TEMIC TSC691E

TSC691E
Integer Unit
User’s Manual
for Embedded Real time 32–bit Computer
(ERC32)
for SPACE Applications
TSC691E
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. TSC691E Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1. SPARC RISC Standard Functions : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2. Fault Tolerant and Test Mechanism Improvements : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3. Presentation of the ERC32 computing core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.1. Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.2. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2
2
2
3
3. Standard IU Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2. Description Of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3. Programming Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3.1. Register Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3.1.1. Windowing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3.1.1.1. Parameter Passing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3.1.1.2. Window Overflow and Underflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3.1.1.3. Alternate Register Window Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3.1.2. Special Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3.2. Processor States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3.3. Supervisor/User Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3.4. Control/Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3.4.1. Program Counters (PC and nPC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3.4.2. Processor State Register (PSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.3.4.3. Window Invalid Mask Register (WIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.3.4.4. Trap Base Register (TBR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.3.4.5. Y Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3.5. Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3.5.1. Data Organization In Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3.5.2. Data Organization In Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.3.5.3. Extended Precision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.4. Instruction Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.4.1. Instruction Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.4.2. Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.2.1. Two Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.2.2. Register Plus 13-Bit Immediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.2.3. 13-Bit Immediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.2.4. CALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4.2.5. Branch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4.2.6. ASI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.4.3. Instruction Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.4.3.1. Load/Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.4.3.1.1. ASI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.4.3.1.2. Multiprocessing Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4.3.2. Arithmetic/Logical/Shift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.4.3.2.1. Register r[0] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
MATRA MHS
Rev. G (10/09/96)
toc1
TSC691E
3.4.3.2.2. SETHI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.2.3. Tagged Arithmetic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.3. Control Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.3.1. Branching and the Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.3.2. Trap Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.3.3. Calls and Returns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.4. Delayed Control Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.4.1. PC and nPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.4.2. Delay Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.4.3. Annul Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.4.4. Delayed Control Transfer Couples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.5. Read/Write Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.6. Floating-Point-Operate and Coprocessor-Operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3.7. Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4. Op Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.1. Load/Store Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.2. Arithmetic/Logical/Shift Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.3. Control Transfer Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.4. Read/Write Control Register Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.5. Floating-Point/Coprocessor Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.6. Miscellaneous Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.4.7. Opcodes In Ascending Numeric Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5. Signal Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1. Memory Subsystem Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.1. A<31:0>—Address Bus (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.2. APAR—Address Bus Parity (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.3. AOE—Address Output Enable (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.4. ASI<7:0>—Address Space Identifier (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.5. ASPAR—ASI and SIZE Parity (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.6. BHOLD—Bus Hold (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.7. COE—Control Output Enable (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.8. D<31:0>—Data Bus (bidirectional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.9.DPAR—Data Bus Parity (bidirectional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.10. DOE—Data Output Enable (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.11. DXFER—Data Transfer (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.12. IFT—Instruction Cache Flush Trap (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.13. INULL—Integer Unit Nullify Cycle (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.14. LDSTO—Atomic Load–Store (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.15. LOCK—Bus Lock (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.16. MAO—Memory Address Output (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.17. MDS—Memory Data Strobe (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.18. MEXC—Memory Exception (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.19.MHOLD(A/B)—Memory Holds (inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.20. RD—Read Access (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.21. SIZE<1:0>—Bus Transaction Size (outputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.22. WE—Write Enable (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.23. WRT—Advanced Write (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1.24. IMPAR—IU to MEC Control Parity (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2. Floating-Point/Coprocessor Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.1. CCC<1:0>—Coprocessor Condition Codes (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.2. CCCV—Coprocessor Condition Codes Valid (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
toc2
25
25
25
26
27
28
29
29
29
30
30
34
34
35
35
35
37
39
41
41
42
43
51
54
54
54
54
54
55
55
55
55
56
56
56
56
56
56
57
57
57
57
57
57
58
58
58
58
58
58
59
MATRA MHS
Rev. G (10/09/96)
TSC691E
3.5.2.3. CEXC—Coprocessor Exception (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.4. CHOLD—Coprocessor Hold (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.5. CINS1—Coprocessor Instruction in Buffer 1 (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.6. CINS2—Coprocessor Instruction in Buffer 2 (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.7. FP—Coprocessor Unit Present (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.8. CXACK—Coprocessor Exception Acknowledge (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.9. FCC<1:0>—Floating-Point Condition Codes (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.10. FCCV—Floating-Point Condition Codes Valid (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.11. FEXC—Floating-Point Exception (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.12. FHOLD—Floating-Point Hold (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.13. FIPAR—FPU to IU Control Parity (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.14. FINS1—Floating-Point Instruction In Buffer 1 (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.15. FINS2—Floating-Point Instruction In Buffer 2 (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.16. FLUSH—Floating-Point/Coprocessor Instruction Flush (output) . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.17. FP—Floating-point Unit Present (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.18. FXACK—Floating-Point Exception Acknowledge (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.19. INST—Instruction Fetch (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.2.20. IFPAR—IU to FPU Control Parity (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3. Interrupt and Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.1. ERROR—Error State (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.2. HWERROR—Hardware error (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.3. FLOW —Enable FLOW Control (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.4. MCERR—Comparison error (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.5. 601MODE—Normal 601MODE Operation (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.6. CMODE—checker Mode (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.7. FPSYN—Floating-point Synonym Mode (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.8. INTACK—Interrupt Acknowledge (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.9. IRL<3:0>—Interrupt Request Level (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.10. RESET—Integer Unit reset (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.11. TOE—Test Mode Output Enable (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.3.12. HALT—HALT (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.4. TAP signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.4.1. TCLK—Test Clock (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.4.2. TRST—TEST reset (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.4.3. TMS—Test Mode Select (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.4.4. TDI—Test Data Input (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.4.5. TDO—Test Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.5. Power and Clock Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.5.1. CLK—Clock (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.5.2. VCCO, VCCI, VCCT—Power (inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.5.3. VSSO, VSSI, VSST—Ground (inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6. Pipeline and Instruction Execution Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1.Stages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1.1. Internal Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.2. Multicycle Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.2.1. Register Interlocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.2.2. Branching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.3. Pipeline Freezes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.4. Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7. Bus Operation and Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.1. Instruction Fetch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MATRA MHS
Rev. G (10/09/96)
59
59
59
59
59
59
59
59
60
60
60
60
60
60
60
60
61
61
61
61
61
61
61
61
61
61
62
62
62
62
62
62
62
62
62
62
63
63
63
63
63
63
64
64
65
67
67
69
69
69
72
toc3
TSC691E
3.7.2. Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
3.7.3. Load with Interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
3.7.4. Load Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
3.7.5. Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
3.7.6. Store Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
3.7.7. Atomic Load–Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
3.7.8. Floating-Point Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
3.7.9. Bus Arbitration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
3.7.10. Load with Cache Miss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
3.7.11. Store with Cache Miss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
3.7.12. Load/Store instruction with Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
3.7.13. Memory Exceptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
3.7.14. Floating-Point Exceptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
3.7.15. Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
3.7.16. Reset Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
3.7.17. Error Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
3.8. Exception Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
3.8.1. Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
3.8.2. Synchronous Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
3.8.2.1. External Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
3.8.2.2. Hardware error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.3. Instruction access exception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.4. Data access exception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.5. Internal/Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.6. Illegal instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.7. Privileged instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.8. Fp disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.9. Cp disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
3.8.2.10. Window overflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
3.8.2.11. Window underflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
3.8.2.12. Memory address not aligned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
3.8.2.13. Tag overflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
3.8.2.14. Trap instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
3.8.3. Interrupts (Asynchronous Traps) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
3.8.3.1. Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
3.8.3.2. Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
3.8.3.2.1. Instruction Response Time on conditional branch instruction (CBI) . . . . . . . . . . . . . . . . . . . . 101
3.8.3.3.Interrupt Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
3.8.4. Floating-Point/Coprocessor Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
3.8.4.1. Floating-Point Exception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
3.8.4.2. Coprocessor Exception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
3.8.5. Trap Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
3.8.5.1. Recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
3.8.5.2. Trap Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
3.8.5.3. Trap Types and Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
3.8.5.4. Return From Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
3.9. Coprocessor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
3.9.1. Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
3.9.1.1. Coprocessor Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
3.9.2. Register Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
3.9.3. Exceptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
toc4
MATRA MHS
Rev. G (10/09/96)
TSC691E
4. Fault Tolerant and Test Mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
4.1. Fault Tolerant and Test Support signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2. Program Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.2. Example of Program Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3. Parity Checking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2. Trap handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.3. Priority within hardware traps for IU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.4. Parity Checking on Register File and Control/Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5. Parity Checking on Control Signal for the FPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5.1. Output control signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5.2. Input control signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.6. Parity Checking on Control Pads for the TSC693E (MEC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.6.1. Output control signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.6.2. Input control signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.7. Parity Checking on Control Pads for the Coprocessor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.8. Parity Generation on ADDRESS Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.9. Parity Checking on DATA Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.10. Non RT 601 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.11. Error Type for external signals parity errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4. Master/checker operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1. Basic function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1.1. Master/Checker Signal description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1.1.1. MCERR—Comparison Error (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1.1.2.CMODE—checker Mode (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5. IEEE Standard Test Access Port & Boundary-Scan Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1. TAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1.1. TCLK (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1.2. TMS (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1.3. TDI (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1.4. TRST (input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1.5. TDO (output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.2. TAP Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3. The Instruction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3.1. Design and Construction of the instruction register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3.2. BYPASS Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3.3. EXTEST Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3.4. INTEST Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3.5. SAMPLE/PRELOAD Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.4. The Device Identification Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.5. Internal Scan Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.6. Boundary scan test register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.Interleaving register file bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
108
109
109
109
110
110
110
111
111
112
112
112
112
112
112
112
112
112
113
113
113
113
114
114
114
114
114
115
115
115
115
115
115
115
115
116
116
116
116
116
116
116
117
5. Electrical and Mechanical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
5.1. Maximum rating and DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.1. Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.2. Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.3. DC Characteristics Over the Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.4. Capacitance Ratings [7,8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MATRA MHS
Rev. G (10/09/96)
118
118
118
118
119
toc5
TSC691E
5.1.5. AC Test Loads and Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2. TSC691E AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.1. AC Characteristics Over the Operation Range [1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2. Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.1. Clock and ERROR / RESET Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.2. Clock and HWERROR Timing for Parity Error Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.3. TOE De–assertion /Assertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.4. Load Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.5. Store Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.6. Load with Cache Miss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.7. Memory Exception Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.8. Bus Arbitration Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.9. Floating-Point Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.10. TAP Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.11. PARITY Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.12. MASTER/CHECKER Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.13. IRL[3:0] Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2.14. HALT Signal timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3. Package Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.1. 256-Pin MQFP_F Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.2. 256-Pin MQFP_F Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
toc6
119
119
119
122
122
122
123
123
124
125
126
126
127
127
128
128
129
129
130
130
131
MATRA MHS
Rev. G (10/09/96)
TSC691E
List of Figures
Figure 1. ERC32 Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2. Integer Unit Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Figure 3. SPARC Register Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 4. Circular Stack of Overlapping Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 5. Overlapping Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 6. Registers as Seen by a Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 7. Register Banks for Fast Context Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 8. Processor State Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 9. Window Invalid Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 10. Trap Base Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 11. Processor Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 12. Byte Operand Load and Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 13. Data Organization in Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 14. Extended–Precision Data Organization in Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 15. Extended–Precision Data Organization in Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 16. Instruction Format Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 17. Address Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 18. Tagged Data Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 19. Ticc Trap Address Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 20. Delayed Control Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 21. Delayed Control Transfer Couples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 22. TSC691E External Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 23. ASI timing with a WRPSR Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 24. Processor Instruction Pipeline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 25. Pipeline with All Single–Cycle Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 26. Pipeline with One Double–Cycle Instruction (Load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 27. Pipeline with One Triple–Cycle Instruction (Store) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 28. Pipeline with Hardware Interlock (Load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 29. Pipeline During Branch Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 30. Branch with Annulled Delay Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 31. Pipeline Frozen During Bus Arbitration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 32. Pipeline Operation for Taken Trap (Internal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Figure 33. Data Bus Contents During Data Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Figure 34. Instruction Fetch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 35. Load Single Integer Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 36. Load Single with Interlock Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 37. Load Double Integer Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 38. Store Single Integer Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 39. Store Double Integer Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 40. Atomic Load–Store Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Figure 41. Floating–Point Operation Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 42. Bus Arbitration Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
MATRA MHS
Rev. G (10/09/96)
fig.1
TSC691E
Figure 43. Load with Cache Miss Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 44. Store with Cache Miss Timing (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Figure 45. Store with Cache Miss Timing (2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 46. Ld, LdSt, St and Swap Inst with Trap Taken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Figure 47. Load with Memory Exception Timing (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Figure 48. Load with Memory Exception Timing (2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Figure 49. Instruction Memory Access Exception Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Figure 50. Instruction Memory Access Exception Timing (LD in Execute stage) . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Figure 51. Store with Memory Exception Timing (page 1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figure 52. Store with Memory Exception Timing (page 2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Figure 53. Store double with Memory Exception on 1st data address (page 1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 54. Store double with Memory Exception on 1st data address (page 2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Figure 55. Store double with Memory Exception on 2nd data address (page 1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 56. Store double with Memory Exception on 2nd data address (page 2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 57. Floating–Point Exception Handshake Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Figure 58. Asynchronous Interrupt Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Figure 59. Power–On Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Figure 60. Error/Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Figure 61. Best–Case Interrupt Response Timing (one cycle instruction) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 62. Double Cycles Instruction Interrupt Response Timing (ex: Load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 63. Triple-Cycles Instruction Interrupt Response Timing (ex: Store) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Figure 64. Four-Cycles Instruction Interrupt Response Timing (Store Double) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Figure 65. Interrupt Response Timing on conditional branch instruction (B*A,a & B*cc,aNT) . . . . . . . . . . . . . . . 101
Figure 66. Coprocessor Register Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Figure 67. Master/Checker configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Figure 68. Instruction Register Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Figure 69. Boundary Scan Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
fig.2
MATRA MHS
Rev. G (10/09/96)
TSC691E
List of Tables
Table 1. Register Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 2. Floating–Point Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 3. Extended–Precision Floating–Point Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 4. op field Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 5. op2 Field Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 6. ASI Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 7. Load/Store Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 8. Arithmetic/Logical/Shift Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 9. Control Transfer Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 10. Control Transfer Instruction Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 11. Bicc and Ticc Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 12. FBfcc Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 13. CBccc Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 14. Delayed Control Transfer Instruction Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 15. Effect of Annul Bit Reset (a=0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 16. Effect of Annul Bit Reset (a=1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 17. Effect of Annul Bit on Delay Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 18. Delayed Control Transfer Couple Instruction Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 19. Execution of Delayed Control Transfer Couples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 20. Read/Write Control Register Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 21. Floating–Point–Operate and Coprocessor–Operate Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 22. Miscellaneous Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 23. Load/Store Instruction Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 25. Arithmetic/Logical/Shift Instruction Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 27. Control Transfer Instruction Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 28. Bicc and Ticc Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 29. FBfcc Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 30. CBccc Condition Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 31. Read/Write Control Register Instruction Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 32. Floating–Point /Coprocessor Instruction Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 33. Miscellaneous Instruction Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 34. Instruction Opcode Numeric Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 35. Instruction Opcode Numeric Listing (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 36. Instruction Opcode Numeric Listing (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 37. Instruction Opcodes Numeric Listing (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 38. Instruction Opcodes Numeric Listing (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Table 39. TSC691E External Signal Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 40. TSC691E External Signal Summary (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 41. ASI Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 42. SIZE Bit Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
MATRA MHS
Rev. G (10/09/96)
tab.1
TSC691E
Table 43. Internally Generated Opcodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 44. Externally Generated Synchronous Exception Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 45. Trap Type and Priority Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Table 46. Trap Type and Priority Assignments (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Table 47. Error Type Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Table 48. Hardware Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Table 49. Hardware error type for user registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Table 50. Hardware error type for external signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
tab.2
MATRA MHS
Rev. G (10/09/96)
TSC691E
TSC691E RT Integer Unit
1. Introduction
This document presents the specification of the TSC691E RT Integer Unit. It is organized in three main chapters:
D Standard IU (TSC691E) Functions (Chapter 3)
D Fault MECHANISM and Test MECHANISM (Chapter 4)
D Electrical and Mechanical Specification (Chapter 5)
Chapter 3 presents the SPARC RISC USER’S GUIDE from Cypress Semiconductor including some adaptations due
to the introduction of fault tolerant MECHANISMs, without losing the full binary compatibility with the entire SPARC
V7.0 application software base.
Chapter 4 and Chapter 5 deal with the new added functions introduced in the TSC691E to improve the reliability of
space applications. These new functions also do not impact the SPARC V7.0 compatibility.
MATRA MHS
Rev. H (02 Dec. 96)
1
TSC691E
2. TSC691E OVERVIEW
2.1. SPARC RISC STANDARD FUNCTIONS :
D
D
D
D
D
D
Full binary compatibility with entire SPARC V7.0 application software base
Architecture efficiency that sustains 1.25 to 1.5 clocks per instruction
Large windowed register file
Tightly coupled floating-point interface
User/supervisor modes for multitasking
Semaphore instructions and alternate address spaces for multiprocessing
2.2. Fault Tolerant and Test Mechanism Improvements:
D
D
D
D
D
D
D
D
Parity checking on 98.7% of the total number of latches with hardware error traps
Parity checking of address, data pads and control pads
Program flow control
Master/Checker operation
IEEE Standard Test Access Port & Boundary-Scan Architecture
Possibility to disable the bus parity checking
Manufactured using TEMIC Space hardened 0.8 µm SCMOS RT TECHNOLOGY
Part of the ERC32 high performance 32-bit computing core
To support applications requiring an extremely high level of reliability, the following improvements were introduced
in the standard SPARC RISC processor TSC691:
D Several independent fault detection MECHANISMs to support the design of fault tolerant systems
D Such as odd parity checking, Program Flow Control and Master/Checker operations.
D Support of sophisticated PC board level test using the IEEE Standard Test Access Port and
D Boundary Scan Architecture
D Hardening of the process by construction, applying restricted full static CMOS design rules for
D all critical blocks of the circuit such as register file, PLAs, ROMs etc...
D Hardened device processing using the TEMIC 0.8 µm SCMOS-RT TECHNOLOGY.
Thanks to careful handling of the improvements, the introduced modifications have neither reduced
the performance of the device nor changed the full binary compatibility with the entire SPARC V7.0
application software.
2.3. Presentation of the ERC32 computing core
The TSC691E Integer Unit is, with the TSC692E Floating Point Unit and the TSC693E (Memory controller), a part
of the ERC32 computing core.
2.3.1. Concept
The objective of the ERC32 is to provide a high performance 32-bit computing core, with which computers for
on-board embedded real-time applications can be built. The core will be characterized by low circuit complexity and
power consumption. Extensive concurrent error detection and support for fault tolerance and reconsideration will also
be emphasized.
In addition to the main objective the ERC32 core should be possible to use for performance demanding research
applications in deep space probes. The radiation tolerance and error masking are therefore important. For the real-time
2
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
applications the system might be fail-operational rather than fail-safe. By including support for reconfiguration of the
error-handling the different demands from the applications can be optimized for the best purpose in each case.
The ERC32 will be used as a building block only requiring memory and application specific peripherals to be added
to form a complete on-board computer. All other system support functions are provided by the core.
2.3.2. Functional Description
The ERC32 incorporates the followings functions:
D Processor, which consists of one integer unit and one floating point unit. The processor includes concurrent error
detection facilities.
D Memory controller (TSC693E), which is a unit consisting of all necessary support functions such as memory control
and protection, EDAC, wait state generator, timers, interrupt handler, watch dog, UARTs and test and debug
support. The unit also includes concurrent error detection facilities.
D Oscillator (optional).
D Buffers necessary to interface with memory and peripherals.
Figure 1 schematically shows the ERC32 architecture and external functions added to form a complete system.
I/O Port
DATA
Memory Port
Address
Address Port
Floating
Point Unit
TSC692E
Chip Select
WE
QE
Integer
Unit
TSC691E
Memory
Controller
I/O Select
TSC693E
I/O Ready
I/O R/W
IRQ
IRQ Ack
EDAC checkbit
DMA Port
Figure 1. ERC32 Architecture
MATRA MHS
Rev. H (02 Dec. 96)
3
TSC691E
3. Standard IU Function
3.1. Introduction
This section describes the workings of the TSC691E Integer processing Unit (IU), the main computing engine in the
SPARC architecture. The TSC691E RT is based on the SPARC 32-bit RISC architecture, which defines a processor
capable of execution at a rate approaching one instruction per clock cycle. The TSC691E supports a tightly-coupled
Floating-Point coprocessor Unit (FPU) and a second, system-specific coprocessor, all three of which may operate
concurrently. The TSC691E executes all instructions except floating-point-operate and coprocessor-operate
instructions.
A block diagram of the TSC691E is shown in Figure 2 . The processor is organized around the ALU and the shift unit.
These are both two-operand units, accepting 32-bit information from either source 1 or source 2 of the register file,
the program counters, or the instruction decoder. ALU or shift unit results may be passed to the register file, address
bus, program counters, control registers, or back to themselves. One of the characteristics of the SPARC load/store
architecture is that neither the ALU nor the shift unit directly pass results to the instruction/data bus. Memory data
moves in and out of the register file through alignment units to and from the instruction/data bus. Instructions are taken
directly from the bus and fed to a four-stage instruction pipeline.
Destination
Register File
136 x 32bits
Source 1
Source 2
Arithmetic
and Logic
Unit
Shift Unit
PC Adder
Program
Counters
Align
Processor State
Window Invalid
Trap Base
Multiply Step
Address
Align
Instruction
Decode
Instruction/ Data
Figure 2. Integer Unit Block Diagram
4
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
IU REGISTER
FPU Registers (optional)
PROCESSOR STATE REG (PSR)
SUPERVISOR
ONLY
Coprocessor Registers (optional)
FLOATING POINT QUEUE
(FPQ) (3)
COPROCESSOR QUEUE (CPQ)
FLOATING POINT STATUS
(FSR)
COPROCESSOR STATUS (CSR)
TRAP BASE REG (TBR)
WINDOW INVALID MASK
(WIM)
MULTIPLY STEP (Y)
WORKING
OUTS (8)
REGISTERS
INS(8)
Current window
within set of
FLOATING-POINT REGISTERS
(32)
COPROCESSOR REGISTERS
(32)
LOCALS(8)
GLOBALS(8)
136 r Registers
Figure 3. SPARC Register Model
The SPARC architecture uses a “windowed” register file model in which the file is divided up into groups of registers
called windows. This windowed register model simplifies compiler design, speeds procedure calls, and efficiently
supports A/I programming languages such as Prolog, LISP and Smalltalk.
A unique pair of coprocessor interfaces and a common connection to the system data and virtual address busses form
the physical interface between the IU, the FPU, and a coprocessor. The coprocessor interfaces provide the
synchronization and error handling that enable all three processors to operate concurrently. A common interface to the
virtual address bus and data bus permits the IU to provide all addresses for floating–point and coprocessor load and
store instructions.
3.2. Description Of Parts
The integer unit TSC691E contains a 136 x 32 register file divided into eight overlapping windows. It is supplied in
256-pins MQFP packages, which allows 32-bit address and data busses, an eight-bit ASI bus, a number of control lines,
and floating-point–coprocessor, second coprocessor interfaces and 29 signals supporting fault tolerance and test
MECHANISM.
3.3. Programming Model
This section describes the TSC691E’s register model, register window MECHANISM, processor states,
supervisor/user modes, control/status registers, and data types. The concepts and properties explained here are central
to an understanding of the TSC691E’s operation.
The register set shown in Figure 3 is a snapshot of the registers the TSC691E sees at any given moment. The working
registers constitute the current window on the register file. Registers within the shaded area are accessible only in the
supervisor mode.
Working registers are used for normal operations and are called r registers in the TSC691E, f registers in the FPU, and
c registers in the coprocessor. The various control/status registers keep track of and/or control the state of each
processor.
3.3.1. Register Windows
The 136 r registers of the TSC691E are 32–bits wide and are divided into a set of 128 window registers and a set of
eight global registers. The 128 window registers are grouped into eight sets of 24 r registers called windows.
MATRA MHS
Rev. H (02 Dec. 96)
5
TSC691E
Table 1. Register Addressing
Register numbers
Name
r[24] to r[31]
ins
r[16] to r[23]
locals
r[8] to r[15]
outs
r[0] to r[7]
globals
The SPARC architecture supports a maximum of 32 windows. The currently active window (the window visible to the
programmer) is identified by the Current Window Pointer (CWP), a 5-bit field in the Processor State Register (PSR)
(see Section 3.3.4.2).
At any given time, a program can address 32 active registers: 24 window registers and the eight globals. By software
convention, the window registers are divided into 8 ins, 8 locals, and 8 outs. Registers are addressed as shown in
Table 1 .
The current window pointer (CWP) acts as an index pointer within the stack of 128 window registers. Changing the
current window pointer by one offsets r register addressing by 16. Since 24 r registers can be addressed by a single CWP
value, incrementing or decrementing the CWP results in an eight register overlap between windows. This overlap of
window registers is used to pass parameters from one window to the next.
3.3.1.1. Windowing
The register file is implemented as a circular stack, with the highest numbered window joined to the lowest. In the
TSC691E, window 7 adjoins window 0 (see Figure 4 ).
CWP
W7
w7 ins
w7 locals
w7 outs
w0 outs
w1 outs
w0 ins
RESTORE
w6 ins
w0 locals
W0
w6 locals
W6
W1
w5 ins
w1 locals
w6 outs
GLOBALS
SAVE
w2 outs
w1 ins
w5 locals
W5
W2
W4
w2 locals
w2 ins
w4 ins
w4 locals
w5 outs
w4 outs
w3 outs
w3 locals
w3 ins
W3
Figure 4. Circular Stack of Overlapping Windows
6
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Previous Window (CWP + 1)
r 31
.
.
r 24
r 23
.
.
r 16
r 15.
.
r8
Save
INS
Restore
LOCALS
OUTS
Current Window (CWP)
r 31
.
.
INS
r 24
r 23
.
.
LOCALS
r 16
r 15.
.
OUTS
r8
Next Window (CWP - 1)
r 31
.
.
r 24
r 23
.
.
r 16
r 15.
.
r8
r7
.
.
r0
INS
LOCALS
OUTS
GLOBALS
Figure 5. Overlapping Windows
Note that each window shares its ins and outs with adjacent windows (refer to Figure 5 ). Outs from a previous window
(CWP+1) are the ins of the current window, and the outs of the current window are the ins of the next window
(CWP - 1). While only adjacent windows share ins and outs, globals are shared by all windows. A window’s locals,
on the other hand, are not shared at all, belonging only to that window.
After power–on reset, the state of the current window pointer and the WIM register (see Section 3.3.4.3) are undefined.
The power–on reset trap routine must initialize the CWP and WIM register for correct operation.
3.3.1.1.1. Parameter Passing
Register window overlap provides an efficient means of passing parameters during procedure calls and returns. One
method of implementing a procedure call that takes advantage of the overlap is to have the calling procedure move
the parameters to be passed into its outs registers, then execute a CALL instruction. A SAVE instruction then
decrements the CWP to activate the next window. The calling procedure’s outs become the called procedure’s ins,
making the passed parameters directly accessible.
When a called procedure is ready to return results to the procedure that called it, those results are moved into its ins
registers and it then executes a return, usually with a JMPL instruction. A RESTORE instruction increments the CWP
to activate the previous window. The called procedure’s ins are still the calling procedure’s outs; thus the results are
available to the calling procedure. Note that the terms ins and outs are defined relative to calling, not returning.
If the calling procedure must pass more parameters than can be accommodated by the outs and globals, the additional
parameters must be passed on the memory stack. One method of handling the stack pointer is to dedicate an out register
in the current window to hold the stack pointer (see Figure 6 ). After a call, this pointer (which is now in an ins register)
can be used as the frame pointer for the called procedure. The SAVE instruction, in addition to decrementing the CWP,
also performs an ADD using registers from the current window and placing the result in a register in the next window.
This feature can be used to set a new stack pointer for the called procedure from the old pointer in the calling procedure.
RESTORE also performs an ADD, using registers in the current window and placing the result in the previous window.
MATRA MHS
Rev. H (02 Dec. 96)
7
TSC691E
in
local
out
global
floating
point
r31
r30
r29
r28
r27
r26
r25
r24
r23
r22
r21
r20
r19
r18
r17
r16
r15
r14
r13
r12
r11
r10
r9
r8
r7
r6
r5
r4
r3
r2
r1
r0
f31
:
f0
(i7)
(FP)
return address
frame pointer
(i5) incoming param reg 5
(i4) incoming param reg 4
(i3) incoming param reg 3
(i2) incoming param reg 2
(i1) incoming param reg 1
(i0) incoming param reg 0
(l7)
(l6)
(l5)
(l4)
(l3)
(l2)
(l1)
(l0)
(o7)
(SP)
local 7
local 6
local 5
local 4
local 3
local 2
local 1
local 0
temp
stack pointer
(o5) outgoing param reg 5
(o4) outgoing param reg 4
(o3) outgoing param reg 3
(o2) outgoing param reg 2
(o1) outgoing param reg 1
(o0) outgoing param reg 0
(g7)
(g6)
(g5)
(g4)
(g3)
(g2)
(g1)
(g0)
global 7
global 6
global 5
global 4
global 3
global 2
global 1
0
floating–point value
:
floating–point value
Figure 6. Registers as Seen by a Procedure
3.3.1.1.2. Window Overflow and Underflow
No matter how many windows a register file has, it is possible that at some point the program will try to use more than
are available. Since the register file is a circular stack, something must be done to prevent overwriting the oldest
window as the stack wraps around.
The TSC691E handles this by allowing bits in the Window Invalid Mask (WIM) register to be set, which are used to
mark windows that will trigger an underflow or overflow trap (see Section 3.3.4.3). If a SAVE instruction points the
8
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
CWP to a marked window, a window overflow trap is generated. This means that in the TSC691E, only seven of the
eight windows are available for calls, because the last window must be saved for the trap handler. However, since a
typical overflow trap handler would transparently save one or more of the oldest windows to memory, the program sees
an apparently infinite number of windows.
The TSC691E automatically decrements the CWP upon encountering a trap. This happens without generating another
window overflow trap, regardless of the state of the WIM register. By setting at least one window as masked by the
WIM register, the system is assured of at least one window for use by the trap handler.
A RESTORE instruction will cause a window underflow trap if it attempts to restore to a window invalidated by the
WIM register. Execution of a return from Trap (RETT) instruction under the same circumstances will also generate
an under trap. SAVE, RESTORE, and RETT always check the WIM register before completing their actions.
As an example, in Figure 4 , if the procedure using the window labeled w0 executes a CALL and SAVE sequence, a
window overflow trap will occur (assuming WIM bit 7 is set). The overflow trap handler may safely use only the locals
of w7, because w7’s ins are w0’s outs and w7’s outs are w6’s ins.
Active window = 0
Previous window = 1
Next window = 7
Trap window = 7
CWP = 0
CWP+1 = 1
CWP-1 = 7
WIM = 10000000(base 2)
The overflow trap handler is responsible for saving one or more of the least recently used windows to the memory stack.
Simulations of register file management methods show that saving and restoring one window at a time is the simplest
and most effective algorithm for handling overflow and underflow. The stack pointer to the window-save area must
be aligned to a word boundary in valid memory and, for efficiency, should be doubleword aligned. This is because it
is faster to load and store doublewords than to load and store words.
A linear sequence of doubleword loads and stores is also used to speed up context switches. In a context switch, only
the windows containing valid data are saved, and on average this is about half the number of TSC691E windows, minus
one for the reserved trap window.
3.3.1.1.3. Alternate Register Window Usage
Although the windowing layout is particularly well suited to procedure calls and returns, hardware does not force their
use for that purpose alone. Except for the eight-register overlap and the partial fixing of the function of several registers
by the instruction set (see Section 3.3.1.2), register windows can be viewed and manipulated as needed to fit the
application at hand.
For example, the register set can be treated as a flat register file. Access to any particular register in any window is
obtained by writing its window value into the current window pointer located in the processor state register. Moreover,
windows naturally segment registers into blocks that could be dedicated to specific purposes and accessed through the
CWP. Register saving and parameter passing could be done with a standard push/pop stack in memory, although this
would substantially increase bus traffic.
For real-time and embedded controller systems, where fast context switching may be more important than procedure
calling, the register file can easily be divided into banks of registers separated by trap handling windows set up by the
WIM register (see Section 3.3.4.3). Switching from one register bank to another is accomplished by writing to the CWP
field of the processor state register. Figure 7 shows the TSC691E register file divided into four banks, each with its
own trap handler window of eight local registers. Globals are accessible by all processes.
3.3.1.2. Special Registers
In general, the window registers seen at any given time can be used in any manner desired, while keeping in mind that
windows overlap at both ends. However, the instruction set does fix the use of r[0] and partially fixes the use of r[15].
Global register r[0] always returns the value 0 when read, making the most frequently used constant easily available
at all times. In addition, when addressed as a destination operand, r[0] discards the value written to it.
The CALL instruction writes its own address into register r[15] (out register 7) of the calling procedure’s window. If
a SAVE instruction then activates a new window, r[15] of the old window becomes r[31] (in register 7) of the new
window and serves as the return address to the calling procedure. However, if the register is needed for some other
purpose, the return address can be saved to a stack or simply overwritten.
MATRA MHS
Rev. H (02 Dec. 96)
9
TSC691E
WIM Register
Register Bank 3
(Window 7)
Register Bank 2
(Window 5)
Register Bank 1
(Window 3)
Register Bank 0
(Window 1)
r31
.
r24
r23
.
r16
r15
.
r8
r31
.
r24
r23
.
r16
r15
.
r8
r31
.
r24
r23
.
r16
r15
.
r8
r31
.
r24
r23
.
r16
r15
.
r8
r31
.
r24
r23
.
r16
r15
.
r8
r31
.
r24
r23
.
r16
r15
.
r8
0
1
0
1
0
1
0
1
7
6
5
4
3
2
1
0
The WIM register is used to separate the r registers into register banks. Register banks are
switched by writing into the CWP field of the
processor state register (PSR).
RESERVED
Trap registers for bank 3
(Window 6)
UNUSED
The TSC691E automatically enters the next window (CWP 1) upon encountering a trap, regardless of the state of the
WIM register. This feature is used to reserve windows for a
trap handler.
RESERVED
Trap registers for bank 2
(Window 4)
UNUSED
The upper eight registers of the trap window are reserved for
parameter passing from the register bank, if desired.
r31
.
r24
r23
.
r16
r15
.
r8
r31
.
r24
r23
.
r16
r15
.
r8
RESERVED
Trap registers for bank 1
(Window 2)
UNUSED
The lower eight registers of the trap window are unused, since
they are shared with the next register bank. These can be used
to pass parameters to the next register bank, if desired.
RESERVED
Trap registers for bank 0
(Window 0)
UNUSED
r7
GLOBAL
. REGISTERS
.
r0
Figure 7. Register Banks for Fast Context Switching
10
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Two other registers are also used by hardware to save information during a trap. Registers r[17] and r[18] (locals 1 and
2) of the trap window (not the trapping procedure’s window) are used to save the contents of the program counters (PC
and nPC) at the time the trap is taken. Because the trap window locals are all a trap handler is allowed to use (unless
it saves to the system stack), this limits the trap handler’s usable registers to six.
3.3.2. Processor States
The TSC691E is always in one of three possible states: execute mode, reset mode, or error mode. Execute mode is the
normal operating mode.
The processor enters error mode (at which point it halts and asserts ERROR) if a synchronous trap is generated while
traps are disabled (see Section 3.8). The TSC691E remains in error mode until the RESET signal is asserted, whereupon
it enters reset mode. The external system is responsible for asserting RESET whenever the error mode signal, ERROR,
is detected.
Reset mode is entered whenever the RESET signal is asserted (see Section 3.5). The processor remains in that mode
until RESET is deasserted. RESET signal must be asserted nine clocks at least. Upon deassertion, the processor enters
execute mode, where the first instruction address to be executed is address 0 in the supervisor instruction address space
(see Sections 3.3.3 and 3.4.2.6).
The TSC691E fetches instructions in the execute mode. If the instruction belongs to the floating-point unit or second
coprocessor, execution is directed to the appropriate coprocessor. Otherwise, the instruction is executed by the integer
unit.
3.3.3. Supervisor/User Modes
In support of multitasking, the TSC691E employs a supervisor/user model of operation. The processor is in supervisor
mode when the S bit in the Processor State Register (PSR) is set, and in user mode when S is reset (see Section 3.3.4.2).
The state of this bit determines which address space is accessed with the ASI bits (see Section 3.4.2.6) and whether
or not privileged instructions may be used. Privileged instructions restrict control register access to supervisor software,
preventing user programs from accidentally altering the state of the machine.
In non-multitasking situations, such as embedded systems, user (application) code would probably run in supervisor
mode to gain access to the PSR’s CWP field and other control registers. The only way a program running in user mode
may enter supervisor mode is to encounter a software or hardware trap. A return to user mode is accomplished by
executing a Return from Trap (RETT) instruction, which restores the state of the S bit to what it was before the trap
was taken. A commonly used trap return is the JMPL, RETT delayed control transfer couple (refer to Section 3.4.3.4.4).
This restores both the PC and nPC and the previous state of the S bit.
3.3.4. Control/Status Registers
TSC691E control/status registers are all 32 bits wide. The two program counters can only be read to and written to
indirectly using such instructions as a CALL, JMPL, software trap (Ticc), and Return from Trap (RETT). The Processor
State Register (PSR), Window Invalid Mask (WIM), Trap Base Register (TBR), and multiply-step register (Y), are all
read/write registers. Read/write instructions that access the PSR, WIM, and TBR are privileged and thus may only be
used in supervisor mode.
Two of these registers, the PSR and TBR, have both read-only status fields and programmable read/write mode fields.
In Figure 8 and Figure 10 , the read-only status fields appear in lower case italic (for example, impl) while the writable
mode fields appear in UPPER CASE (for example, PIL).
3.3.4.1. Program Counters (PC and nPC)
The Program Counter (PC) contains the address of the instruction currently being executed by the TSC691E, and the
next Program Counter (nPC) holds the address (PC + 4) of the next instruction to be executed (assuming there is no
control transfer and a trap does not occur). The nPC is necessary to implement delayed control transfers, wherein the
instruction that immediately follows a control transfer may be executed before control is transferred to the target
address (see Section 3.4.3.4). Having both the PC and nPC available to the trap handler allows a trap handler to choose
between retrying the instruction causing the trap (after the trap condition has been eliminated) or resuming program
execution after the trap causing instruction.
MATRA MHS
Rev. H (02 Dec. 96)
11
TSC691E
3.3.4.2. Processor State Register (PSR)
Trap Enable (ET)
Previous Supervisor Mode (PS)
Supervisor Mode (S)
Enable Floating-Point Unit (EF)
Enable Coprocessor (EC)*
IU
IU
Implementation Version
Number
Number
(impl)
(ver)
4
31
4
28 27
Integer
Condition
Codes
(ICC)
Reserved
4
6
24
1
1
4
14 13 12 11
negative
(N)
23
zero
(Z)
22
Current
Window
Pointer
(CWP)
Processor
Interrupt
Level
(PIL)
overflow
(V)
21
1
8
1
7 6
1
5 4
5
0
carry
(C)
20
Figure 8. Processor State Register
This is the TSC691E’s key status and control register, containing fields that report the status of processor operations
or control processor operations. Instructions that modify its fields include SAVE, RESTORE, Ticc, RETT, and any
instruction that modifies the condition code field (icc). Any hardware or software action that generates a trap will
modify the S, PS, and ET fields. The PSR may be read or written directly using the privileged instructions RDPSR and
WRPSR. The PSR is made up of the following fields:
impl—Implementation
Bits 28 through 31 contain the processor’s implementation number. The implementation number for the TSC691E
is 001. WRPSR does not modify this field.
ver—Version
Bits 24 through 27 contain the TSC691E’s version number. WRPSR does not modify this field. The current version
number for the TSC691E is 0001.
icc—Integer Condition Codes
Bits 20 through 23 hold the integer unit’s condition codes. These bits are modified by arithmetic and logical instructions whose names end with the letters cc (for example, ANDcc), and can be overwritten by the WRPSR instruction.
The Bicc and Ticc instructions base their control transfer on these bits, which are defined as follows:
N—Negative
Bit 23 indicates whether the ALU result was negative for the last icc-modifying instruction.
0 = not negative
1 = negative
Z—Zero
Bit 22 indicates whether the ALU result was zero for the last icc-modifying instruction.
0 = result was nonzero
1 = result was zero
V—Overflow
Bit 21 indicates whether an arithmetic overflow occurred during the last icc-modifying instruction. The
overflow bit is also set if a tagged operation (TADDcc, TSUBcc, etc.) is performed on non–tagged operands
(refer to Section 3.4.3.2.3). Logical instructions that modify the icc field always set the overflow bit to 0.
0 = arithmetic overflow did not occur
1 = arithmetic overflow did occur
C—Carry
Bit 20 indicates whether an arithmetic carry out of result bit 31 occurred from the last icc-modifying addition
or if a borrow into bit 31 resulted from the last icc-modifying subtraction. Logical instructions that modify
the icc field always set the carry bit to 0.
0 = a carry/borrow did not occur
12
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
1 = a carry/borrow did occur
Reserved
Bits 14 through 19 are reserved. A WRPSR should write only 0s to this field.
EC—Coprocessor Enabled
This bit determines whether the optional second coprocessor is enabled or disabled.
0 = disabled
1 = enabled
If the coprocessor is either disabled or enabled but not present, a CPop, CBccc, or coprocessor load/store instruction
will cause a coprocessor-disabled trap. When the CP is disabled, it retains that state until it is re–enabled or reset.
Even when disabled, the coprocessor can continue to execute instructions if it contains a queue.
EF—Floating-Point Unit Enabled
Bit 12 determines whether the FPU is enabled or disabled.
0 = disabled
1 = enabled
If the FPU is either disabled or enabled but not present, an FPop, FBfcc, or floating-point load/store instruction will
cause a floating-point-disabled trap. When disabled, the FPU retains that state until it is re–enabled or reset. Even
when disabled, it can continue to execute any instructions in its queue.
PIL—Processor Interrupt Level
Bits 8 through 11 identify the processor’s external interrupt priority level. The processor will only accept external
interrupts whose interrupt level is greater than the value in PIL. Bit 11 of the PIL is the MSB and bit 8 is the LSB.
S—Supervisor
Bit 7 determines whether the processor is in supervisor or user mode. Because WRPSR is privileged and only available in the supervisor mode, supervisor mode can only be entered by a software or hardware trap.
0 = user mode
1 = supervisor mode
PS—Previous Supervisor
Bit 6 holds the value that was in the S bit at the time the most recent trap was taken.
ET—Enable Traps
Bit 5 determines whether traps are enabled. If traps are disabled, all asynchronous traps are ignored. If a synchronous or floating-point/coprocessor trap occurs while traps are disabled, the TSC691E halts and enters the error
mode (see Section 3.8).
0 = traps disabled
1 = traps enabled
CWP—Current Window Pointer
Bits 0 through 4 contain a pointer to the currently active register file window. CWP is decremented by traps and the
SAVE instruction, and is incremented by RESTORE and RETT instructions.
The Floating-Point Enabled (EF) bit can be used by the programmer to control FPU use when running multiple
processes. By disabling the EF bit while running a process that doesn’t require the FPU, software would not have to
save and restore the FPU’s registers across context switches. If the FPU is not present, as signaled by the input signal,
FP, the EF bit can be used to provoke floating-point instruction set emulation by generating a floating-point-disabled
trap if execution of a floating-point instruction is attempted. This technique may be used with the coprocessor as well.
If it is necessary for the software to manually disable traps, care must be taken when changing the ET bit from enabled
(ET=1) to disabled (ET=0), since the RDPSR, WRPSR instruction sequence is interruptible. One way to handle that
is to write all interrupt trap handlers so that before they return program control to the supervisor software that was
interrupted, they restore the PSR to the value it had before the interrupt was taken. This will guarantee a correct result
when the interrupted RDPSR, WRPSR sequence continues. The only PSR bit that cannot be restored is the PS bit, which
is overwritten when the trap is taken.
An alternative to the RDPSR-WRPSR sequence is to generate a “trap instruction” trap with a Ticc instruction. A taken
trap automatically sets ET to 0, disabling further traps.
MATRA MHS
Rev. H (02 Dec. 96)
13
TSC691E
Window 0
Window 1
Window 2
Window 3
etc.
. . . . .
Future Expansion for Additional Windows
7
31
6
5
4
3
2
1
0
Figure 9. Window Invalid Mask
Trap Base Address (TBA)
Trap
Type
(tt) 8
20
31
12
4
0
0
0
0
3
2
1
0
Figure 10. Trap Base Register
3.3.4.3. Window Invalid Mask Register (WIM)
This register designates which window(s) will cause generation of an underflow or overflow trap when pointed to by
the CWP as the result of a SAVE, RESTORE, or RETT instruction.
Each bit in the WIM register (see Figure 9 ) corresponds to a window; if a bit is set to 1, the window corresponding
to that bit is marked as invalid. If a SAVE, RESTORE, or RETT instruction would cause the CWP to point to a window
whose WIM bit equals 1, a window overflow (SAVE) or window underflow (RESTORE, RETT) trap is generated. The
trap handler uses the local registers of the invalidated window.
A WIM bit is usually set by the operating system software to identify the boundary between the oldest and newest
window. The overflow or underflow trap prevents previous windows from being overwritten or restores previous
windows from memory. WIM can also be used to mark off register banks for fast context switching (see Section
3.3.1.1.3).
WIM is read by the RDWIM instruction, and written by the WRWIM instruction. Bits corresponding to unimplemented
windows read as zeros and are unaffected by writes.
NOTE: The WIM register is NOT cleared during reset. It must be initialized by software.
3.3.4.4. Trap Base Register (TBR)
When a trap occurs, the program counter (PC) is loaded with the contents of the trap base register. The TBR contains
two fields that together constitute a pointer into the trap table, which in turn contains the trap handler address (see
Figure 10 ). RDTBR can read the entire register; however, the WRTBR instruction can write only to the Trap Base
Address field. Only hardware can write to the Trap Type field, and bits 0 through 3 are zeros and are unaffected by
a write. The Trap Type field can be directly manipulated using the Ticc instruction. For more information on trap
operation, see Section 3.8.
TBA—Trap Base Address
Bits 12 through 31 contain the most-significant 20 bits of the trap table address. This field applies to all trap types except
reset, which forces address 0. The TBA is software controlled.
tt—Trap Type
Bits 4 through 11 comprise the Trap Type field, an eight-bit value that provides an offset into the trap table based on
the type of trap being taken (see Section 3.8.5.3). This field retains its value until the next trap is taken.
14
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
3.3.4.5. Y Register
The Y register is used by the multiply step instruction (MULScc) to create 64-bit products. This register is read and
written using the non-privileged RDY and WRY instructions.
Table 2. Floating–Point Formats
Single–Precision Floating–Point Format
s = sign (1)
e = biased exponent (8)
f = fraction (23)
normalized number (0 < e < 255):
subnormal (e=0):
f#0
zero (e=0):
f#0
(-1)S * 2e-127 * 1.f
(-1)S * 2 - 126 * 0.f
(-1)S * 0
signaling NaN:
f#0
quiet NaN:
infinity:
f#0
s=u; e=255 (max); f=.0uuu-uu
(at least one bit must be nonzero)
s=u; e=255 (max); f=.1uuu-uu
s=0 or 1, depending upon sign;
e=255 (max); f=.00-00 (all zeros)
Double–Precision Floating–Point Format
s = sign (1)
e = biased exponent (11)
f = fraction (52)
normalized number (0 < e < 2047):
subnormal (e=0):
f#0
zero (e=0):
f#0
(-1)S * 2e-1023 * 1.f
(-1)S * 2 - 1022 * 0.f
(-1)S * 0
signaling NaN:
f#0
quiet NaN:
infinity:
f#0
s=u; e=2047 (max); f=.0uuu-uu
(at least one bit must be nonzero)
s=u; e=2047 (max); f=.1uuu-uu
s=0 or 1, depending upon sign;
e=2047 (max); f=.00-00 (all zeros)
3.3.5. Data Types
The TSC691E supports ten data types (eleven with extended-precision floating-point, see Section 3.3.5.3). Integer
types include byte, unsigned byte, halfword, unsigned halfword, word, unsigned word, doubleword, and tagged data.
ANSI IEEE 754-1985 floating-point types include single- and double-precision. A byte is 8 bits wide, halfwords are
16 bits, words and single-precision floating-point are 32 bits, doublewords and double-precision floating-point are 64
bits. Table 2 shows the formats for single-precision and double-precision floating–point numbers.
MATRA MHS
Rev. H (02 Dec. 96)
15
TSC691E
BYTE
SSS................. SSS
S
BYTE
8 7 6
31
UNSIGNED
BYTE
000 ................. 000
S S S . . . . . . . . . .S S S
31
UNSIGNED
HALFWORD
SIGNED
WORD
UNSIGNED
WORD
TAGGED
DATA
BYTE
8 7
31
HALFWORD
S
16 15 14
000 ..........000
0
HALFWORD
0
HALFWORD
16 15
31
0
0
WORD
S
0
31
WORD
31
0
TAG
2 1 0
WORD
31
DOUBLE
WORD
r(N)
WORD 0 (MOST SIGNIFICANT WORD)
r(N+1)
WORD 1 (LEAST SIGNIFICANT WORD)
31
SINGLE
PRECISION FP
S
EXPONENT
31 30
S
DOUBLEPRECISION FP
0
EXPONENT
FRACTION
23 22
0
HIGH-ORDER BITS OF FRACTION
LOW-ORDER BITS OF FRACTION
20 19
31 30
0
f(N)
f(N+1
)
Figure 11. Processor Data Types
3.3.5.1. Data Organization In Registers
The organization of the ten data types when loaded into registers is shown in Figure 11 .
When moving memory data to or from the registers, byte operands are always loaded to or extracted from the lower
eight bits of a register. On a load, bits 8 through 31 are sign-extended for a byte or zero-extended for an unsigned byte.
Halfwords are always loaded to or extracted from the lower 16 bits of a register. Bits 16 through 31 are sign-extended
for a halfword or zero-extended for an unsigned halfword during a load. All 32 bits of a signed or unsigned word are
loaded from or stored to memory. Stores of byte and halfword data are not sign–extended. Tagged data is handled as
an unsigned word. Doubleword operands load to and store from two contiguous registers, r[n] and r[n+1], with r[n]
containing the most significant word. Figure 12 illustrates the relationship between the way data is stored in memory
and the way it is loaded into registers.
For single-precision, floating-point operands, bit 31 contains the sign bit, bits 23 through 30 contain the eight bits of
exponent, and bits 0 through 22 contain the 23-bit fraction. Double-precision operands require a register pair, with the
upper-order register (r[n]) containing the sign bit, 11-bit exponent, and the high-order bits of the fraction. The
lower-order register (r[n+1]) contains the low-order bits of the fraction. Total fraction size is 52 bits.
When loading doublewords or double-precision operands from memory to the working registers (either r or f), the
destination register must be at an even address or the hardware will force such an address. For example, an attempted
load double to register r[9] would be forced to r[8], so that the most significant word would be loaded in r[8] and the
least significant word in r[9]. A load double to r[0] would result in the loss of the most significant word.
16
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Address N
N+1
N+2
Memory location
31
24
Destination Register
31
Zeroes or Sign Extension
23
16 15
N+3
8
7
0
7
0
Byte Load Example (From Address N+1)
Address N
N+1
Data Bus
31
Source Register
31
24 23
N+2
16 15
Don’t Care
N+3
8 7
0
7
0
Byte Store Example (To Address N+2)
Figure 12. Byte Operand Load and Store
Doubleword
63
Word
31
15
Halfword
7 Byte 0 7 Byte
N
N+1
0 15
0
Word
0 31
Halfword
0 15
Halfword
0 7 Byte 0 7 Byte 0 7 Byte 0 7 Byte
N+2
N+3
N+4
N+5
0 15
0
Halfword
0 7 Byte
N+6
0
7 Byte 0
N+7
Figure 13. Data Organization in Memory
3.3.5.2. Data Organization In Memory
Organization and addressing of data in memory follows the “Big-Endian” convention wherein lower addresses contain
the higher-order bytes (see Figure 13 ). For a stored word, address N corresponds to the most significant byte of the
word, and address N+3 corresponds to the least significant byte. The address of a halfword, word, or doubleword is
also the address of its most significant byte. A halfword datum must be located on a halfword boundary (address bit
<0> = 0), which is evenly divisible by 2. Similarly, a word must be located on a word boundary (address bits <1:0>
= 0) evenly divisible by 4, and a doubleword must be located on a doubleword boundary (address bits <2:0> = 0) evenly
divisible by 8. Attempting to access misaligned data will generate a memory_address_not_aligned trap.
3.3.5.3. Extended Precision
The SPARC architecture supports another data type, an ANSI/IEEE 754-1985 extended-precision floating-point type
with a width of 128 bits (see Table 3 ). When loaded to the working registers, extended-precision operands require a
register quadruple (see Figure 14 ). The upper-order register (r[N]) contains the sign bit, a 15-bit exponent, and a 16-bit
reserved field. The next register (r[N+1]) contains the one-bit integer part and 31 high-order bits of the fraction. The
next register (r[N+2]) holds the 32 low-order bits of the fraction. Total fraction size is 63 bits. The fourth
extended-precision register (r[N+3]) is reserved. As with double-precision operands, when loading an
extended-precision operand, the destination register must be at an even address or the hardware will force an even
address.
The memory address of an extended-precision datum is also the address of its most significant byte (see Figure 15 ).
An extended-precision datum must be located on an extended-precision boundary (address bits <3:0> = 0), which is
evenly divisible by 16.
MATRA MHS
Rev. H (02 Dec. 96)
17
TSC691E
Table 3. Extended–Precision Floating–Point Format
s = sign (1)
e = biased exponent (15)
j = integer part (1)
f-msb f-lsb = f = fraction (63)
normalized number ( 0 < e < 32767; j = 1 ):
subnormal number ( e = 0; j = 0 ) (f # 0):
zero ( s = 0; e = 0) (f # 0) (j # 0):
(-1) s * 2 e-16383 * j.f
(-1) s * 2 -16383 * j.f
(-1) s * 0
signaling NaN:
f#0
quiet NaN:
f#0
s = u; e = 32767 (max); j = u;
f = .0 uuu uu (at least one bit
must be nonzero)
s = u; e = 32767 (max); j = u;
f = .1 uuu uu
s = 0 or 1, depending upon sign;
e = 32767 (max); j = u;
f = .000 00 (all zeroes)
infinity:
EXTENDED PRECISION FP
r[N]
S
r[N + 1]
J
EXPONENT
RESERVED
HIGHORDER BITS OF FRACTION
r[N + 2]
LOWORDER BITS OF FRACTION
r[N + 3]
RESERVED
31 30
16 15
0
Figure 14. Extended–Precision Data Organization in Registers
Extended – Precision Data
128
63
31
0 31
Address N
N+4
Doubleword
0 63
Doubleword
Word
0
Word
0
31
N+8
Word
0
31
0
Word
0
N+12
Figure 15. Extended–Precision Data Organization in Memory
3.4. Instruction Set
This section describes the TSC691E instruction set as defined by the SPARC architecture. Included are subsections
on instruction formats, addressing, instruction types, and an op code summary. A specific document, SPARC V7.0
Instruction Set contains a description of the assembly language syntax and a complete set of instruction definitions.
3.4.1. Instruction Formats
There are only three basic instruction formats plus three subformats. Format 1 is used for the CALL instruction, format
2 for the SETHI [1] and Branch instructions, and format 3 for the remaining integer and floating-point/coprocessor
instructions. Figure 16 shows each format with its fields, bit positions, and the instructions that use that format. All
instructions are one word long and aligned on word boundaries in memory. For most instructions, operands are located
in source registers (represented by rs1 and rs2). The remaining instructions use one source register plus a displacement
or immediate operand contained within the instruction itself.
Note:
1. See chapter 4.2 for application of this instruction in Program Flow Control.
18
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
CALL
FORMAT 1
opcode
(op)
31
30-Bit Displacement (disp30)
30
0
SETHI
opcode Destination (rd)
(op)
31
30
25
opcode
(op2)
22
opcode a
(op)
31
30 29
opcode
(op2)
22
22-Bit Immediate (imm22)
0
BRANCH
FORMAT 2
Test Cond.
25
22-Bit Displacement (disp22)
0
OTHER INTEGER INSTRUCTIONS
opcode
(op)
Destination (rd)
opcode
(op3)
Source 1 (rs1)
0
opcode
(op)
Destination (rd)
opcode
(op3)
Source 1 (rs1)
1
31
30
25
19
Alternate Space (asi)
Source 2 (rs2)
13-Bit Immediate (simm13)
14 13
5
0
FORMAT 3
FLOATING POINT/COPROCESSOR OPERATIONS
opcode Destination (rd)
(op)
31
30
25
opcode
(op3)
FP Opcode (opf)
CP Opcode (opc)
Source 1 (rs1)
19
14
Source 2 (rs2)
5
0
Figure 16. Instruction Format Summary
a
asi
cond
disp22
disp30
i
imm22
op
op2
op3
opc
opf
rd
rs1
rs2
The a (annul) bit is used in branch instructions to control the execution of the delay instruction that immediately follows a control transfer instruction (see Section 3.4.3.4.3).
The address space identifier is an eight-bit field used in load/store alternate instructions. See Section
3.4.2.6.
This field identifies the condition code used for a branch instruction.
This field contains the 22-bit displacement value used for PC-relative addressing for a taken branch. It is
sign extended to full-word size when used.
This field contains the 30-bit displacement used for the PC-relative addressing of a CALL instruction.
The i (immediate) bit determines whether the second ALU operand (for non-FPop instructions) will be
r[rs2] (i = 0), or a sign-extended simm13 (i = 1).
This field contains the 22-bit constant used by the SETHI instruction. (See Chapter 4.2 for Program Flow
Control)
The op field selects the instruction format as shown in Table 4 .
The op2 field (Table 5 ) contains the instruction opcode for format 2 instructions (op=0).
The 6–bit op3 field contains the instruction opcode for a format 3 instruction (op = 2 or 3).
The 9–bit opc identifies a coprocessor–operate (CPop) instruction. The relationship between the opc field
and CPop instructions is described in Section 3.4.3.6.
The 9-bit opf identifies a floating-point-operate (FPop) instruction. The relationship between the opf field
and FPop instructions is described in Section 3.4.3.6.
The r register (or r register pair) or f register (or f register pair) specified in the rd field serves as the source
during store instructions. For all other instructions, the identified register (register pair) serves as the destination. Note that r[0] as a source supplies the value 0, and as a destination causes the result to be discarded. Note that rd must be a r register for integer instructions and must be a f register for floating–point
instructions.
The 5-bit rs1 field identifies the register containing the first source operand. The source is a r register for
integer instructions, a f register for floating–point instructions, or a c register for coprocessor instructions.
The 5-bit rs2 field identifies the register containing the second source operand. The source is a r register for
integer instructions, a f register for floating–point instructions, or a c register for coprocessor instructions.
MATRA MHS
Rev. H (02 Dec. 96)
19
TSC691E
simm13
This field holds the 13-bit immediate value used as the second ALU operand when i = 1. It is sign-extended
to full-word size when used.
Table 4. op field Coding
op Value
Instruction
00
01
10 or 11
Bicc, FBfcc, CBccc, SETHI
Call
Other
Table 5. op2 Field Coding
op2 Value
000
010
100
110
111
Instruction
Unimplemented
Bicc
SETHI
FBfcc
CBccc
Unused (reserved) bit patterns which are used in the op, op2, op3, or i (wrong bit used) fields of instructions will cause
an illegal_instruction trap. Fields that are not used for a particular instruction are ignored and so will not cause a trap,
regardless of the bit pattern placed in that field. Unused or reserved bit patterns used in the opf or opc fields of a
floating–point or coprocessor instruction cause an fp exception or a cp exception.
3.4.2. Addressing
Because it uses a load/store architecture, the TSC691E needs only four address modes. Memory address generation
is done only for load and store instructions and is byte oriented. Program counter-relative addressing is generated only
for calls and branches and is word-boundary oriented because it is addressing instructions. Register-indirect addressing
applies to jumps, returns, and traps and is also word-boundary oriented. Address generation is illustrated in Figure 17 .
3.4.2.1. Two Register
Two-register addressing uses the rs1 and rs2 fields (instruction format 3) to specify two source registers whose 32-bit
contents are added together to create a memory address. This is a load/store (or register-indirect) addressing mode.
3.4.2.2. Register Plus 13-Bit Immediate
This addressing mode is used where an immediate value is required as one of the sources. The address is generated
by adding the 32-bit source register specified by rs1 (format 3) to a 13-bit, sign-extended immediate value contained
in the instruction. This is a load/store (or register-indirect) addressing mode.
3.4.2.3. 13-Bit Immediate
Immediate addressing is a special case of register-plus-immediate addressing. In this case, the rs1-specified register
is r[0] (whose value is 0), which means the address is generated using only the 13-bit immediate value. Use of this
special case allows absolute addressing of the upper and lower 4 kbytes of a memory (or instruction) space with the
13-bit immediate value. Immediate addressing is the simplest method of addressing because no registers need be set
up beforehand.
20
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
31
0
Register Source 1
0
31
+
Memory Address
(Program Counter)
+
Memory Address
(Program Counter)
Register Source 2
0
31
Register Source 1
31
0
13
Sign Extension
31
13-Bit Immediate
0
13
Sign Extension
13-Bit Immediate
Memory Address
(Program Counter)
LOAD/STORE(JMPL, RETT)
0
31
Program Counter + 4
31
1
30-Bit Displacement
0
+
Program Counter
+
Program Counter
0 0
CALL
0
31
Program Counter + 4
31
24
Sign Extension
2
22-Bit Displacement
1
0
0 0
BRANCH
Figure 17. Address Generation
3.4.2.4. CALL
Address generation for the CALL instruction is program counter-relative, that is, the target address is based on the
program counter. Because the TSC691E is a delayed-control-transfer machine (see Section 3.4.3.4), before the address
is calculated, the PC is replaced by the nPC, so the calculation is actually done with PC + 4 (see Figure 17 ).
An address is generated by adding this PC + 4 value to the 30-bit word displacement contained in the CALL instruction.
The displacement is formed by appending two zeros to the 30-bit value from the instruction. This allows control
transfers to any word-boundary location in the virtual memory instruction space. The result of the address generation
becomes the new nPC.
3.4.2.5. Branch
Branch instructions also use PC-relative addressing, but in this case, the value added to PC + 4 is a sign-extended 22-bit
word displacement. Again, the displacement is formed by appending two zeros to the 22-bit value contained in the
branch instruction and then sign extending out to 32 bits. This allows a branching range of 8 Mbytes on word
boundaries. The generated address becomes the new nPC.
MATRA MHS
Rev. H (02 Dec. 96)
21
TSC691E
Table 6. ASI Assignments
TSC691E Address Space Identifier (ASI)
Address Space
00001000 (08 H)
User Instruction
00001010 (0A H)
User Data
00001001 (09 H)
Supervisor Instruction
00001011 (0B H)
Supervisor Data
3.4.2.6. ASI
In addition to the 32 bits of address output by the processor, an additional eight bits of Address Space Identifier (ASI)
is also sent to system memory during a memory access. These ASI bits control access to 256 32-bit address spaces,
which may or may not overlap depending upon the designer’s implementation. The SPARC architecture defines four
ASI values for user instructions, user data, supervisor instructions, and supervisor data (see Table 6 ). These four ASI
values all map to the same 32–bit address space, and are used to implement access–level protection. ASI values are
commonly used to identify user/supervisor accesses, to identify special protected memory accesses such as boot
PROM, and to access resources such as TSC693E control registers, TLB entries, cache tag entries, etc...
The ASI value is supplied by the TSC691E for each instruction fetch and each data access encountered. The TSC690
family assigns a number of these ASI values to the TSC693E and a number are reserved for future assignment.
Nevertheless, nearly 80 are left unassigned for use by the system.
3.4.3. Instruction Types
TSC691E instructions fall into six functional categories: load/store, arithmetic/logical/shift, control transfer,
read/write control register, floating-point-operate/coprocessor-operate, and miscellaneous. For complete information
on each instruction, see Chapter 6 of the TEMIC SPARC RISC USER’S GUIDE.
3.4.3.1. Load/Store
Load and store instructions (see Table 7 ) move bytes, halfwords, words, and doublewords between the
byte-addressable main memory and a register in either the IU, FPU, or CP. They are the only instructions that access
data memory. For floating-point and coprocessor loads and stores, the TSC691E generates the memory address and
the FPU or CP receives or supplies the data.
The TSC691E implements a hardware-interlocked delay when an instruction immediately following a load tries to read
the register being loaded. The data will be supplied, but only after a one-cycle delay.
Load and store instructions use two-register, register-plus-immediate, and immediate addressing modes. In addition
to the 32-bit address, the TSC691E also generates an eight-bit address space identifier.
3.4.3.1.1. ASI
The Address Space Identifier (ASI) is used by the external system to ascertain which of the 256 available address spaces
to access for the load or store being executed. Access to these alternate spaces can be gained directly by using the “load
from alternate space” and “store to alternate space” instructions. These instructions use two-register addressing and
the asi field in instruction format 3. The address space specified in the asi field overrides the automatic ASI assignment
made by the processor, giving access to such resources as system control registers that are invisible to the user. Because
the ASI is intended for use by the system operating software, the alternate space instructions are privileged and can
only be executed in supervisor mode.
22
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Table 7. Load/Store Instructions
Name
Operation
Cycles
LDSB
(LDSBA*)
Load Signed Byte
(from Alternate Space)
2
LDSH
(LDSHA*)
Load Signed Halfword
(from Alternate Space)
2
LDUB
(LDUBA*)
Load Unsigned Byte
(from Alternate Space)
2
LDUH
(LDUHA*)
Load Unsigned Halfword
(from Alternate Space)
2
LD
(LDA*)
Load Word
(from Alternate Space)
2
LDD
(LDDA*)
Load Doubleword
(from Alternate Space)
3
LDF
Load Floating–Point
2
LDDF
Load Double Floating–Point
3
LDFSR
Load Floating–Point Status
2
LDC
Load Coprocessor
2
LDDC
Load Double Coprocessor
3
LDCSR
Load Coprocessor Status Register
2
STB
(STBA*)
Store Byte
(into Alternate Space)
3
STH
(STHA*)
Store Halfword
(into Alternate Space)
3
ST
(STA*)
Store Word
(into Alternate Space)
3
STD
(STDA*)
Store Doubleword
(into Alternate Space)
4
STF
Store Floating–Point
3
STDF
Store Double Floating–Point
4
STFSR
Store Floating–Point Status Register
3
STDFQ*
Store Double Floating–Point Queue
4
STC
Store Coprocessor
3
STDC
Store Double Coprocessor
4
STCSR
Store Coprocessor State Register
3
STDCQ*
Store Double Coprocessor Queue
4
LDSTUB
(LDSTUBA*)
Atomic Load–Store Unsigned Byte
(in Alternate Space)
4
SWAP
(SWAPA*)
Swap r Register with Memory
(in Alternate Space)
4
* denotes supervisor instruction
3.4.3.1.2. Multiprocessing Instructions
In addition to alternate address spaces, the TSC691E provides two uninterruptible instructions, SWAP and LDSTUB
(atomic load and store unsigned byte), to support tightly coupled multiprocessing.
The SWAP instruction exchanges the contents of an r register with a word from a memory location without allowing
asynchronous traps or other memory accesses during the exchange.
The LDSTUB instruction reads a byte from memory into an r register and then overwrites the memory byte to all ones.
As with SWAP, LDSTUB prevents asynchronous traps and other memory accesses during its execution. LDSTUB is
used to construct semaphores.
MATRA MHS
Rev. H (02 Dec. 96)
23
TSC691E
Multiple processors attempting to simultaneously execute SWAP or LDSTUB to the same memory location are
guaranteed that the competing instructions will execute in serial order.
3.4.3.2. Arithmetic/Logical/Shift
This class of instructions performs a computation on two source operands and writes the result into a destination register
(r[rd]). One of the source operands is always a register, r[rs1], and the other depends on the state of the instruction’s
“i” (immediate) bit. If i = 0, the second operand is register r[rs2]. If i = 1, the operand is the 13-bit, sign-extended
constant in the instruction’s simm13 field. SETHI [1] is a special case because it is a single–operand instruction.
Table 8. Arithmetic/Logical/Shift Instructions
Name
Operation
Cycles
ADD
(ADDcc)
Add
(and modify icc)
1
ADDX
(ADDXcc)
Add with Carry
(and modify icc)
1
TADDcc
(TADDccTV)
Tagged Add and modify icc
(and Trap on oVerflow)
1
SUB
(SUBcc)
Subtract
(and modify icc)
1
SUBX
(SUBXcc)
Subtract with Carry
(and modify icc)
1
TSUBcc
(TSUBccTV)
Tagged Subtract and modify icc
(and Trap on oVerflow)
1
MULScc
Multiply Step and modify icc
1
AND
(ANDcc)
And
(and modify icc)
1
ANDN
(ANDNcc)
And Not
(and modify icc)
1
OR
(ORcc)
Inclusive Or
(and modify icc)
1
ORN
(ORNcc)
Inclusive Or Not
(and modify icc)
1
XOR
(XORcc)
Exclusive Or
(and modify icc)
1
XNOR
(XNORcc)
Exclusive Nor
(and modify icc)
1
SLL
Shift Left Logical
1
SRL
Shift Right Logical
1
SRA
Shift Right Arithmetic
1
SETHI [1]
Set High 22 Bits of r Register
1
For most arithmetic and logical instructions, there is both a version that modifies the integer condition codes and one
that doesn’t (see Table 8 ).
Shift instructions shift left or right by a distance specified in either a register or an immediate value in the instruction.
The multiply step instruction, MULScc, is used to generate the signed or unsigned 64-bit product of two 32-bit integers.
For more information on MULScc, refer to its definition in SPARC V7.0 Instruction Set.
Note 1 : See chapter 4.2 for application of this instruction in Program Flow Control.
3.4.3.2.1. Register r[0]
Because register r[0] reads as a 0 and discards any result written to it as a destination, it can be used with some
instructions to create syntactically familiar pseudoinstructions. For example, an integer COMPARE instruction is
created using the SUBcc (subtract and set condition codes) with r[0] as its destination [1]. A TEST instruction uses
SUBcc with r[0] as both the destination and one of the sources. A register-to-register MOVE is accomplished using
an ADD or OR instruction with r[0] as one of the source registers. A negation is done with SUB and r[0] as one source.
If the assembler being used supports pseudoinstructions, it translates the pseudoinstruction into the equivalent
instruction in the native assembly language. Refer to your assembly language manual for details.
Note:
Refer to Program Flow Control for more information. (see 4.2, page 114)
24
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
3.4.3.2.2. SETHI
SETHI is a special instruction that can be combined with another arithmetic instruction (such as an OR immediate)
to construct a 32-bit constant. SETHI loads a 22-bit immediate value into the upper 22 bits of the destination register
and clears the lower 10 bits. The arithmetic immediate instruction which follows is used to load the lower 10 bits. Note
that the 13-bit immediate value gives a 3 bit overlap with the 22-bit SETHI value. SETHI can also be combined with
a load or store instruction to construct a 32-bit memory address.
TAGGED
DATA
WORD
0 0
2 1 0
WORD
x x
2 1 0
31
OTHER
31
At least one bit
must be non–zero.
Figure 18. Tagged Data Example
SETHI can also be used in Program Flow Control to compare the precomputed checksum given as a special SETHI
instruction (SETHI 0,%SUM) with the checksum. This special SETHI instruction can be inserted after every branch,
call, and before every branch-in point.
3.4.3.2.3. Tagged Arithmetic
The tagged arithmetic instructions are useful for languages that employ tags, such as LISP, Smalltalk, or Prolog. For
efficient support of such languages, the SPARC architecture defines tagged data as a data type. Tagged data are assumed
to be 30 bits wide with the tag bits (the least two significant bits) set to zero (see Figure 18 ). A tagged add (TADDcc)
or subtract (TSUBcc) will set the overflow bit if either of the operands has a nonzero tag or if a normal overflow occurs.
Tagged add or subtract instructions are normally followed by a conditional branch. If the overflow bit is set during a
tagged add or subtract operation, control is commonly transferred to a routine that checks the operand types. In order
to expedite this software construct, the SPARC architecture provides two trap on overflow instructions: TADDccTV
and TSUBccTV, which automatically trap if the overflow bit is set during their execution.
3.4.3.3. Control Transfer
Control transfer instructions are those that change the values of the PC and nPC. These include conditional branches
(Bicc, FBfcc, CBccc), a call (CALL), a jump (JMPL), conditional traps (Ticc), and a return from trap (RETT). Also
included are the SAVE and RESTORE instructions, which don’t transfer control but are used to save or restore windows
during a call to a new procedure or a return to a calling procedure (see Table 9 ).
In the TSC691E, control transfer is usually delayed so that the instruction immediately following the control-transfer
instruction (called the delay instruction) can be executed before control transfers to the target address. The delay
instruction is always fetched. However, the annul or a bit in conditional branch instructions can cause the instruction
to be annulled (i.e., prevent execution) if the branch is not taken (or always annulled in the case of BA, FBA, and CBA).
If a branch is taken, the delay instruction is always executed (except for BA, FBA, and CBA, see Section 3.4.3.4.3).
Table 10 shows the characteristics of each control transfer type.
Program Counter Relative
PC-relative addressing computes the target address by adding a displacement to the program counter. See Section
3.4.2.
Register-Indirect
Register-indirect addressing computes the target address as either r[rs1] + r[rs2] if i = 0, or r[rs1] + simm13 if i = 1.
See Section 3.4.2.
Delayed
A control-transfer instruction is delayed if it transfers control to the target address after a one-instruction delay. See
Section 3.4.3.4.
Annul Bit
In an instruction with an annul bit, the delay instruction that follows may be annulled. See Section 3.4.3.4.3.
MATRA MHS
Rev. H (02 Dec. 96)
25
TSC691E
3.4.3.3.1. Branching and the Condition Codes
The condition code bits in the icc, fcc, and ccc fields, are located (respectively) in the PSR (Processor State Register),
FSR (Floating-point State Register), and CSR (Coprocessor State Register). The integer condition code bits are
modified by arithmetic and logical instructions whose names end with the letters cc, or they may be written directly
with WRPSR. The floating-point condition codes are modified by the floating-point compare instructions, FCMP and
FCMPE, or directly with the STFSR instruction. Modification of the coprocessor condition codes is done directly with
STCSR or by operations defined by the particular coprocessor implementation.
Except for BA (Branch Always) and BN (Branch Never), a Bicc instruction evaluates the integer condition codes as
specified in the cond field. If the tested condition evaluates as true, the branch is taken, causing a PC-relative delayed
transfer to the address [(PC + 4) + sign extnd(disp22)]. If the evaluation result is false, the branch is not taken. For BA
and BN, there is no evaluation; the result is simply forced to true for BA and false for BN.
Table 9. Control Transfer Instructions
Name
Operation
Cycles
SAVE
SAVE caller’s window
1
RESTORE
RESTORE caller’s window
1
Bicc
Branch on integer condition codes
1*
FBfcc
Branch on floating–point condition codes
1*
CBccc
Branch on coprocessor condition codes
1*
CALL
Call
1*
JMPL
JuMP and Link
2*
RETT
RETurn from Trap
2*
Ticc
Trap on integer condition codes
1 (4 if taken)
* assumes delay slot is filled with a useful instruction
Table 10. Control Transfer Instruction Characteristics
Instructions
Addressing Mode
Delayed
Annul Bit
Conditional Branch
Program Counter Relative
yes
yes
Call
Program Counter Relative
yes
yes
Jump
Register Indirect
yes
no
Return
Register Indirect
yes
no
Trap
Register Indirect
no
no
If the branch is not taken, then the annul bit is checked. If the “a” bit is set, the delay instruction is annulled. If “a” is
not set, the delay instruction is executed. If the branch is taken, the annul bit is ignored and the delay instruction is
executed. For more information on delayed control transfer and the annul bit, see Section 3.4.3.4.
BN, of course, never branches, and therefore executes like a NOP (but is not recommended as a NOP instruction).
However, as far as the annul bit is concerned, BN acts like a normal branch instruction, annulling the delay instruction
if a = 1 and executing it if a = 0.
BA, on the other hand, always branches, so the annul bit would normally be ignored. But for BA, FBA, and CBA, the
effect of the annul bit is changed. See Section 3.4.3.4.3 for details.
As illustrated in Table 11 , Bicc and Ticc instructions test for the same conditions and use the same cond field codes
during their evaluations.
An FBfcc instruction operates in the same way as a Bicc, except it tests the FCC<1:0> signals output by the
floating–point unit (see Table 12 ). The FCC<1:0> signals are floating–point condition codes which are set by
26
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
executing a floating–point compare instruction. A CBccc instruction behaves in the same manner as a FBfcc, except
it tests the CCC<1:0> signals supplied by the coprocessor (see Table 13 ). Both FBN and CBN behave in the same way
as BN.
3.4.3.3.2. Trap Instructions
The “Trap on integer condition codes” (Ticc) instruction evaluates the condition codes specified by its cond (condition)
field. If the result is true, a trap is immediately taken (no delay instruction). If the condition codes evaluate to false,
Ticc executes as a NOP.
Once the Ticc is taken, it identifies which software trap type caused it by writing its trap number + 128 (the offset for
trap instructions) into the tt field of the Trap Base Register (TBR), as illustrated in Figure 19 . The trap number is the
least significant seven bits of either “r[rs1] + r[rs2]” if the i field is zero, or “r[rs1] + sign extnd(simm13)” if the i field
is one. The processor then disables traps (ET=0), saves the state of S into PS, decrements the CWP, saves PC and nPC
into the locals r[17] and r[18] (respectively) of the new window, enters supervisor mode (S=1), and writes the trap base
register to the PC and TBR + 4 to nPC.
Table 11. Bicc and Ticc Condition Codes
Cond.
0000
0001
0010
0011
0100
0101
0110
0111
Test
Never
Equal to
Less than or equal
Less than
Less than or equal to, unsigned
Carry set (less than, unsigned)
Negative
Overflow set
Cond.
Test
1000
1001
1010
1011
1100
1101
1110
1111
Always
Not equal to
Greater than
Greater than or equal to
Greater than, unsigned
Carry clear (greater than or equal to, unsigned)
Positive
Overflow clear
Table 12. FBfcc Condition Codes
Cond.
0000
0001
0010
0011
0100
0101
0110
0111
Test
Cond.
Never
Not equal to
Less than or greater than
Unordered or less than
Less than
Unordered or greater than
Greater than
Unordered
1000
1001
1010
1011
1100
1101
1110
1111
Test
Always
Equal to
Unordered or equal to
Greater than or equal to
Unordered or greater than or equal to
Less than or equal to
Unordered or less than or equal to
Ordered
Table 13. CBccc Condition Codes
Opcode
Cond.
CBN
CB123
CB12
CB13
CB1
CB23
CB2
CB3
0000
0001
0010
0011
0100
0101
0110
0111
MATRA MHS
Rev. H (02 Dec. 96)
CCC[1:0] Test
Never
1 or 2 or 3
1 or 2
1 or 3
1
2 or 3
2
3
Opcode
Cond.
CBA
CB0
CB03
CB02
CB023
CB01
CB013
CB012
1000
1001
1010
1011
1100
1101
1110
1111
CCC[1:0] Test
Always
0
0 or 3
0 or 2
0 or 2 or 3
0 or 1
0 or 1 or 3
0 or 1 or 2
27
TSC691E
Trap Base Register
Trap Type (tt) 0 0 0 0
Trap Base Address (TBA)
31
12
11
4
3
128
31
0
7 6
7–Bit operand
Register Source 1
31
0
13
Sign Extension
+
<6:0>
Register Source 2
<7:0>
tt field of Trap Base Register
0
7–Bit operand
7 6
31
tt field of Trap Base Register
128
7 6
Register Source 1
<7:0>
13-Bit Immediate
i bit of Ticc instruction = 1
31
+
0
+
<6:0>
+
7–Bit operand
i bit of Ticc instruction = 0
Figure 19. Ticc Trap Address Generation
Ticc can be used to implement kernel calls, breakpointing, and tracing. It can also be used for run-time checks, such
as out-of-range array indices, integer overflow, etc.
Return from a trap is accomplished using the delayed control transfer couple, JMPL, RETT. RETT first increments
the CWP by one, calculates the return address (using register-indirect addressing), and then checks for a number of
trap conditions before it allows a return. An illegal_instruction trap is generated if traps are enabled (ET=1) when RETT
is executed. If ET=0, RETT checks for other trap conditions and will generate a reset trap and enter error mode for
the following conditions: S=0, the new CWP would cause a window underflow, or the return address is not word
aligned. If none of these conditions exist, RETT enables traps (ET=1), restores the previous supervisor state to the S
bit, and writes the target address into the nPC.
3.4.3.3.3. Calls and Returns
Calling a subroutine or procedure can be done in one of two ways. A CALL instruction computes its target address
using a PC-relative displacement of 30-bits. The JuMP and Link (JMPL) instruction uses register-indirect addressing
(the sum of two registers or the sum of a register and a 13-bit signed immediate value) to compute its target address.
Either instruction allows control transfer to any arbitrary instruction address.
Control transfer to a procedure that requires its own register window is done with either a CALL or JMPL instruction
and a SAVE instruction. A procedure that does not need a new window, a so-called “leaf” routine, is invoked with only
the CALL or JMPL.
The CALL instruction stores its return address (the current PC) into outs register r[15]. When the new window is
activated, this becomes ins register r[31] (see Figure 5 ). The JMPL instruction stores its return address (the contents
of PC, which is the Link) into the r register specified in the destination field, rd.
The primary purpose of the SAVE instruction is to “save” the caller’s window by decrementing the Current Window
Pointer (CWP) by one, thereby activating the next window and making the current window into the previous window.
SAVE also performs a normal ADD, using source registers from the caller’s window, but writing the result into a
destination register in the new window. This can be used to set a new stack pointer from the previous one (see Section
3.3.1.1.1).
Return from a procedure requiring its own window is done with a RESTORE and a JMPL instruction. A leaf procedure
returns by executing a JMPL only. The target address for the return is normally that of the instruction following the
CALL’s or JMPL’s delay instruction; that is, the return address + 8. The RESTORE instruction restores the caller’s
window by incrementing the CWP by one, causing the previous window to become the current window. As with SAVE,
RESTORE performs an ADD using source registers from the called (new) window and writing the result into the calling
(previous) window.
Both SAVE and RESTORE compare the new CWP against the Window Invalid Mask (WIM) to check for window
overflow or underflow. They may also be used to atomically change the CWP while establishing a new memory stack
pointer in an r register.
28
MATRA MHS
Rev. H (02 Dec. 96)
0
TSC691E
3.4.3.4. Delayed Control Transfer
Traditional architectures usually execute the target instruction of a control transfer immediately after the control
transfer instruction. However, in a pipelined RISC architecture, this type of transfer would require flushing the
instruction that follows the control transfer instruction. To avoid creating a hole or bubble in the pipeline, the TSC691E
delays execution of the target instruction until the instruction following the control transfer instruction is executed. The
instruction in this delay slot is called the delay instruction.
Table 14. Delayed Control Transfer Instruction Example
PC
nPC
8
12
16
12
16
40
40
44
Instruction
Non-control transfer
Control transfer (target = 40)
Non-control transfer (delay instruction)
(Transfers control to 40)
...
Table 15. Effect of Annul Bit Reset (a=0)
PC
nPC
8
12
16
20
12
16
20
24
Instruction
Non-control transfer
Bicc (a = 0) 40
Delay slot instruction
...
Action
Executed
Not Taken
Executed
Executed
Table 16. Effect of Annul Bit Reset (a=1)
PC
nPC
8
12
16
20
12
16
20
24
Instruction
Non-control transfer
Bicc (a = 1) 40
Delay slot instruction (annuled)
Action
Executed
Not Taken
Not Executed
Executed
3.4.3.4.1. PC and nPC
The Program Counter (PC) contains the address of the instruction currently being executed by the TSC691E, and the
next Program Counter (nPC) holds the address (PC + 4) of the next instruction to be executed (assuming a control
transfer or a trap does not occur).
Most instructions end by copying the contents of the nPC into the PC and then they either increment nPC by four or
write a computed control transfer target address into nPC. At this point, the PC points to the instruction that is about
to begin execution and the nPC points to the instruction that will be executed after that, i.e. the second instruction after
the currently executing instruction. It is the existence of the nPC that allows the execution of the delay instruction
before transfer of control to the target instruction.
3.4.3.4.2. Delay Instruction
The instruction pointed to by the nPC when the PC is pointing to a delayed-control-transfer instruction is called the
delay instruction. Normally, this is the next sequential instruction in the code stream. However, if the instruction that
preceded the delayed control transfer was itself a delayed control transfer, the target of the preceding control transfer
becomes the delay instruction (that’s where the nPC will point). For more on delayed control transfer couples, see
Section 3.4.3.4.4.
Table 14 shows the order of execution for a simple (not back-to-back) delayed control transfer. The order of execution
is 8, 12, 16, 40. If the delayed-control-transfer instruction were not taken, the order would be 8, 12, 16, 20.
3.4.3.4.3. Annul Bit
The a (annul) bit is only available on conditional branch instructions (Bicc, FBfcc, and CBccc), where it changes the
behavior of the delay instruction. If a is set on a conditional branch instruction (except BA, FBA, and CBA) and the
branch is not taken, the delay instruction is annulled (not executed). An annulled instruction has no effect on the state
of the TSC691E nor can a trap occur during an annulled instruction. If the branch is taken, the a bit is ignored and the
delay instruction is executed. Table 15 and Table 16 show the effect of the annul bit when it is reset or set.
MATRA MHS
Rev. H (02 Dec. 96)
29
TSC691E
The “branch always” instructions (BA, FBA, and CBA) are a special case. If the a bit is set in these instructions, the
delay instruction is annulled, even though the branch is taken. Effectively, this gives a “traditional” non-delayed
branch. When a = 0 in a “branch always” instruction, it behaves the same as any other conditional branch; the delay
instruction is executed. Figure 20 displays the effect the a bit has on any branch for either the set or reset state.
Table 17 summarizes the effect the annul bit has on the execution of delay instructions.
Table 17. Effect of Annul Bit on Delay Instruction
a bit
Type of branch
Delay instruction executed?
a=1
Always
No
Conditional, taken
Yes
Conditional, not taken
No
Always
Yes
Conditional, taken
Yes
Conditional, not taken
Yes
a=0
ANNUL = 0
ANNUL = 1
Code
Code
Control Transfer Inst.
Taken
Conditional
Delay Inst.
Branch
Always
Control Transfer Inst.
Taken
Conditional
Delay Inst.
Untaken
Conditional
Untaken
Conditional
Figure 20. Delayed Control Transfer
3.4.3.4.4. Delayed Control Transfer Couples
The occurrence of two back-to-back, delayed control transfer instructions is called a delayed control transfer couple,
which the processor handles differently from a simple control transfer. An instruction sequence containing a delayed
control transfer couple is shown in Table 18 , and the order of execution for the six different cases of back-to-back,
delayed control transfer instructions is shown in Table 19 .
The delay slot instruction for a delayed control transfer instruction is the instruction fetched after the delayed control
transfer instruction. For most cases, this instruction is located immediately in the code listing after the delayed control
transfer instruction. However, in the case of a delayed control transfer couple, the target instruction of the first delayed
control transfer instruction is the delay slot instruction for the second delayed control transfer instruction, since that
target instruction is the next instruction to be fetched. The delay slot instruction for the second delayed control transfer
instruction is the next instruction loaded into the instruction pipeline after the second delayed control transfer
instruction.
In the following tables, “delayed control transfer instruction” is abbreviated to “DCTI”. A “Non-DCTI” may be either
a non-control transfer instruction or a control transfer that is not delayed (i.e., a Ticc). Where the annul bit is not
indicated, it may be either 0 or 1.
30
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Case 1 of Table 19 includes the “JMPL, RETT” couple, which is the normal method of returning from a trap handler.
The JMPL, RETT couple ensures correct values of PC and nPC are restored upon exiting the trap routine, even in the
case of a trap caused by a delay slot instruction (see Section 3.4.3.4.2). The case of a trap caused by a delay slot
instruction is one where the nPC will not be PC + 4, thus requiring both PC and nPC to be restored. The JMPL, RETT
couple allows the choice of re–executing the trapped instruction or executing the instruction following the trap
occurrence. Refer to the RETT entry in SPARC V7.0 Instruction Set for further information.
Table 18. Delayed Control Transfer Couple Instruction Sequence
Address
Instruction
8:
12:
16:
20:
24:
...
40:
44:
...
60:
64:
...
Non DCTI
DCTI
DCTI
Non DCTI
...
...
Non DCTI
...
...
Non DCTI
...
...
Target
40
60
Table 19. Execution of Delayed Control Transfer Couples
Case
1
2
3
4
5
6
DCTI at Location 12
DCTI Unconditional
DCTI Unconditional
DCTI Unconditional
DCTI Unconditional
B*A(a = 1)
B*cc
B*A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B*cc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DCTI Uncond. . . . . . . . . . . . . . . . . . . . . . .
DCTI Taken . . . . . . . . . . . . . . . . . . . . . . . .
DCTI at Location 16
DCTI Taken
B*cc(a = 0) Untaken
B*cc(a = 1) Untaken
B*A(a = 1)
any CTI
DCTI
Order of Execution
12, 16, 40, 60, 64, ...
12, 16, 40, 44, ...
12, 16, 44, 48, ...(40 annuled)
12, 16, 60, 64, ...(40 annuled)
12, 40, 44, ...(40 annuled)
Not Supported
BA, FBA, or CBA
Bicc, FBicc, or CBicc (except B*A)
CALL, JMPL, RETT, or B*A(a=0)
CALL, JMPL, RETT, B*cc taken, or B*A(a=0)
Cases 1-5 described in Table 19 are illustrated in Figure 21 . In case 1, the first DCTI is fetched at address 12 and the
target address is calculated while the delay slot instruction is fetched. The delay slot instruction for the first DCTI
(located at address 16) is another DCTI, which also has a delay slot. The target address of the first DCTI has been
calculated by the time the first delay slot instruction has been fetched, and the target instruction is fetched at address
40. The target instruction is the instruction located in the instruction pipeline after the second DCTI, and therefore it
is the delay slot instruction for the second DCTI. The target instruction for the second DCTI (address 60) is fetched
after the delay slot instruction for the second DCTI (which is also the target address for the first DCTI) has been fetched.
Case 2 differs from case 1 in that the second DCTI is conditional, and is not taken. In case 2, the instruction at address
40 (target for DCTI #1) is the delay slot instruction for the second DCTI. Since the second DCTI does not cause a
branch, the instruction fetch continues to address 44.
Case 3 is an interesting case in which the target instruction of the first DCTI is annulled by the second DCTI. This causes
the instruction at address 40 to be annulled. Since the second DCTI is an untaken conditional branch, instruction fetch
continues after the annulled target instruction (address 44).
Case 4 illustrates a DCTI followed by a branch always instruction with the annul bit set. This causes the target
instruction of the first DCTI (address 40) to be annulled, and program control is transferred to the target of the second
DCTI at address 60.
Case 5 illustrates the case where the second DCTI is annulled by the annul bit of the first DCTI. The second DCTI,
since it is annulled, has no effect on instruction fetch. This case is identical to the case of any other annulled delay slot
instruction.
When the first instruction of a delayed control transfer couple is a conditional branch, control transfer is undefined (case
6). If such a couple is executed, the location where execution continues is within the same address space but is otherwise
undefined. Execution of this sequence does not change any other aspect of the processor state.
MATRA MHS
Rev. H (02 Dec. 96)
31
TSC691E
Inst.
Address
Inst.
Address
12H
Case 1
12H
DCT Inst. 1
16H
Delay Slot #1
DCT Inst. 2
40H
DCT Inst. 1
Delay Slot #1
B*cc (untaken)
a=0
16H
Delay Slot #2
DCT #1 Target
40H
Inst.
Address
12H
Case 2
16H
Case 3
DCT Inst. 1
Delay Slot #1
B*cc (untaken)
a=1
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ
Delay Slot #2
Delay Slot #2
DCT #1 Target
40H DCT #1 Target
annulled by DCTI #2
44H
44H
Next Inst.
Next Inst.
60H DCT #2 Target
64H
Next Inst.
Inst.
Address
12H
16H
Case 4
DCT Inst. 1
Delay Slot #1
B*A (a=1)
ÏÏÏÏÏÏ
ÏÏÏÏÏÏ
ÏÏÏÏÏÏ
Inst.
Address
12H
Case 5
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ
ÏÏÏÏÏÏÏ
16H
B*A (a=1)
Delay Slot #2
DCT Inst. 2
annulled by DCTI #1
Delay Slot #2
40H
DCT #1 Target
annulled by DCTI #2
40H DCT #1 Target
44H
Next Inst.
60H DCT #2 Target
64H
Next Inst.
Figure 21. Delayed Control Transfer Couples
32
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 20. Read/Write Control Register Instructions
Name
Operation
Cycles
RDY
Read Y Register
1
RDPSR*
Read Processor State Register
1
RDWIM*
Read Window Invalid Mask
1
RDTBR*
Read Trap Base Register
1
WRY
Write Y Register
1
WRPSR*
Write Processor State Register
1
WRWIM*
Write Window Invalid Mask
1
WRTBR*
Write Trap Base Register
1
* denotes supervisor instruction
Table 21. Floating–Point–Operate and Coprocessor–Operate Instructions
Name
Operation
Cycles
FPop
Floating–Point Operations
1 to launch
FPop
Coprocessor Operations
1 to launch
Table 22. Miscellaneous Instructions
Name
Operation
Cycles
UNIMP
Unimplemented Instruction
1
IFLUSH
Instruction Cache Flush
1
3.4.3.5. Read/Write Control Registers
This class of instruction reads or writes the contents of the various control registers (see Table 20 ). The source (read)
or destination (write) is implied by the instruction name. Read/write instructions are provided for the PSR, WIM, TBR,
FSR, CSR, and the Y register. Reads and writes to the PSR, WIM, and TBR are privileged and are available in
supervisor mode only.
3.4.3.6. Floating-Point-Operate and Coprocessor-Operate
Floating-point calculations are accomplished with floating-point-operate instructions (FPops), which are
register-to-register instructions that compute some result as a function of one or two source operands (see Table 21 ).
The result is always placed in a destination register (i.e., source operands are not overwritten). The source and
destination registers are f registers from the FPU’s register file. If no FPU is present, or if the EF bit of the PSR is not
set, executing a floating–point instruction will generate a FP disabled trap.
Coprocessor-operate instructions (FPops) are executed by the attached coprocessor. Coprocessor instructions use the
c registers located in the coprocessor’s register file as source and destination registers. If there is no attached
coprocessor, attempted execution of a coprocessor instruction generates a FP disabled trap.
Floating-point and coprocessor load/store instructions are not operate instructions; they fall under the TSC691E’s load
/store instruction category (see Section 3.4.3.1).
Except for op and op3, which specify the particular floating-point-operate or coprocessor-operate instruction to be
executed, the instruction fields of an FPop or CPop are interpreted by the FPU or coprocessor. Floating-point-operate
instructions execute concurrently with TSC691E instructions. FPops can also execute concurrently with both
TSC691E and FPop instructions if they are designed to do so.
MATRA MHS
Rev. H (02 Dec.96)
33
TSC691E
Because the TSC691E and FPU can execute instructions concurrently, when a floating-point exception occurs, the PC
DOEs contain the address of an FPop instruction, but not the one that caused the exception. However, the front entry
of the floating-point queue contains the offending instruction and its address.
If the coprocessor executes instructions concurrently with the TSC691E, the architecture will support a coprocessor
queue that functions in the same fashion as the floating-point queue.
3.4.3.7. Miscellaneous
Instructions in this category handle special circumstances within the integer unit (see Table 22 ). Execution of the
UNIMP instruction causes an illegal instruction trap, so its execution is normally avoided except as part of a checking
routine. Details of one possible use for UNIMP are given in its definition in SPARC V7.0 Instruction Set.
The IFLUSH instruction is used to flush a word from an internal (to the TSC691E) instruction cache. Current integer
unit implementations (TSC691E) do not incorporate an internal instruction cache, so IFLUSH would normally execute
as a NOP. However, if there is an external instruction cache, IFLUSH causes an illegal instruction trap if the IFT signal
is LOW (see Section 3.5)
3.4.4. Op Codes
This section contains tables that give a complete list of the instruction opcodes, both by functional groups and in
ascending numeric order.
3.4.4.1. Load/Store Instructions
Table 23. Load/Store Instruction Opcodes
Opcodes with Format
Mnemonic
31 30
LD
1 1
29
25
rd
24
19
000000
18
14
rs1
13
i =0
12
5
ignored
i =1
0
rs2
simm13
LDA
1 1
rd
010000
rs1
i =0
asi
rs2
LDC
1 1
rd
110000
rs1
i =0
ignored
rs2
i =1
LDCSR
1 1
rd
110001
rs1
i =0
simm13
ignored
i =1
LDD
1 1
rd
000011
rs1
i =0
rs2
simm13
ignored
i =1
rs2
simm13
LDDA
1 1
rd
010011
rs1
i =0
asi
rs2
LDDC
1 1
rd
110011
rs1
i =0
ignored
rs2
i =1
LDDF
1 1
rd
100011
rs1
i =0
i =1
LDF
1 1
rd
100000
rs1
i =0
i =1
LDFSR
1 1
rd
100001
rs1
i =0
i =1
34
4
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Opcodes with Format
Mnemonic
31 30
LDSB
1 1
29
25
rd
24
19
001001
18
14
rs1
13
i =0
12
5
ignored
i =1
4
0
rs2
simm13
LDSBA
1 1
rd
011001
rs1
i =0
asi
rs2
LDSH
1 1
rd
001010
rs1
i =0
ignored
rs2
i =1
simm13
LDSHA
1 1
rd
011010
rs1
i =0
asi
rs2
LDSTUB
1 1
rd
001101
rs1
i =0
ignored
rs2
i =1
simm13
LDSTUBA
1 1
rd
011101
rs1
i =0
asi
rs2
LDUB
1 1
rd
000001
rs1
i =0
ignored
rs2
i =1
simm13
LDUBA
1 1
rd
010001
rs1
i =0
asi
rs2
LDUH
1 1
rd
000010
rs1
i =0
ignored
rs2
i =1
simm13
LDUHA
1 1
rd
010010
rs1
i =0
asi
rs2
ST
1 1
rd
000100
rs1
i =0
ignored
rs2
i =1
simm13
STA
1 1
rd
010100
rs1
i =0
asi
rs2
STB
1 1
rd
000101
rs1
i =0
ignored
rs2
i =1
simm13
STBA
1 1
rd
010101
rs1
i =0
asi
rs2
STC
1 1
rd
110100
rs1
i =0
ignored
rs2
i =1
STCSR
1 1
rd
110101
rs1
i =0
simm13
ignored
i =1
STD
1 1
rd
000111
rs1
i =0
rs2
simm13
ignored
i =1
rs2
simm13
STDA
1 1
rd
010111
rs1
i =0
asi
rs2
STDC
1 1
rd
110111
rs1
i =0
ignored
rs2
i =1
STDCQ
1 1
rd
110110
rs1
i =0
i =1
STDF
MATRA MHS
Rev. H (02 Dec.96)
1 1
rd
100111
rs1
i =0
simm13
ignored
rs2
simm13
ignored
rs2
35
TSC691E
Opcodes with Format
Mnemonic
31 30
29
24
25
19
18
14
13
12
5
i =1
STDFQ
1 1
100110
rd
rs1
1 1
100100
rd
rs1
i =0
ignored
1 1
100101
rd
rs1
i =0
ignored
1 1
000110
rd
rs1
rs2
simm13
i =0
ignored
i =1
STH
rs2
simm13
i =1
STFSR
0
simm13
i =1
STF
4
rs2
simm13
i =0
ignored
i =1
rs2
simm13
STHA
1 1
rd
010110
rs1
i =0
asi
rs2
SWAP
1 1
rd
001111
rs1
i =0
ignored
rs2
i =1
SWAPA
1 1
011111
rd
rs1
simm13
i =0
asi
rs2
3.4.4.2. Arithmetic/Logical/Shift Instructions
Table 25. Arithmetic/Logical/Shift Instruction Opcodes
Opcodes with Format
Mnemonic
31 30
ADD
1 0
29
25
rd
24
19
000000
18
14
rs1
13
i =0
i =1
ADDcc
1 0
rd
010000
rs1
i =0
i =1
ADDX
1 0
rd
001000
rs1
i =0
i =1
ADDXcc
1 0
rd
011000
rs1
i =0
i =1
AND
1 0
rd
000001
rs1
i =0
i =1
ANDcc
1 0
rd
010001
rs1
i =0
i =1
ANDN
1 0
rd
000101
rs1
i =0
i =1
ANDNcc
36
1 0
rd
010101
rs1
i =0
12
5
4
ignored
0
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Mnemonic
Opcodes with Format
31 30
29
25
24
19
18
14
13
i =1
MULScc
1 0
rd
100100
rs1
i =0
i =1
OR
1 0
rd
000010
rs1
i =0
i =1
ORcc
1 0
rd
010010
rs1
i =0
i =1
ORN
1 0
rd
000110
rs1
i =0
i =1
ORNcc
1 0
rd
010110
rs1
i =0
i =1
SLL
1 0
rd
100101
rs1
i =0
12
5
1 0
rd
100111
rs1
i =0
ignored
1 0
rd
100110
rs1
i =0
ignored
1 0
rd
000100
rs1
i =0
i =1
SUBcc
1 0
rd
010100
rs1
i =0
i =1
SUBX
1 0
rd
001100
rs1
i =0
i =1
SUBXcc
1 0
rd
011100
rs1
i =0
i =1
TADDcc
1 0
rd
100000
rs1
i =0
i =1
TADDccTV
1 0
rd
100010
rs1
i =0
i =1
TSUBcc
1 0
rd
100001
rs1
i =0
i =1
TSUBccTV
1 0
rd
100011
rs1
i =0
i =1
MATRA MHS
Rev. H (02 Dec.96)
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
shcnt
ignored
rs2
shcnt
ignored
i =1
SUB
rs2
simm13
i =1
SRL
0
simm13
i =1
SRA
4
rs2
shcnt
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
37
TSC691E
Mnemonic
Opcodes with Format
31 30
XNOR
29
25
1 0
24
rd
19
18
14
000111
13
12
5
i =0
rs1
1 0
rd
010111
ignored
i =1
XOR
1 0
rd
000011
rs1
i =0
XOR
1 0
rd
000011
rs1
i =1
XORcc
1 0
rd
010011
rs1
i =0
SETHI
29
0 0
25
24 22
rd
rs2
simm13
ignored
rs2
simm13
ignored
i =1
31 30
rs2
simm13
i =0
rs1
0
ignored
i =1
XNORcc
4
rs2
simm13
21
0
100
imm22
3.4.4.3. Control Transfer Instructions
Table 27. Control Transfer Instruction Opcodes
Opcodes with Format
Mnemonic
31 30
JMPL
29
1 0
25
rd
24
19
18
111000
14
13
12
5
i =0
rs1
1 0
rd
111101
ignored
i =1
RETT
1 0
ignored
111001
ignored
i =1
SAVE
1 0
rd
111100
ignored
i =1
29
28 25
24 22
Bicc
0 0
a
cond
010
disp22
CBccc
0 0
a
cond
111
disp22
FBfcc
0 0
a
cond
110
disp22
31 30
29
28 25
24
1 0
I*
cond
21
19
111010
0
18
14
rs1
13
i =0
i =1
CALL
0 1
rs2
simm13
31 30
Ticc
rs2
simm13
i =0
rs1
rs2
simm13
i =0
rs1
rs2
simm13
i =0
rs1
0
ignored
i =1
RESTORE
4
12
5
ignored
4
0
rs2
simm13
disp30
*I = ignored.
38
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 28. Bicc and Ticc Condition Codes
Cond.
Test
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Never
Equal to
Less than or equal to
Less than
Less than or equal to, unsigned
Carry set (less than, unsigned)
Negative
OverFLOW set
Always
Not equal to
Greater than
Greater than or equal to
Greater than, unsigned
Carry clear (greater than or equal, unsigned)
Positive
OverFLOW clear
Table 29. FBfcc Condition Codes
Cond.
Test
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Never
Not equal
Less than or greater to
Unordered or less than
Less than
Unordered or greater than
Greater than
Unordered
Always
Equal
Unordered or equal
Greater than or equal
Unordered or greater than or equal
Less than or equal
Unordered or less than or equal
Ordered
Table 30. CBccc Condition Codes
Opcode
Cond.
CBN
CB123
CB12
CB13
CB1
CB23
CB2
CB3
CBA
CB0
CB03
CB02
CB023
CB01
CB013
CB012
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Test
Never
1 or 2 or 3
1 or 2
1 or 3
1
2 or 3
2
3
Always
0
0 or 3
0 or 2
0 or 2 or 3
0 or 1
0 or 1 or 3
0 or 1 or 2
3.4.4.4. Read/Write Control Register Instructions
MATRA MHS
Rev. H (02 Dec.96)
39
TSC691E
Table 31. Read/Write Control Register Instruction Opcodes
Opcodes with Format
Mnemonic
31 30
29
25
24
19
18
14
13
12
0
RDPSR
1 0
rd
101001
ignored
I*
ignored
RDTBR
1 0
rd
101011
ignored
I*
ignored
RDWIM
1 0
rd
101010
ignored
I*
ignored
RDY
1 0
rd
101000
ignored
I*
ignored
31 30
WRPSR
29
1 0
25
ignored
24
19
18
110001
14
13
12
i =0
rs1
5
1 0
ignored
110011
ignored
i =1
WRWIM
1 0
ignored
110010
ignored
i =1
WRY
1 0
ignored
110000
rs2
simm13
i =0
rs1
rs2
simm13
i =0
rs1
rs2
simm13
i =0
rs1
0
ignored
i =1
WRTBR
4
ignored
i =1
rs2
simm13
*I = ignored.
3.4.4.5. Floating-Point/Coprocessor Instructions
Table 32. Floating–Point /Coprocessor Instruction Opcodes
Opcodes with Format
Mnemonic
31 30
40
29
25
24
19
18
14
13
5
4
0
FPOP1
1 0
rd
110110
rs1
OPC
rs2
FPOP2
1 0
rd
110111
rs1
OPC
rs2
FABSs
1 0
rd
110100
ignored
0 0 0 0 0 1 0 0 1
rs2
FADDs
1 0
rd
110100
rs1
0 0 1 0 0 0 0 0 1
rs2
FADDd
1 0
rd
110100
rs1
0 0 1 0 0 0 0 1 0
rs2
FADDx
1 0
rd
110100
rs1
0 0 1 0 0 0 0 1 1
rs2
FCMPs
1 0
ignored
110101
rs1
0 0 1 0 1 0 0 0 1
rs2
FCMPd
1 0
ignored
110101
rs1
0 0 1 0 1 0 0 1 0
rs2
FCMPx
1 0
ignored
110101
rs1
0 0 1 0 1 0 0 1 1
rs2
FCMPEs
1 0
ignored
110101
rs1
0 0 1 0 1 0 1 0 1
rs2
FCMPEd
1 0
ignored
110101
rs1
0 0 1 0 1 0 1 1 0
rs2
FCMPEx
1 0
ignored
110101
rs1
0 0 1 0 1 0 1 1 1
rs2
FDIVs
1 0
rd
110100
rs1
0 0 1 0 0 1 1 0 1
rs2
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Mnemonic
Opcodes with Format
31 30
29
25
24
19
18
14
13
5
4
0
FDIVd
1 0
rd
110100
rs1
0 0 1 0 0 1 1 1 0
rs2
FDIVx
1 0
rd
110100
rs1
0 0 1 0 0 1 1 1 1
rs2
FMOVs
1 0
rd
110100
ignored
0 0 0 0 0 0 0 0 1
rs2
FMULs
1 0
rd
110100
rs1
0 0 1 0 0 1 0 0 1
rs2
FMULd
1 0
rd
110100
rs1
0 0 1 0 0 1 0 1 0
rs2
FMULx
1 0
rd
110100
rs1
0 0 1 0 0 1 0 1 1
rs2
FNEGs
1 0
rd
110100
ignored
0 0 0 0 0 0 1 0 1
rs2
FSQRTs
1 0
rd
110100
ignored
0 0 0 1 0 1 0 0 1
rs2
FSQRTd
1 0
rd
110100
ignored
0 0 0 1 0 1 0 1 0
rs2
FSQRTx
1 0
rd
110100
ignored
0 0 0 1 0 1 0 1 1
rs2
FSUBs
1 0
rd
110100
rs1
0 0 1 0 0 0 1 0 1
rs2
FSUBd
1 0
rd
110100
rs1
0 0 1 0 0 0 1 1 0
rs2
FSUBx
1 0
rd
110100
rs1
0 0 1 0 0 0 1 1 1
rs2
FdTOi
1 0
rd
110100
ignored
0 1 1 0 1 0 0 1 0
rs2
FdTOs
1 0
rd
110100
ignored
0 1 1 0 0 0 1 1 0
rs2
FdTOx
1 0
rd
110100
ignored
0 1 1 0 0 1 1 1 0
rs2
FiTOd
1 0
rd
110100
ignored
0 1 1 0 0 1 0 0 0
rs2
FiTOs
1 0
rd
110100
ignored
0 1 1 0 0 0 1 0 0
rs2
FiTOx
1 0
rd
110100
ignored
0 1 1 0 0 1 1 0 0
rs2
FsTOd
1 0
rd
110100
ignored
0 1 1 0 0 1 0 0 1
rs2
FsTOi
1 0
rd
110100
ignored
0 1 1 0 1 0 0 0 1
rs2
FsTOx
1 0
rd
110100
ignored
0 1 1 0 0 1 1 0 1
rs2
FxTOi
1 0
rd
110100
ignored
0 1 1 0 1 0 0 1 1
rs2
FxTOs
1 0
rd
110100
ignored
0 1 1 0 0 0 1 1 1
rs2
FxTOd
1 0
rd
110100
ignored
0 1 1 0 0 1 0 1 1
rs2
3.4.4.6. Miscellaneous Instructions
Table 33. Miscellaneous Instruction Opcodes
Opcodes with Format
Mnemonic
31 30
IFLUSH
1 0
29
25
ignored
24
19
111011
18
14
rs1
13
12
i =0
ignored
i =1
UNIMP
MATRA MHS
Rev. H (02 Dec.96)
0 0
ignored
000
5
4
0
rs2
simm13
const22
41
TSC691E
3.4.4.7. Opcodes In Ascending Numeric Order
Table 34. Instruction Opcode Numeric Listing
Opcodes with Format
Mnemonic
31 30
29
UNIMP
0 0
Bicc
0 0
SETHI
0 0
FBfcc
0 0
a
CBccc
0 0
a
CALL
0 1
ADD
1 0
25
ignored
a
24 22 21 19
18
14
13
000
const22
010
disp22
100
imm22
cond
110
disp22
cond
111
disp22
cond
rd
1 0
rd
000000
rs1
i =0
rd
000001
rs1
i =0
i =1
OR
1 0
rd
000010
rs1
i =0
i =1
XOR
1 0
rd
000011
rs1
i =0
i =1
SUB
1 0
rd
000100
rs1
i =0
i =1
ANDN
1 0
rd
000101
rs1
i =0
i =1
ORN
1 0
rd
000110
rs1
i =0
i =1
XNOR
1 0
rd
000111
rs1
i =0
i =1
ADDX
1 0
rd
001000
rs1
i =0
i =1
SUBX
1 0
rd
001100
rs1
i =0
i =1
ADDcc
1 0
rd
010000
rs1
i =0
i =1
ANDcc
1 0
rd
010001
rs1
i =0
i =1
42
5
4
0
disp30
i =1
AND
12
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 35. Instruction Opcode Numeric Listing (continued)
Opcodes with Format
Mnemonic
31 30
ORcc
1 0
29
25
rd
24 22 21 19
010010
18
14
rs1
13
i =0
i =1
XORcc
1 0
rd
010011
rs1
i =0
i =1
SUBcc
1 0
rd
010100
rs1
i =0
i =1
ANDNcc
1 0
rd
010101
rs1
i =0
i =1
ORNcc
1 0
rd
010110
rs1
i =0
i =1
XNORcc
1 0
rd
010111
rs1
i =0
i =1
ADDXcc
1 0
rd
011000
rs1
i =0
i =1
SUBXcc
1 0
rd
011100
rs1
i =0
i =1
TADDcc
1 0
rd
100000
rs1
i =0
i =1
TSUBcc
1 0
rd
100001
rs1
i =0
i =1
TADDccTV
1 0
rd
100010
rs1
i =0
i =1
TSUBccTV
1 0
rd
100011
rs1
i =0
i =1
MULScc
1 0
rd
100100
rs1
i =0
i =1
SLL
1 0
rd
100101
rs1
i =0
i =1
MATRA MHS
Rev. H (02 Dec.96)
12
5
ignored
4
0
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
shcnt
43
TSC691E
Mnemonic
Opcodes with Format
31 30
SRL
1 0
29
25
rd
24 22 21 19
100110
18
14
rs1
13
i =0
12
5
ignored
i =1
SRA
1 0
rd
100111
rs1
i =0
ignored
rs2
shcnt
1 0
rd
101000
ignored
I*
ignored
RDPSR
1 0
rd
101001
ignored
I*
ignored
RDWIM
1 0
rd
101010
ignored
I*
ignored
RDTBR
1 0
rd
101011
ignored
I*
ignored
WRY
1 0
ignored
110000
rs1
i =0
1 0
ignored
110001
rs1
i =0
i =1
WRWIM
1 0
ignored
110010
rs1
i =0
i =1
WRTBR
1 0
ignored
110011
rs1
i =0
i =1
44
shcnt
RDY
WRPSR
0
rs2
i =1
i =1
4
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 36. Instruction Opcode Numeric Listing (continued)
Opcodes with Format
Mnemonic
31 30
29
25
24 22
21 19
18
14
13
12
5
4
0
FPOP1
1 0
rd
110100
rs1
OPF
rs2
FMOVs
1 0
rd
110100
ignored
0 0 0 0 0 0 0 0 1
rs2
FNEGs
1 0
rd
110100
ignored
0 0 0 0 0 0 1 0 1
rs2
FABSs
1 0
rd
110100
ignored
0 0 0 0 0 1 0 0 1
rs2
FSQRTs
1 0
rd
110100
ignored
0 0 0 1 0 1 0 0 1
rs2
FSQRTd
1 0
rd
110100
ignored
0 0 0 1 0 1 0 1 0
rs2
FSQRTx
1 0
rd
110100
ignored
0 0 0 1 0 1 0 1 1
rs2
FADDs
1 0
rd
110100
rs1
0 0 1 0 0 0 0 0 1
rs2
FADDd
1 0
rd
110100
rs1
0 0 1 0 0 0 0 1 0
rs2
FADDx
1 0
rd
110100
rs1
0 0 1 0 0 0 0 1 1
rs2
FSUBs
1 0
rd
110100
rs1
0 0 1 0 0 0 1 0 1
rs2
FSUBd
1 0
rd
110100
rs1
0 0 1 0 0 0 1 1 0
rs2
FSUBx
1 0
rd
110100
rs1
0 0 1 0 0 0 1 1 1
rs2
FMULs
1 0
rd
110100
rs1
0 0 1 0 0 1 0 0 1
rs2
FMULd
1 0
rd
110100
rs1
0 0 1 0 0 1 0 1 0
rs2
FMULx
1 0
rd
110100
rs1
0 0 1 0 0 1 0 1 1
rs2
FDIVs
1 0
rd
110100
rs1
0 0 1 0 0 1 1 0 1
rs2
FDIVd
1 0
rd
110100
rs1
0 0 1 0 0 1 1 1 0
rs2
FDIVx
1 0
rd
110100
rs1
0 0 1 0 0 1 1 1 1
rs2
FiTOs
1 0
rd
110100
ignored
0 1 1 0 0 0 1 0 0
rs2
FdTOs
1 0
rd
110100
ignored
0 1 1 0 0 0 1 1 0
rs2
FxTOs
1 0
rd
110100
ignored
0 1 1 0 0 0 1 1 1
rs2
FiTOd
1 0
rd
110100
ignored
0 1 1 0 0 1 0 0 0
rs2
FsTOd
1 0
rd
110100
ignored
0 1 1 0 0 1 0 0 1
rs2
FxTOd
1 0
rd
110100
ignored
0 1 1 0 0 1 0 1 1
rs2
FiTOx
1 0
rd
110100
ignored
0 1 1 0 0 1 1 0 0
rs2
MATRA MHS
Rev. H (02 Dec.96)
45
TSC691E
Mnemonic
Opcodes with Format
31 30
29
25
24 22
21 19
18
14
13
5
4
0
FsTOx
1 0
rd
110100
ignored
0 1 1 0 0 1 1 0 1
rs2
FdTOx
1 0
rd
110100
ignored
0 1 1 0 0 1 1 1 0
rs2
FsTOi
1 0
rd
110100
ignored
0 1 1 0 1 0 0 0 1
rs2
FdTOi
1 0
rd
110100
ignored
0 1 1 0 1 0 0 1 0
rs2
FxTOi
1 0
rd
110100
ignored
0 1 1 0 1 0 0 1 1
rs2
FPOP2
1 0
rd
110101
rs1
OPF
rs2
FCMPs
1 0
ignored
110101
rs1
0 0 1 0 1 0 0 0 1
rs2
FCMPd
1 0
ignored
110101
rs1
0 0 1 0 1 0 0 1 0
rs2
FCMPx
1 0
ignored
110101
rs1
0 0 1 0 1 0 0 1 1
rs2
FCMPEs
1 0
ignored
110101
rs1
0 0 1 0 1 0 1 0 1
rs2
FCMPEd
1 0
ignored
110101
rs1
0 0 1 0 1 0 1 1 0
rs2
FCMPEx
1 0
ignored
110101
rs1
0 0 1 0 1 0 1 1 1
rs2
FPOP1
1 0
rd
110110
rs1
OPC
rs2
FPOP2
1 0
rd
110111
rs1
OPC
rs2
JMPL
1 0
rd
111000
rs1
i =0
i =1
46
12
ignored
rs2
simm13
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 37. Instruction Opcodes Numeric Listing (continued)
Opcodes with Format
Mnemonic
31 30
RETT
29
1 0
25
ignored
24
19
111001
18
14
rs1
13
i =0
i =1
Ticc
1 0
I*
cond
111010
rs1
i =0
i =1
IFLUSH
1 0
ignored
111011
rs1
i =0
i =1
SAVE
1 0
rd
111100
rs1
i =0
i =1
RESTORE
1 0
rd
111101
rs1
i =0
i =1
LD
1 1
rd
000000
rs1
i =0
i =1
LDUB
1 1
rd
000001
rs1
i =0
i =1
LDUH
1 1
rd
000010
rs1
i =0
i =1
LDD
1 1
rd
000011
rs1
i =0
i =1
ST
1 1
rd
000100
rs1
i =0
i =1
STB
1 1
rd
000101
rs1
i =0
i =1
STH
1 1
rd
000110
rs1
i =0
i =1
STD
1 1
rd
000111
rs1
i =0
i =1
MATRA MHS
Rev. H (02 Dec.96)
12
5
ignored
4
0
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
47
TSC691E
Mnemonic
Opcodes with Format
31 30
LDSB
1 1
29
25
rd
24
19
001001
18
14
rs1
13
i =0
12
5
ignored
i =1
LDSH
1 1
001010
rs1
i =0
1 1
rd
001101
rs1
i =0
1 1
rd
001111
rs1
i =0
rs2
simm13
ignored
rs2
simm13
ignored
i =1
48
rs2
ignored
i =1
SWAP
0
simm13
i =1
LDSTUB
4
rs2
simm13
LDA
1 1
rd
010000
rs1
i =0
asi
rs2
LDUBA
1 1
rd
010001
rs1
i =0
asi
rs2
LDUHA
1 1
rd
010010
rs1
i =0
asi
rs2
LDDA
1 1
rd
010011
rs1
i =0
asi
rs2
STA
1 1
rd
010100
rs1
i =0
asi
rs2
STBA
1 1
rd
010101
rs1
i =0
asi
rs2
STHA
1 1
rd
010110
rs1
i =0
asi
rs2
STDA
1 1
rd
010111
rs1
i =0
asi
rs2
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 38. Instruction Opcodes Numeric Listing (continued)
Opcodes with Format
Mnemonic
31 30
29
25
24 22 21 19
18
14
13
12
5
4
0
LDSBA
1 1
rd
011001
rs1
i =0
asi
rs2
LDSHA
1 1
rd
011010
rs1
i =0
asi
rs2
LDSTUBA
1 1
rd
011101
rs1
i =0
asi
rs2
SWAPA
1 1
rd
011111
rs1
i =0
asi
rs2
LDF
1 1
rd
100000
rs1
i =0
ignored
rs2
i =1
LDFSR
1 1
rd
100001
rs1
i =0
i =1
LDDF
1 1
rd
100011
rs1
i =0
i =1
STF
1 1
100100
rs1
i =0
i =1
STFSR
1 1
rd
100101
rs1
i =0
i =1
STDFQ
1 1
rd
100110
rs1
i =0
i =1
STDF
1 1
rd
100111
rs1
i =0
i =1
LDC
1 1
rd
110000
rs1
i =0
i =1
LDCSR
1 1
rd
110001
rs1
i =0
i =1
LDDC
1 1
rd
110011
rs1
i =0
i =1
STC
1 1
rd
110100
rs1
i =0
i =1
STCSR
1 1
rd
110101
rs1
i =0
i =1
STDCQ
1 1
rd
110110
rs1
i =0
i =1
STDC
1 1
rd
110111
rs1
i =0
i =1
MATRA MHS
Rev. H (02 Dec.96)
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
ignored
rs2
simm13
49
TSC691E
3.5. Signal Description
This section provides a description of the TSC691E’s external signals. Functionally, the IU’s external signals can be
divided into four categories: memory subsystem interface, floating-point/coprocessor interface, interrupt and control
signals, and power and clock signals.
APAR/ASPAR/DPAR/IMPAR/IFPAR
FIPAR
HWERROR
FP
FHOLD
FEXC
FXACK
FCC[1:0]
FCCV
FINS1
FINS2
FPSYN
A[31:0]
ASI[7:0]
SIZE[1:0]
MAO
D[31:0]
MDS
MHOLDA
MHOLDB
BHOLD
TOE
COE
CLK
IRL[3:0]
INTACK
MCERR
CMODE
TSC691E SPARC
Integer Unit
MEXC
RESET
ERROR
RD
W
WRT
DXFER
LDSTO
INULL
LOCK
DOE
AOE
IFT
FLOW
601MODE
HALT
INST
FLUSH
TAP = TCLK/TRST/TMS/TDI/TDO
FP
CHOLD
CEXC
CXACK
CCC[1:0]
CCCV
CINS1
CINS2
Figure 22. TSC691E External Signals
Signals that are active LOW are marked with an overscore; all others are active HIGH. Figure 22 summarizes the
signals described in this section. Table 39 provides a summary of the external signals for the TSC691E.
Note: In the descriptions below, and in this manual in general, when a signal is asserted it is active, and when it is
deasserted it is inactive. When a signal is HIGH, it is a logical 1; when it is LOW, it is a logical 0. This is true regardless
of whether it is asserted or deasserted.
50
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 39. TSC691E External Signal Summary
Memory Subsystem Interface Signals:
Signal Name
Impedance of Three–State
Output =20kΩ
Description
Signal Type
Active
A<31:0>
Address Bus
Three–State Output
APAR
Address Bus Parity
Three–State Output
HIGH
AOE
Address Output Enable
Input
LOW
ASI<7:0>
Address Space Identifier
Three–State Output
COE
Control Output Enable
Input
LOW
BHOLD
Bus Hold
Input
LOW
D<31:0>
Data Bus
Three–State BiDir.
DPAR
Data Bus Parity
Three-State BiDir.
HIGH
DOE
Data Output Enable
Input
LOW
DXFER
Data Transfer
Three–State Output
HIGH
IFT
Instruction Cache Flush Trap
Input
LOW
INULL
Integer Unit Nullify Cycle
Three–State Output
HIGH
LDSTO
Atomic Load-Store
Three–State Output
HIGH
LOCK
Bus Lock
Three–State Output
HIGH
MAO
Memory Address Output
Input
HIGH
MDS
Memory Data Strobe
Input
LOW
MEXC
Memory Exception
Input
LOW
MHOLDA
Memory Bus Hold A
Input
LOW
MHOLDB
Memory Bus Hold B
Input
LOW
RD
Read Access
Three–State Output
HIGH
SIZE<1:0>
Bus Transaction Size
Three–State Output
ASPAR
ASI and SIZE Parity
Three–State Output
HIGH
WE
Write Enable
Three–State Output
LOW
WRT
Advanced Write
Three–State Output
HIGH
Three–State Output
HIGH
IMPAR
IU to
MEC [1]
Control Parity
Floating–Point / Coprocessor Interface Signals:
Signal Name
Description
Signal Type
Active
CCC<1:0>
Coprocessor Condition Codes
Input
CCCV
Coprocessor Condition Codes Valid
Input
HIGH
CEXC
Coprocessor Exception
Input
LOW
CHOLD
Coprocessor Hold
Input
LOW
CINS1
Coprocessor Instruction in Buffer 1
Three–State Output
HIGH
MATRA MHS
Rev. H (02 Dec.96)
51
TSC691E
Floating–Point / Coprocessor Interface Signals:
Signal Name
Description
Signal Type
Active
CINS2
Coprocessor Instruction in Buffer 2
Three–State Output
HIGH
FP
Coprocessor Unit Present
Input
LOW
CXACK
Coprocessor Exception Acknowledge
Three–State Output
HIGH
FCC<1:0>
Floating–Point Condition Codes
Input
FCCV
Floating–Point Condition Codes Valid
Input
HIGH
FEXC
Floating–Point Exception
Input
LOW
FHOLD
Floating–Point Hold
Input
LOW
FIPAR
FPU to IU Control Parity
Input
HIGH
FINS1
Floating–Point Instruction in Buffer 1
Three–State Output
HIGH
FINS2
Floating–Point Instruction in Buffer 2
Three–State Output
HIGH
FLUSH
Floating–Point/Coprocessor Instruction Flush
Three–State Output
HIGH
FP
Floating–Point Unit Present
Input
LOW
FXACK
Floating–Point Exception Acknowledge
Three–State Output
HIGH
INST
Instruction Fetch
Three–State Output
HIGH
IFPAR
IU to FPU Control Parity
Three-State Output
HIGH
Note 1 : TSC693E = Memory controller system support circuit which contains fault detection and peripheral control
function.
Table 40. TSC691E External Signal Summary (continued)
Interrupt and Control Signals:
Signal Name
Description
Signal Type
Active
IRL<3:0>
Interrupt Request Level
Input
INTACK
Interrupt Acknowledge
Three–State Output
HIGH
RESET
Reset
Input
LOW
ERROR
Error State
Three–State Output
LOW
HWERROR
Hardware error Detected
Three–State Output
LOW
MCERR
Comparison error
Three–State Output
LOW
FLOW
Enable Program FLOW Control
Input
LOW
CMODE
Checker Mode
Input
LOW
601MODE
Normal TSC691 Mode
Input
LOW
FPSYN
Floating–Point Synonym Mode
Input
HIGH
TOE
Test Mode Output Enable
Input
LOW
HALT
Halt Mode
Input
LOW
52
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Test Access Port Signals:
Signal Name
Description
Signal Type
Active
TCLK
Test Clock
Input
TRST
Test reset
Input
LOW
TMS
Test Mode Select
Input
HIGH
TDI
Test Data Input
Input
TDO
Test Data Output
Three-State Output
Power and Clock Signals:
Signal Name
Description
Signal Type
CLK
Clock
Input
VCCI
Main internal VCC
Input
VCCO
Output driver VCC
Input
VCCT
Input circuit VCC
Input
VSSI
Main internal VSS
Input
VSSO
Output driver VSS
Input
VSST
Input circuit VSS
Input
Active
3.5.1. Memory Subsystem Interface Signals
Memory interface signals consist of the address lines (40 bits), bidirectional data lines (32 bits), transaction size lines
(2 bits), and various control signals.
3.5.1.1. A<31:0>—Address Bus (output)
The 32-bit address bus carries instruction or data addresses during a fetch or load/store operation. Addresses are sent
out unlatched and must be latched external to the TSC691E. Assertion of the MAO signal during a cache miss (which
is signaled by pulling one of the MHOLD lines low) will force the Integer Unit to place the previous (missed) address
on the address bus. The address bus is three-stated (on chip pull_up resistor=20kΩ) when the AOE or TOE signal is
deasserted (HIGH).
3.5.1.2. APAR—Address Bus Parity (output)
This signal contains the odd parity over the 32-bit address bus and is asserted simultaneously with the memory
address.It is high-Z (on chip pull_up resistor=20kΩ) when the AOE or TOE signal is deasserted.
3.5.1.3. AOE—Address Output Enable (input)
Assertion of this signal enables the output drivers for the address bus, A<31:0>, and the ASI bus, ASI<7:0>, and is the
normal condition. Deassertion of AOE three-states (on chip pull_up resistor=20kΩ) the output drivers and should only
be done when the bus is granted to another bus master (i.e., when either BHOLD or MHOLDA/B is asserted).
3.5.1.4. ASI<7:0>—Address Space Identifier (output)
These 8 bits constitute the Address Space Identifier (ASI), which identifies the memory address space to which the
instruction or data access is being directed. The ASI bits are sent out unlatched—simultaneously with the memory
address—and must be latched externally. Assertion of the MAO signal during a cache miss (which is signaled by pulling
one of the MHOLD lines low) will force the integer unit to place the previous address space identifier on the ASI<7:0>
pins. The ASI pins are three-stated (on chip pull_up resistor=20kΩ) when the AOE or TOE signal is deasserted (HIGH).
Encoding of the ASI bits is shown in Table 41 .
MATRA MHS
Rev. H (02 Dec.96)
53
TSC691E
Table 41. ASI Assignments
TSC691E
Address Space Identifier (ASI)
Address Space
00001000 (08 H)
User Instruction
00001010 (0A H)
User Data
00001001 (09 H)
Supervisor Instruction
00001011 (0B H)
Supervisor Data
1
2
3
4
5
6
CLK
A<31:0>
D<31:0>
A1
A2
A3
Wr PSR
A4
Inst 2
ASI[7:0]
Inst 3
A5
Inst 4
O9
A6
Inst 5
08
Figure 23. ASI timing with a WRPSR Instruction
3.5.1.5. ASPAR—ASI and SIZE Parity (output)
This signal contains the odd parity over the 8-bit address space identifier and 2 bit Bus Transaction Size. It is asserted
simultaneously with the ASI and SIZE and will be high-Z (on chip pull_up resistor=20kΩ) when the AOE, COE or
TOE signal is deasserted.
3.5.1.6. BHOLD—Bus Hold (input)
BHOLD is asserted when an external bus master wants control of the data bus. Assertion of this signal will freeze the
processor pipeline, so after deassertion of BHOLD, external logic must guarantee that the data at all inputs to the
TSC691E is the same as it was before BHOLD was asserted. This signal is tested on the falling edge (midpoint) of
a cycle and must be valid and stable at the processor for the duration of the specified set–up time prior to the falling
edge of CLK. All HOLD signals are latched in the TSC691E (transparent latch with clock high) before they are used.
Because MDS and MEXC signals are recognized while this input is active, BHOLD should only be used for bus access
requests by an external device. BHOLD should not be asserted when LOCK is asserted.
3.5.1.7. COE—Control Output Enable (input)
Assertion of this signal enables the output drivers for SIZE<1:0>, RD, WE, WRT, LOCK, LDSTO, and DXFER
outputs, and is the normal condition. Deassertion of COE three-states (on chip pull_up resistor=20kΩ) these output
drivers and should only be done when the bus is granted to another bus master (i.e., when either BHOLD or
MHOLDA/B is asserted).
3.5.1.8. D<31:0>—Data Bus (bidirectional)
These signals form a 32-bit bidirectional data bus that serves as the interface between the integer unit and memory.
The data bus is only driven by the TSC691E during the execution of integer store instructions and the store cycle of
atomic-load-store instructions. Similarly, the FPU drives the data bus only during the execution of floating-point store
instructions.
54
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Store data is sent out unlatched and must be latched externally before it is used. Once latched, store data is valid during
the second data cycle of a store single access, the second and third data cycle of a store double access, and the third
data cycle of an atomic-load-store access.
Alignment for load and store instructions is performed by the processor. Doublewords are aligned on 8-byte boundaries,
words on 4-byte boundaries, and halfwords on 2-byte boundaries. If a doubleword, word, or halfword load or store
instruction generates an improperly aligned address, a memory address not aligned trap will occur. Instructions and
operands are always expected to reside in a 32-bit wide memory. D<31> corresponds to the most significant bit of the
most significant byte of a 32-bit word going to or from memory.
The Data bus is three-stated (on chip pull_up resistor=20kΩ) when the DOE or TOE signal is deasserted (HIGH)
3.5.1.9.DPAR—Data Bus Parity (bidirectional)
This signal contains the odd parity over the 32-bit bidirectional data bus.
In case of store data operations the parity bit is generated and launched in parallel by the IU. In case of load data
operations the parity is checked by the IU.
This signal will be high-Z (on chip pull_up resistor=20kΩ) when the DOE or TOE signal is deasserted.
3.5.1.10. DOE—Data Output Enable (input)
Assertion of this signal enables the output drivers for the data bus, D<31:0>, and is the normal condition. Deassertion
of DOE three-states (on chip pull_up resistor=20kΩ) the data bus output drivers and should only be done when the bus
is granted to another bus master (i.e., when either BHOLD or MHOLDA/B is asserted).
3.5.1.11. DXFER—Data Transfer (output)
DXFER is used to differentiate between the addresses being sent out for instruction fetches and the addresses of data
fetches. DXFER is asserted by the processor during the address cycles of all bus data transfer cycles, including both
cycles of store single and all three cycles of store double and atomic load-store. DXFER is sent out unlatched and must
be latched externally before it is used.
3.5.1.12. IFT—Instruction Cache Flush Trap (input)
The state of this signal determines whether or not execution of the IFLUSH instruction generates a trap. If IFT=0, then
execution of IFLUSH causes an illegal instruction trap. If IFT=1, then IFLUSH executes like a NOP with no side
effects.
3.5.1.13. INULL—Integer Unit Nullify Cycle (output)
The processor asserts INULL to indicate that the current memory access is being nullified. It is asserted in the same
cycle in which the address being nullified is active (though no longer on the address bus, the address is held in the
external address latches). INULL is used to prevent a cache miss (in systems with cache memory) and to disable
memory exception generation for the current memory access. This means that MDS and MEXC should not be asserted
for a memory access in which INULL=1. INULL is a latched output and should not be latched externally. If a
floating-point unit or coprocessor is present in the system, INULL should be Ored with the FNULL and CNULL signals
to generate a final NULL signal.
INULL is asserted under the following conditions:
2. During the second data cycle of any store instruction (including Atomic Load-Store) to nullify the second occurrence of the store address.
3. On all traps, to nullify the third instruction fetch after the trapped instruction. For reset, it nullifies the error-producing address.
4. On a load in which the hardware interlock is activated.
5. JMPL and RETT instructions.
3.5.1.14. LDSTO—Atomic Load–Store (output)
This signal is used to identify an atomic load-store to the system and is asserted by the integer unit during all the data
cycles (the load cycle and both store cycles) of atomic load-store instructions. LDSTO is sent out unlatched and must
be latched externally before it is used.
MATRA MHS
Rev. H (02 Dec.96)
55
TSC691E
3.5.1.15. LOCK—Bus Lock (output)
LOCK is asserted by the processor when it needs to retain control of the bus (address and data) for multiple cycle
transactions (Load Double, Store Single and Double, Atomic Load–Store). The bus will not be granted to another bus
master as long as LOCK is asserted. Note that BHOLD should not be asserted in the processor clock cycle which follows
a cycle in which LOCK is asserted. LOCK is sent out unlatched and must be latched externally before it is used.
3.5.1.16. MAO—Memory Address Output (input)
This signal is asserted during an MHOLD condition to force the previous (missed) memory access parameters back
on their various busses and control lines. The miss parameters are those that were valid on the rising edge of the clock,
one cycle before the cycle in which MHOLD was asserted. A logic HIGH value at this signal during a cache miss causes
the integer unit to put A<31:0>, ASI<7:0>, SIZE<1:0>, RD, WE, WRT, LDSTO, LOCK, and DXFER values
corresponding to the missed memory address on the bus.
Normally, MAO is kept at a LOW level, thereby selecting the access parameters for the current memory address. MAO
should not be used for a cache miss during a store cycle, because it would select the wrong value for WE.
MAO must be driven LOW while RESET is LOW.
3.5.1.17. MDS—Memory Data Strobe (input)
MDS is asserted by the memory system to enable the clock to the integer unit’s instruction register (during an
instruction fetch) or to the load result register (during a data fetch) while the pipeline is frozen with an MHOLDA/B.
In a system with cache, MDS is used to signal the processor when the missed data (cache miss) is ready on the data
bus. In a system with slow memories, MDS tells the processor when the read data is available on the bus. During a cache
line replacement, MDS may be asserted anywhere within the MHOLD cycle and deasserted before MHOLD is
released. For example, if a cache miss occurs on word 2 of a 4-word cache line, MDS should only be driven active while
word 2 is being replaced in the cache.
MDS is also used to strobe in the MEXC memory exception signal. MDS may only be asserted when the pipeline is
frozen with MHOLDA/B. The TSC691E samples MDS with an on-chip transparent latch before it is used.
3.5.1.18. MEXC—Memory Exception (input)
Assertion of this signal by the memory system initiates an instruction access exception or data access exception trap
and indicates to the TSC691E that the memory system was unable to supply a valid instruction or data. If MEXC is
asserted during an instruction fetch cycle, it generates an instruction access exception trap. If asserted during a data
cycle, it generates a data access exception trap.
MEXC is used as a qualifier for the MDS signal, and must be asserted when both MHOLDA/B and MDS are already
asserted. If MDS is applied without MEXC, the TSC691E accepts the contents of the data bus as valid. If MEXC
accompanies MDS, an exception is generated and the data bus content is ignored.
MEXC is latched in the processor on the rising edge of CLK and is used in the following cycle. MEXC must be
deasserted in the same clock cycle in which MHOLDA/B is deasserted.
3.5.1.19.MHOLD(A/B)—Memory Holds (inputs)
MHOLDA is used to freeze the clock to both the integer and floating-point units during a cache miss (for systems with
cache memory) or when accessing a slow memory. The processor pipeline is frozen while MHOLDA is asserted and
the TSC691E outputs revert to and maintain the value they had at the rising edge of the clock in the cycle in which
MHOLDA was asserted. This signal is tested on the falling edge (midpoint) of a cycle and must be valid and stable
at the processor for the duration of the specified set–up time prior to the falling edge of CLK.
MHOLDB behaves in the same fashion as MHOLDA, and either can be used to stop the processor during a cache miss
or memory exception. The pipeline is actually frozen by a “final” hold signal that is the logical OR of all hold signals
(MHOLDA, MHOLDB, and BHOLD). All HOLD signals are latched in the TSC691E (transparent latch with clock
high) before they are used.
Note that MHOLD must be driven HIGH while RESET is LOW.
3.5.1.20. RD—Read Access (output)
RD is sent out during the address portion of an access to specify whether the current memory access is a read (RD=1)
or a write (RD=0) operation. RD is set to “0” only during the address cycles of store instructions. For atomic load-store
56
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
instructions, RD is “1” during the load address cycle and “0” during the two store address cycles. It is sent out unlatched
by the Integer Unit and must be latched externally before it is used.
RD is used in conjunction with SIZE<1:0>, ASI<7:0>, and LDSTO to determine the type and to check the read/write
access rights of bus transactions. It may also be used to turn off the output drivers of data RAMs during a store operation.
3.5.1.21. SIZE<1:0>—Bus Transaction Size (outputs)
The coding on these pins specifies the size of the data being transferred during an instruction or data fetch. The value
of the size bits during a given cycle relates only to the memory address which appears on pins A<31:0> simultaneously
with the size outputs. It DOEs not apply to data which may be on the data bus during that same cycle.
Size bits are sent out unlatched and must be latched external to the TSC691E before they are used. SIZE<1:0> remains
valid during the data address cycles of loads, stores, load doubles, store doubles, and atomic load-stores. The
SIZE<1:0> pins are three-state (on chip pull_up resistor=20kΩ) when the COE or TOE signal is deaserted. Encoding
of the size bits is shown in Table 42 . For example, during an instruction fetch, SIZE<1:0> is set to “10”, because all
instructions are 32 bits long. For doubleword instructions, SIZE<1:0> is “11” for all data address cycles.
Table 42. SIZE Bit Encoding
SIZE<1>
SIZE<0>
Data Transfer Type
0
0
Byte
0
1
Halfword
1
0
Word
1
1
Word (Load/Store Double)
3.5.1.22. WE—Write Enable (output)
WE is asserted by the integer unit during the cycle in which the store data is on the data bus. For a store single
instruction, this is during the second store address cycle; the second and third store address cycles of store double
instructions, and the third load-store address cycle of atomic load-store instructions. It is sent out unlatched and must
be latched externally before it is used. To avoid writing to memory during memory exceptions, WE must be externally
qualified by the MHOLDA/B signals.
3.5.1.23. WRT—Advanced Write (output)
WRT is an early write signal, asserted by the processor during the first store address cycle of integer single or double
store instructions, the first store address cycle of floating-point single or double store instructions, and the second
load-store address cycle of atomic load-store instructions. WRT is sent out unlatched and must be latched externally
before it is used.
3.5.1.24. IMPAR—IU to MEC Control Parity (output)
This signal contains the odd parity over the DXFER, LDSTO, LOCK, RD, WE and WRT bits. The parity bit is
generated by the IU and will be checked by the MEC.
It will be high-Z (on chip pull_up resistor=20kΩ) when the COE or TOE signal is deasserted.
3.5.2. Floating-Point/Coprocessor Interface Signals
The IU incorporates a dedicated group of pins that act as direct-connect interfaces between the integer unit and both
the floating-point unit and the coprocessor. Using these connections, no external circuits are required to interface the
IU to the FPU and coprocessor. The interfaces consist of the following signals:
3.5.2.1. CCC<1:0>—Coprocessor Condition Codes (input)
These lines represent the current condition code bits from the Coprocessor State Register (CSR), qualified by the
CCCV signal. When CCCV=1, these bits are valid. During the execution of a CBccc instruction, the processor uses
CCC<1:0> to determine whether or not to take the branch. These bits are latched by the processor before they are used.
MATRA MHS
Rev. H (02 Dec.96)
57
TSC691E
3.5.2.2. CCCV—Coprocessor Condition Codes Valid (input)
This signal is a specialized hold used to synchronize coprocessor compare instructions with coprocessor branch
instructions. It is asserted (the normal condition) whenever the CCC<1:0> bits are valid. A coprocessor would deassert
CCCV (CCCV=0) as soon as a coprocessor compare instruction enters the coprocessor queue, unless an exception is
detected (see Section 3.9). Deasserting CCCV freezes the integer unit pipeline, preventing any further compares from
entering the pipeline. CCCV is reasserted when the compare is completed and the coprocessor condition codes are
valid, thus ensuring that the condition codes match the proper compare instruction. CCCV is latched in the TSC691E
before it is used.
3.5.2.3. CEXC—Coprocessor Exception (input)
CEXC is used to signal the integer unit that a coprocessor exception has occurred. CEXC must remain asserted until
the TSC691E takes the trap and acknowledges the coprocessor exception via the CXACK signal. Although
coprocessor exceptions can occur at any time, they are taken by the TSC691E only during the execution of a subsequent
FPop, a CBfcc instruction, or a coprocessor load or store instruction. A coprocessor implementation should deassert
CHOLD if it detects an exception while CHOLD is asserted. In such a case, CEXC should be asserted one cycle before
CHOLD is deasserted. CEXC is latched in the TSC691E before it is used.
3.5.2.4. CHOLD—Coprocessor Hold (input)
This signal is asserted by the coprocessor if a situation arises in which it cannot continue execution. The coprocessor
checks all dependencies in the decode stage of the instruction and asserts CHOLD (if necessary) in the next cycle. If
the integer unit receives a CHOLD, it freezes the instruction pipeline in the same cycle. Once the conditions causing
the CHOLD are resolved, the coprocessor deasserts CHOLD, releasing the instruction pipeline. CHOLD is latched in
the TSC691E before it is used.
The conditions under which the coprocessor asserts CHOLD are implementation dependent.
3.5.2.5. CINS1—Coprocessor Instruction in Buffer 1 (output)
CINS1 is asserted by the integer unit during the decode stage of the coprocessor instruction that is in the D1 buffer of
the coprocessor chip. The coprocessor uses this signal to begin decoding and execution of the D1 instruction, and to
latch it into its execute-stage register. CINS1 and CINS2 are never asserted in the same cycle.
3.5.2.6. CINS2—Coprocessor Instruction in Buffer 2 (output)
CINS2 is asserted by the Integer Unit during the decode stage of the coprocessor instruction that is in the D2 buffer
of the coprocessor chip. The Coprocessor uses this signal to begin decoding and execution of the D2 instruction, and
to latch it into its execute-stage register. CINS1 and CINS2 are never asserted in the same cycle.
3.5.2.7. FP—Coprocessor Unit Present (input)
When pulled low, FP indicates that a coprocessor is available to the system. It is normally pulled up to VDD through
a resistor, and then grounded by connection to the coprocessor. The integer unit will generate a FP disabled trap if FP=1
during the execution of an FPop, CBfcc, or coprocessor load or store instruction.
3.5.2.8. CXACK—Coprocessor Exception Acknowledge (output)
CXACK is asserted by the integer unit to inform the coprocessor that a trap has been taken for the currently asserted
CEXC signal. Receipt of the asserted CXACK causes the coprocessor to deassert CEXC, which in turn causes the to
deassert CXACK. CXACK is a latched output and should not be latched externally.
3.5.2.9. FCC<1:0>—Floating-Point Condition Codes (input)
These lines represent the current condition code bits from the FPU’s Floating-point State Register (FSR), qualified by
the FCCV signal. When FCCV=1, these bits are valid. During the execution of an FBfcc instruction, the processor uses
FCC<1:0> to determine whether or not to take the branch. These bits are latched by the processor before they are used.
3.5.2.10. FCCV—Floating-Point Condition Codes Valid (input)
This signal is a specialized hold used to synchronize FPU compare instructions with floating-point branch instructions.
It is asserted (the normal condition) whenever the FCC<1:0> bits are valid. The FPU deasserts FCCV (FCCV=0) as
soon as a floating-point compare instruction enters the floating-point queue, unless an exception is detected.
58
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Deasserting FCCV freezes the integer unit pipeline, preventing any further compares from entering the pipeline. FCCV
is reasserted when the compare is completed and the floating-point condition codes are valid, thus ensuring that the
condition codes match the proper compare instruction. FCCV is latched in the TSC691E before it is used.
3.5.2.11. FEXC—Floating-Point Exception (input)
FEXC is used to signal the integer unit that a floating-point exception has occurred. FEXC must remain asserted until
the TSC691E takes the trap and acknowledges the FPU exception via the FXACK signal. Although floating-point
exceptions can occur at any time, they are taken by the TSC691E only during the execution of a subsequent FPop, an
FBfcc instruction, or a floating-point load or store instruction. The FPU deasserts FHOLD if it detects an exception
while FHOLD is asserted. In such a case, FEXC is asserted one cycle before FHOLD is deasserted. FEXC is latched
in the TSC691E before it is used.
3.5.2.12. FHOLD—Floating-Point Hold (input)
This signal is asserted by the FPU if a situation arises in which the FPU cannot continue execution. The FPU checks
all dependencies in the decode stage of the instruction and asserts FHOLD (if necessary) in the next cycle. If the integer
unit receives an FHOLD, it freezes the instruction pipeline in the same cycle. Once the conditions causing the FHOLD
are resolved, the FPU deasserts FHOLD, releasing the instruction pipeline. FHOLD is latched in the TSC691E before
it is used.
An FHOLD is asserted if (1) the FPU encounters an STFSR instruction with one or more FPops pending in the queue,
(2) if either a resource or operand dependency exists between the FPop being decoded and any FPops already being
executed, or (3) if the floating-point queue is full.
3.5.2.13. FIPAR—FPU to IU Control Parity (input)
This signal contains the odd parity over the FCC<1:0>, FCCV,FEXC and FHOLD bits. The parity bit is generated by
the FPU and will be checked by the IU.
3.5.2.14. FINS1—Floating-Point Instruction In Buffer 1 (output)
FINS1 is asserted by the integer unit during the decode stage of the floating-point instruction that is in the D1 buffer
of the floating-point unit. The FPU uses this signal to begin decoding and execution of the D1 instruction, and to latch
it into its execute-stage register. FINS1 and FINS2 are never asserted in the same cycle and both are ignored if (1)
FLUSH is asserted, (2) any HOLD is asserted, or (3) if FCCV or CCCV is deasserted.
3.5.2.15. FINS2—Floating-Point Instruction In Buffer 2 (output)
FINS2 is asserted by the integer unit during the decode stage of the floating-point instruction that is in the D2 buffer
of the floating-point unit. The FPU uses this signal to begin decoding and execution of the D2 instruction, and to latch
it into its execute-stage register. FINS1 and FINS2 are never asserted in the same cycle and both are ignored if (1)
FLUSH is asserted, (2) any HOLD is asserted, or (3) if FCCV or CCCV is deasserted.
3.5.2.16. FLUSH—Floating-Point/Coprocessor Instruction Flush (output)
This signal is asserted by the integer unit whenever it takes a trap. FLUSH is used by the FPU (or coprocessor) to flush
the instructions in its instruction buffers. These instructions, as well as the instructions annulled in the TSC691E’s
pipeline, are restarted after the trap handler is finished. If the trap was not caused by a floating-point (or coprocessor)
exception, instructions already in the floating-point (or coprocessor) queue may continue their execution. If the trap
was caused by a floating-point (or coprocessor) exception, the FP (or FP) queue must be emptied before the FPU
(coprocessor) can resume execution.
3.5.2.17. FP—Floating-point Unit Present (input)
When pulled low, FP indicates that a floating-point unit is available to the system. It is normally pulled up to VDD
through a resistor, and then grounded by connection to the FPU. The integer unit will generate an FP disabled trap if
FP=1 during the execution of an FPop, FBfcc, or floating-point load or store instruction.
3.5.2.18. FXACK—Floating-Point Exception Acknowledge (output)
FXACK is asserted by the integer unit to inform the floating-point unit that a trap has been taken for the currently
asserted FEXC signal. Receipt of the asserted FXACK causes the FPU to deassert FEXC. FXACK is a latched output
and should not be latched externally.
MATRA MHS
Rev. H (02 Dec.96)
59
TSC691E
3.5.2.19. INST—Instruction Fetch (output)
The INST signal is asserted by the integer unit whenever a new instruction is being fetched. It is used by the
floating-point unit or coprocessor to latch the instruction currently on the data bus into an FPU or coprocessor
instruction buffer. SPARC-compatible floating-point units and coprocessors have two instruction buffers (D1 and D2)
to save the last two fetched instructions. When INST is asserted, a new instruction enters buffer D1 and the instruction
that was in D1 moves to buffer D2. INST is a latched output and should not be latched externally.
3.5.2.20. IFPAR—IU to FPU Control Parity (output)
This signal contains the odd parity over the FINS1, FINS2, FLUSH, FXACK and INST bits. The parity bit is generated
by the IU and will be checked by the FPU. It will be high-Z (on chip pull_up resistor=20kΩ) when the TOE signal is
deasserted.
3.5.3. Interrupt and Control Signals
The following signals are used by the integer unit to control and to receive input from external events.
3.5.3.1. ERROR—Error State (output)
This signal is asserted when the integer unit enters the ‘error mode’ state. This happens if a synchronous trap occurs
while traps are disabled (the PSR’s ET bit =0). Before it enters the error mode state, the TSC691E saves the PC and
nPC and sets the trap type (tt) for the trap causing the error mode into the TBR. It then asserts the ERROR signal and
halts. The only way to restart a processor which is in the error mode state is to trigger a reset by asserting the RESET
signal.
3.5.3.2. HWERROR—Hardware error (output)
The HWERROR outputs indicate a parity error occurs, except Master/Checker errors. When asserted low, the IU trap
with Trap Type value depending of the internal parity error (see Table 47 , page 116). It is deasserted when the parity
error is removed (i.e. by resuming this instruction), or by a reset cycle.
3.5.3.3. FLOW —Enable FLOW Control (input)
Forcing this input low will enable the program FLOW control. It is a static signal and shall not change when running.
3.5.3.4. MCERR—Comparison error (output)
This signal is asserted low in checker mode when a comparison error occurs on the internal output signals vis-à-vis
the output signal (excepted TAP, MCERR, HWERROR and ERROR signals) of the master IU. It is deasserted when
the error disappears. See chapter 4.4 for more information.
This signal is also asserted in master mode when the output DOEsn’t match the value of the pin.
This output is high-Z (on chip pull_up resistor=20kΩ) when the TOE signal is deasserted.
3.5.3.5. 601MODE—Normal 601MODE Operation (input)
Forcing this input low will disable the parity checking of all input signals. This means the IU will operate with the
standard input signals. Nevertheless generation and checking of internal parity bit is still active. Parity on the data bus
is generated internally and parity checking on the control bus is disabled.
3.5.3.6. CMODE—checker Mode (input)
Assertion of this signal will set the IU to act as a checker to support master/checker operation. All output signals except
ERROR, HWERROR, MCERR and TAP signals will be high-Z (on chip pull_up resistor=20kΩ). It is a static signal
and shall not change when running. CMODE signal can change when RESET signal is asserted or when the IU is in
HALT mode.
3.5.3.7. FPSYN—Floating-point Synonym Mode (input)
This is a mode signal which will be used to allow execution of additional instructions in future designs. For the
TSC691E, it should be kept grounded.
60
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
3.5.3.8. INTACK—Interrupt Acknowledge (output)
INTACK is a latched output that is asserted by the integer unit when an external interrupt is taken, not when it is sampled
and latched.
3.5.3.9. IRL<3:0>—Interrupt Request Level (input)
The state of these pins defines the External Interrupt Level (IRL). IRL<3:0>=0000 indicates that no external interrupts
are pending and is the normal state of the IRL pins. IRL<3:0>=1111 signifies a nonmaskable interrupt. All other
interrupt levels are maskable by the Processor Interrupt Level (PIL) field of the Processor State Register (PSR). The
integer unit uses two on-chip synchronizing latches to sample these signals, and a given level must remain valid for
two consecutive cycles to be recognized. External interrupts should be latched and prioritized by external logic before
they are passed to the TSC691E. Logic must also keep an interrupt valid until it is taken and acknowledged. External
interrupts can be acknowledged by system software or by the TSC691E’s INTerrupt ACKnowledge (INTACK) signal.
3.5.3.10. RESET—Integer Unit reset (input)
Assertion of this signal will reset the integer unit. RESET must be asserted for a minimum of nine processor clock
cycles. After RESET is deasserted, the integer unit starts fetching from address 0. RESET is latched by the TSC691E
before it is used.
The RESET signal input is protected by a glitch removal filter and pulses which are so short that they are detected only
during one clock period are not influencing the IU. RESET signal is also protected with two-rail coding and an error
detected will lead to error mode.
3.5.3.11. TOE—Test Mode Output Enable (input)
When deasserted, this signal will three-state all integer unit output drivers (on chip pull_up resistor=20kΩ). Thus, in
normal operation, this signal should always be asserted (tied to ground). Deassertion of TOE isolates the TSC691E
from the system for debugging purposes.
3.5.3.12. HALT—HALT (input)
When asserted this input will freeze the IU pipeline and the clock. All information placed in the registers of the IU
remains unchanged. By deasserting HALT, execution of the IU will resume. (see 5.2.2.14, page 135)
When the IU is in HALT mode, the TAP is still operating.
3.5.4. TAP signals
The following Test Access Port interface (IEEE standard 1149.1-1990) is used to perform boundary scan for test and
debugging purposes.
3.5.4.1. TCLK—Test Clock (input)
This clock signal permits test data to be shifted into or out of the instruction or test data register cells without interfering
with the on chip system logic.The IEEE standards requires that TCLK can be stopped at 0 indefinitely without causing
any change to the state of the test logic.
3.5.4.2. TRST—TEST reset (input)
The TAP’s test logic is reset when a logical 0 is applied to this port.
3.5.4.3. TMS—Test Mode Select (input)
The TMS input signal is interpreted by the TAP controller to control the test operations.
The received signal is sampled at the rising edge of the TCLK pulses.
3.5.4.4. TDI—Test Data Input (input)
Serial input data applied to this port is fed either into the instruction register or into a test data register, depending on
the sequence previously applied to the TMS input.
The received input data is sampled at the rising edge of the TCLK pulse.
MATRA MHS
Rev. H (02 Dec.96)
61
TSC691E
3.5.4.5. TDO—Test Data Output
Depending on the sequence previously applied to the TMS input, the contents of either the instruction register or the
data register are serially shifted out toward the TDO.
The data out of the TDO is clocked at the falling edge of the TCLK pulses. TDO should be in the inactive state except
when scanning is in progress. (Use of 3 state driver)
3.5.5. Power and Clock Signals
The signals listed below provide clocking and power to the integer unit.
3.5.5.1. CLK—Clock (input)
CLK is a 50%-duty-cycle clock used for clocking the integer unit’s pipeline registers. The rising edge of CLK defines
the beginning of each pipeline stage and a processor cycle is equal to a full clock cycle.
3.5.5.2. VCCO, VCCI, VCCT—Power (inputs)
These pins provide +5V power to various sections of the processor. Power is supplied on three different busses to
provide clean, stable power to each section: output drivers, main internal circuitry, and the input circuits. VCCO pins
supply the output driver bus; VCCI pins supply main internal circuitry bus; and VCCT pins supply the input circuit
bus.
3.5.5.3. VSSO, VSSI, VSST—Ground (inputs)
These pins provide ground return for the power signals. Ground is supplied on three different busses to match the power
signals to each section: VSSO pins for the output driver bus; VSSI pins for the main internal circuitry bus; and VSST
pins for the input circuit bus.
3.6. Pipeline and Instruction Execution Timing
One of the major contributing factors to the TSC691E’s very high performance is an instruction execution rate
approaching one instruction per clock cycle. To achieve that rate of execution, the TSC691E employs a four-stage
instruction pipeline that permits parallel execution of multiple instructions.
Instruction
from Memory
B
u
f
f
e
r
B
u
f
f
e
r
D
e
c
o
d
e
E
x
e
c
u
t
e
W
r
i
t
e
Internally Generated Opcode (IOP)
Figure 24. Processor Instruction Pipeline
62
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Fetch
Inst 1
Inst 2
Decode
Inst 1
Execute
Inst 3
Inst 4
Inst 2
Inst 3
Inst 4
Inst 2
Inst 3
Inst 4
Inst 2
Inst 3
Inst 1
Write
Inst 1
CLK
A<31:0>
A1
D<31:0>
A2
A3
A4
Inst 1
Inst 2
Inst 3
Inst 4
Figure 25. Pipeline with All Single–Cycle Instructions
3.6.1.Stages
Instruction execution is broken into four stages corresponding to the stages of the pipeline:
2. Fetch—The processor outputs the instruction address to fetch the instruction.
3. Decode—The instruction is placed in the instruction register and decoded. The processor reads the operands from
the register file and computes the next instruction address.
4. Execute—The processor executes the instruction and saves the results in temporary registers. Pending traps are
prioritized and internal traps taken during this stage.
5. Write—If no trap is taken, the processor writes the result to the destination register.
All four stages operate in parallel, working on up to four different instructions at a time. A basic “single-cycle”
instruction enters the pipeline and completes in four cycles. By the time it reaches the write stage, three more
instructions have entered and are moving through the pipeline behind it. So, after the first four cycles, a single-cycle
instruction exits the pipeline and a single-cycle instruction enters the pipeline on every cycle (see Figure 25 ).
Of course, a “single-cycle” instruction actually takes four cycles to complete, but they are called single cycle because
with this type of instruction the processor can complete one instruction per cycle after the initial four-cycle delay.
3.6.1.1. Internal Opcodes
Instructions that require extra cycles automatically insert internal opcodes (IOPs) into the decode stage as they move
into the execute stage. These internal opcodes are unique to the instruction that generates them. They move all the way
through the pipeline, performing functions specific to the instruction that created them. For example, in Figure 26 ,
the data load in cycle four can be thought of as the fetch for the IOP that starts in cycle three; together they make a
complete four-cycle instruction that balances out the pipeline. JMPL and RETT also generate an IOP, but have no
external data cycle.
Multicycle instructions may generate up to three IOPs to complete execution. Table 43 lists the instructions that
require IOPs and the number generated.
Because instructions continue to be fetched even though IOPs occupy the decode stage, a two-stage prefetch buffer
is used to hold instructions until they can move into the decode stage (see Figure 24 ). This enables the processor to
fully utilize the data bus bandwidth and still keep the pipeline full. Only two buffers are required because a maximum
of two cycles are available for instruction fetching for any multicycle instruction.
MATRA MHS
Rev. H (02 Dec.96)
63
TSC691E
Table 43. Internally Generated Opcodes
Instruction
Number of Internal Opcodes
Single Loads
1
Double Loads
2
Single Store
2
Double Stores
3
Atomic Load-Store
3
Jump
1
Return from Trap
1
3.6.2. Multicycle Instructions
Multicycle instructions are those that take more than four cycles (one bus cycle plus the three pipeline cycles) to
complete. A double-cycle instruction takes five cycles (two bus cycles), a triple-cycle instruction takes six cycles (three
bus cycles), and so on.
In most cases, the extra cycles required by multicycle instructions result from data bus usage (e.g., a data load or store
to memory) that prevents the processor from fetching the next instruction during those cycles. In Figure 26 , the fetch
of instruction Inst 3 is delayed by one cycle for the data load, and in Figure 27 , the store sequence delays the Inst 3
fetch by two cycles.
Fetch
Load
Decode
Inst 1
Inst 2
Load Data
Inst 3
Inst 4
Load
IOP1
Inst 1
Inst 2
Inst 3
Load
IOP1
Inst 1
Inst 2
Load
IOP1
Inst 1
Execute
Write
CLK
A<31:0>
D<31:0>
LD
A1
A2
LD A
LD Inst
Inst 1
Inst 2
A3
Data
A4
Inst 3
DXFER
INST
Figure 26. Pipeline with One Double–Cycle Instruction (Load)
64
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Fetch
Store
Decode
Inst 1
Inst 2
Tag Check
Store Data
Inst 3
Store
IOP1
IOP2
Inst 1
Inst 2
Store
IOP1
IOP2
Inst 1
Store
IOP1
IOP2
Execute
Write
CLK
A<31:0>
ST
D<31:0>
A1
ST Inst
A2
ST A
Inst 1
Inst 2
ST A
Data
A3
Inst 3
RD
WE
DXFER
LOCK
WRT
INULL
INST
Figure 27. Pipeline with One Triple–Cycle Instruction (Store)
MATRA MHS
Rev. H (02 Dec.96)
65
TSC691E
Load
Fetch
Decode
Inst 4
Inst 1
Inst 2
Inst 3
IOPLd
IOPInt.
Inst 1
Inst 2
Load
IOPLd
IOPInt.
Inst 1
Inst 2
Load Data
Load
IOPLd
IOPInt.
Load
Execute
Write
ÍÍÍÍÍ
ÍÍÍÍÍ
Inst 3
Inst 1
CLK
A[31:0]
LD
D[31:0]
A1
LD Inst
A2
InstInst
1 1
LD A
A3
A3
A4
Inst 2
Data
---
Inst 3
DXFER
INULL
INST
Figure 28. Pipeline with Hardware Interlock (Load)
3.6.2.1. Register Interlocks
The pipeline holds several instructions at any given time, so it is possible that an instruction may try to use the contents
of a particular register which is in the process of being updated by a previous instruction. Special bypass paths in the
pipeline of the TSC691E make the correct data available to subsequent instructions for all internal register to register
operations, but cannot solve the problem of loads to the registers from external memory. For this case, interlock
hardware prevents an instruction following a load instruction from reading the register being loaded until the load is
complete (see Figure 28 ). This also applies to a CALL instruction with a delay slot instruction using r[15] and a JMPL
with a delay slot instruction using the same register specified as the r[rd] of the JMPL. To maximize performance,
compilers and assembly language programmers should avoid loads followed immediately by instructions using the
loaded register’s contents.
3.6.2.2. Branching
The TSC691E’s delayed-control-transfer mechanism allows branches (taken or untaken) to occur without creating a
bubble in the pipeline (see Figure 29 ). Special parallel hardware enables the processor to evaluate the condition codes
and calculate the effective branch address during the decode stage rather than the execute stage, so that only one delay
instruction is required between the branch and the target instruction (or the next instruction, if the branch is not taken).
See Section 3.4.3.3.1 for a discussion on branching.
If the compiler or programmer cannot place an appropriate instruction in the delay instruction slot, the delay instruction
can be annulled by setting the branch instruction’s a bit. The result is shown in Figure 30 .
66
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Fetch
Branch
Decode
Delay
Target
Inst 1
Inst 2
Inst 3
Inst 4
Branch
Delay
Target
Inst 1
Inst 2
Inst 3
Branch
Delay
Target
Inst 1
Inst 2
Branch
Delay
Target
Inst 1
Execute
Write
CLK
A[31:0]
Br A
D[31:0]
Delay A
Targ A
A1
A2
A3
A4
Br Inst
Dly Inst
Targ
Inst
Inst 1
Inst 2
Inst 3
Figure 29. Pipeline During Branch Instruction
Fetch
Branch
Decode
Delay
Target
Branch
Annulled
Branch
Execute
Inst 2
Inst 3
Inst 4
Target
Inst 1
Inst 2
Inst 3
Annulled
Target
Inst 1
Inst 2
Branch
Annulled
Target
Inst 1
Inst 1
Write
CLK
A[31:0] Br A
Delay A
Targ A
D[31:0
]
Br Inst
Dly
nst
A1
Targ
Inst
A2
A3
A4
Inst 1
Inst 2
Inst 3
Figure 30. Branch with Annulled Delay Instruction
MATRA MHS
Rev. H (02 Dec.96)
67
TSC691E
Fetch
Inst 1
Decode
Inst 0
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
Execute
Inst 2
Inst 3
Inst 1
Inst 1
Inst 1
Inst 1
Inst 1
Inst 2
Inst 0
Inst 0
Inst 0
Inst 0
Inst 0
Inst 1
Write
Inst 0
CLK
A[31:0]
A1
D[31:0] Inst 0
A2
Inst 1
A2
Inst 2
A3
Inst 2
BHOLD
DOE
AOE
Figure 31. Pipeline Frozen During Bus Arbitration
3.6.3. Pipeline Freezes
Whenever the processor receives an externally generated hold input, such as MHOLDA/B or BHOLD, the instruction
pipeline is frozen. How long it is frozen depends on the type of hold and the external hardware generating the hold.
Figure 31 shows the pipeline frozen by a BHOLD as the result of bus arbitration initiated by another bus master in
the system.
3.6.4. Traps
Figure 32 shows the pipeline operation when an internally generated trap is taken. Instructions in the pipeline after
detection of the trap are annulled and the first instruction of the trap target routine is executed in the fourth cycle
following detection.
3.7. Bus Operation and Timing
This section covers standard and non-standard bus operations. Standard operations include instruction fetch, load
integer, load double integer, load floating-point, load double floating-point, store integer, store double integer, store
floating-point, store double floating-point, atomic load-store unsigned byte, and floating-point operations (FPops).
Non-standard operations include bus arbitration, cache misses, exceptions, and the reset and error conditions.
Coprocessor loads, coprocessor stores, and coprocessor operations are identical in timing to their floating–point
counterpart, and are not repeated as a separate case in this section.
68
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Fetch
Inst 1
Decode
Inst 0
Execute
Trap 2
Trap 1
Annulled
Trap Detected
Write
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍÍ
ÍÍÍÍÍÍ
ÍÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
Trap 1
Annulled
Annulled
Annulled
Annulled
Trap 3
Trap 4
Trap 2
Trap 3
Trap 1
Trap 2
Annulled
Trap 1
CLK
A[31:0]
A1
A2
Trap A1
D[31:0]
Inst 0
Inst 1
Inst 2
Trap A2
Trap A3
Trap A4
Trap 1
Trap 2
Trap 3
INULL
INST
FLUSH
Figure 32. Pipeline Operation for Taken Trap (Internal)
Each of the following sections describes a type of bus transaction along with appropriate timing diagrams. The timing
diagrams show multiple instructions being fetched for the pipeline. Instruction addresses are sent out in the cycle before
the instruction fetch. Instruction fetch cycles begin with the instruction address latched by the memory at the beginning
of the fetch cycle and end with the instruction supplied by the memory. Instruction decode begins with the latching
of the instruction at rising clock edge of the cycle after the fetch cycle. If the instruction is multicycle, or execution
requires an interlock, IOPs are inserted into the pipeline at the decode stage and propagate through the pipeline like
a fetched instruction.
The cross-hatched areas shown in the traces are periods in which the signal is not guaranteed to be asserted or
deasserted; in other words, undefined.
In general, signals are valid at the beginning of a cycle, i.e., on the rising edge of the clock. In support of the TSC691E’s
high-speed operation, many signals are sent out unlatched. Refer to Section 3.5 for further details on TSC691E signals.
The processor automatically aligns byte (and halfword) transfers as previously shown in Figure 12 . Figure 33 shows
the relationship between the data transferred during byte, halfword, and word operations and the pins of the data bus.
For byte and halfword data transfers, the TSC691E repeats the byte or halfword on each eight–bit or 16–bit section
of the bus. In other words, the undefined portions of the bus illustrated in Figure 33 are actually a repeat of the data
driven onto the bus. However, this feature is not specified in the SPARC Architecture Reference, and may not be
supported on other SPARC processors.
MATRA MHS
Rev. H (02 Dec.96)
69
TSC691E
CLK
A<31:0>
SIZE<1:0>
X+0
0
X+1
X+2
X+3
0
0
0
D<31:24>
BYTE0
undef.
undef.
undef.
D<23:16>
undef.
BYTE1
undef.
undef.
D<15:8>
undef.
undef.
BYTE2
undef.
D<7:0>
undef.
undef.
undef.
BYTE3
Byte Data Alignment
CLK
A<31:0>
SIZE<1:0>
D<31:16>
D<15:0>
X+0
X+2
1
X
1
2
HWRD0
undef.
HWRD0
undef.
HWRD1
HWRD1
Half Word Data Alignment
Word Data Alignment
X = word boundary address
Note1: The parity bit of undef data in/out must match with the data
Note2 :This illustration depicts data alignment and is not intended to illustrate a timing case.
Figure 33. Data Bus Contents During Data Transfers
70
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
A2
A3
A4
A5
A6
D<31:0>
Inst 0
Inst 1
Inst 2
Inst 3
Inst 4
Inst 5
Figure 34. Instruction Fetch
1
2
3
4
5
6
CLK
A<31:0>
LD
D<31:0>
A1
LD Inst
A2
LD A
A3
A4
Inst 1
Inst 2
Data
Inst 3
DXFER
INST
Figure 35. Load Single Integer Timing
3.7.1. Instruction Fetch
The instruction fetch cycle is that cycle in which both the instruction address and the data (the instruction itself) are
active on their respective busses (see Figure 34 ). The instruction address on A<31:0> is actually sent out in the
previous cycle, but is held into the fetch cycle. It should be latched externally. The instruction is returned on the data
bus at the very end of the fetch cycle and is held into the decode cycle. It is latched into the on-chip instruction register
at the beginning of the decode cycle.
3.7.2. Load
Figure 35 shows the timing for a load single integer instruction. Because the bus is used for a data fetch in the fifth
cycle, this is a double-cycle instruction. Note that DXFER is active in the cycle in which the load data address is sent
out, while INST is inactive in the cycle in which the load data is on the data bus.
3.7.3. Load with Interlock
In a load with interlock situation, the instruction following the load tries to use the contents of the load’s destination
register before the load data is available. This requires the insertion of an IOP into the decode stage of the pipeline (see
Section 3.6.5.1) in the fourth cycle, which must be matched by a null bus cycle in the fetch stage to balance the pipeline
(see Figure 36 ).
MATRA MHS
Rev. H (02 Dec.96)
71
TSC691E
1
2
3
4
5
6
CLK
A[31:0]
LD
A1
A2
InstInst
1 1
LD Inst
D[31:0]
LD A
A3
Inst 2
Data
A3
A4
---
Inst 3
DXFER
INULL
INST
Figure 36. Load Single with Interlock Timing
1
2
3
4
6
5
CLK
A[31:0]
LD
D[31:0]
A1
LD Inst
A2
LD 1
LD 2
A3
A4
Inst 1
Inst 2
Data 1
Data 2
Inst 3
DXFER
LOCK
INST
Figure 37. Load Double Integer Timing
3.7.4. Load Double
The timing for a load double integer is shown in Figure 37 . The timing is essentially the same as a load single except
for the additional data fetch in the fifth cycle. That makes load double a triple-cycle instruction. The most-significant
word is fetched in cycle four and the least-significant word in cycle five. Note that the size bits are set to 11 during
the address portion of both loads and that the bus is locked to allow the completion of both loads without interruption.
Load single and load double floating-point instructions look identical to their integer counterparts except that the
FINS1/FINS2 signal is active for floating-point operations.
3.7.5. Store
Store transactions involve more bus activity than loads, as shown in the store single integer timing in Figure 38 . Store
single is a triple-cycle instruction because it includes an extra tag check cycle in which to check an external cache for
the store address. This extra cycle also gives the processor and the memory system time to three-state (on chip pull_up
resistor=20kΩ)the data bus and turn it around for the store. The store address is sent out again in the fifth cycle to
complete the data transfer. Note that the store data is generated by the processor off the falling edge of CLK and is
therefore only available at the very end of the first data cycle.
72
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Note also that INULL is active during the second application of the store address. If there is a cache miss on the tag
check cycle, INULL prevents an additional miss the second time the address is sent out in the store cycle. Because it
is a triple– cycle instruction, LOCK is asserted to retain control of the busses.
1
2
3
4
5
6
CLK
A<31:0>
ST
D<31:0>
A1
A2
ST A
ST Inst
Inst 1
Inst 2
ST A
ST Data
A3
A4
Inst 3
RD
WE
DXFER
LOCK
WRT
INULL
INST
Figure 38. Store Single Integer Timing
3.7.6. Store Double
The timing for a store double integer is shown in Figure 39 . The timing is essentially the same as store single except
for the additional store cycle in the sixth cycle, making it a four-cycle instruction. The most-significant word is stored
in cycle five and the least-significant word in cycle six. Note that the size bits are set to 11 during the address portion
of all three data cycles and that the bus is locked to allow the completion of both stores without interruption. INULL
is not active for the address of the least-significant store because there cannot be a miss on this cycle if there wasn’t
one on the tag check cycle, unless the cache line is less than two words.
Store single and store double floating-point instructions look identical to their integer counterparts except that the
FINS1/FINS2 signal is active for floating-point operations.
MATRA MHS
Rev. H (02 Dec.96)
73
TSC691E
1
2
3
4
5
6
CLK
A<31:0>
D<31:0>
ST D
A1
ST Inst
A2
ST A1
Inst 1
Inst 2
ST A1
ST D1
ST A2
A3
ST D2
RD
WE
DXFER
LOCK
WRT
INULL
INST
Figure 39. Store Double Integer Timing
3.7.7. Atomic Load–Store
Atomic transactions consist of two or more steps which are indivisible; once the sequence begins in the instruction
pipeline, it cannot be interrupted. Because atomic operations are four-cycle instructions, the TSC691E asserts LOCK
for as long as necessary to make sure that no interruption occurs on the bus. Figure 40 applies to the atomic operations
load-store unsigned byte (LDSTUB, LDSTUBA) and word swap (SWAP, SWAPA). Note that, as with any store,
INULL is active on the second occurrence of the store address.
74
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
1
2
3
4
5
6
CLK
A<31:0>
D<31:0>
A1
LDSTO
Inst.
A2
LD A
Inst 1
Inst 2
ST A
ST A
Load
Data
Store Data
A3
A4
Inst 3
RD
WE
LDSTO
DXFER
LOCK
WRT
INULL
INST
Figure 40. Atomic Load–Store Timing
3.7.8. Floating-Point Operations
The timing for floating-point operations and integer operations is the same except for the addition of the FINS1 and
FINS2 signals in floating-point operations. In this example, Instruction 1 is a floating-point operation (see Figure 41 ).
FINS1/2 tell the floating-point unit to move an instruction out of its decode buffer and begin execution. The FPU also
makes use of the INST signal to latch instructions into its decode buffers.
MATRA MHS
Rev. H (02 Dec.96)
75
TSC691E
1
2
3
4
CLK
A<31:0>
A1
A2
A3
A4
A5
ASI<7:0>
ASIA1
ASIA2
ASIA3
ASIA4
ASIA5
D<31:0>
--
FPop
Inst 2
Inst 3
Inst 4
SIZE<1:0>
10
10
10
10
10
FINS1/FINS2
Figure 41. Floating–Point Operation Timing
3.7.9. Bus Arbitration
The TSC691E does not have on-chip bus arbitration circuitry because it is designed to operate as a bus slave. Therefore,
external circuitry must arbitrate between external bus requests and the TSC691E. When the TSC691E needs to retain
the busses it asserts the LOCK signal. The arbitration circuitry should assert BHOLD when it needs to keep the
TSC691E off the busses. When BHOLD is asserted, the processor’s instruction pipeline is frozen until it is deasserted.
The arbitration circuitry should also deassert the DOE, AOE, and COE signals to three-state the TSC691E’s address
bus (on chip pull_up resistor=20kΩ), data bus and control signal output drivers so they may be driven by an external
source (see Figure 42 ).
76
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
1
2
3
4
5
6
CLK
A<31:0>
A1
A2
A2
A3
ASI<7:0>
ASIA1
AS–A2
ASIA2
ASIA3
D<31:0>
Inst 0
Inst 1
--
Inst 2
10
10
10
SIZE<1:0>
10
RD
WE
LDSTO
DXFER
LOCK
WRT
BHOLD
DOE
AOE
COE
Figure 42. Bus Arbitration Timing
3.7.10. Load with Cache Miss
Figure 43 gives the timing for a load with cache miss. Cache logic must stop the processor by asserting MHOLDA
or MHOLDB in the next cycle. However, the processor stops with the address of the next instruction on the address
bus rather than the instruction that caused the miss. In order to retrieve the proper load data, the memory system needs
the missed address on the bus. To do this the memory system must send an MAO signal, forcing the processor to output
the previous address (the address that was on the bus in the cycle before MHOLD was asserted). The MHOLD signal
must be maintained while the missed data is strobed into the processor with the MDS signal (it must be strobed
externally because the internal processor clock is frozen by the MHOLD).
MATRA MHS
Rev. H (02 Dec.96)
77
TSC691E
1
2
3
4
5
6
7
CLK
A<31:0>
A1
ASI<7:0> ASIA1
D<31:0> LD Inst
SIZE<1:0>
10
A2
LD A
A3
A3
LD A
A3
ASIA2
ASILD
ASIA3
ASIA3
ASILD
ASIA3
Inst 1
Inst 2
Data
--
10
10
10
LD size
--
LD size
Data
10
DXFER
MHOLD
MDS
MAO
INST
Figure 43. Load with Cache Miss Timing
3.7.11. Store with Cache Miss
The timing for a store with cache miss is similar to the load with cache miss situation, except that MAO and MDS are
not required (see Figure 44 ). Because the processor outputs the store address twice, it already has the proper address
on the bus when it’s stopped by MHOLD. MDS is not required because nothing needs to be strobed into the processor.
INULL is asserted for the second occurrence of the store address so that it doesn’t trigger the miss circuitry during the
time the cache is processing the miss on the first occurrence of that address.
78
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
ASI<7:0>
D<31:0>
SIZE<1:0>
A2
ST A
ASIA1
ASIA2
ASIST
Inst 0
Inst 1
Inst 2
10
10
ST Size
ST A
ASIST
ST A
ASIST
ST Data
ST Size
ST Size
RD
WE
DXFER
LOCK
WRT
INULL
MHOLD
INST
Figure 44. Store with Cache Miss Timing (1 of 2)
MATRA MHS
Rev. H (02 Dec.96)
79
TSC691E
6
7
8
9
10
CLK
A<31:0>
ST A
A3
A4
A5
ASI<7:0>
ASIST
ASIA3
ASIA4
ASIA5
ASIA6
Inst 3
Inst 4
Inst 5
10
10
10
D<31:0>
ST Data
SIZE<1:0>
ST Size
10
A6
RD
WE
DXFER
LOCK
WRT
INULL
MHOLD
INST
Figure 45. Store with Cache Miss Timing (2 of 2)
3.7.12. Load/Store instruction with Trap
Figure 46 gives the timing for a load instruction with a trap taken. This timing is similar for the load double, for the
load-store, for the store and for the swap instructions.
80
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
1
2
3
4
5
6
CLK
A<31:0>
LD
D<31:0>
A1
LD Inst
A2
LD A
Trap A1
Trap A2
Inst 1
Inst 2
----
Trap 1
DXFER
INST
INULL
FLUSH
Figure 46. Ld, LdSt, St and Swap Inst with Trap Taken
3.7.13. Memory Exceptions
Load with memory exception timing is shown in Figure 48 . As with a cache miss, memory logic must stop the
processor by asserting MHOLDA or MHOLDB in the next cycle. The MHOLD signal must be maintained while the
memory exception (MEXC) signal is strobed into the processor with the MDS signal (it must be strobed in externally
because the internal processor clock is frozen by the MHOLD). MEXC must be deasserted in the same clock cycle in
which MHOLD is deasserted. Note that INULL is asserted in the cycle 8 instruction fetch to annul that fetch. This is
the same action shown in cycle 2 of Figure 32 for an internal trap. Store with memory exception has the same timing
(see Figure 52 ) except INULL is asserted from the second store address through to the annulled cycle 8 instruction
fetch.
MATRA MHS
Rev. H (02 Dec.96)
81
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
A2
ASI<7:0>
ASIA1
ASIA2
ASILD
ASIA3
ASIA3
D<31:0>
LD Inst
Inst 1
Inst 2
Data
--
10
10
LD size
10
10
SIZE<1:0>
LD A
A3
A3
-
DXFER
MHOLD
INULL
MDS
MEXC
INST
FLUSH
Figure 47. Load with Memory Exception Timing (1 of 2)
82
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
6
7
8
9
CLK
SIZE<1:0>
ASIA4
ASIA3
ASI<7:0>
D<31:0>
A4
A3
A<31:0>
--
--
10
A TB
A T1
ASITB
ASIT1
--
10
--
10
TB Inst
10
DXFER
MHOLD
R17 = ADD (LD Inst)
R18 = ADD (LD Inst) + 4
INULL
MDS
MEXC
INST
FLUSH
Figure 48. Load with Memory Exception Timing (2 of 2)
MATRA MHS
Rev. H (02 Dec.96)
83
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
A2
D<31:0>
Inst 0
Inst 1
IAE
Inst 2
A3
A3
I_fail
--
-
MHOLD
INULL
MDS
MEXC
INST
FLUSH
6
7
8
9
CLK
A3
A<31:0>
D<31:0>
MHOLD
--
--
A4
A5
Trap 1
Trap 2
Inst3
Inst4
---
Trap 1
R17 = IAE
R18 = A3
INULL
MDS
MEXC
INST
FLUSH
Figure 49. Instruction Memory Access Exception Timing
84
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
1
2
3
4
5
CLK
A<31:0>
LD
A1
D<31:0>
Inst 0
LD
IAE
LD add
Inst 1
I fail
LD add
--
-
DXFER
MHOLD
INULL
MDS
MEXC
INST
FLUSH
6
7
8
10
9
CLK
LD add
A<31:0>
D<31:0>
MHOLD
--
A3
--
Data
A4
Inst 3
A5
Inst45
TRAP
---
R17 = IAE
R18 = A3
DXFER
INULL
MDS
MEXC
INST
FLUSH
Figure 50. Instruction Memory Access Exception Timing (LD in Execute stage)
MATRA MHS
Rev. H (02 Dec.96)
85
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
A2
ST A
ST A
ST A
ASIST
ASIST
ASI<7:0>
ASIA1
ASIA2
ASIST
D<31:0>
ST Inst
Inst 1
Inst 2
10
10
ST Size
SIZE<1:0>
ST Data
ST Size
ST Size
RD
WE
DXFER
LOCK
WRT
INULL
MHOLD
MDS
MEXC
INST
FLUSH
Figure 51. Store with Memory Exception Timing (page 1 of 2)
86
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
6
7
8
9
CLK
A<31:0>
ST A
A3
A TB
A T1
ASI<7:0>
ASIST
ASIA3
ASITB
ASIT1
D<31:0>
ST Data
SIZE<1:0>
ST Size
---
10
10
TB Inst
10
RD
WE
R17 = Add Store
R18 = Add Store + 4
DXFER
LOCK
WRT
INULL
MHOLD
MDS
MEXC
INST
FLUSH
Figure 52. Store with Memory Exception Timing (page 2 of 2)
MATRA MHS
Rev. H (02 Dec.96)
87
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
A2
ST A
ST A
ST A
ASIST
ASIST
ASI<7:0>
ASIA1
ASIA2
ASIST
D<31:0>
ST Inst
Inst 1
Inst 2
10
10
ST Size
SIZE<1:0>
ST Data
ST Size
ST Size
RD
WE
DXFER
LOCK
WRT
INULL
MHOLD
MDS
MEXC
INST
FLUSH
Figure 53. Store double with Memory Exception on 1st data address (page 1 of 2)
88
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
6
7
8
9
CLK
A<31:0>
ST A
ST A+4
A TB
A T1
ASI<7:0>
ASIST
ASI St
ASITB
ASIT1
D<31:0>
ST Data
SIZE<1:0>
ST Size
---
10
10
TB Inst
10
RD
WE
R17 = Add Store
R18 = Add Store + 4
DXFER
LOCK
WRT
INULL
MHOLD
MDS
MEXC
INST
FLUSH
Figure 54. Store double with Memory Exception on 1st data address (page 2 of 2)
MATRA MHS
Rev. H (02 Dec.96)
89
TSC691E
1
2
3
4
5
CLK
A<31:0>
A1
A2
ST A1
ST A1
ST A2
ASI<7:0>
ASIA1
ASIA2
ASIST
ASIST
ASIST
D<31:0>
ST Inst
Inst 1
Inst 2
10
10
ST Size
SIZE<1:0>
A3
ASIA3
Store DATA
ST Size
ST Size
Inst 3
ST Size
RD
WE
DXFER
LOCK
WRT
INULL
MHOLD
MDS
MEXC
INST
FLUSH
Figure 55. Store double with Memory Exception on 2nd data address (page 1 of 2)
90
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
6
7
8
9
CLK
A<31:0>
ASI<7:0>
D<31:0>
SIZE<1:0>
A3
ASI A3
A4
A TB
A T1
ASIA4
ASITB
ASIT1
--
TB Inst
Inst 3
10
10
10
10
RD
WE
R17 = Add Store
R18 = Add Store + 4
DXFER
LOCK
WRT
INULL
MHOLD
MDS
MEXC
INST
FLUSH
Figure 56. Store double with Memory Exception on 2nd data address (page 2 of 2)
MATRA MHS
Rev. H (02 Dec.96)
91
TSC691E
CLK
FEXC
FXACK
FLUSH
Figure 57. Floating–Point Exception Handshake Timing
1
2
3
4
6
5
CLK
A<31:0>
A1
A2
D<31:0>
Inst 0
Inst 1
IRL<3:0>
0H
A3
Inst 2
A4
T0
T1
Inst 3
Inst 4
Trap 0
Interrupt Asserted
Don’t care until RETT
INTACK
Figure 58. Asynchronous Interrupt Timing
3.7.14. Floating-Point Exceptions
The floating–point unit asserts FEXC to notify the TSC691E that a floating-point exception has occurred and that it
should take a trap on the next floating-point instruction that it encounters in the instruction stream (see Figure 57 ).
The TSC691E asserts FXACK to signal the FPU that the trap is being taken, and FLUSH to clean out the FPU’s decode
buffers. From this point on, the FPU will execute only floating-point store queue instructions until its queue is emptied
by the trap handler.
FEXC is deasserted by the FPU after FXACK is asserted. FXACK is deasserted by the TSC691E after FEXC is
deasserted.
3.7.15. Interrupts
The asynchronous IRL<3:0> inputs are sampled on the rising edge of every clock. If the interrupt value represented
by those inputs is greater than the masking value in the processor, and no higher priority trap supersedes it, the
TSC691E will take the interrupt. The IRL input level should be held stable until the processor asserts INTACK.When
the trap is taken, IRL line are ignored until ET=0 (until RETT instruction is executed). Figure 58 shows the timing
92
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
for the best case response time where the IRL input value is asserted one clock and a set–up time before the execute
stage of a single-cycle instruction. Refer to Section 3.8.3 for more information on interrupts.
CLK
A<31:0>
ASI<7:0>
D<31:0>
SIZE<1:0>
0000 H
0000 H
A1
09 H
09 H
ASI 1
--
--
Inst 0
10
10
10
INULL
RESET
MHOLD
MAO
Figure 59. Power–On Reset Timing
3.7.16. Reset Condition
Figure 59 shows the timing for a power-on reset. RESET must be asserted for at least nine cycles so that the processor
can synchronize the reset input and initialize its internal state. For RESET to be synchronized, the CLK signal must
be active.
During the initialization, the processor disables traps (ET=0), sets the supervisor mode (S=1), and sets the program
counter to location zero (PC=0, nPC=4).
3.7.17. Error Condition
error mode is one of the three states in which the TSC691E can exist. To get into this error mode, a synchronous trap
must occur while traps are disabled (the processor state register’s ET bit is set to zero). This essentially means that a
trap which cannot be ignored occurs while another trap is being serviced. In order for that synchronous trap to be
serviced, the processor goes through the normal operations of a trap (see Section 3.8), including setting the tt bits to
identify the trap type. It then enters error mode, halts, and asserts the ERROR signal (see Figure 60 ).
The only way to leave error mode is to receive an external RESET signal, which forces the processor into reset mode.
All information placed in the TSC691E’s registers from the last execute mode (the trap operation) remains unchanged
and the processor resumes operation at address zero. The reset trap handler can examine the trap type of the
synchronous trap and deal with it accordingly.
MATRA MHS
Rev. H (02 Dec.96)
93
TSC691E
1
2
3
4
6
5
7
CLK
D<31:0>
T.Ints
A<31:0>
A.Ints
+4
Trap Add
Trap Add + 4
*
INST
*
INULL
FLUSH
ERROR
RESET*
T.Inst = Traping Instruction
* If T.Inst is a control transfert instruction
RESET must be asserted for a minimum of 9 clocks
Figure 60. Error/Reset Timing
(continued)
1
2
3
4
8
9
CLK
----
D<31:0
>
A<31:0>
ASI
Trap Add + 4
Inst 0
A=0000 H, SIZE=01
ASI
0004 H
ASI=09 H
INST
INULL
FLUSH
ERROR
RESET*
94
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
Table 44. Externally Generated Synchronous Exception Traps
Trap
Initiating Signal
Condition
Data Access Exception
MEXC
Memory error during data access
Instruction Access Exception
MEXC
Memory error during instruction access
Floating–Point Exception
FEXC
Floating–point unit error
Coprocessor Exception
CEXC
Coprocessor unit error
3.8. Exception Model
The TSC691E supports three types of traps: synchronous, floating-point/coprocessor, and asynchronous (also called
interrupts). Synchronous traps are caused by hardware responding to a particular instruction or by the Trap on integer
condition code (Ticc) instructions; they occur during the instruction that caused them.
Floating–point/coprocessor traps caused by a Floating-Point-operate (FPop) or CoProcessor-operate (CPop)
instruction occur before that instruction is complete. However, because floating–point (and coprocessor) exceptions
are pended until the next floating–point (coprocessor) instruction is executed, other non-floating-point (coprocessor)
instructions may have executed before the trap is taken.
Asynchronous traps occur when an external event interrupts the processor. They are not related to any particular
instruction and occur between the execution of instructions. See Section 3.8.3.
3.8.1. Reset
The reset trap is a special case of the external asynchronous trap type. It is asynchronous because it is triggered by
asserting the RESET input signal. But from that point on, its behavior is entirely different from that of an asynchronous
interrupt (see Section 3.8.3).
As soon as the TSC691E recognizes the RESET signal, it enters reset mode and stays there until the RESET line is
deasserted. The processor then enters execute mode and then the execute trap procedure. Here, it deviates from the
normal action of a trap (Section 3.8.5) by modifying the enable traps bit (ET=0), and the supervisor bit (S=1). It then
sets the PC to 0 (rather than changing the contents of the TBR), the nPC to 4, and transfers control to location 0. All
other PSR fields, and all other registers retain their values from the last execute mode.
Note : Upon power-up reset the state of all registers other than the PSR are undefined.
If the processor got to reset mode from error mode, then the normal actions of a trap have already been performed,
including setting the tt field to reflect the cause of the error mode. Because this field is not changed by the reset trap,
a post-mortem can be conducted on what caused the error mode. The processor enters error mode whenever a
synchronous trap occurs while traps are disabled.
3.8.2. Synchronous Traps
Synchronous traps are caused by the actions of an instruction, with the trap stimulus occurring either internally to the
TSC691E or from an external signal which was provoked by the instruction. These traps are taken immediately and
the instruction that caused the trap is aborted before it changes any state in the processor.
A new type of trap has been added: Hardware traps. This trap occurs when a hardware error (i.e. SEU[1] on register)
is detected by the IU. The trap type depends of the internal parity error (see Table 47 , page 116). In case of hardware
traps the HWERROR signal is asserted low.
The external signals that can cause a synchronous trap are listed in Table 44 .
3.8.2.1. External Signals
Synchronous traps generated by the input signal MEXC (Memory Exception) occur during the execute phase of an
instruction or occur immediately for data accesses. Traps generated by the FEXC and CEXC signals belong to the
special floating-point/coprocessor category, and may not occur immediately.
Note 1 : SEU = Single Event Upset, a flip of register or memory cells, forced by heavy ions.
MATRA MHS
Rev. H (02 Dec.96)
95
TSC691E
3.8.2.2. Hardware error
When a hardware error is detected, the trap handling routine saves the error information which the MEC has sampled.
The trap routine then resumes the instruction by returning from the trap routine. If the cause of the error was a transient
fault, it may be removed by just resuming the instruction. If the error was caused by a fault that is not removable by
resuming the instruction, another hardware error trap is generated and the trap handling routine propagates the error
to a higher level of the application.
If the fault is in a critical register or latch which the trap handling routine uses, another hardware error trap is generated.
A synchronous trap during the time when traps are disabled is a critical error and the IU enters the error mode and halts.
This means that the error detection mechanism has to detect the error when the faulty instruction is in the execute stage
in order to handle the trap normally, i.e. correct PC for the faulty instruction.
When an error trap occurs, the HWERROR signal is asserted (see Table 47 , page 116).
3.8.2.3. Instruction access exception
An instruction access exception trap is generated if a memory exception occurs (the MEXC input signal is asserted)
during an instruction fetch.
3.8.2.4. Data access exception
A data access exception trap is generated if a memory exception occurs (the MEXC input signal is asserted) during
the data cycle of any instruction that moves data to or from memory.
3.8.2.5. Internal/Software
Synchronous traps generated by internal hardware are associated with an instruction. The trap condition is detected
during the execute stage of the instruction and the trap is taken immediately, before the instruction can complete.
3.8.2.6. Illegal instruction
An illegal instruction trap occurs:
D when the UNIMP instruction is encountered,
D when an unimplemented instruction is encountered (excluding FPops and CPops),
D in any of the situations below where the continued execution of an instruction would result in an illegal processor
state:
1. Writing a value to the PSR’s CWP field that is greater than the number of implemented windows (with a
WRPSR)
2. Executing an Alternate Space instruction with its i bit set to 1
3. Executing a RETT instruction with traps enabled (ET=1)
4. Executing an IFLUSH instruction with IFT=0
Unimplemented floating-point and unimplemented coprocessor instructions do not generate an illegal instruction trap.
They generate fp exception and cp exception traps, respectively.
Floating-point instructions are coded with : op=10 & op3=11010x
Coprocessor instructions are coded with : op=10 & op3=11011x
The IU decodes the fields op and op3 and generates FINS’s or CINS’s even if the instruction is unimplemented.
3.8.2.7. Privileged instruction
This trap occurs when a privileged instruction is encountered while the PSR’s supervisor bit is reset (S=0).
3.8.2.8. Fp disabled
A fp disabled trap is generated when an FPop, FBfcc, or floating-point load/store instruction is encountered while the
PSR’s EF bit =0, or if no FPU is present (FP input signal =1).
3.8.2.9. Cp disabled
A cp disabled trap is generated when a CPop, CBccc, or coprocessor load/store instruction is encountered while the
PSR’s EC bit =0, or if no coprocessor is present (CP input signal =1).
96
MATRA MHS
Rev. H (02 Dec.96)
TSC691E
3.8.2.10. Window overflow
This trap occurs when the continued execution of a SAVE instruction would cause the CWP to point to a window
marked invalid in the WIM register.
3.8.2.11. Window underflow
This trap occurs when the continued execution of a RESTORE instruction would cause the CWP to point to a window
marked invalid in the WIM register. The window underflow trap type can also be set in the PSR during a RETT
instruction, but the trap taken is a reset. See Section 3.8.1 on reset traps and SPARC V7.0 Instruction Set for the
instruction definition for RETT.
3.8.2.12. Memory address not aligned
Memory address not aligned trap occurs when a load or store instruction generates a memory address that is not properly
aligned for the data type or if a JMPL instruction generates a PC value that is not word aligned (low-order two bits
nonzero).
3.8.2.13. Tag overflow
This trap occurs if execution of a TADDccTV or TSUBccTV instruction causes the overflow bit of the integer condition
codes to be set. See the instruction definitions of TADDccTV and TSUBccTV and Section 3.4.3.2.3 for details.
3.8.2.14. Trap instruction
This trap occurs when a Ticc instruction is executed and the trap conditions are met. There are 128 programmable trap
types available within the trap instruction trap (see SPARC V7.0 Instruction Set, Ticc instruction).
MATRA MHS
Rev. H (02 Dec.96)
97
TSC691E
3.8.3. Interrupts (Asynchronous Traps)
Asynchronous traps occur in response to the Interrupt Request Level (IRL<3:0>) inputs. This type of trap is not
associated with an instruction and is said to happen between instructions. This is because, unlike synchronous traps,
an interrupt allows the instruction in whose execute stage it is prioritized to complete execution (see Figure 61 ). Any
instruction that has entered the pipeline behind the instruction which was allowed to complete is annulled, but can be
restarted again after returning from the trap.
3.8.3.1. Priority
The level, or priority, of the interrupt is determined by the value on the IRL<3:0> pins. For the interrupt to be taken,
the IRL value must be greater than the value in the Processor Interrupt Level (PIL) field of the Processor State Register
(PSR). A value of 0 indicates that no interrupt is requested. A value of 15 represents a non-maskable interrupt. All other
IRL values between 0 and 15 represent interrupt requests which can be masked by the PIL field. The priority and trap
type (tt) for each level is shown in Table 45 .
Fetch
Inst 2 -> r17
Inst 3 -> r18
Inst 4
Inst 1
Inst 2
Inst 3
Inst 1
Inst 2
Decode
Execute
Write
ÍÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍ
Trap 1
Trap 2
Annulled
Trap 1
Annulled
Annulled
Annulled
Inst 1
Annulled
Annulled
IRL<3:0>
Taken
Prioritized
Latched
Sampled
INTACK
Figure 61. Best–Case Interrupt Response Timing (one cycle instruction)
Fetch
Decode
Execute
Load
Inst 1
Inst 2
ÍÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍ
Load
Data
Inst 3
Trap 1
-> r17
-> r18
Load
IOP1
Inst 1
Inst 2
Annulled
Load
IOP1
Inst 1
Annulled Annulled
Load
IOP1
Annulled Annulled
Write
IRL<3:0>
Tag
Check
Trap 2
Trap 3
Trap 1
IOP1
IOP2
Trap 1
IOP1
Trap 1
Annulled
Taken
Prioritized
Latched
Sampled
INTACK
Figure 62. Double Cycles Instruction Interrupt Response Timing (ex: Load)
98
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Store
Fetch
Inst 1
Inst 2
-> r17 -> r18
Store
Decode
Tag
Check
Store
Data
Inst 3
IOP2
Inst 1
Inst 2
IOP1
IOP2
Inst 1
IOP1
IOP2
IOP1
Store
Execute
Store
Write
IRL<3:0>
ÍÍÍ
ÍÍÍ
ÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍ
Trap 1
Annulled
Trap 2
Trap 3
Tag
Check
Trap 1
IOP1
IOP2
Trap 1
IOP1
Annulled Annulled
Annulled Annulled Annulled
Trap 1
Taken
Prioritized
Latched
Sampled
INTACK
ÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍÍ
ÍÍÍ
ÍÍÍ
ÍÍÍ
ÍÍÍ
Figure 63. Triple-Cycles Instruction Interrupt Response Timing (ex: Store)
Fetch
Store
double
Inst 1
Store
D1
Store
D2
Inst 3
IOP1
IOP2
IOP3
Inst 1
Inst 2
Annulled
Store
double
IOP1
IOP2
IOP3
Inst 1
Annulled Annulled
Store
double
IOP1
IOP2
IOP3
-> r17 -> r18
Store
double
Decode
Tag
Check
Inst 2
Execute
Write
IRL<3:0>
Trap 1
Trap 2
Trap 3
Tag
Check
Trap 1
IOP1
IOP2
Trap 1
IOP1
Annulled Annulled Annulled
Trap 1
Taken
Prioritized
Latched
Sampled
INTACK
Figure 64. Four-Cycles Instruction Interrupt Response Timing (Store Double)
3.8.3.2. Response Time
The TSC691E samples the IRL inputs at the rising edge of every clock. In order to properly synchronize these
asynchronous inputs, they are put through two synchronizing levels of D-type flip-flops. The outputs of the two levels
must agree before the interrupt can be processed. If the outputs disagree, the interrupt request is ignored. This logic
serves to filter transients on the IRL lines, but it means that the lines must be active for two consecutive clock edges
to be accepted as valid.
Once the IRL input has been accepted, it is prioritized and the appropriate trap is taken during the next execute stage
of the instruction pipeline. Best case interrupt response occurs when the interrupt is applied one clock plus one setup
time before the execute phase of any instruction in the pipeline (see Figure 61 ). In this case, the first instruction of
the interrupt service routine is fetched during the fifth clock following the application of an IRL value greater than the
PIL field of the processor status register (PSR). This also holds for an IRL value of 0F H, which acts as a non–maskable
interrupt.
The worst case interrupt response occurs when the detection of the IRL input just misses the cutoff point for the execute
stage of a four-cycle instruction, such as a store double or atomic load-store (see Figure 63 ). In this case, the interrupt
MATRA MHS
Rev. H (02 Dec. 96)
99
TSC691E
input must wait an additional three cycles for the next pipeline execute phase. In addition, if the IRL input just misses
the sampling clock edge, an additional clock delay occurs. As a result, the first instruction of the service routine is
fetched in the eighth clock following the application of IRL.
The best and worst case interrupt timing described above assumes that the processor is not stopped via the application
of an external hold signal, and that the IRL input is not superceded by the occurrence of a synchronous (internal) trap.
3.8.3.2.1. Instruction Response Time on conditional branch instruction (CBI)
When the instruction present in the decode stage during sampling of IRL<3:0> is a CBI, the response time is the same
than described in Figure 61 except when the delay instruction is annulled:
1_ BA, FBA, and CBA with annul bit = 1 (B*A,a)
2_ Bicc, FBicc, and CBicc not taken with annul bit = 1 (B*cc,aNT)
For those two cases, the INTACK signal and the first instruction of the interrupt service routine will be valid one cycle
later (see Figure 65 , page 106).
Fetch
Delay Inst
Decode
CBI
Execute
Target
Inst 1
-> R17
-> R18
Annulled
Target
Inst 1
Annulled
Target
CBI
Write
CBI
Inst 2
Annulled
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍÍÍ
ÍÍÍ
ÍÍÍÍÍ
ÍÍÍ
Trap 2
Trap 1
Trap 1
Annulled
Annulled
Annulled
Annulled
Annulled
Annulled
IRL<3:0>
Taken
Prioritized
Latched
Sampled
INTACK
Figure 65. Interrupt Response Timing on conditional branch instruction (B*A,a & B*cc,aNT)
3.8.3.3.Interrupt Acknowledge
As shown in Figure 61 ,Figure 65 and more clearly in Figure 63 , the INTerrupt ACKnowledge (INTACK) output
signal is asserted when the interrupt is taken, not when it is first detected and latched. Because of this delay, if the
IRL<3:0> inputs are changed to reflect another interrupt condition before the corresponding INTACK for the latched
condition is received, there could be some question as to which interrupt the INTACK is responding to. Therefore,
external hardware should ensure that the IRL<3:0> inputs are held stable until an INTACK is received.
When trap is taken the PC and nPC are saved into r[17] and r[18] respectively see Figure 61 , Figure 63 and
Figure 65 .Care must be taken in case of Response Timing on conditional branch instruction (B*A,a & B*cc,aNT),
the PC value of inst1 instead of the Delay Instruction is saved in r17. If Branch is taken, r17 and r18 contain the 2 first
addresses of the branch routine.
For the Best–Case Interrupt Response Timing (Figure 61 ), r18 contains the value of the first address of the branch
routine if inst1 if a Branch instruction (different than B*A,a & B*cc,aNT).
3.8.4. Floating-Point/Coprocessor Traps
Floating-point/coprocessor exception traps are considered a separate class of traps because they are both synchronous
and asynchronous. They are asynchronous because they are triggered by an external signal (FEXC or CEXC), and are
taken sometime after the floating-point or coprocessor instruction that caused the exception. This can happen because
the TSC691E and the FPU (coprocessor) operate concurrently. However, they are also synchronous, because they are
100
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
tied to an instruction—the next floating-point or coprocessor instruction encountered in the instruction stream after
the signal is received.
When the FPU (coprocessor) recognizes an exception condition, it enters an “exception pending mode” state. It
remains in this state until the TSC691E signals that it has taken an fp exception (cp exception) trap by sending back
an FXACK (CXACK) signal. The FPU (coprocessor) then enters the “exception mode” state, remaining there until
the floating-point (coprocessor) queue has been emptied by execution of one or more STDFQ (STDCQ) instructions.
Although the PC will always point to a floating-point or coprocessor instruction after an exception trap is taken, it
doesn’t point to the instruction that caused the exception. However, the instruction that did cause the exception is
always the front entry in the queue at the time the trap is taken, and the entry includes both the instruction and its
address. The remaining entries in the queue point to FPops (CPops) that have been started but have not yet completed.
Once the queue has been emptied, these can be re-executed or emulated.
3.8.4.1. Floating-Point Exception
This trap occurs when the FPU is in exception pending mode and an FPop, FBfcc, or floating-point load/store
instruction is encountered. The type of exception is encoded in the tt field of the Floating-point State Register (FSR).
3.8.4.2. Coprocessor Exception
This trap occurs when the Coprocessor is in exception pending mode and a CPop, CBccc, or coprocessor load/store
instruction is encountered. The type of exception should be encoded in the tt field of the Coprocessor State Register
(CSR). The nature of the exception is implementation dependent.
3.8.5. Trap Operation
Once a trap is taken, the following operations take place:
D Further traps are disabled (asynchronous traps are ignored; synchronous traps force an error mode).
D The S bit of the PSR is copied into the PS bit; the S bit is then set to 1.
D The CWP is decremented by one (modulo the number of windows) to activate a trap window.
D The PC and nPC are saved into r[17] and r[18], respectively, of the trap window.
D The tt field of the TBR is set to the appropriate value.
D If the trap is not a reset, the PC is written with the contents of the TBR and the nPC is written with TBR + 4. If the
trap is a reset, the PC is set to address zero and the nPC to address four.
Unlike many other processors, the SPARC architecture does not automatically save the PSR into memory during a trap.
Instead, it saves the volatile S bit into the PSR itself and the remaining fields are either altered in a reversible manner
(ET and CWP), or should not be altered in the trap handler until the PSR has been saved to memory.
3.8.5.1. Recognition
In most cases, traps are “recognized” in the pipeline’s execute stage. For a synchronous trap, the trap criteria are
examined during the execute stage of an instruction, and the trap is taken immediately, before the write stage of that
instruction takes place. This includes the fp disabled and cp disabled trap type. The special cases occur with those traps
generated by external signals. A memory exception on an instruction fetch is detected at the beginning of the execute
stage of instruction execution. Memory exceptions occurring on data accesses are detected on the rising clock edge
of the data cycle.
Because asynchronous traps happen “between” instructions, their timing is slightly different. As long as the ET bit is
set to one, the TSC691E checks for interrupts. The interrupt is sampled on a rising clock edge and latched on the next
rising clock edge. The processor compares the IRL<3:0> input value against the PIL field of the PSR, and if IRL is
greater than PIL, or IRL is 15 (unmaskable), then it is prioritized at the end of the next execute stage of the pipeline.
A trap keyed to the IRL level occurs after the write stage completes.
Floating-point/coprocessor exception traps are not recognized when the FEXC or CEXC signal is first sampled. The
processor waits until it encounters a floating-point or coprocessor instruction in the instruction stream and then handles
it as if it were an internal synchronous trap.
MATRA MHS
Rev. H (02 Dec. 96)
101
TSC691E
3.8.5.2. Trap Addressing
The Trap Base Register (TBR) is made up of two fields, the Trap Base Address (TBA) and the trap type (tt). The TBA
contains the most-significant 20 address bits of the trap table, which is in external memory. The trap type field, which
was written by the trap, not only uniquely identifies the trap, it also serves as an offset into the trap table when the TBR
is written to the PC. The TBR address is the first address of the trap handler. However, because the trap addresses are
only separated by four words (the least-significant four bits of TBR are zero), the program must jump from the trap
table to the actual address of the particular trap handler.
Of the 256 trap types allowed by the 8-bit tt field, half are dedicated to hardware traps (0-127), and half are dedicated
to programmer-initiated traps (Ticc). For a Ticc instruction, the processor must calculate the tt value from the fields
given in the instruction, while the hardware traps can be set from a table such as the one below. See the Ticc instruction
definition for details.
The tt field remains valid until another trap occurs.
3.8.5.3. Trap Types and Priority
Each type of trap is assigned a priority (see Table 45 ). When multiple traps occur, the highest priority trap is taken,
and lower priority traps are ignored. In this situation, a lower priority trap must either persist or be repeated in order
to be recognized and taken.
Table 45. Trap Type and Priority Assignments
Trap
Priority
Trap Type (tt)
Synchronous or Asynchronous
1
-
Async.
Hardware error
2[1]
97-102
Sync.
Instruction Access
3[1]
1
Sync.
Illegal Instruction
4[1]
2
Sync.
Privileged Instruction
5[1]
3
Sync.
Floating–Point Disabled
6[1]
4
Sync.
Coprocessor Disabled
6[1]
36
Sync.
Window Overflow
7[1]
5
Sync.
Window Underflow
7
6
Sync.
Memory Address not Aligned
8
7
Sync.
Floating–Point Exception
9
8
Sync.
Coprocessor Exception
9
40
Sync.
Data Access Exception
10
9
Sync.
Tag Overflow
11
10
Sync.
Trap Instructions (Ticc)
12
128 - 255
Sync.
Reset
Note 1: the priority of those traps have changed in relation to the 90C601.
102
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Table 46. Trap Type and Priority Assignments (continued)
Trap
Priority
Trap Type (tt)
Synchronous or Asynchronous
Interrupt Level 15
13
31
Async.
Interrupt Level 14
14
30
Async.
Interrupt Level 13
15
29
Async.
Interrupt Level 12
16
28
Async.
Interrupt Level 11
17
27
Async.
Interrupt Level 10
18
26
Async.
Interrupt Level 9
19
25
Async.
Interrupt Level 8
20
24
Async.
Interrupt Level 7
21
23
Async.
Interrupt Level 6
22
22
Async.
Interrupt Level 5
23
21
Async.
Interrupt Level 4
24
20
Async.
Interrupt Level 3
25
19
Async.
Interrupt Level 2
26
18
Async.
Interrupt Level 1
27
17
Async.
3.8.5.4. Return From Trap
On returning from a trap with the RETT instruction, the following operations take place:
D The CWP is incremented by one (modulo the number of windows) to re-activate the previous window.
D The return address is calculated
D Trap conditions are checked. If traps have already been enabled (ET=1), an illegal instruction trap is taken. If traps
are still disabled but S=0, or the new CWP points to an invalid window, or the return address is not properly aligned,
then an error mode/reset trap is taken.
D If no traps are taken, then traps are re-enabled (ET=1).
D The PC is written with the contents of the nPC, and the nPC is written with the return address.
D The PS bit is copied back into the S bit.
The last two instructions of a trap handler should be a JMPL followed by a RETT. This instruction couple causes a
non-delayed control transfer back to the trapped instruction or to the instruction following the trapped instruction,
whichever is desired. See the RETT instruction definition for details.
3.9. Coprocessor Interface
In the SPARC architecture, the integer unit is the basic processing engine, but provision is made for two coprocessor
extensions. The extensions are in the form of instruction set extensions and a pair of identical signal interfaces. In the
TSC691E, one of these instruction and signal interface extensions is dedicated to floating-point operations and the
other is designated for a second coprocessor, either user defined or some future device offered by MATRA MHS and/or
Cypress. Although signals and instructions have been named to reflect the assumption of how these two extensions
will be used, either instruction set extension/signal interface may be used in any way desired.
In order for the TSC691E to support a user-defined coprocessor, the coprocessor should contain certain elements
defined by the SPARC architecture. These include an internal register set, a status register, a coprocessor queue, and
a set of compatible interface pins. These elements are identical to the floating–point interface, and it is recommended
MATRA MHS
Rev. H (02 Dec. 96)
103
TSC691E
that a user desiring to use the coprocessor interface thoroughly study the floating–point interface as an example of a
coprocessor interface application.
3.9.1. Protocol
The coprocessor extensions to the architecture are designed to allow the coprocessor to operate concurrently with the
integer unit and the floating–point unit. To keep operations synchronized, address and data busses are shared. The
initial TSC691E instruction decode determines which unit should execute the instruction. The TSC691E executes its
own instructions, but signals the coprocessor to continue the decode and execution if it recognizes a coprocessor
instruction. For coprocessor loads and stores, the TSC691E supplies the memory address and the coprocessor receives
or supplies the data. The coprocessor must deal with resource or data dependencies, signaling the problem to the
TSC691E by freezing the instruction pipeline with the CHOLD signal.
The signal interface between the TSC691E and the coprocessor consists of shared address, data, clock, reset, and
control signals, plus a special set of signals that provide synchronization and minimal status information between the
coprocessor and the TSC691E.
3.9.1.1. Coprocessor Interface Signals
The SPARC architecture defines two sets of signals intended for interfacing with two coprocessors. The TSC691E
assigns one set of coprocessor signals for specific use by the floating–point unit, and the other set of coprocessor signals
for a user–defined coprocessor. All floating–point interface signal names begin with an F, and all coprocessor interface
signal names begin with a C. Both sets of interface signals share the INST signal, which identifies a TSC691E
instruction fetch. The two groups of signals are symmetric, have identical timing requirements, and are listed in
Table 39 .
Instruction fetch is signaled by the TSC691E using the INST signal. The coprocessor uses INST as an input to enable
latching of an instruction on the data bus. The coprocessor latches all instructions fetched by the TSC691E, regardless
of instruction type. The TSC691E asserts CINS1 or CINS2 at the beginning of the decode stage of instruction execution
of a coprocessor instruction. The CINS1 or CINS2 signals are used to start the execution of a coprocessor instruction
and select which of the two most recently fetched instructions stored in the two–stage instruction buffer is to be
executed by the coprocessor.
The TSC691E requires the CP signal to be driven low in order for the integer unit to recognize the presence of a
coprocessor. Attempting to execute coprocessor instructions with CP high will cause the TSC691E to execute a cp
disabled trap.
Hardware interlocking for coprocessor instruction execution is provided with the CHOLD signal. This signal is
asserted by the coprocessor to freeze the TSC691E. This signal is asserted in cases where the TSC691E must be halted
to prevent it from causing a condition from which the coprocessor cannot recover. An example of this would be fetching
multiple coprocessor instructions that would otherwise overrun the coprocessor queue. The coprocessor would be
expected to assert CHOLD until it could handle additional instructions.
Coprocessor interrupts are asserted with the CEXC signal. This signal is asserted by the coprocessor upon the detection
of an exception case. The TSC691E will continue normal execution until the execution stage of the next coprocessor
instruction. At that time, the TSC691E will acknowledge the interrupt with CXACK, and begin coprocessor trap
execution.
Coprocessor branch on condition code (CBcc) instructions are executed by the TSC691E integer unit based on the
value of the CCC<1:0> signals supplied by the coprocessor. These signals are typically set by the execution of a
coprocessor compare instruction (defined by the designer). The CCCV signal supplied by the coprocessor indicates
whether the state of the CCC<1:0> signals is valid. CCCV is normally asserted, but is deasserted when a coprocessor
compare instruction is executed and remains deasserted until that instruction is completed. The deassertion of this
signal causes the TSC691E to halt execution. This interlock prevents the TSC691E from branching on invalid
condition codes. The SPARC architecture requires at least one non–coprocessor instruction between a coprocessor
compare and a coprocessor branch on condition code (CBcc) instruction.
104
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
32–Word by 32–Bit Register
File
32–Bit Status Register
Address Decode Register 1
Instruction Decode Register 1
Address Decode Register 2
Instruction Decode Register 2
Address Queue Register N
Instruction Queue Register N
Address Queue Register 1
Instruction Queue Register 1
Address Queue Register 0
Instruction Queue Register 0
Figure 66. Coprocessor Register Model
3.9.2. Register Model
The coprocessor register model specified by the SPARC architecture is shown in Figure 66 . The coprocessor has its
own 32 x 32-bit working register file from which all operands for CPop instructions originate and to which all results
return. The contents of these registers are transferred to and from memory under control of the TSC691E, using
coprocessor load/store instructions.
The Coprocessor State Register (CSR) contains the current status of the coprocessor. The exact nature of the exception
bits and trap types are implementation dependent. The CSR is read and written indirectly through memory using the
LDCSR and STCSR instructions.
The coprocessor queue is necessary to properly handle traps with concurrently operating units. The first-in, first-out
queue records all pending coprocessor instructions and their addresses at the time of a coprocessor exception. The front
entry of the queue contains the unfinished instruction that caused the exception. The rest of the queue contains
unfinished CPops which would be restarted or emulated after the trap handler returns control to the main program.
The address and instruction decode buffers hold instructions and their addresses until the TSC691E determines if they
belong to the coprocessor. If one of the held instructions belongs to the coprocessor, the TSC691E sends the appropriate
CINS signal to move the instruction into the coprocessor execute stage. The address and a copy of the instruction also
move into the queue at this point and remain there until the instruction completes.
When a trap is taken, the TSC691E asserts the FLUSH signal, causing the coprocessor to dump any instructions in the
decode buffers. FLUSH does not affect instructions which are already in the queue.
3.9.3. Exceptions
Exactly what conditions will generate a cp exception trap are implementation dependent. However, most
implementations would probably include Unfinished CPop as a condition that would cause an exception.
An Unfinished CPop trap is generated when the coprocessor cannot complete execution because the data has exceeded
the capabilities of the coprocessor and/or has generated an inappropriate result.
MATRA MHS
Rev. H (02 Dec. 96)
105
TSC691E
4. Fault Tolerant and Test Mechanism
Fault Tolerant Mechanism:
D Parity checking on 98.7% of the total number of latches with hardware error traps
D Parity checking of address, data pads and control pads
D Program Flow Control
D Master/Checker operation
D Interleaving of the register file bits for better detection of SEU
D Manufactured using TEMIC Space hardened 0.8 µm SCMOS RT TECHNOLOGY
Test Mechanism:
D IEEE Standard Test Access Port & Boundary-Scan Architecture
D Internal Scan Path to test the internal parity error detection during off-line test
D Possibility to halt the IU by an external signal
Destination
ERRTYP
PARITY
Register File
Control Error
136 x 32bits
Source 1
Source 2
Ch
Ch
ERROR
Ch
Program
Flow
Control
PC
G
MCERR
Arithmetic
and Logic
Unit
Program
Counters
Shift Unit
G
Align
Master
Checker
Control
Processor State
Window Invalid
Trap Base
Multiply Step
G
Align
Instruction
Decode
G
G
G
Boundary Scan Path
control
CMODE
Ch
G
106
CPAR
Address
APAR
TAP
Instruction/ Data
DPAR
TAP control
Parity Checkers
Parity Generators
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
4.1. Fault Tolerant and Test Support signals
Some signals have been added for fault tolerant and test mechanism improvement. These new signals can be classified
as follows:
Address Parity Generation:
APAR—Address Bus Parity (output)
ASPAR—ASI and SIZE Parity (output)
Data Parity Generation/Checking:
DPAR—Data Bus Parity (bidirectional)
MEC control signal Parity Generation:
IMPAR—IU to MEC Control Parity (output)
FPU control signal Parity Generation/Checking:
IFPAR—IU to FPU Control Parity (output)
FIPAR—FPU to IU Control Parity (input)
Parity Checking Error Output
HWERROR—Hardware Error Occurs (outputs)
Odd parity definition: The number of one in a word, including the parity bit, is alway odd.
(e.g. 00000000 --> P=1, 00000001 --> P=0)
Master/Checker Mode
CMODE—checker Mode (input)
MCERR—Comparison Error (output)
Test Access Port
TCLK—Test Clock (input)
TRST—TEST Reset (input)
TMS—Test Mode Select (input)
TDI—Test Data Input (input)
TDO—Test Data Output
Miscellaneous
601MODE—Normal 601Mode Operation (input)
HALT—Halt (input)
FLOW—enable or disable Program Flow Control
A more detailed description of these signals is provided in Chapter 3.5
MATRA MHS
Rev. H (02 Dec. 96)
107
TSC691E
4.2. Program Flow Control
4.2.1. Introduction
A very high proportion of transient faults can cause errors in the program flow (75% in a traditional microprocessor).
This type of error is detected by the MHS TSC691E using Embedded Signature-Monitoring (ESM) techniques.
A program using ESM is partitioned in branch free basic blocks and branch instructions. For each executed instruction,
the IU calculates a checksum of 32 bits of the operation code during the execution. The checksum result consist of the
logic XOR of the instruction words with the previous checksum. The 16 MSBs are XORed with the 16 LSBs to provide
a signature word.
This 16 bits signature is compared with the correct value, precomputed by the compiler, whenever a SETHI instruction
(SETHI g0,%PRE_CHECKSUM) is executed. After the comparison, the checksum is reseted to zero.
The 6 MBSs in the immediate value of the SETHI instruction must be set to «011111».
In case of a comparison error, a hardware trap is taken with Trap Type=66H and HWERROR asserted.
There are three cases when the subsequent check is disabled:
1. When a trap is taken.
2. When executing a RETT instruction.
3. When executing a SETHI instruction to R[0] with the immediate value set to zero. This SETHI instruction
does not perform a comparison but zero the checksum. It is reserved as a NOP instruction.
For these cases the subsequent check is disabled, and will not signal an error, but will enable the checking again with
checksum equal to zero.
The Program Flow Control is enabled by the FLOW signal input. After reset the Program Flow Control is enabled (if
FLOW signal is low), and the checksum is reseted to zero.
4.2.2. Example of Program Flow Control
SETHI(g0,%CH7)
SETHI(g0,%CH4)
SETHI(g0,%CH3)
FLOW
6
Pgm start
(add=0)
1
2
3
12
SETHI(g0,%CH6)
SETHI(g0,%CH1)
SETHI(g0,%0)
7
5
4
TRAP
SETHI(g0,%CH2)
SETHI(g0,%CH8)
8
RETT
9
10
SETHI(g0,%CH5)
14
13 JMPL,
RESTORE
CALL,
SETHI(g0,%CH7)
11
1- Program starts at address=0x0 with Program Flow Control enabled and Checksum=0.
2- No comparison performed, next checking disabled and Checksum is reseted to zero. (NOP)
3- No comparison performed, next checking enabled and Checksum is reseted to zero.
4- Comparison performed, next checking enabled and Checksum is reseted to zeroomparison.
5- TRAP instruction disables the next checking.
6- No comparison performed, next checking enabled and Checksum is reseted to zero.
7- Comparison performed, next checking enabled and Checksum is reseted to zero.
8- RETT instruction disables the next checking.
9- No comparison performed, next checking enabled and Checksum is reseted to zero.
10- Comparison performed, next checking enabled and Checksum is reseted to zero.
108
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
11- When a CALL instruction is encountered, the delay instruction must be a SETHI instruction to perform a
comparison, enable the next checking and reset the Checksum.
12- Comparison performed, next checking enabled and Checksum is reseted to zero.
13- When the JMPL instruction is encountered the Program Flow Control is not disabled and next checking is
enable since the delay instruction is a RESTORE.
14- Comparison performed (checksum is calculated from the last SETHI encountered in the subroutine).
Conclusion: In this example, the sequences 3 to 4, 6 to 7 and 9 to 14 are checked.
Programming Note:
1- When returning from a CALL routine (13), the delay instruction is a RESTORE so, when encountering the
next SETHI(g0,%CHS) (14), the comparison is performed with a checksum calculated from the last
SETHI(g0,%CHS) of the subroutine (12).
2- All the delay instruction (instruction after a control transfer instruction: Bicc, FBfcc, CBccc, CALL, JMPL,
Ticc or RETT) are added in the checksum even this instruction is annuled.
4.3. Parity Checking
4.3.1. Introduction
In the TSC691E, 98.7% of all registers are protected by a odd parity bit (100% of the register file is protected). The
checking of registers and busses is be performed only if the registers or the busses are used by the current instruction.
With this approach, unused registers/busses will not cause an error and decreasing the uptime of the system will be
limited.
Address bus, Size and ASI busses, Data bus, Control signals of the MEC and of the FPU are also protected with parity
bits.Control signals for coprocessor are not protected by parity bit. The parity checking is disabled during reset. Care
has to be taken not to read a register before it has been written and its parity bits initialized.
When an error occurs, the HWERROR signal is asserted low and a trap is taken depending of the parity error type
(see Table 47 , page 116).
Definition of odd parity bit:
The number of one in a word, including the parity bit, is alway odd.
(e.g. 00000000 --> P=1, 00000001 --> P=0)
4.3.2. Trap handling
When a hardware error is detected the HWERROR signal is asserted then a trap routine is taken depending of the error
type (see Table 47 ). The HWERROR signal is asserted until the error trap is taken.This software routine reviews the
failing instruction. If the cause of the error was a transient fault, it may be removed by just resuming this instruction.
In this case, HWERROR is deasserted (see 5.2.2.2, page 127).
If the error was caused by a non removable error, another hardware error trap is generated. Because a synchronous trap
is taken during a time when traps are disabled, the IU enters the error mode, asserts ERROR signal and halts
(HWERROR will stay asserted until removed by reset).
This means that the error detection mechanism will detect the error when the failing instruction is in the execute stage
in order to handle the trap normally, i.e. correct PC for the failing instruction.
The trap are grouped into the following Error-Type:
- Restartable, precise error: Errors that can be removed by retrying the instruction and with correctly saved PC
and nPC. These errors can be removed by simply returning from the trap routine.
- Non-restartable, precise error: Errors that will remain even after an instruction retry, but with correctly saved
PC and nPC. These errors are not removable and the trap routine should not attempt a retry. Since the address
of failing instruction is know, the kernel can attempt a local clean-up, i.e. not having to restart the application.
- Restartable, late error: Errors that can be removed by retrying the instruction but with PC and nPC pointing to
the following instruction (was data load error). The trap routine can emulate the failing instruction or retry
after the PC and nPC have been adjusted.
MATRA MHS
Rev. H (02 Dec. 96)
109
TSC691E
- Non-restartable, imprecise error: Error that can not be associated with a particular instruction and cannot be
removed by instruction retry. These errors are typically quite severe and will require a re-boot.
- Register file error: Error that occurred in the register file (special case of Non-restartable, precise error)
- Program flow error: Error detected by the program flow control.
Table 47. Error Type Assignments
Trap Type
Error Type
Error Signal
61H
Restartable, precise error
HWERROR
62H
Non-restartable, precise error
HWERROR
63H
Restartable, late error
HWERROR
64H
Non-restartable, imprecise error
HWERROR
65H
Register file error
HWERROR
66H
Program flow error
Trap only
-
Master / Checker error
MCERR
-
Error mode
ERROR
4.3.3. Priority within hardware traps for IU
When multiple hardware traps occur, the highest priority trap is taken, and lower priority traps are ignored. The priority
applied on the harware traps of the IU are define as follow:
Table 48. Hardware Priority
Trap Type
Error Type
Error Signal
61H
Restartable, precise error
5
62H
Non-restartable, precise error
2
63H
Restartable, late error
4
64H
Non-restartable, imprecise error
1
65H
Register file error
3
66H
Program flow error
6
IU synchronous traps
7
-
Remark: Priority 1 is for highest priority and 5 for the lowest priority. All other synchronous traps (caused by the
actions of an instruction) has a lower priority.
4.3.4. Parity Checking on Register File and Control/Status Registers
The register file and the control/status registers of the TSC691E are protected by a parity bit. Hardware error on those
registers shall lead to hardware error trap as defined in .
110
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Table 49. Hardware error type for user registers
Register
Register File
Error type
Trap type
Register file error
65H
FPC
Restartable, precise error
61H
DPC
Non-restartable, precise error
62H
EPC/WPC
Non-restartable, imprecise error
64H
PSR
Non-restartable, imprecise error
64H
WIM
Non-restartable, precise error
62H
TBR
Non-restartable, precise error
62H
Restartable, precise error
61H
Y
4.3.5. Parity Checking on Control Signal for the FPU
The control signals between the IU and the FPU are protected by a parity bit.
4.3.5.1. Output control signals
The control bus contains five bits: FINS1, FINS2, FLUSH, FXACK, INST. The parity output for these five signals is
IFPAR (IU to FPU PARity). This parity bit is generated by the IU.
IFPAR is a three-state (on chip pull_up resistor=20kΩ) output controlled by TOE signal.
4.3.5.2. Input control signals
The input control signals are: FCC<1:0>, FCCV, FEXC, FHOLD,FP. The parity input for these signals is FIPAR (FPU
to IU PARity). This parity bit is generated by the FPU and checked by the IU when a FBfcc instruction is executed.
FCCV and FHOLD are re-synchronized on the rising edge of the clock to check the parity.
4.3.6. Parity Checking on Control Pads for the TSC693E (MEC)
The 13 control signals between the IU and the MEC are protected by a parity bit.
4.3.6.1. Output control signals
The output control bus contains six bits: DXFER, LDSTO, LOCK, RD, WE, WRT. The parity output for these five
signals is IMPAR (IU to MEC PARity). This parity bit is generated by the IU.
IMPAR is a high_Z (on chip pull_up resistor=20kΩ) output controlled by the COE or TOE signal.
4.3.6.2. Input control signals
No parity is performed on the input control signals: MAO, MDS, MEXC, MHOLDA, MHOLDB, BHOLD.
4.3.7. Parity Checking on Control Pads for the Coprocessor
No parity is performed on the input and output control signals.
4.3.8. Parity Generation on ADDRESS Bus
The 32 bit address bus contains a parity bit calculated by the IU and sent out on the APAR pad.
The ASI<7:0> and SIZE<1:0> busses contain also a parity bit called ASPAR which is calculated by the IU.
APAR and ASPAR are three-state (on chip pull_up resistor=20kΩ) outputs controlled by AOE or TOE signal.
4.3.9. Parity Checking on DATA Bus
The DPAR bidirectional signal contains the odd parity over the 32-bit data bus.
MATRA MHS
Rev. H (02 Dec. 96)
111
TSC691E
When the IU receives a data (LOAD) or an instruction, the parity bit is checked by the IU. In case of a STORE data
instruction, the parity bit is generated and launched in parallel by the IU.
4.3.10. Non RT 601 Mode
To be able to use a standard FPU (i.e. TSC692E), parity on the data bus has to be generated internally and parity
checking on the control bus must be turned off.
This feature is controlled by asserting the 601MODE input signal. This signal is static and shall not change when
running.
4.3.11. Error Type for external signals parity errors
Data inputs (Ints and Load) and FPU to IU control signals receive a parity bit which is checked by the IU. If an error
is detected, the IU takes a trap depending of the error type Table 50 .
Table 50. Hardware error type for external signals
Register
Error type
Trap type
Data (inst)
Restartable, precise error
61H
Data (load)
Restartable, late error
63H
Floating–Point Disabled [1]
04H
FIPAR
Note 1: The parity is only checked when a FBfcc instruction is executed.
4.4. Master/checker operation
The MHS TSC691E includes comparator circuits at the outputs to support fault detection. Applications requiring a
high level of reliability can use this Master/Checker operation to introduce fault detection on a system level. By
duplication of units without the use of external comparators, 100% of the internal errors can be detected, especially
those errors which are not detected by the internal unit concurrent error detection mechanism.
4.4.1. Basic function
By asserting the signal CMODE the TSC691E can be configured either as master or checker. This signal is static and
shall not change when running. Assertion of this signal will set the IU to act as a checker to support master/checker
operation. All output signals except ERROR,HWERROR, MCERR and TAP signals will be high-Z (on chip pull_up
resistor=20kΩ). The master and at least one checker circuit are working in parallel and execute the same program.
When the master is forcing the address and data bus, the checker is in a read and compare mode. This means the output
buffers are disabled and the external busses are compared by the checker with its internal results. If a mismatch occurs
on any output, then the MCERR signals are asserted until the mismatch disappears. In this case, the system hardware
and/or software can take appropriate action.
If the master IU signals an internal error before a comparison error is indicated, it is possible to stop execution of the
two IUs by asserting the HALT signal, disable the master IU, change the checker IU to master IU and continue
execution. CMODE signal can be changed when RESET signal is asserted or when the IU is in halt mode.
On a master processor, the three-state control signals (e.g : AOE, COE, DOE, TOE) disable the checker mode of the
three-stated buffers.
An external/internal mismatch can occur for two reasons:
1- In a system with only one master processor, a short or other electrical failure can force the output signal to a
fixed voltage. For example, a bus signal can be shorted to ground. When the circuit drives a high voltage on
the bus, the external signal will be pulled low and a mismatch will occur and he IU asserts the
CMPERR signals.
2- An external/internal mismatch can occur in the master/checker mode. Figure 67 shows a basic master/checker
configuration using two TSC691E devices.
112
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Using the master/checker solution there is a possibility that the system can continue with only the correct
remaining unit, or with both after the restoration of state of the faulty unit. If an internal error is indicated in
the checker, it could be ignored. The MEC requires error signals from both the master and the checker. In case
of corruption the system behavior is defined by the MEC.
Control
Address
Data
HALT
HALT
MASTER IU
ERROR
HWERROR
CHECKER IU
ERROR
HWERROR
CMODE = 1
CMODE = 0
TAP
TAP
MCERR
MCERR
Figure 67. Master/Checker configuration
4.4.1.1. Master/Checker Signal description
4.4.1.1.1. MCERR—Comparison Error (output)
This signal is asserted in the checker mode when a comparison error occurs on the internal output signals (except
ERROR, HWERROR, MCERR and TAP signals) vis-à-vis the output signal of the master IU. It is deasserted when
the error disappears.
This output is high-Z (on chip pull_up resistor=20kΩ) when the TOE signal is deasserted.
4.4.1.1.2.CMODE—checker Mode (input)
Assertion of this signal will set the IU to act as a checker to support master/checker operation. All output signals except
ERROR, HWERROR, and TAP signals will be high-Z (on chip pull_up resistor=20kΩ). It is a static signal and shall
not change when running. It can change only during reset cycle or halt mode.
4.5. IEEE Standard Test Access Port & Boundary-Scan Architecture
The IU includes a Boundary Scan using a Test Access Port (TAP) interface [IEEE standard 1149.1]. This interface
is used for debugging and test purposes.
This interface provides standardized approaches to :
D testing the interconnections between integrated circuits once they have been assembled on a printed circuit board
or other substrate.
D support of testing the integrated circuit itself.
D observing or modifying activity during the component’s normal operation.
4.5.1. TAP
The Test Access Port includes the following connections : TCLK, TMS, TRST, TDI and TDO. Dedicated TAP
connections are required to allow access to the full range of mandatory features of this standard.
MATRA MHS
Rev. H (02 Dec. 96)
113
TSC691E
4.5.1.1. TCLK (input)
The Test Clock Input provides the clock for the test logic defined by this standard. TCK is active high. The IEEE
standards requires that TCLK can be stopped at 0 indefinitely without causing any change to the state of the test logic.
When TCLK is active, CKL must be held to one.
4.5.1.2. TMS (input)
The signal received by TMS is decoded by the TAP controller to control test operation.
TMS is sampled on the rising edge of TCLK and has to change on the falling edge of TCLK.
4.5.1.3. TDI (input)
Serial test instructions and data are received by the test logic by TDI.
TDI is sampled on the rising edge of TCLK and has to change on the falling edge of TCLK.
4.5.1.4. TRST (input)
The TRST input provides for asynchronous initialization of the TAP controller.
4.5.1.5. TDO (output)
TDO is the serial output for test instructions and data from the test logic defined in the standard.
4.5.2. TAP Controller
The TAP controller is a synchronous finite state machine that responds to changes at the TMS and TCLK signal of the
TAP and controls the sequence of operations of the circuit defined by the IEEE standard.
4.5.3. The Instruction Register
The Instruction Register allows an instruction to be shifted into the design. The instruction is used to select the test
to be performed or the test data register to be accessed or both. A number of mandatory and optional instructions are
defined by the standard. The instructions SAMPLE/PRELOAD, INTEST, EXTEST and BYPASS are implemented on
this chip.
The private instruction TESTPAR will be implemented to access the internal scan path registers. These registers are
not publicly accessible and will be used to test the internal parity logic.
4.5.3.1. Design and Construction of the instruction register
The instruction register is a shift-based design having an optional parallel input. These parallel inputs permit capture
of design-specific information in the Capture-IR state. Figure 68 illustrates an example implementation of an
Instruction Register Cell.
Shift IR
G1
Data
From last cell
1
1
1D
C1
1D
C1
Instruction
bit
R
To next cell
Clock IR
Update IR
Reset
Figure 68. Instruction Register Cell
114
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
4.5.3.2. BYPASS Instruction
The BYPASS register contains a single shift register stage, used to speed-up shifting at the board level, through
components which are not activated.
4.5.3.3. EXTEST Instruction
The EXTEST instruction shall connect the BOUNDARY SCAN register between TDI and TDO. It is used to test
connections between components on the board level. All output signals can be disabled by using the EXTEST
instruction (except TAP).
4.5.3.4. INTEST Instruction
Intest instruction allows testing of the on-chip system logic while the component is assembled on the board, with each
test pattern and response being shifted through the boundary-scan register.
4.5.3.5. SAMPLE/PRELOAD Instruction
The SAMPLE instruction allows normal operation if the system logic with the ability to sample signals entering and
leaving the component without affecting circuit operation.
PRELOAD allows a value to be preloaded on the latched outputs of the boundary scan register. This instruction does
not modify the system behavior.
4.5.4. The Device Identification Register
The Device Identification Register is implemented on the chip. It contains the TSC691E’s assigned component
identifier: 0x0B6400B1. It is selected by the IDCODE instruction.
4.5.5. Internal Scan Path
An Internal Scan Path will be implemented to provide the off-line test of the internal parity error detection. This Internal
Scan Path will be controlled by the TAP and will force some nodes in the generation circuit of the parity bits. This would
then result in a value with the wrong parity. When this value is read again an error will be detected if the error detection
works correctly. This chain would have one bit for each parity generator.
4.5.6. Boundary scan test register
The Boundary-scan technique involves the inclusion of a shift register stage (contained in a Boundary-scan cell)
adjacent to each component pin so that signals at component boundaries can be controlled and observed using scan
testing principles.
Figure 68 illustrates an example implementation for a Boundary-scan cell that could be used for an input or output
connection to an integrated circuit. Dependent on the control signals applied to the multiplexers, data can either be
loaded into the scan register from the Signal-in port (e.g., the input pin), or driven from the register through the
Signal-out port of the cell (e.g., into the core of the component design). The second flip-flop (controlled by clock B)
is provided to ensure that the signals driven out of the cell in the latter case are held while new data is shifted into the
cell using clock A.
MATRA MHS
Rev. H (02 Dec. 96)
115
TSC691E
Scan out
G1
Mode
Signal in
1
1
Shift/Load
Signal
out
G1
1
1
1D
1D
C1
Scan in
C1
Clock A
Clock B
Figure 69. Boundary Scan Cell
4.6.Interleaving register file bits
It is known that the impact from an SEU will flip adjacent bits in a register file. These multiple bit errors might be
impossible to detect with one parity bit error. Though these cases with multiple bit errors due to SEU are probably more
rare than one bit errors, they cannot be neglected, especially in the register file, which corresponds to 70% of the entire
amount of registers in the IU.
One solution to this problem is to interleave the bits of one word with the bits of another word. This is done in the register
file and will remove all multiple bit errors due to SEU and full error detection is possible with a single parity bit checker.
5. Electrical and Mechanical Specification
5.1. Maximum rating and DC Characteristics
5.1.1. Maximum Ratings
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ambient Temperature with Power Applied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply Voltage[1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-65 ° C to +150 ° C
-55 ° C to +125 ° C
-0.5 V to +7.0 V
-0.5 V to +7.0 V
5.1.2. Operating Range
116
Range
Ambient Temperature [2]
Vcc
Military
-55° C to 125° C
5V +/- 10%
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
5.1.3. DC Characteristics Over the Operating Range
Parameters
Description
Test Conditions
Min.
VOH
Output HIGH Voltage
VCC = Min., IOH = -2.0 mA
2.4
VOL
Output LOW Voltage
Vcc = Min., IOL = 4.0 mA
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IIZ
Input Leakage Current
IOZH
VCC = Max., VSS < VIN < VCC
Output Leakage Current
IOZL
Max.
Units
V
0.5
V
2.1
VCC
V
-0.5
0.8
V
-10
10
µA
µA
VCC = Max., Vout = VCC
-10
10
VCC = Max., Vout = VSS
50[3]
240[3]
ISC
Output Short Circuit Current
VCC = Max., Vout = 0V
-30
-350
mA
ICCop
Supply Current
VCC = Max., f = 14 MHz
-
200
mA
ICCsb
Stand By Current
Vcc = Max, f=0Mhz
-
1
mA
Notes :
1. All power and ground pins must be connected before power is applied.
2. Ambient temperature is defined as the ‘instant on’ case temperature.
3. on chip pull_up resistor=20kΩ
5.1.4. Capacitance Ratings [4, 5]
TSC691E
Parameters
Description
Max. (pF)
CIN
Input Capacitance
10
COUT
Output Capacitance
12
CIO
Input/Output Bus Capacitance
15
5.1.5. AC Test Loads and Waveforms
R1
470 W
5V
3V
90%
90%
10%
10%
0V
OUTPUT
C=50pF
(6)
R2 319 Ω
TEST LOAD
< 3 ns
< 3 ns
WAVEFORM
Notes :
4. Tested initially and after any design or process changes that may affect these parameters.
5. Test conditions are: VCC=5.0V, TA=25° C, f=1MHz
6. C = 30 pF (for FINS <1:∅> signal)
MATRA MHS
Rev. H (02 Dec. 96)
117
TSC691E
5.2. TSC691E AC Characteristics
5.2.1. AC Characteristics Over the Operation Range [1]
Parameter
Description
Reference
Edge
TSC691E–14
Min Max
Unit
1
tCY
Clock cycle
71
ns
2
tCHL
Clock high and low
33
ns
3
tCRF
Clock rise and fall
1
V/ns
4
tAD
Address/Control [2] output delay
CLK+
5
tAH
Address/Control [2] output valid
CLK+
6
tDOD
D<31:0> output delay
CLK-
7
tDOH
D<31:0> output valid
CLK-
4
ns
8
tDIS
D<31:0> input setup
CLK+
7
ns
9
tDIH
D<31:0> input hold
CLK+
9
ns
10
tMES
MEXC input setup
CLK+
12
ns
11
tMEH
MEXC input hold
CLK+
4
ns
12
tHS
MHOLDA, B input setup
CLK-
4
ns
13
tHH
MHOLDA, B input hold
CLK-
9
ns
12
tHS
YHOLD [3] input setup
CLK-
10
ns
CLK-
7
ns
[3]
7
ns
ns
35
ns
13
tHH
YHOLD
14
tHOD
XHOLD [3] to Address/Control output delay
XHOLD-
15
tHOH
XHOLD [3] to Address/Control output valid
XHOLD+
16
tOE
AOE, COE, DOE to output enable delay
XOE-
27
ns
17
tOD
AOE, COE, DOE to output disable delay
XOE+
27
ns
18
tTOE
TOE asserted to output enable delay
TOE-
38
ns
19
tTOD
TOE deasserted to output disable delay
TOE+
38
ns
20
tSSD
INST, FXACK, CXACK, INTACK,ERROR output delay
CLK+
36
ns
21
tSSH
INST, FXACK, CXACK, INTACK, ERROR output valid
CLK+
3
ns
22
tRS
RESET input setup
CLK+
27
ns
23
tRH
RESET input hold
CLK+
3
ns
24
tFD
FINS<1:0> output delay
CLK+
25
tFH
FINS<1:0> output valid
CLK+
24
tFD
CINS<1:0> output delay
CLK+
25
tFH
CINS<1:0> output valid
CLK+
3.5
ns
26
tFIS
FCC<1:0>, CCC<1:0> input setup
CLK+
18
ns
27
tFIH
FCC<1:0>, CCC<1:0> input hold
CLK+
4
ns
28
tDXD
DXFER output delay
CLK+
29
tDXH
DXFER output valid
CLK+
118
input hold
55
40
0
ns
30
3.5
ns
ns
40
51
2
ns
ns
ns
ns
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Parameter
Description
[3]
TSC691E–14
Min Max
XHOLD-
36
Unit
30
tHDXD
XHOLD
31
tHDXH
XHOLD [3] deasserted to DXFER output valid
XHOLD+
32
tNUD
INULL output delay
CLK+
33
tNUH
INULL output valid
CLK+
3
ns
34
tMDS
MDS input setup
CLK-
4
ns
35
tMDH
MDS input hold
CLK-
5
ns
36
tFLS
FLUSH output delay
CLK+
37
tFLH
FLUSH output valid
CLK+
3
ns
38
tCCVS
FCCV, CCCV input setup
CLK-
13
ns
39
tCCVH
FCCV, CCCV input hold
CLK-
5
ns
40
tXES
FEXC, CEXC input setup
CLK+
18
ns
41
tXEH
FEXC, CEXC input hold
CLK+
4
ns
42
tMAD
MAO Asserted to Address/Control Output Delay
MAO+
43
tMAH
MAO Deasserted to Address/Control Output Valid
MAO-
44
tERD
HWERROR output delay
CLK+
45
tERH
HWERROR output valid
CLK+
5
ns
46
tTMS
TMS input setup
TCLK+
20
ns
47
tTMH
TMS input hold
TCLK+
25
ns
48
tTDIS
TDI input setup
TCLK+
20
ns
49
tTDIH
TDI input hold
TCLK+
25
ns
50
tTRS
TRST input setup
TCLK+
20
ns
51
tTRH
TRST input hold
TCLK+
25
ns
52
tTDOD
TDO output delay
TCLK-
53
tTDOH
TDO output valid
TCLK-
54
tTCY
TCLK clock cycle
55
tXAPD
XAPAR[4] output delay
CLK+
56
tXAPH
XAPAR[4] output valid
CLK+
57
tDPOD
DPAR output delay
CLK-
58
tDPOH
DPAR output valid
CLK-
4
ns
59
tDPIS
DPAR input setup
CLK+
6
ns
60
tDPIH
DPAR input hold
CLK+
4
ns
61
tIFPD
IFPAR output delay
CLK+
62
tIFPH
IFPAR output valid
CLK+
3
ns
63
tFIPS
FIPAR input setup
CLK+
18
ns
64
tFIPH
FIPAR input hold
CLK+
4
ns
MATRA MHS
Rev. H (02 Dec. 96)
asserted to DXFER output delay
Reference
Edge
0
ns
36
30
36
2
ns
ns
ns
ns
45
45
5
100
ns
ns
ns
ns
1000
ns
55
ns
7
ns
45
53
ns
ns
119
TSC691E
Parameter
Reference
Edge
Description
TSC691E–14
Min Max
60
Unit
65
tIMPD
IMPAR output delay
CLK+
66
tIMPH
IMPAR output valid
CLK+
67
tMCED
MCERR output delay [5]
CLK+
68
tMCEV
MCERR output
valid [5]
CLK+
5
ns
69
tSTATS
601MODE/FLOW/CMODE/FP input setup [6]
CLK+
18
ns
70
tHAS
HALT input setup
CLK-
13
ns
71
tHAH
HALT input hold
CLK-
4
ns
72
tIRLS
IRL<3:0> input setup
CLK+
2
ns
73
tIRLH
IRL<3:0> input hold
CLK+
6
ns
7
ns
ns
45
ns
NOTES:
1. Test conditions assume signal transition times of 3 ns or less, a timing reference level of 1.5V, input levels of 0 to 3.0V and output loading of
50pF
2. Address/Control signals include: A<31:0>, ASI<7:0>, SIZE<1:0>, RD, WRT, WE, LOCK, and LDSTO.
3. YHOLD includes BHOLD, FHOLD, and CHOLD.
4. XAPAR includes APAR and ASPAR.
5. When an error occurs on D[31:0] or Dpar, MCERR may be delayed for 1 cycles depending of frequency.
6. 601MODE/FLOW/CMODE/FP shall be change to be related to positive clock edge during reset active or HALT active.
7. XHOLD includes BHOLD, MHOLDA, MHOLDB, FHOLD and CHOLD.
5.2.2. Waveforms
5.2.2.1. Clock and ERROR / RESET Timing
1
3
2
DV/Dt =0.8 V/ ns
CLK
ERROR
20
21
23
RESET
22
9 CLK Cycles
Minimum
FP
601MODE
FLOW
CMODE
69
Reset needs to be synchronized with
CLK only if the processor must be in
step with other devices in the system.
120
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
5.2.2.2. Clock and HWERROR Timing for Parity Error Type
CLK
45
HWERROR
44
44
A[31:0]
A0
A1
A2
D[31:0]
D0
D1
D2
Trap 1.
---
Trap 2
D3
Parity error
on this data
INULL/FLUSH
INST
Note: The IU check the parity on internal register when the instruction is in the execute stag.
5.2.2.3. TOE De–assertion /Assertion
CLK
All bussed
outputs
Hi - Z
All active
HIGH outputs
Hi - Z
All active
LOW outputs
Hi - Z
19
18
TOE
MATRA MHS
Rev. H (02 Dec. 96)
121
TSC691E
5.2.2.4. Load Timing
1
CLK
5
4
A<31:0>
ASI<7:0>
SIZE<1:0>
LD INST
ADR
LD
DATA
ADR.
A1
A2
A3
ASIA0
ASIA1
ASIA2
ASIAD
ASIA3
SIZEA0
SIZEA1
SIZEA2
SIZEAD
SIZEA3
RD
8
9
D<31:0>
LD
I1
I2
28
D1
29
DXFER
20
21
INST
122
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
5.2.2.5. Store Timing
1
CLK
4
A<31:0>
ST
INST
ADR
ASI<7:0> ASI
A0
SIZE<1:0>
SIZEA0
5
A1
A2
DATA
ADR.
DATA
ADR.
A3
ASIA1
ASIA2
ASIAD
ASIAD
ASIA3
SIZEA1
SIZEA2
SIZEAD
SIZEAD
SIZEA3
WE
WRT
8
D<31:0>
ST
7
6
9
INST 1
28
INST 2
I3
DATA
29
DXFER
21
20
INST
33
32
INULL
57
DPAR
MATRA MHS
Rev. H (02 Dec. 96)
58
DATA PARITY
123
TSC691E
5.2.2.6. Load with Cache Miss
1
CLK
4
A<31:0>
ASI<7:0>
SIZE<1:0>
LD DATA
ADR.
5
A1
LD DATA
ADR.
A1
A1
A2
ASIA0
ASIA1
ASIA1
ASIAD
ASIA1
ASIA2
SIZEA0
SIZEA1
SIZEA1
SIZEAD
SIZEA1
SIZEA2
8
D<31:0>
Missed
Data
LD Data
17
9
16
DOE
14
15
13
12
MHOLD
34
35
MDS
30
31
DXFER
60
16
DPAR
LD Data Parity
42
43
MAO
124
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
5.2.2.7. Memory Exception Timing
1
CLK
4
5
A<31:0>
ASI<7:0>
A1
A2
ASIA1
ASIA2
SIZEA2
SIZE<1:0> SIZEA1
A3
A TB
ASIA2
ASIA3
ASITB
SIZEA2
SIZEA3
SIZEA4
A2
33
32
INULL
12
13
MHOLD
34
35
MDS
11
10
MEXC
5.2.2.8. Bus Arbitration Timing
CLK
A<31:0>
ASI<31:0>
SIZE<1:0>
A1
A1
A1
A2
Hi - Z
WE
RD
Hi - Z
LOCK
LDSTO
14
15
12
BHOLD
AOE,
COE,
DOE
13
17
16
TOE can replace the combined function of AOE, COE, and DOE
MATRA MHS
Rev. H (02 Dec. 96)
125
TSC691E
5.2.2.9. Floating-Point Timing
CLK
A<31:0>
A1
A2
A3
A4
A5
A6
A7
D<31:0>
FPop
Inst 1
Inst 2
Inst 3
FCMP
Inst 5
Inst 6
A8
Inst 7
INST
24
25
FINS1/2
26
27
FCC<1:0>
38
39
36
37
FLUSH
40
41
FEXC
20
21
FXACK
5.2.2.10. TAP Signals
54
TCLK
47
TMS
46
49
48
TDI
52
53
TDO
51
TRST
50
CLK=1
126
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
5.2.2.11. PARITY Signals
1
2
CLK
5
4
A[31:0]
A0
A1
A2
A3
A4
APAR A3
APAR A4
A4
56
55
APAR A1
APAR
APAR A2
APAR A4
9
8
D[31:0]
FP inst
FP inst
60
59
DPAR
DPAR inst
DPAR inst
64
63
FIPAR
62
61
IFPAR
66
65
IMPAR
5.2.2.12. MASTER/CHECKER Signals
1
2
CLK
67
68
MCERR
error
MATRA MHS
Rev. H (02 Dec. 96)
error
127
TSC691E
5.2.2.13. IRL[3:0] Signals
CLK
73
72
IRL[3:0]
5.2.2.14. HALT Signal timing
1
2
CLK
INTERNAL
CLK
ADD
A1
A2
A3
A3
A4
OUTPUT
SIGNALS
D0
D1
D2
D2
D3
70
HALT
70
71
71
FP
601MODE
FLOW
CMODE
128
69
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
5.3. Package Description
5.3.1. 256-Pin MQFP_F Package
MATRA MHS
Rev. H (02 Dec. 96)
129
TSC691E
5.3.2. 256-Pin MQFP_F Pin Assignments
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
1
IMPAR
65
VSSO
129
VCCI
193
VSSO
2
VCCO
66
VSSO
130
VCCO
194
VSSO
3
COE
67
VSSI
131
D11
195
IFT
4
VCCI
68
VCCO
132
VCCO
196
VSSI
5
DXFER
69
A16
133
D12
197
FLUSH
6
LOCK
70
A15
134
D10
198
IFPAR
7
VSSO
71
A18
135
VSSO
199
VCCO
8
WRT
72
A17
136
D13
200
ERROR
9
SIZE1
73
A19
137
D15
201
CXACK
10
MAO
74
VSSO
138
D14
202
INTACK
11
ASPAR
75
A20
139
D16
203
FXACK
12
SIZE0
76
VCCI
140
VSSI
204
VSSO
13
VCCO
77
VSSI
141
D17
205
CCC1
14
HWERROR
78
A21
142
VCCO
206
CCC0
15
ASI1
79
VCCO
143
D18
207
FPSYN
16
ASI0
80
A22
144
D19
208
FCC1
17
VSSI
81
A24
145
-NC-
209
VSSI
18
ASI2
82
A23
146
-NC-
210
FCC0
19
ASI3
83
A25
147
-NC-
211
IRL3
20
VSSO
84
A26
148
-NC-
212
IRL2
21
ASI4
85
VSSO
149
D20
213
-NC-
22
VCCI
86
A27
150
D21
214
-NC-
23
ASI5
87
A28
151
VSSO
215
IRL1
24
ASI6
88
A29
152
-NC-
216
-NC-
25
ASI7
89
VSSI
153
-NC-
217
IRL0
26
VCCO
90
VSST
154
VCCI
218
-NC-
27
VSST
91
A30
155
D22
219
-NC-
28
CLK
92
VCCO
156
-NC-
220
CCCV
29
-NC-
93
A31
157
D23
221
FIPAR
30
VSSI
94
VCCI
158
VSST
222
VCCI
31
-NC-
95
601MODE
159
-NC-
223
FCCV
32
-NC-
96
-NC-
160
VSSI
224
CMODE
130
MATRA MHS
Rev. H (02 Dec. 96)
TSC691E
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
33
AOE
97
FLOW
161
-NC-
225
VSST
34
APAR
98
MCERR
162
D24
226
RESET
35
A0
99
HALT
163
-NC-
227
VSSI
36
A1
100
DPAR
164
D25
228
CHOLD
37
VCCI
101
-NC-
165
VCCO
229
FHOLD
38
A2
102
-NC-
166
VCCI
230
BHOLD
39
-NC-
103
D0
167
D26
231
-NC-
40
-NC-
104
VSSO
168
D27
232
MHOLDB
41
VSSO
105
D1
169
D28
233
MHOLDA
42
A3
106
D2
170
VSSO
234
MDS
43
-NC-
107
-NC-
171
D29
235
-NC-
44
-NC-
108
VSSI
172
D30
236
FP
45
A4
109
D3
173
VSSI
237
CEXC
46
A5
110
VCCO
174
VCCI
238
MEXC
47
-NC-
111
D4
175
D31
239
-NC-
48
-NC-
112
D5
176
DOE
240
-NC-
49
A6
113
-NC-
177
VCCI
241
FEXC
50
VCCO
114
D6
178
FINS2
242
-NC-
51
A7
115
VCCI
179
FINS1
243
VSSI
52
A8
116
D8
180
CINS1
244
VSSO
53
A9
117
D7
181
VCCO
245
INST
54
A10
118
-NC-
182
TOE
246
RD
55
VSSI
119
-NC-
183
VSSI
247
VCCI
56
VSSO
120
D9
184
TRST
248
LDSTO
57
-NC-
121
VCCO
185
CINS2
249
VCCO
58
A12
122
-NC-
186
TDI
250
WE
59
A11
123
-NC-
187
TCLK
251
CP
60
A14
124
VSSI
188
VSSI
252
VCCT
61
A13
125
VCCT
189
TMS
253
INULL
62
VCCI
126
VSSO
190
VCCI
254
VSSO
63
VCCI
127
VSSO
191
TDO
255
VSSI
64
VCCO
128
-NC-
192
VCCO
256
VSSO
MATRA MHS
Rev. H (02 Dec. 96)