POWER-ONE IMR25

IMR 25...40 Series
25...40 Watt DC-DC Converters
Input voltage range up to 72 V DC
1, 2 or 3 outputs up to 30 V DC
1500 V DC I/O electric strength test voltage
• Low cost
• Short circuit protection
• Efficiency up to 82%
Selection chart
Output 1
Output 2
Output 3
Uo nom Io nom Uo nom Io nom Uo nom Io nom
[V DC] [A] [V DC] [A] [V DC] [A]
3.3
6.5
3.3
10
5
5
5
8
12
2.1
12
3.5
15
1.7
15
3
24
2
+5
4.7
–5
0.3
+5
8
–5
0.5
+12 1.8
–12 0.3
+12
3
–12 0.5
+15 1.4
–15 0.3
+15
2
–15 0.5
+5
4
+12 0.3
–12 0.3
+5
6
+12 0.5
–12 0.5
+5
3.5
+15 0.3
–15 0.3
+5
6
+15 0.5
–15 0.5
+5
12
–5
0.5
+12 0.5
www.power-one.com
Type
Input voltage
9...18 V DC
12 IMR 25-03-2
12 IMR 40-03-2
12 IMR 25-05-2
12 IMR 40-05-2
12 IMR 25-12-2
12 IMR 40-12-2
12 IMR 25-15-2
12 IMR 40-15-2
12 IMR 40-24-2
12 IMR 25-0505-2
12 IMR 40-0505-2
12 IMR 25-1212-2
12 IMR 40-1212-2
12 IMR 25-1515-2
12 IMR 40-1515-2
12 IMR 25-051212-2
12 IMR 40-051212-2
12 IMR 25-051515-2
12 IMR 40-051515-2
-
Type
Input voltage
18...36 V DC
24 IMR 25-03-2
24 IMR 40-03-2
24 IMR 25-05-2
24 IMR 40-05-2
24 IMR 25-12-2
24 IMR 40-12-2
24 IMR 25-15-2
24 IMR 40-15-2
24 IMR 40-24-2
24 IMR 25-0505-2
24 IMR 40-0505-2
24 IMR 25-1212-2
24 IMR 40-1212-2
24 IMR 25-1515-2
24 IMR 40-1515-2
24 IMR 25-051212-2
24 IMR 40-051212-2
24 IMR 25-051515-2
24 IMR 40-051515-2
24 IMR 40-050512-2
Type
Input voltage
36...72 V DC
48 IMR 25-03-2
48 IMR 40-03-2
48 IMR 25-05-2
48 IMR 40-05-2
48 IMR 25-12-2
48 IMR 40-12-2
48 IMR 25-15-2
48 IMR 40-15-2
48 IMR 40-24-2
48 IMR 25-0505-2
48 IMR 40-0505-2
48 IMR 25-1212-2
48 IMR 40-1212-2
48 IMR 25-1515-2
48 IMR 40-1515-2
48 IMR 25-051212-2
48 IMR 40-051212-2
48 IMR 25-051515-2
48 IMR 40-051515-2
48 IMR 40-050512-2
1
Board Mountable
IMR 25...40 Series
Input
Input voltage
Reverse voltage protection
continuous range, 12 V
continuous range, 24 V
continuous range, 48 V
shunt diode
9...18 V DC
18...36 V DC
36...72 V DC
Output
Output voltage setting accuracy
Minimum load
Line regulation
Load regulation
Output voltage switching noise
Ui nom , lo nom
recommended
Ui min...Ui max, lo nom
Ui nom, 0…100% Io nom, single output models
dual and triple output models (tracking)
Ui nom, 20...100 Io nom , peak-peak, total
±2% Uo nom
20% lo nom
±1% Uo nom
±2% Uo nom
5% Uo nom
max. 2% Uo nom
Control and protection
Overload protection
No-load protection
Ui min , full load
125% Pi nom
Safety and EMC
Electric strength test voltage
Electromagnetic interference
I/O
conducted with external filter
1500 V DC
class B
Ui nom , lo nom
non operational
non condensing
MIL-HDBK-217F, N2
–10...50°C
–25...85°C
95%
2'000'000 h
Environmental
Operating ambient temperature
Storage temperature
Relative humidity
MTBF
www.power-one.com
2
IMR 25...40 Series
25...40 Watt DC-DC Converters
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
European
Projection
IMR 25 single and dual outputs units
S09039
1
4
2
6
5
5 x 10 (0.4")
70 (2.75")
1.5 (0.06")
3
7
4.5 (0.18")
23 (0.9")
52.5 (2.07")
10 (0.4")
7.5 (0.3")
70 (2.75")
Measuring point
of case temperature TC
IMR 25 triple output units and IMR 40
SD
3
1
4
2
6
5
5 x 10 (0.4")
70 (2.75")
1.5 (0.06")
S09040
7
4.5 (0.18")
23 (0.9")
10 (0.4")
82.5 (3.25")
7.5 (0.3")
100 (3.94")
Measuring point
of case temperature TC
Pin allocation
Pin
1
2
3
4
5
6
7
Single output Dual output
Vi+
Vi+
Vi–
Vi–
Vo+
Vo+
Vo+
Vo+
Vo–
COM
Vo–
COM
n.c.
Vo–
www.power-one.com
Triple output
Vi+
Vi–
Vo1+
COM
Vo2+
COM
Vo3–
3