OMRON MKS2PN-V-2

General Purpose Relays
MKS
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
General use 100,000 cycles.
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
• UL (RU/CRU), CE and TUV approved.
• RoHS Compliant.
Features
Two-way Action Test Button
Relay in
Normal Operation
For Momentary
Operation
Yellow
button
Pull down the test
button to the first
position, then press the
yellow button with an
insulated tool to
operate the contact.
For Lock
Operation
Pull down the test
button to the second
position.
(The contact is now in
the locked position.)
Model Number Structure
■ Model Number Legend
MKS@@@@@-@-@
1 2 3 4 5
6
7
1. Contact Form
2:
DPDT
3:
3PDT
2. Terminals
P:
Plug-in
3. Mechanical Indicator/Test Button
Blank:Mechanical indicator
I:
Mechanical indicator and lockable test button
4. LED Indicator
Blank: Standard
N:
LED indicator
5. Coil Polarity
Blank: Standard
1:
Reverse polarity (DC coil only)
6. Surge Absorption
Blank:Standard
D:
Surge absorber diode (DC coil only)
V:
Surge absorber varistor (AC coil only)
7. Internal Connections DPDT
Blank: Standard
2:
Non Standard
Internal Connections 3PDT
5:
Standard
Blank: Non Standard
2:
Non Standard
8. Rated Voltage
(Refer to “Coil Ratings”.)
General Purpose Relays
MKS
277
Ordering Information
■ List of Models
Type
Terminals Contact form
Basic
Models
Plug-in
DPDT
3PDT
Models with
LED Indicator
(See note 2.)
DPDT
3PDT
Models with
Diode
(See note 2.)
DPDT
3PDT
Models with
LED Indicator
and Diode
DPDT
3PDT
Models with
Varistor
DPDT
3PDT
Models with
LED Indicator
and Varistor
DPDT
3PDT
Internal connections
(See note 3.)
With mechanical indicator With mechanical indicator Coil ratings
and lockable test button
Standard
MKS2P
MKS2PI
Non Standard
MKS2P-2
MKS2PI-2
Standard
MKS3P-5
MKS3PI-5
Non Standard
MKS3P-2
MKS3PI-2
MKS3P
MKS3PI
Standard
MKS2PN(1)
MKS2PIN(1)
Non Standard
MKS2PN(1)-2
MKS2PIN(1)-2
Standard
MKS3PN(1)-5
MKS3PIN(1)-5
Non Standard
MKS3PN(1)-2
MKS3PIN(1)-2
MKS3PN(1)
MKS3PIN(1)
Standard
MKS2P(1)-D
MKS2PI(1)-D
Non Standard
MKS2P(1)-D-2
MKS2PI(1)-D-2
Standard
MKS3P(1)-D-5
MKS3PI(1)-D-5
Non Standard
MKS3P(1)-D-2
MKS3PI(1)-D-2
MKS3P(1)-D
MKS3PI(1)-D
Standard
MKS2PN-D
MKS2PIN-D
Non Standard
MKS2PN-D-2
MKS2PIN-D-2
Standard
MKS3PN-D-5
MKS3PIN-D-5
Non Standard
MKS3PN-D-2
MKS3PIN-D-2
MKS3PN-D
MKS3PIN-D
Standard
MKS2P-V
MKS2PI-V
Non Standard
MKS2P-V-2
MKS2PI-V-2
Standard
MKS3P-V-5
MKS3PI-V-5
Non Standard
MKS3P-V-2
MKS3PI-V-2
MKS3P-V
MKS3PI-V
Standard
MKS2PN-V
MKS2PIN-V
Non Standard
MKS2PN-V-2
MKS2PIN-V-2
Standard
MKS3PN-V-5
MKS3PIN-V-5
Non Standard
MKS3PN-V-2
MKS3PIN-V-2
MKS3PN-V
MKS3PIN-V
AC/DC
AC/DC
DC
DC
AC
AC
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.
Example: MKS2P DC48
Rated voltage
2. The DC coil comes in two types: standard coil polarity and reverse coil polarity.
Refer to Terminal Arrangement and Internal Connections.
Example: MKS3PN1-5 DC24
Reverse coil polarity
3. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams.
■ 10A Sockets (Order Separately)
Item
Type
Track-mounted
Socket
PF083A-E
11-pin
PF113A-E
8-pin
PF083A-D
11-pin
PF113A-D
Hold-down Clip
(For PF083A-E and PF113A-E)
278
Model
8-pin
General Purpose Relays
PFC-A1
MKS
Specifications
■ Ratings
Coil Ratings
Rated voltage
Rated current
50 Hz
AC
DC
Coil resistance
60 Hz
6V
443 mA
385 mA
3.1 Ω
12 V
221 mA
193 mA
13.7 Ω
24 V
110 mA
96.3 mA
48.4 Ω
110 V
24.2 mA
21.0 mA
932 Ω
120 V
22.2 mA
19.3 mA
1,130 Ω
220 V
12.1 mA
10.5 mA
3,550 Ω
230 V
11.5 mA
10.0 mA
4,250 Ω
240 V
11.0 mA
9.6 mA
4,480 Ω
6V
224 mA
26.7 Ω
12 V
112 mA
107 Ω
24 V
55.8 mA
430 Ω
48 V
28.1 mA
1,710 Ω
100 V
13.5 mA
7,390 Ω
110 V
12.3 mA
8,960 Ω
Must operate
voltage
Must release
voltage
Max. voltage
Power
consumption
80% max. of rated 30% min. of rated 110% of rated voltvoltage
voltage at 60 Hz age
25% min. of rated
voltage at 50 Hz
Approx. 2.3 VA
at 60 Hz
Approx. 2.7 VA
at 50 Hz
15% min. of rated
voltage
Approx. 1.4 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
Contact Ratings
Load
Resistive load
(cosφ = 1)
Contact mechanism
Single
Contact material
Rated load
AgSnIn
NO
10 A, 250 VAC
10A, 30 VDC
NC
5 A, 250 VAC
5 A, 30 VDC
Rated carry current
10 A
Max. switching voltage
250 VAC, 250 VDC
Max. switching current
Max. switching capacity
Inductive load
(p.f. = 0.4)
7 A, 250 VAC
10 A
NO
2,500 VA/300 W
NC
1,250 VA/150 W
General Purpose Relays
MKS
279
■ Characteristics
Contact resistance
100 mΩ max.
Operate time
AC: 20 ms max.
DC: 30 ms max.
Release time
20 ms max.(40 ms max. for built-in diode models)
Max. operating frequency
Mechanical: 18,000 operations/hr (no load)
Electrical:1,800 operations/hr (at rated load)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC 50/60 Hz for 1 min. between coil and contacts
1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity and terminals of the same polarity
2,500 VAC 50/60 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite
polarity
Insulation method
Basic insulation
Impulse withstand voltage
4.5 kV between coil and contacts (with 1.2 × 50 μs impulse wave)
3.0 kV between contacts of different polarity (with 1.2 × 50 μs impulse wave)
Pollution degree
3
Rated insulation voltage
250 V
Vibration resistance
Destruction:10 to 55 Hz, 1.5 mm double amplitude
Malfunction:10 to 55 Hz, 1.0 mm double amplitude
Shock resistance
Destruction:1,000 m/s2 (approx. 100 G)
Malfunction:100 m/s2 (approx. 10 G)
Life expectancy
Mechanical: 5,000,000 operations min.
Electrical:100,000 operations min.
Min. permissible load
10 mA at 1 VDC P level: λ60=0.1 x 10-6 / ops
Ambient temperature
Operating: –40 to 60°C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 90 g
Note: 1. The values given above are initial values.
2. Ambient temperature of models with LED indicator is −25 to 60°C.
■ Approved Standards
UL Recognized (File No. E41515) - - Ambient Temp. = 40°C
Coil ratings
Contact ratings
Operations
6 to 110 VDC N.O.
6 to 240 VAC contact
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
N.C.
contact
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
IEC Standard/TUV Certification: IEC61810-1
(Certification No. R50104853)
Coil ratings
Contact ratings
6, 12, 24, 48, N.O.
100, 110 VDC contact
6, 12, 24, 100,
110, 200, 220,
N.C.
240 VAC
contact
Note: 10A UL ratings are with no load on the other contact set.
Operations
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
5 A, 250 V AC 50/60 Hz (Resistive)
100,000
5 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
Note: Maximum carrying current per TUV Certification is 9 A when
new MK-S relays are mounted in PF083A-E or PF113A-E
Sockets.
CSA Certified by
Engineering Data
■ Reference Data
Rated carry current (A)
Rated Carry Current vs. Ambient Rated Temperature
Switching current (A)
Maximum Switching Power
100
50
30
DC resistive load
with NO contact
AC resistive load
with NO contact
10
UL derating curve
5
10
AC inductive
load
(p.f. = 0.4)
5
3
DC resistive
load with
NC contact
1
10
30
AC resistive load
with NC contact
0
−40
0
20
40
60
80
Ambient temperature (°C)
50
100
300
500 1.000
Switching voltage (V)
280
−20
General Purpose Relays
MKS
Note: The lower limit of the ambient operating temperature for models
with built-in operation indicators is −25°C.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Models without Test Button
Models with Lockable Test Button
34.5 max.
34.5 max.
34.5 max.
0.8
52.5 max.
34.5 max.
0.8
52.5 max.
Track Mounted Sockets
See below for Socket dimensions.
Poles
Finger-protection models
—
Maximum carry current
10 A
5A
2 poles
PF083A-E
PF083A-D
PF083A
3 poles
PF113A-E
PF113A-D
PF113A
Note: If using the PF083A or PF113A Sockets, be sure the maximum carrying current is 5 A or less. When using finger-protection sockets, make
sure the connecting wire terminals are Y-shaped.
PF083A-E (Conforming to EN 50022)
PF113A-E (Conforming to EN 50022)
Terminal Arrangement
Eight, M3.5 × 7 sems
7
Terminal Arrangement
Eleven, M3.5 × 7 sems
4
7
52 max.
4
35.4
52 max.
33
41 max.
3.5
35.4
2
21 max.
Mounting Holes
Two, M4 or two 4.5-dia. holes
4
34
42.8 max.
3.5
2
31 max.
33±0.2
Mounting Holes
Two, M4 or two 4.5-dia. holes
33±0.2
General Purpose Relays
MKS
281
PF113A-D
PF083A-D
8
Terminal Arrangement
24
6
5.5
22
5
12
4
8
Terminal Arrangement
14
3
32 24 21 22 12
8 7 6 5 4
5.5
27
4
27
4
Eight, M4 screws
7
A2
8
21
1
11
Eight, M4 screws
2
A1
9 10
2 3
34 A2 11 1 A1 14
31 11
Mounting Holes
65
65
Mounting Holes
Two, M4 or two 4.5-dia. hole
Two, M4 or two 4.5-dia. hole
30
30
38
38
Hold-down Clips
PFC-A1
(2 pieces per set)
4.6
60.8
6
62
4.5
Mounting Tracks
PFP-100N, PFP-50N
(Conforming to EN 50022)
PFP-100N2
(Conforming to EN 50022)
16
7.3±0.15
4.5
4.5
35±0.3
15
25
25
10
25
1000 (500)*
10
25 *
15 (5)
35±0.3 27
27±0.15
1
15
* The figure in parenthesis is for PFP-50N.
Mounting Height with Sockets
77.8
(See
note.)
Three
poles
Two
poles
74.3
PF083A(-E)
87.8
(See
note.)
84.3
PF113A(-E)
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.
282
General Purpose Relays
MKS
25
25
10
25
1000±4
25 15
10
24
29.2
1
1.5
Terminal Arrangement/Internal Connection (Bottom View)
Basic Models
(AC/DC Coil)
MKS2P(I)
4
MKS2P(I)-2
5
3
4
6
MKS3P(I)
3
6
6
5
7
7
1
2
8
7
1
MKS2P(I)N
4
3
4
6
2
7
1
MKS2P(I)N-2
5
2
7
6
5
7
4
9
3
8
MKS2P(I)N
4
3
4
6
2
7
1
MKS2P(I)N-2
5
2
7
6
5
4
3
4
6
2
7
1
9
3
2
7
6
5
4
3
4
6
2
7
1
8
9
3
2
7
6
5
4
3
4
6
2
7
1
8
6
7
4
8
3
9
2
10
11
1
MKS3P(I)N1-5
8
4
9
3
2
6
5
7
8
3
9
2
10
10
1
11
MKS3P(I)-D-2
7
4
11
MKS3P(I)-D-5
4
8
3
9
6
5
4
8
3
10
9
2
MKS3P(I)1-D
8
3
9
2
10
MKS3P(I)1-D-2
11
1
11
1
7
4
10
11
6
5
7
MKS3P(I)1-D-5
5
3
6
2
7
1
6
1
8
MKS2P(I)1-D-2
5
MKS3P(I)N-5
10
5
7
1
MKS2P(I)1-D
11
1
11
MKS3P(I)N1-2
11
2
Diode Type
(DC Coil:
Reverse Polarity)
9
2
10
MKS3P(I)-D
6
1
9
10
2
5
3
8
8
1
8
MKS2P(I)-D-2
5
8
5
7
3
7
4
1
MKS2P(I)-D
6
4
10
2
Diode Type
(DC Coil:
Standard Polarity)
7
3
10
5
11
MKS3P(I)N1
6
1
6
4
5
3
8
11
MKS3P(I)N-5
11
MKS3P(I)N-2
8
MKS2P(I)N1-2
5
2
1
8
4
1
MKS2P(I)N1
9
7
2
LED Indicator Type
(DC Coil:
Reverse Polarity)
8
3
10
MKS3P(I)N
6
1
1
5
3
8
9
10
5
7
4
11
1
6
5
8
2
LED Indicator Type
(DC Coil:
Standard Polarity)
8
2
10
MKS3P(I)N-2
7
3
11
1
MKS3P(I)N
6
1
9
2
11
6
4
5
3
8
8
3
10
2
1
LED Indicator Type
(AC Coil)
MKS3P(I)-5
5
7
4
9
3
8
6
5
8
4
2
MKS3P(I)-2
5
6
5
7
8
4
3
9
8
2
10
1
11
6
5
4
8
3
9
2
10
1
6
5
7
8
9
3
2
10
1
11
General Purpose Relays
7
4
MKS
11
283
LED Indicator and
Diode Type
(DC Coil)
MKS2P(I)N-D
4
MKS2P(I)N-D-2
5
3
4
6
6
5
7
8
4
2
2
7
1
8
7
1
3
8
9
2
MKS2P(I)-V
4
MKS2P(I)-V-2
5
3
4
1
8
7
1
6
5
MKS2P(I)N-V
4
3
8
9
2
MKS2P(I)N-V-2
5
3
4
2
1
8
6
5
10
11
1
MKS3P(I)-V-5
8
9
2
8
3
9
2
10
11
1
11
MKS3P(I)N-V-2
7
4
10
1
6
5
7
3
11
6
5
7
7
3
9
8
2
10
1
11
6
5
8
4
1
9
2
10
4
10
MKS3P(I)N-V
6
2
7
8
3
11
MKS3P(I)-V-2
7
4
MKS3P(I)N-V-5
5
3
6
2
7
8
1
LED Indicator and
Varistor Type
(AC Coil)
9
1
MKS3P(I)-V
6
2
7
8
3
6
5
7
4
11
4
2
MKS3P(I)N-D-5
5
3
6
6
5
10
1
Varistor Type
(AC Coil)
MKS3P(I)N-D-2
5
3
6
MKS3P(I)N-D
4
8
9
3
2
10
1
6
5
7
7
4
8
3
9
2
11
10
1
11
Safety Precautions
■ Safety Precautions for Correct Use
Installation
Recommend mounting MK-S Relay so that side with wiring diagram is facing down.
Handling
Check coil polarity when wiring LED Indicator and Diode Models.
Test Button
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON.
Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay circuits.
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the
Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only
the requirements for basic insulation are fulfilled.
284
General Purpose Relays
MKS
Omron Electronic Components, LLC
Terms and Conditions of Sales
I. GENERAL
1. Definitions: The words used herein are defined as follows.
(a) Terms:
These terms and conditions
(b) Seller:
Omron Electronic Components LLC and its subsidiaries
(c) Buyer:
The buyer of Products, including any end user in section III through VI
(d) Products: Products and/or services of Seller
(e) Including: Including without limitation
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,
invoices, purchase orders and other documents, whether electronic or in writing, relating
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's
purchase order or other documents which are inconsistent with, or in addition to, these
Terms.
3. Distributor: Any distributor shall inform its customer of the contents after and including
section III of these Terms.
II. SALES
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.
Buyer agrees to pay the price in effect at the time the purchase order is accepted by
Seller. Payments for Products received are due net 30 days unless otherwise stated in
the invoice. Buyer shall have no right to set off any amounts against the amount owing in
respect of this invoice.
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to
Buyer after deducting transportation charges, taxes and duties, and will be allowed only
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past
due amounts owing to Seller.
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum
legal rate, whichever is less, on any balance not paid within the stated terms.
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer
shall make remittance to Seller at the then current exchange rate most favorable to
Seller; provided that if remittance is not made when due, Buyer will convert the amount
to U.S. dollars at the then current exchange rate most favorable to Seller available
during the period between the due date and the date remittance is actually made.
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining
any government approvals regarding the importation or sale of the Products.
7. Taxes: All taxes, duties and other governmental charges (other than general real
property and income taxes), including any interest or penalties thereon, imposed directly
or indirectly on Seller or required to be collected directly or indirectly by Seller for the
manufacture, production, sale, delivery, importation, consumption or use of the Products
sold hereunder (including customs duties and sales, excise, use, turnover and license
taxes) shall be charged to and remitted by Buyer to Seller.
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,
Seller reserves the right to stop shipments or require satisfactory security or payment in
advance. If Buyer fails to make payment or otherwise comply with these Terms or any
related agreement, Seller may (without liability and in addition to other remedies) cancel
any unshipped portion of Products sold hereunder and stop any Products in transit until
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid
accounts.
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer
indemnifies Seller fully against all costs or expenses arising in connection therewith.
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from
causes beyond its control, including earthquakes, fires, floods, strikes or other labor
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,
delay in or lack of transportation or the requirements of any government authority.
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise
stated in writing by Seller), at which point title to and all risk of loss of the Products
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in
the Products until the full purchase price is paid by Buyer;
(b) Delivery and shipping dates are estimates only; and
(c) Seller will package Products as it deems proper for protection against normal
handling and extra charges apply to special conditions.
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products
occurring before delivery to the carrier or any claim related to pricing or other charges
must be presented in detail in writing to Seller within 30 days of receipt of shipment.
III. PRECAUTIONS
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.
Buyer acknowledges that it alone has determined that the Products will meet their
requirements of the intended use in all cases. Buyer must know and observe all
prohibitions of use applicable to the Product/s.
2. Use with Attention: The followings are some examples of applications for which
particular attention must be given. This is not intended to be an exhaustive list of all
possible use of any Product, nor to imply that any use listed may be suitable for any
Product:
(a) Outdoor use, use involving potential chemical contamination or electrical
interference.
(b) Use in consumer Products or any use in significant quantities.
(c) Energy control systems, combustion systems, railroad systems, aviation systems,
medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
(d) Systems, machines, and equipment that could present a risk to life or property.
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY
SELLER.
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of
a programmable Product.
IV. WARRANTY AND LIMITATION
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in
materials and workmanship for a period of twelve months from the date of sale by Seller
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OF THE PRODUCTS.
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form
originally shipped with Buyer responsible for labor charges for removal or replacement
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an
amount equal to the purchase price of the Product; provided that there shall be no
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were
correctly handled, stored, installed and maintained and not subject to contamination,
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be
approved in writing by Seller before shipment.
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its
employees from and against all liabilities, losses, claims, costs and expenses (including
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or
omissions under these Terms or in any way with respect to the Products.
V. INFORMATION; ETC.
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way
without the written permission of Seller. Buyer (at its own expense) shall indemnify and
hold harmless Seller and defend or settle any action brought against Seller to the extent
that it is based on a claim that any Product made to Buyer specifications infringed
intellectual property rights of another party.
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or
tooling, all engineering and tooling shall remain the exclusive property of Seller. All
information and materials supplied by Seller to Buyer relating to the Products are
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted
employees and strictly prevent disclosure to any third party.
3. Performance Data: Performance data is provided as a guide in determining suitability
and does not constitute a warranty. It may represent the result of Seller's test conditions,
and the users must correlate it to actual application requirements.
4. Change In Specifications: Product specifications and descriptions may be changed at
any time based on improvements or other reasons. It is Seller’s practice to change part
numbers when published ratings or features are changed, or when significant
engineering changes are made. However, some specifications of the Product may be
changed without any notice.
5. Errors And Omissions: The information on Seller’s website or in other documentation
has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses
regarding (a) export of the Products or information provided by Seller; (b) sale of
Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information.
VI. MISCELLANEOUS
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing
between Buyer and Seller shall operate as a waiver of rights by Seller.
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any
dispute hereunder.
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller
relating to the Products, and no provision may be changed or waived unless in writing
signed by the parties.
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall
not invalidate any other provision.
General Purpose Relays
MKS
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in
Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
(iii) Use in consumer products or any use in significant quantities.
(iv) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
3. Performance Data. Performance data given in this publication is provided as
a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Seller representative at any time to
confirm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the
best of our knowledge as of the date of this publication, with the requirements
of the European Union's Directive on the Restriction of certain Hazardous
Substances ("RoHS"), although the requirements of RoHS do not take effect
until July 2006. These requirements may be subject to change. Please consult
our website for current information.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X301-E-1
06/09
General Purpose Relays
Specifications subject to change without notice
MKS
Printed in USA