LT140A Hall Device Hall Voltage 160mV Thin-Type Package GaAs Hall Device LT140A ■ Features ¡Small temperature coefficient of the Hall voltage ¡Good linearity of the Hall voltage ¡Small imbalanced voltage ¡Directly DC voltage applicable ■ Outline Dimensions 0.3 0.3 1 4 (Unit : mm) 0.6 0.5 0.05±0.05 2 0.3 0.1 4 0.5 + -0 0.1 .04 2.45 1.45 ¡Brushless motors VCR, CD, CD-ROM, FDD ¡Measuring equipment Gauss meters, magnetic substance detectors ¡Noncontact sensors Microswitches, tape-end detection ¡Other magnetic detection Silver Mark 1.40 ■ Applications 3 0.3 0.9 1.45 Terminal connection 1 : + VC Input 2 : + VH Output 3 : - VC Input 4 : - VH Output 0.2 1.40 ■ Absolute Maximum Ratings (Ta=25˚C) Symbol Rating VC 12 IC 15 150 PD -20 to +125 Topr -55 to +150 Tstg 260 Tsol Unit V mA mW ˚C ˚C ˚C 0.6 0.4 Parameter Control voltage Control current Power dissipation Operating temperature Storage temperature Soldering temperature*1 As for dimensions of tape-packaged products, refer to page 44 . *1 Soldering time : 10 seconds ■ Electrical Characteristics Parameter No-load Hall voltage *1 Imbalanced ratio *2 Rank A Rank B Rank C (Ta=25˚C) Symbol VH Conditions VC=6V, B=100mT VHO/VH VC=6V,(B=0)/(B=100mT) Input resistance Output resistance RIN ROUT Drift of imbalanced voltage vs. temperature |∆VHO| Temperature coefficient of Hall voltage Temperature coefficient of input resistance Linearity of Hall voltage β α γ IM=1mA, B=0mT IM=1mA, B=0mT VC=6V, B=0mT, Ta=-20˚C to 25˚C VC=6V, B=0mT, Ta=25˚C to 125˚C IC=6mA, B=100mT, T1=-20˚C, T2=125˚C IM=1mA, B=0mT, T1=-20˚C, T2=125˚C IC=6mA, B1=50mT, B2=100mT MIN. 145 2 -5 -2 650 1 300 TYP. 160 800 1 600 MAX. 175 12 5 -12 950 1 900 Unit mV - 5 - mV - -0.04 0.2 0.3 - %/˚C %/˚C % % Ω Ω *1 No-load Hall voltage is nearly proportional to Vc (within the range of 1 to 6V) at temperatures of -20˚C to + 125˚C. Keep the voltage within the allowable power dissipation range. *2 Imbalanced ratio is in +/-12% within the range of Vc=1 to 6V. VH=VM-VHO 1 {VH(T2)-VH(T1)} β= X100 X VH(T1) (T2-T1) {RIN(T2)-RIN(T1)} 1 X X100 α= (T2-T1) RIN(T1) {KH(B2)-KH(B1)} VH X2X100, KH= γ= (ICXB) {KH(B1)+KH(B2)} VM:Observed Hall voltage VHO:Imbalanced voltage KH:Sensitivity In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device spcification sheets before using any SHARP device. Hall Device Fig. 1 LT140A Hall Voltage vs. Ambient Temperature VC=6V 160 IC=6mA 120 80 40 0 -20 Fig. 3 1 200 1 200 800 0 40 80 120 Ambient temperature Ta (˚C) Hall Voltage vs. Control Current 400 B=100mT Ta=25˚C 320 240 160 80 400 0 Fig. 5 160 80 0 4 8 12 Control voltage VC (V) 4 8 12 Control current IC (mA) Power Dissipation vs. Ambient Temperature 200 Power dissipation PD (mW) 240 0 Fig. 6 B=100mT Ta=25˚C 320 0 0 200 400 600 800 1 000 Magnetic flux density B (mT) Hall Voltage vs. Control Voltage 400 Hall voltage VH (mV) 400 Fig. 4 VC=6V Ta=25˚C 1 600 0 800 0 -20 Hall voltage VH (mV) Hall voltage VH (mV) 2 000 B=0mT IM=1mA 1 600 0 40 80 120 Ambient temperature Ta (˚C) Hall Voltage vs. Magnetic Flux Density Input Resistance vs. Ambient Temperature 2 000 B=100mT Input resistance RIN (Ω) Hall voltage VH (mV) 200 Fig. 2 160 120 80 40 0 0 40 80 120 160 Ambient temperature Ta (˚C) 200