SHARP LT262A

Hall IC
LT262A
LT262A
GaAs Hall IC for Noncontact Switch
(Alternating magnetic field-type*)
*Zero-cross is not warranted.
■ Outline Dimensions
(Unit : Fmm)
0.85
4
2
Z
0.95
S
3
2.9±0.2
0.4
Y
1
0.6
2.7±0.3
2.9±0.2
1.9
■ Features
¡Operation by small magnet due to high sensitivity
Operating point<10mT
¡Combining a GaAs Hall device and an IC in a compact
package (2.9X1.5X1.1mm)
¡Wide operation temperature range obtained by GaAs Hall
device (-20 to +125˚C)
¡Long life time due to noncontact-type
0.4
0.4
X
4-R0.2
Hall device center line
X : +0.05±0.23mm against package center
Y : -0.05±0.1mm against package lead center between
No.2 and No.3 terminals
Z : 0.81±0.15mm from package surface
Terminal connections
1.5±0.2
0.6
0.6
REG
Hall
+
device
H
+0.2
0.8
(0to0.15)
1.1-0.1
0.16+0.10
-0.06
0.3
■ Applications
¡FDD
¡HDD
¡Water meter
¡Car stereo
¡Microswitch, etc.
-
1 : VCC
2 : VOUT
3 : Don't use.
4 : GND
*No.3 terminal and the section of leads (both sides
of package in X direction) are connected with the
terminal of internal IC. Be careful in connecting other circuits.
Parameter
Supply voltage
Output voltage
Output current
Power dissipation
Operating temperature
Storage temperature
Soldering temperature*1
(Ta=25˚C)
Symbol
Rating
VCC
8
VOUT
8
IO
5
PD
100
Topr
-20 to +125
Tstg
-55 to +150
Tsol
260
Unit
V
V
mA
mW
˚C
˚C
˚C
As for dimensions of tape-packaged products, refer to page 44 .
■ Operating Explanation
Output voltage
■ Absolute Maximum Ratings
<Alternating magnetic field-type>
*1 Soldering time : within 10 seconds
BRP 0 BOP
+B
Magnetic flux density
■ Electrical Characteristics
Parameter
Operating magnetic flux density
Hysteresis breadth
Operating voltage
Supply current
Low level output voltage
Output leakage current
Operating point temperature drift
(Ta=25˚C)
Symbol
BOP
BRP
BH
VCC
ICC
VOL
IOH
∆BOP
Condition
VCC=5V
VOO=5V
RL=10kΩ
VCC=5V, B=<-10mT
IO=4mA, B>=10mT
VCC=5V, B=<-10mT, VOO=5V
VCC=5V, Ta=-20˚C to +80˚C
MIN.
-10
3.5
-6
TYP.
-
MAX.
10
5
6.5
10.5
0.4
10
6
Unit
mT
mT
mT
V
mA
V
µA
mT
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices
shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device spcification sheets before using any SHARP device.
Hall IC
LT262A
Operating Magnetic Flux Density
vs. Supply Voltage
Ta=25˚C
12
8
4
BOP
0
BRP
-4
Fig. 2
Operating magnetic flux density B (mT)
Operating magnetic flux density B (mT)
Fig. 1
-8
-12
12
4
-8
-12
Supply current ICC (mA)
Supply current ICC (mA)
6
4
2
0.4
0.3
0.2
0.1
0
1
2
3
4
Output current IO (mA)
4
2
0.5
VCC=5V
B>=10mT
Ta=25˚C
5
VCC=5V
B=<-10mT
6
Fig. 6
Low level output voltage VOL (V)
Low level output voltage VOL (V)
0.5
Supply Current vs. Ambient
Temperature
8
0
4.0
5.0
6.0
Supply voltage VCC (V)
Low Level Output Voltage vs.
Output Current
0
Fig. 4
10
8
Fig. 5
BRP
-4
B=<-10mT
Ta=25˚C
0
BOP
0
-40
0
40
80
120
Ambient temperature Ta (˚C)
Supply Current vs. Supply Voltage
10
VCC=5V
8
4.0
5.0
6.0
Supply voltage VCC (V)
Fig. 3
Operating Magnetic Flux Density vs.
Ambient Temperature
0.4
-40
0
40
80
120
Ambient temperature Ta (˚C)
Low Level Output Voltage vs.
Ambient Temperature
VCC=5V
IO=4mA
B>=10mT
0.3
0.2
0.1
0
-40
0
40
80
120
Ambient temperature Ta (˚C)