POWER-ONE IXP

IXP Series
3 Watt DC-DC Converters
Input voltage range up to 72 V DC
1 or 2 outputs up to 30 V DC
3500 V DC I/O electric strength test voltage
• High input to output isolation
• Wide input range
• Short circuit protection
Selection chart
Output 1
Uo nom Io nom
[V DC] [mA]
5
500
5
500
12
250
12
250
15
200
15
200
+5
250
+5
250
+12
125
+12
125
+15
100
+15
100
5
250
5
250
12
125
12
125
15
100
15
100
Output 2
Uo nom Io nom
[V DC] [mA]
–5
250
–5
250
–12
125
–12
125
–15
100
–15
100
5
250
5
250
12
125
12
125
15
100
15
100
Input voltage
Ui
[V DC]
9...36
18...72
9...36
18...72
9...36
18...72
9...36
18...72
9...36
18...72
9...36
18...72
9...36
18...72
9...36
18...72
9...36
18...72
Rated power
TA = 71°C
Po tot [W]
2.5
2.5
3
3
3
3
2.5
2.5
3
3
3
3
2.5
2.5
3
3
3
3
Type
Option
24 IXP 3-05-7
48 IXP 3-05-7
24 IXP 3-12-7
48 IXP 3-12-7
24 IXP 3-15-7
48 IXP 3-15-7
24 IXP 3-0505-7
48 IXP 3-0505-7
24 IXP 3-1212-7
48 IXP 3-1212-7
24 IXP 3-1515-7
48 IXP 3-1515-7
24 IXP 3-05-05-7
48 IXP 3-05-05-7
24 IXP 3-12-12-7
48 IXP 3-12-12-7
24 IXP 3-15-15-7
24 IXP 3-15-15-7
S
S
S
S
S
S
S
S
S
S
S
S
-
Input
Input voltage
Reverse voltage protection
continuous range, 24 V
continuous range, 48 V
shunt diode
9...36 V DC
18...72 V DC
Output
Output voltage setting accuracy
Minimum load
Line regulation
Load regulation
Output voltage switching noise
Efficiency
www.power-one.com
Ui nom, lo nom
recommended
Ui min...Ui max , lo nom
Ui nom, 0...100% lo nom, single output models
dual output models
Ui nom, 20...100% lo nom, peak-peak, total
Ui nom, lo nom
±2% Uo nom
20% lo nom
±1% Uo nom
2% Uo nom
max. 3% Uo nom
max. 3% Uo nom
up to 81%
1
Board Mountable
IXP Series
Control and protection
Ui min, full load
Overload protection
No-load protection
Remote Shut down
125% Pi nom
positive logic (floating or high signal = on)
Safety and EMC
Electric strength test voltage
Electromagnetic interference
I/O
conducted with external filter
3500 V DC
class B
Environmental
Operating ambient temperature Ui nom , lo nom
Storage temperature
non operational
Relative humidity
non condensing
MTBF
MIL-HDBK-217F, N2
–25...71°C
–40...100°C
95%
>3'700'000 h
Options
Industry standard pinout
S
Accessories
DIN and chassis mounting bracket
Mechanical data
Industry standard
Tolerances ±0.3 mm (0.012") unless
otherwise indicated.
European
Projection
31.8 (1.25")
20.3 (0.8")
15.24 (0.6")
2.54 (0.1")
Single output
Vi–
Vi–
n.c.
n.c.
n.c.
Vo+
n.c.
Vo–
Vi+
Vi+
Dual output
Vi–
Vi–
COM
n.c.
Vo–
Vo+
n.c.
COM
Vi+
Vi+
Alternative pinout
Measuring point
of case temperature TC
12 (0.47")
3 (0.12")
S09034
ø 0.5 (0.02")
(
)
www.power-one.com
Pin
2
3
9
10
11
14
15
16
22
23
Pin
1
2
9
10
11
12
13
15
16
20
23
24
Single output Dual output Double output
Vi+
Vi+
Vi+
Vi+
Vi+
Vi+
Go1
COM
COM
Vo–
Vo1
Vo+
Vo–
Vo2
Vo+
Go2
SD
SD
SD
Vi–
Vi–
Vi–
Vi–
Vi–
Vi–
2