switching Current
2A
Maximum Carrying Current
2A
Minimum Contact Ratings
10 mVdc, 10 µA ∗1
Initial Contact Resistance
50 mΩ typ. (Initial)
Nominal Operating Power
Non-Latch Type
140 mW (3 to 12 V), 200 mW (24 V)
Single Coil Latch Type
100 mW
Single Coil Latch Type
140 mW
Operate Time (Excluding Bounce)
Approx. 2 ms
Release Time (Excluding Bounce)
Approx. 1 ms without diode
Insulation Resistance
1000 MΩ at 500 Vdc
Between Open Contacts
Breakdown Voltage
Between Adjacent Contacts
Between Coil and Contact
1000 Vac (for one minute)
1500 V surge (10 × 160 µ s ∗2)
1500 Vac (for one minute)
2500 V surge, (2 × 10 µs ∗3)
Double Coil 1000 Vac (for one minute)
Latch type 1500 V surge (10 × 160 µ s ∗2)
Shock Resistance
735 m / s 2 (75 G) (misoperating)
980 m / s 2 (100 G) (destructive failure)
Vibration Resistance
10 to 55 Hz double amplitude of 3 mm (20 G) (misoperating)
10 to 55 Hz, double amplitude of 5 mm (30 G) (Destructive failure)
Ambient Temperature
–40 to 85˚C
Coil Temperature Rise
18 degrees at nominal coil voltage (140 mW)
No-load
Running specifications
Weight
Load
1 × 108 ∗4 operations (Non-latch type) 1 × 107 operations (latch type)
50 Vdc, 0.1 A (resistive) 1 × 106 operations at 85˚C, 2 Hz
10 Vdc, 10 mA (resistive) 1 × 106 operations at 85˚C, 2 Hz
Approx. 1.9 g
∗1 This value is reference value in the resistance load.
Minimum capacity changes depending on switching frequency and environment temperatur and the load.
∗2 rise time : 10 µ s, fall time : 160 µ s
∗3 rise time : 2 µ s, fall time : 10 µ s
∗4 This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of operation
by whicha steady characteristic is maintained is 1 × 107 times.
DATA SHEET ER0002EJ4V0DS00
3
EC2 SERIES
PRODUCT LINEUP
Non-latch Type
at 20˚C
Coil
Resistance
(Ω) ±10 %
Nominal Coil
Voltage
(Vdc)
3
Must Operate
Voltage
(Vdc)
64.3
Must Release
Voltage
(Vdc)
2.25
0.3
4.5
145
3.38
0.45
5
178
3.75
0.5
6
257
4.5
0.6
9
579
6.75
0.9
12
1028
9
1.2
24
2880
18
2.4
Single-Coil Latch Type
at 20˚C
Nominal Coil
Voltage
(Vdc)
Coil
Resistance
(Ω) ±10 %
Must Operate
Voltage
(Vdc)
Must Release
Voltage
(Vdc)
90
2.25
2.25
4.5
202.5
3.38
3.38
5
250
3.75
3.75
6
360
4.5
4.5
9
810
6.75
6.75
12
1440
9
9
24
5760
18
18
3
Double-Coil Latch Type ∗∗ (Can not be driven by revese polarity for reverse operation.)
Nominal Coil
Voltage
(Vdc)
3
4.5
5
6
9
12
24
Note
4
Must Operate
Voltage
(Vdc)
Coil
Resistance
(Ω) ±10 %
at 20˚C
Must Release
Voltage
(Vdc)
S
64.3
2.25
–
R
64.3
–
2.25
S
145
3.38
–
R
145
–
3.38
S
178
3.75
–
R
178
–
3.75
S
257
4.5
–
R
257
–
4.5
S
579
6.75
–
R
579
–
6.75
S
1028
R
1028
–
9
S
4114
R
4114
–
18
9
–
18
–
∗ Test by pulse voltage
∗∗ S : Set coil (pin No.1... + , pin No.5... – ) R : Reset coil (pin No.10... + , pin No.6... – )
The latch type relays should be initalized at appointed position before using, and should be enegized to specific
polanity by a bone polabity to avoid wrong operation.
Any special coil requirement, please contact NEC for availability.
DATA SHEET ER0002EJ4V0DS00
EC2 SERIES
TYPICAL PERFORMANCE DATA
SWITCHING CAPACITY
1
0.5
0.4
0.3
50
Coil Temperarure Rise (˚C)
DC Load (resistive)
AC Load (resistive)
2
Switching Current (A)
COIL TEMPERATURE RISE
0.273 A
0.2
40
30
20
10
0
30
100
100
200
300
400
250 V
200
Applied Power (mW)
220 V
Switching Voltage (V)
Operate Time or
Bounce Time at Operate (ms)
OPERATE TIME
Operate Time
3
Bounce Time Operate
2
1
0
100
200
300
400
500
RELEASE TIME WITHOUT DIODE
2
RELEASE TIME WITH DIODE
Release Time
1
Bounce Time at Release
0
100
200
300
400
500
Release Time or
Bounce Time at Release (ms)
Release Time or
Bounce Time at Release (ms)
Applied Power (mW)
3
Release Time
2
Bounce Time at Release
1
0
Applied Power (mW)
100
200
300
400
500
Applied Power (mW)
RUNNING SPECIFICATIONS (Noload)
Sample : EE2-5 n=10
Load : None
1000
Operate Voltage
Release Voltage
Contact Resistance(mΩ)
Operate Voltage or
Release Voltage(V)
5
4
3
2
1
0
1
Temperature : 85˚C
Drive : 5 Vdc, 10 Hz 5% duty
2
3
4
10
6
Number of Operations(x10 operations)
500
Make contact
Break contact
300
200
100
50
30
20
10
0
DATA SHEET ER0002EJ4V0DS00
1
2
3
5
10
6
Number of Operations(x10 operations)
5
EC2 SERIES
BREAKDOWN VOLTAGE
Sample : EC2-5
(a) Between Open Contacts
(n = 10 pcs)
(a) Between Adjacent Contacts
10
Appearance
Appearance
10
5
0
(n = 10 pcs)
0.5
1.0
5
0
1.5
2.0
3.0
2.5
Breakdown voltage (kV)
Breakdown voltage (kV)
(a) Between Coil and Contacts
(n = 25 pcs)
Appearance
10
5
0
1.5
2.5
2.0
Breakdown voltage (kV)
+40
+30
+20
+10
0
–10
–20
–30
–40
Max.
Min.
II
III
IV
V
VI
+40
+30
+20
+10
0
–10
–20
–30
–40
Max.
Min.
I
Layout
ON
ON
Layout
I
OFF
Layout
II
III
IV
V
VI
Layout
ON
OFF
ON
OFF
Layout
III
ON
OFF
ON
OFF
ON
OFF
Layout V
6
OFF
II
2.54
2.54
I
Drift of Release Voltage (%)
Drift of Operate Voltage (%)
MAGNETIC INTERFERENCE
Layout
IV
Sample
Layout VI
DATA SHEET ER0002EJ4V0DS00
Mounting Layout (mm)
EC2 SERIES
PACKAGE
Dimensions of Relay Tube (Unit : mm)
35 pieces / Tube
Material : Polyvinyl chloride
(auti-static treated)
543 +
–1
15.5 +
– 0.3
(4.8)
(0.5 t)
11.9 +
– 0.3
(2.4)
( ) Reference
Outline of Package
Rubber stopper (Red)
Rubber stopper (Green)
Index Mark
GUIDE TO APPLICATIONS
1. When connecting coils, refer to the pin configuration to prevent misoperation or malfunction.
2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should
be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state.
3. Soldering should be done at 250 ˚C within 10 sec.
4. Ultrasonic cleaning is not recommended to keep reliable contact performance. Alcohol based solvents are
available as proper solvents.
5. Minimum contact load of the relay is 10 mV, 10 µ A.
This value is a reference value in the resistance load.
Minimum capacity changes depending on swiching frequency and environment temperature and the load.
DATA SHEET ER0002EJ4V0DS00
7
EC2 SERIES
No part of this document may be copied or reproduced in any form or by any means without the prior
written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which
may appear in this document.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other
liability arising from use of such device. No license, either express, implied or otherwise, is granted
under any patents, copyrights or other intellectual property rights of NEC Corporation or others.
While NEC Corporation has been making continuous effort to enhance the reliability of its electronic
components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or
injury to persons or property arising from a defect in an NEC electronic component, customers must
incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and antifailure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based
on a customer designated "quality assurance program" for a specific application. The recommended
applications of a device depend on its quality grade, as indicated below. Customers must check the
quality grade of each device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
Anti-radioactive design is not implemented in this product.