XICOR X24C04S8I-3.5

X24C04
X24C04
4K
512 x 8 Bit
Serial E2PROM
FEATURES
DESCRIPTION
•
•
The X24C04 is a CMOS 4096 bit serial E2PROM,
internally organized 512 x 8. The X24C04 features a
serial interface and software protocol allowing operation
on a simple two wire bus.
•
•
•
•
•
•
2.7V to 5.5V Power Supply
Low Power CMOS
—Active Read Current Less Than 1 mA
—Active Write Current Less Than 3 mA
—Standby Current Less Than 50 µA
Internally Organized 512 x 8
2 Wire Serial Interface
—Bidirectional Data Transfer Protocol
Sixteen Byte Page Write Mode
—Minimizes Total Write Time Per Byte
Self Timed Write Cycle
—Typical Write Cycle Time of 5 ms
High Reliability
—Endurance: 100,000 Cycles
—Data Retention: 100 Years
8 Pin Mini-DIP, 8 Pin SOIC and 14 Pin SOIC
Packages
The X24C04 is fabricated with Xicor’s advanced CMOS
Textured Poly Floating Gate Technology.
The X24C04 utilizes Xicor’s proprietary DirectWrite™
cell providing a minimum endurance of 100,000 cycles
and a minimum data retention of 100 years.
FUNCTIONAL DIAGRAM
(8) VCC
(4) VSS
(7) TEST
(5) SDA
H.V. GENERATION
TIMING
& CONTROL
START CYCLE
START
STOP
LOGIC
CONTROL
LOGIC
(6) SCL
SLAVE ADDRESS
REGISTER
+COMPARATOR
LOAD
(3) A2
(2) A1
INC
E2PROM
32 X 128
XDEC
WORD
ADDRESS
COUNTER
(1) A0
R/W
YDEC
8
CK
PIN
DATA REGISTER
DOUT
DOUT
ACK
3839 FHD F01
DirectWrite™ is a trademark of Xicor, Inc.
© Xicor, 1991 Patents Pending
3839-1
1
Characteristics subject to change without notice
X24C04
PIN DESCRIPTIONS
PIN CONFIGURATION
Serial Clock (SCL)
The SCL input is used to clock all data into and out of the
device.
DIP/SOIC
Serial Data (SDA)
A0
1
SDA is a bidirectional pin used to transfer data into and
out of the device. It is an open drain output and may be
wire-ORed with any number of open drain or open
collector outputs.
A1
2
A2
3
VSS
4
A0 is unused by the X24C04, however, it must be tied to
VSS to insure proper device operation.
Address (A1, A2)
The Address inputs are used to set the appropriate bits
of the seven bit slave address. These inputs can be used
static or actively driven. If used statically they must be
tied to VSS or VCC as appropriate. If driven they must be
driven to VSS or to VCC.
Address Inputs
Serial Data
Serial Clock
Hold at VSS
Ground
Supply Voltage
No Connect
TEST
6
SCL
5
SDA
NC
1
14
NC
A0
A1
2
13
3
12
VCC
TEST
NC
4
X24C04 11
A2
VSS
NC
5
10
SCL
6
9
SDA
7
8
NC
NC
3839 FHD F03
PIN NAMES
A0–A2
SDA
SCL
TEST
VSS
VCC
NC
7
SOIC
Address (A0)
Description
VCC
3839 FHD F02
An open drain output requires the use of a pull-up
resistor. For selecting typical values, refer to the Pull-Up
Resistor selection graph at the end of this data sheet.
Symbol
X24C04
8
3839 PGM T01
2
X24C04
DEVICE OPERATION
Clock and Data Conventions
The X24C04 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data
onto the bus as a transmitter, and the receiving device
as the receiver. The device controlling the transfer is a
master and the device being controlled is the slave. The
master will always initiate data transfers, and provide
the clock for both transmit and receive operations.
Therefore, the X24C04 will be considered a slave in all
applications.
Data states on the SDA line can change only during SCL
LOW. SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. Refer to
Figures 1 and 2.
Start Condition
All commands are preceded by the start condition,
which is a HIGH to LOW transition of SDA when SCL is
HIGH. The X24C04 continuously monitors the SDA and
SCL lines for the start condition and will not respond to
any command until this condition has been met.
Figure 1. Data Validity
SCL
SDA
DATA STABLE
DATA
CHANGE
3839 FHD F06
Figure 2. Definition of Start and Stop
SCL
SDA
START BIT
STOP BIT
3
3839 FHD F07
X24C04
Stop Condition
The X24C04 will respond with an acknowledge after
recognition of a start condition and its slave address. If
both the device and a write operation have been selected, the X24C04 will respond with an acknowledge
after the receipt of each subsequent eight bit word.
All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA when SCL
is HIGH. The stop condition is also used by the X24C04
to place the device in the standby power mode after a read
sequence. A stop condition can only be issued after the
transmitting device has released the bus.
In the read mode the X24C04 will transmit eight bits of
data, release the SDA line and monitor the line for an
acknowledge. If an acknowledge is detected and no
stop condition is generated by the master, the X24C04
will continue to transmit data. If an acknowledge is not
detected, the X24C04 will terminate further data transmissions. The master must then issue a stop condition
to return the X24C04 to the standby power mode and
place the device into a known state.
Acknowledge
Acknowledge is a software convention used to indicate
successful data transfer. The transmitting device, either
master or slave, will release the bus after transmitting
eight bits. During the ninth clock cycle the receiver will
pull the SDA line LOW to acknowledge that it received
the eight bits of data. Refer to Figure 3.
Figure 3. Acknowledge Response From Receiver
SCL FROM
MASTER
1
8
9
DATA
OUTPUT
FROM
TRANSMITTER
DATA
OUTPUT
FROM
RECEIVER
START
ACKNOWLEDGE
3839 FHD F08
4
X24C04
DEVICE ADDRESSING
The last bit of the slave address defines the operation to
be performed. When set to one a read operation is
selected, when set to zero a write operation is selected.
Following a start condition the master must output the
address of the slave it is accessing. The most significant
four bits of the slave are the device type identifier (see
Figure 4). For the X24C04 this is fixed as 1010[B].
Following the start condition, the X24C04 monitors the
SDA bus comparing the slave address being transmitted with its slave address (device type and state of A1
and A2 inputs). Upon a correct compare the X24C04
outputs an acknowledge on the SDA line. Depending on
the state of the R/W bit, the X24C04 will execute a read
or write operation.
Figure 4. Slave Address
HIGH
ORDER
DEVICE
WORD
ADDRESS ADDRESS
DEVICE TYPE
IDENTIFIER
1
0
1
0
A2
A1
A0
WRITE OPERATIONS
Byte Write
R/W
For a write operation, the X24C04 requires a second
address field. This address field is the word address,
comprised of eight bits, providing access to any one of the
512 words of memory. Upon receipt of the word address
the X24C04 responds with an acknowledge, and awaits
the next eight bits of data, again responding with an
acknowledge. The master then terminates the transfer by
generating a stop condition, at which time the X24C04
begins the internal write cycle to the nonvolatile memory.
While the internal write cycle is in progress the X24C04
inputs are disabled, and the device will not respond to any
requests from the master. Refer to Figure 5 for the
address, acknowledge and data transfer sequence.
3839 FHD F09
The next two significant bits address a particular device.
A system could have up to four X24C04 devices on the
bus (see Figure 10). The four addresses are defined by
the state of the A1 and A2 inputs.
The next bit of the slave address is an extension of the
array’s address and is concatenated with the eight bits
of address in the word address field, providing direct
access to the whole 512 x 8 array.
Figure 5. Byte Write
S
T
BUS ACTIVITY: A
R
MASTER
T
SDA LINE
BUS ACTIVITY:
X24C04
SLAVE
ADDRESS
WORD
ADDRESS
S
T
O
P
DATA
S
P
A
C
K
A
C
K
A
C
K
3839 FHD F10
5
X24C04
Page Write
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read
operation, the master must either issue a stop condition
during the ninth cycle or hold SDA HIGH during the ninth
clock cycle and then issue a stop condition.
The X24C04 is capable of a sixteen byte page write
operation. It is initiated in the same manner as the byte
write operation, but instead of terminating the write cycle
after the first data word is transferred, the master can
transmit up to fifteen more words. After the receipt of each
word, the X24C04 will respond with an acknowledge.
Flow 1. ACK Polling Sequence
After the receipt of each word, the four low order address
bits are internally incremented by one. The high order five
bits of the address remain constant. If the master should
transmit more than sixteen words prior to generating the
stop condition, the address counter will “roll over” and the
previously written data will be overwritten. As with the byte
write operation, all inputs are disabled until completion of
the internal write cycle. Refer to Figure 6 for the address,
acknowledge and data transfer sequence.
WRITE OPERATION
COMPLETED
ENTER ACK POLLING
ISSUE
START
ISSUE SLAVE
ADDRESS AND R/W = 0
Acknowledge Polling
The disabling of the inputs can be used to take advantage of the typical 5 ms write cycle time. Once the stop
condition is issued to indicate the end of the host’s write
operation the X24C04 initiates the internal write cycle.
ACK polling can be initiated immediately. This involves
issuing the start condition followed by the slave address
for a write operation. If the X24C04 is still busy with the
write operation no ACK will be returned. If the X24C04
has completed the write operation an ACK will be
returned and the host can then proceed with the next
read or write operation. Refer to Flow 1.
ACK
RETURNED?
ISSUE STOP
NO
YES
NEXT
OPERATION
A WRITE?
NO
YES
READ OPERATIONS
Read operations are initiated in the same manner as
write operations with the exception that the R/W bit of the
slave address is set to a one. There are three basic read
operations: current address read, random read and
sequential read.
ISSUE BYTE
ADDRESS
ISSUE STOP
PROCEED
PROCEED
3839 FHD F12
Figure 6. Page Write
S
T
BUS ACTIVITY: A
R
MASTER
T
SDA LINE
BUS ACTIVITY:
X24C04
WORD
ADDRESS (n)
SLAVE
ADDRESS
DATA n
DATA n+1
S
T
O
P
DATA n+15
S
P
A
C
K
A
C
K
A
C
K
NOTE: In this example n = xxxx 000 (B); x = 1 or 0
6
A
C
K
A
C
K
3839 FHD F11
X24C04
Current Address Read
Random Read
Internally the X24C04 contains an address counter that
maintains the address of the last word accessed,
incremented by one. Therefore, if the last access (either
a read or write) was to address n, the next read operation
would access data from address n + 1. Upon receipt of
the slave address with the R/W bit set to one, the
X24C04 issues an acknowledge and transmits the eight
bit word. The read operation is terminated by the master;
by not responding with an acknowledge and by issuing
a stop condition. Refer to Figure 7 for the sequence of
address, acknowledge and data transfer.
Random read operations allow the master to access
any memory location in a random manner. Prior to
issuing the slave address with the R/W bit set to one,
the master must first perform a “dummy” write operation. The master issues the start condition, and the
slave address followed by the word address it is to read.
After the word address acknowledge, the master immediately reissues the start condition and the slave
address with the R/W bit set to one. This will be followed
by an acknowledge from the X24C04 and then by the
eight bit word. The read operation is terminated by the
master; by not responding with an acknowledge and by
issuing a stop condition. Refer to Figure 8 for the
address, acknowledge and data transfer sequence.
Figure 7. Current Address Read
S
T
BUS ACTIVITY: A
R
MASTER
T
SDA LINE
SLAVE
ADDRESS
DATA
S
S
T
O
P
P
A
C
K
BUS ACTIVITY:
X24C04
3839 FHD F13
Figure 8. Random Read
S
T
BUS ACTIVITY: A
R
MASTER
T
SDA LINE
BUS ACTIVITY:
X24C04
SLAVE
ADDRESS
S
T
A
R
T
WORD
ADDRESS n
SLAVE
ADDRESS
DATA n
S
S
A
C
K
A
C
K
S
T
O
P
P
A
C
K
3839 FHD F14
7
X24C04
Sequential Read
The data output is sequential, with the data from address
n followed by the data from n + 1. The address counter
for read operations increments all address bits, allowing
the entire memory contents to be serially read during
one operation. At the end of the address space (address
511), the counter “rolls over” to address 0 and the
X24C04 continues to output data for each acknowledge
received. Refer to Figure 9 for the address, acknowledge and data transfer sequence.
Sequential Read can be initiated as either a current
address read or random access read. The first word is
transmitted as with the other modes, however, the
master now responds with an acknowledge, indicating it
requires additional data. The X24C04 continues to output data for each acknowledge received. The read
operation is terminated by the master; by not responding
with an acknowledge and by issuing a stop condition.
Figure 9. Sequential Read
SLAVE
BUS ACTIVITY: ADDRESS
MASTER
A
C
K
A
C
K
S
T
O
P
A
C
K
SDA LINE
BUS ACTIVITY:
X24C04
P
A
C
K
DATA n+1
DATA n
DATA n+2
DATA n+x
3839 FHD F16
Figure 10. Typical System Configuration
VCC
PULL-UP
RESISTORS
SDA
SCL
MASTER
TRANSMITTER/
RECEIVER
SLAVE
RECEIVER
SLAVE
TRANSMITTER/
RECEIVER
MASTER
TRANSMITTER
MASTER
TRANSMITTER/
RECEIVER
3839 FHD F17
8
X24C04
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ............................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
Industrial
Military
0°C
–40°C
–55°C
70°C
+85°C
+125°C
X24C04
X24C04-3.5
X24C04-3
X24C04-2.7
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7V to 5.5V
3836 PGM T02
3836 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Limits
Symbol
Parameter
ICC1
ICC2
VCC Supply Current (Read)
VCC Supply Current (Write)
ISB1(1)
Min.
Max.
Units
1
3
mA
VCC Standby Current
150
µA
ISB2(1)
VCC Standby Current
50
µA
ILI
ILO
VlL(2)
VIH(2)
VOL
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
10
10
–1.0
VCC x 0.3
VCC x 0.7 VCC + 0.5
0.4
µA
µA
V
V
V
Test Conditions
SCL = VCC x 0.1/VCC x 0.9 Levels
@ 100 KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC,
VCC = 3V
VIN = GND to VCC
VOUT = GND to VCC
IOL = 3 mA
3839 PGM T03
CAPACITANCE TA = 25°C, f = 1.0MHz, VCC = 5V
Symbol
Parameter
Max.
Units
Test Conditions
CI/O(3)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL)
8
6
pF
pF
VI/O = 0V
VIN = 0V
CIN(3)
3839 PGM T05
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
9
X24C04
A.C. CONDITIONS OF TEST
Input Pulse Levels
EQUIVALENT A.C. LOAD CIRCUIT
5.0V
VCC x 0.1 to VCC x 0.9
1533Ω
Input Rise and
Fall Times
Input and Output
Timing Levels
10 ns
Output
100pF
VCC x 0.5
3839 PGM T02
A.C. CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Read & Write Cycle Limits
Symbol
fSCL
TI
tAA
tBUF
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
Parameter
SCL Clock Frequency
Noise Suppression Time
Constant at SCL, SDA Inputs
SCL Low to SDA Data Out Valid
Time the Bus Must Be Free Before a
New Transmission Can Start
Start Condition Hold Time
Clock Low Period
Clock High Period
Start Condition Setup Time
(for a Repeated Start Condition)
Data In Hold Time
Data In Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
Min.
Max.
Units
0
100
100
KHz
ns
0.3
4.7
3.5
µs
µs
4.0
4.7
4.0
4.7
µs
µs
µs
µs
0
250
µs
ns
µs
ns
µs
ns
1
300
4.7
300
3839 PGM T06
POWER-UP TIMING
Symbol
Parameter
Max.
Units
tPUR(4)
tPUW(4)
Power-up to Read Operation
Power-up to Write Operation
1
5
ms
ms
3839 PGM T07
Bus Timing
tHIGH
tF
tLOW
tR
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA IN
tAA
tDH
tBUF
SDA OUT
3839 FHD F04
Notes: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
10
X24C04
Write Cycle Limits
Symbol
Parameter
tWR(6)
Write Cycle Time
Min.
Typ.(5)
Max.
Units
5
10
ms
3839 PGM T08
The write cycle time is the time from a valid stop
condition of a write sequence to the end of the internal
erase/program cycle. During the write cycle, the X24C04
bus interface circuits are disabled, SDA is allowed to
remain high, and the device does not respond to its slave
address.
Write Cycle Timing
SCL
SDA
ACK
8th BIT
WORD n
tWR
STOP
CONDITION
START
CONDITION
X24C04
ADDRESS
3839 FHD F05
Notes: (5) Typical values are for TA = 25°C and nominal supply voltage (5V).
(6) tWR is the minimum cycle time from the system perspective when polling techniques are not used. It is the maximum time the
device requires to perform the internal write operation.
Guidelines for Calculating Typical
Values of Bus Pull-Up Resistors
RESISTANCE (KΩ)
120
RMIN =
100
80
SYMBOL TABLE
WAVEFORM
VCC MAX
=1.8KΩ
IOL MIN
RMAX =
tR
CBUS
MAX.
RESISTANCE
60
40
20
MIN.
RESISTANCE
0
0
20
40
60
INPUTS
OUTPUTS
Must be
steady
Will be
steady
May change
from Low to
High
Will change
from Low to
High
May change
from High to
Low
Will change
from High to
Low
Don’t Care:
Changes
Allowed
Changing:
State Not
Known
N/A
Center Line
is High
Impedance
80 100 120
BUS CAPACITANCE (pF)
3839 FHD F18
11
X24C04
PACKAGING INFORMATION
8-LEAD PLASTIC SMALL OUTLINE
GULL WING PACKAGE TYPE S
8-LEAD PLASTIC DUAL
IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.150 (3.80)
0.158 (4.00)
0.092 (2.34)
DIA. NOM.
0.228 (5.80)
0.244 (6.20)
0.255 (6.47)
0.245 (6.22)
PIN 1 INDEX
PIN 1 INDEX
PIN 1
PIN 1
0.300
(7.62) REF.
0.014 (0.35)
0.019 (0.49)
0.060 (1.52)
0.020 (0.51)
HALF SHOULDER
WIDTH ON ALL END
PINS OPTIONAL
0.188 (4.78)
0.197 (5.00)
0.140 (3.56)
0.130 (3.30)
SEATING
PLANE
(4X) 7°
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.020 (0.51)
0.015 (0.38)
0.062 (1.57)
0.058 (1.47)
0.150 (3.81)
0.125 (3.18)
0.053 (1.35)
0.069 (1.75)
0.020 (0.51)
0.016 (0.41)
0.110 (2.79)
0.090 (2.29)
0.010 (0.25)
X 45°
0.020 (0.50)
0.015 (0.38)
MAX.
0.325 (8.25)
0.300 (7.62)
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.027 (0.683)
0.037 (0.937)
TYP. 0.010 (0.25)
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
12
0°
15°
X24C04
PACKAGING INFORMATION
14-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.336 (8.55)
0.345 (8.75)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.010 (0.25)
X 45°
0.020 (0.50)
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.027 (0.683)
0.037 (0.937)
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
13
X24C04
ORDERING INFORMATION
X24C04
P
T
-V
VCC Limits
Blank = 4.5V to 5.5V
3.5 = 3.5V to 5.5V
3 = 3.0 to 5.5V
2.7 = 2.7V to 5.5V
Device
Temperature Range
Blank = Commercial = 0°C to +70°C
I = Industrial = –40°C to +85°C
M = Military = –55°C to +125°C
Package
P = 8-Lead Plastic DIP
S8 = 8-Lead SOIC
S14 = 14-Lead SOIC
Part Mark Convention
X24C04
Blank = 8-Lead SOIC
P = 8-Lead Plastic DIP
S8 = 8-Lead SOIC
S14 = 14-Lead SOIC
X
X
Blank = 4.5V to 5.5V, 0°C to +70°C
I = 4.5V to 5.5V, –40°C to +85°C
B = 3.5V to 5.5V, 0°C to +70°C
C = 3.5V to 5.5V, –40°C to +85°C
D = 3.0V to 5.5V, 0°C to +70°C
E = 3.0V to 5.5V, –40°C to +85°C
F = 2.7V to 5.5V, 0°C to +70°C
G = 2.7V to 5.5V, –40°C to +85°C
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty,
express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement.
Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and
prices at any time and without notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are
implied.
U.S. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475;
4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and
additional patents pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error
detection and correction, redundancy and back-up features to prevent such an occurence.
Xicor's products are not authorized for use in critical components in life support devices or systems.
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant
injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
14
X24C04
8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.260 (6.60)
0.240 (6.10)
PIN 1 INDEX
PIN 1
0.300
(7.62) REF.
HALF SHOULDER WIDTH ON
ALL END PINS OPTIONAL
0.145 (3.68)
0.128 (3.25)
SEATING
PLANE
0.025 (0.64)
0.015 (0.38)
0.065 (1.65)
0.045 (1.14)
0.150 (3.81)
0.125 (3.18)
0.020 (0.51)
0.016 (0.41)
0.110 (2.79)
0.090 (2.29)
0.015 (0.38)
MAX.
0.060 (1.52)
0.020 (0.51)
0.325 (8.25)
0.300 (7.62)
0°
15°
TYP. 0.010 (0.25)
NOTE:
1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
3926 FHD F01
15
X24C04
8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.010 (0.25)
X 45°
0.020 (0.50)
0.050" TYPICAL
0.050"
TYPICAL
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.410)
0.037 (0.937)
0.030"
TYPICAL
8 PLACES
FOOTPRINT
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESIS IN MILLIMETERS)
3926 FHD F22
16
X24C04
14-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.020 (0.51)
0.336 (8.55)
0.345 (8.75)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.10)
0.010 (0.25)
0.050 (1.27)
0.050" Typical
0.010 (0.25)
X 45°
0.020 (0.50)
0° – 8°
0.050" Typical
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.41)
0.037 (0.937)
FOOTPRINT
0.030" Typical
14 Places
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F10
17
X24C04
8-LEAD HERMETIC DUAL IN-LINE PACKAGE TYPE D
0.405 (10.29)
––
0.310 (7.87)
0.220 (5.59)
PIN 1
0.005 (0.13) MIN.
0.300 (7.62)
REF.
0.200 (5.08)
0.140 (3.56)
SEATING
PLANE
0.150 (3.81) MIN.
0.055 (1.40) MAX.
0.060 (1.52)
0.015 (0.38)
0.200 (5.08)
0.125 (3.18)
0.065 (1.65)
0.038 (0.97)
TYP. 0.060 (1.52)
0.110 (2.79)
0.090 (2.29)
TYP. 0.100 (2.54)
0.023 (0.58)
0.014 (0.36)
TYP. 0.017 (0.43)
0.320 (8.13)
0.290 (7.37)
TYP. 0.311 (7.90)
0°
15°
0.015 (0.38)
0.008 (0.20)
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F05
18