UOT MIM-93M1AKL

MIM-93M1AKL
INFRARED RECEIVER MODULE
Description
The MIM-93M1AKL is 37.9 KHZ miniaturized infrared
receivers for remote control and other appplications
requiring improved ambient light rejection.
The separate PIN diode and preamplifier IC are assembled
on a single leadframe.
The epoxy package contains a special IR filter.
This module has excellent performance even in disturbed
ambient light applications and provides protection against
uncontrolled output pulses.
Features
l
Photo detector and preamplifier in one package
l
Internal filter for PCM frequency
l
High immunity against ambient light
5-Volt supply voltage; low power consumption
l
l
TTL and CMOS compatibility
unit : mm
BLOCK DIAGRAM
VS
TRAP
ABLC
Unity Opto Technology Co., Ltd.
BPF
TRIMMING
Output
fo
GND
07/06/2000
MIM-93M1AKL
Absolute Maximum Ratings
Item
@ Ta=25°C
Symbol
Ratings
Unit
Supply voltage
VCC
5.8
V
Operating temperature
Topr
-10 ~ + 60
°C
Storage temperature
Tstg
-20 ~ + 75
°C
Soldering temperature
Tsd
260
°C
Remark
Maximum 5 seconds
Electro-optical characteristics (Vcc=5V)
Parameter
Symbol
Current consumption
(Ta=25°C , Vcc=5V)
Min.
Typ.
Icc
Max.
Unit
5.0
mA
Response wavelength
p
940
nm
Tuning frequency
f0
37.9
KHZ
Remarks
Under no signal
- - - - - active low output - - - - -
Output form
H level output voltage
V0h
L level output voltage
4.2
V
V0l
0.5
V
H level output pulse width
Twh
400
800
s
L level output pulse width
Twl
400
800
s
L
10.0
Distance between emitter & detector
m
Half angle
±45
deg
Note 1
Horizonal direction
Test Method
A. Standard Transmitter
25cm
10kΩ PD3516
ON/OFF pulse width satisfied from 25 cm to detection limit
600µs
carrier frequency f0
duty 50%
Transmitter
Duty 50%
600µs
600µs
+5V
10kΩ
10µF
Vout
GND
Oscilloscope
Fig 1. Burst Wave
Fig 2. Standard Transmitter Measurement circuit
B. Detection Length Test
Transmitter output
θ
θ
Vout
D.U.T
L
θ: indicates horizontal and vertical directions
Unity Opto Technology Co., Ltd.
7/6/00
MIM-93M1AKL
B. Detection Length Test
Transmitter output
600µs 600µs
DUT output pulse
Twl
Twh
V0 h
V0 l
C. Pulse Width Test
Vcc **)
3
MIM-93M1AKL
102P
C
MIE-544A2
Decoder
1
2
GND
*) only necessary to supress power supply disturbances.
**) tolerated supply voltage range : 4.1V < Vcc < 5.8V
CHARACTERISTIC CURVES (TA=25 )
900
Output Pulse Width tPW(µs)
Supply Current Icc (mA)
2.8
2.7
2.6
2.4
2.2
800
Burst length * 600µs, cycle = 1.2ms
tpw: Average value of output from start
of signal input to 60th pulse
700
600
500
2.0
Input Level VIN (mVP-P)
400
2
3
6
4
5
Supply Voltage Vcc (V)
7
0.1
8
SUPPLY VOLTAGE vs. SUPPLY CURRENT
1
10
100
1000
Input Level (mVp-p)
INPUT LEVEL vs.OUTPUT PULSE WIDTH
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
Unity Opto Technology Co., Ltd.
07/06/2000
MIM-93M1AKL
Reliability
Test item
High temparature
High temp. & high humi.
Low temparature
Heat cycle
Dropping
Test condition
Ta=+60°C
Vcc=5.0 V
t=240H
Ta=+40°C 90%RH Vcc=5.0V
t=240H
Ta= -10°C Vcc=5.0V
t=240H
-20°C(0.5H) ~ +75°C(0.5H) 20cycle
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
Standard
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
NOTE 2. (electro-optical charactistics) shall be satisfied sfter leaving 2 hours in the
normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
Unity Opto Technology Co., Ltd.
7/6/00
MIM-93M1AKL
Guarantee period and scope
1.Guarantee period
One year after delivery to desired place .
2.Guarantee scope
A re-delivery of goods will be carried out if the cause of malfunction lies in our
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .
Unity Opto Technology Co., Ltd.
7/6/00