ZL50410 Managed 8-Port 10/100M + 1-Port 10/100/1000M Ethernet Switch Data Sheet Features • • • • December 2004 Integrated Single-Chip 10/100/1000 Ethernet Switch • Eight 10/100 Mbps auto-negotiating Fast Ethernet (FE) ports with RMII, MII, GPSI, Reverse MII & Reverse GPSI interface options • One 10/100/1000 Mbps auto-negotiating port with GMII & MII interface options, that can be used as a WAN uplink or as a 9th port • a 10/100 Mbps Fast Ethernet (FE) CPU port with Reverse MII interface option Operates stand-alone or can be cascaded with a second ZL50410 to reach 16 ports Embedded 2 Mbits (256 KBytes) internal memory • supports up to 4 K byte frames L2 switching • MAC address self learning, up to 4 K MAC addresses using internal table • Supports IP Multicast with IGMP snooping, up to 4 K IP Multicast groups • Supports the following spanning standards - IEEE 802.1D spanning tree - IEEE 802.1w rapid spanning tree • Supports Ethernet multicasting and broadcasting and flooding control C P U Ordering Information ZL50410GDC208 Pin LBGA -40°C to +85°C • • • VLAN Support • Supports port-based VLAN and tagged-based VLAN (IEEE 802.1Q), up to 4 K VLANs • Supports both shared VLAN learning (SVL) and independent VLAN learning (IVL) • Supports Private VLAN Edge (Protected Ports) CPU access supports the following interface options: • 8/16-bit parallel and Serial+MII interface in managed mode • Serial interface in lightly managed mode, or in unmanaged mode with optional I2C EEPROM interface Failover Features • Rapid link failure detection using hardware-generated heartbeat packets 8/16-bit or Serial ZL50410 GMII / MII MII 8-Port 10/100M + 1G Ethernet Switch EEPROM 10/100/ 1000 PHY I2C RMII / MII / GPSI Quad 10/100 PHY Quad 10/100 PHY Figure 1 - System Block Diagram 1 Zarlink Semiconductor Inc. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright 2003, Zarlink Semiconductor Inc. All Rights Reserved. ZL50410 • • • • • • • • • • • • • • • • Data Sheet • link failover in less than 50 ms Rate Control (both ingress and egress) • Bandwidth rationing, Bandwidth on demand, SLA (Service Level Agreement) • Smooth out traffic to uplink port • Ingress Rate Control - Back pressure - Flow Control - WRED (Weighted Random Early Discard) • Egress Rate Control • Down to 16 kbps Rate Control granularity Per queue traffic shaper on uplink port Packet Filtering and Port Security • Static address filtering for source and/or destination MAC • Static MAC address not subject to aging • Secure mode freezes MAC address learning (each port may independently use this mode) • Supports port authentication (IEEE 802.1x) QoS Support • Supports IEEE 802.1p/Q Quality of Service with 2 transmission priority queues (4 for uplink port), with strict priority and/or WFQ service disciplines • Provides 2 levels of dropping precedence with WRED mechanism • User controls the WRED thresholds. • Buffer management: per class and per port buffer reservations • Port-based priority: VLAN priority in a tagged frame can be overwritten by the priority of Port VLAN ID Supports per-system option to enable flow control for best effort frames even on QoS enabled ports Classification based on: • Port based priority • VLAN Priority field in VLAN tagged frame • DS/TOS field in IP packet • UDP/TCP logical ports: 8 hard-wired and 8 programmable ports, including one programmable range The precedence of the above classifications is programmable Supports IEEE 802.3ad link aggregation • Up to 8 trunk groups, with up to 8 ports per group • Allows trunking of ports located on cascaded chip • Supports load sharing among trunk ports based on: - Source port - Source and/or destination MAC address Supports module hot swap on all ports MIB Statistics counters for all ports Full Duplex Ethernet IEEE 802.3x Flow Control Backpressure flow control for Half Duplex ports Hardware auto-negotiation through MII management interface (MDIO) for Ethernet ports Built-in reset logic triggered by system malfunction Built-In Self Test for internal SRAM IEEE-1149.1 (JTAG) test port 2 Zarlink Semiconductor Inc. ZL50410 Data Sheet Description The ZL50410 is a low density, low cost, high performance, non-blocking Ethernet switch chip. A single chip provides 8 ports at 10/100 Mbps, 1 uplink port at 10/100/1000 Mbps, and a CPU interface for managed, lightly managed and unmanaged switch applications. The chip supports up to 4 K MAC addresses and up to 4 K tagged-based Virtual LANs (VLANs). It also supports the Private VLAN Edge feature, allowing the ability to set up protected ports in a tagged-based VLAN system. With strict priority and/or WFQ transmission scheduling and WRED dropping schemes, the ZL50410 provides powerful QoS functions for various multimedia and mission-critical applications. The chip provides 2 transmission priorities (4 priorities for uplink port) and 2 levels of dropping precedence. Each packet is assigned a transmission priority and dropping precedence based on the VLAN priority field in a VLAN tagged frame, or the DS/TOS field, or the UDP/TCP logical port fields in IP packets. The ZL50410 recognizes a total of 16 UDP/TCP logical ports, 8 hard-wired and 8 programmable (including one programmable range). The ZL50410 provides the ability to monitor a link, detect a simple link failure, and provide notification of the failure to the CPU. The CPU can then failover that link to an alternate link. The ZL50410 supports up to 8 groups of port trunking/load sharing. Each group can contain up to 8 ports. Port trunking/load sharing can be used to group ports between interlinked switches to increase the effective network bandwidth. In half-duplex mode, all ports support backpressure flow control, to minimize the risk of losing data during long activity bursts. In full-duplex mode, IEEE 802.3x flow control is provided. The ZL50410 also supports a per-system option to enable flow control for best effort frames, even on QoS-enabled ports. Statistical information for SNMP and the Remote Monitoring Management Information Base (RMON MIB) are collected independently for all ports. Access to these statistical counters/registers is provided via the CPU interface. SNMP Management frames can be received and transmitted via the CPU interface, creating a complete network management solution. The ZL50410 is fabricated using 0.18 micron technology. The ZL50410 is packaged in a 208-pin Ball Grid Array package. 3 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 1.0 BGA and Ball Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.1 BGA Views (Top-View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.2 Power and Ground Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.3 Ball Signal Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1.4 Signal Mapping and Internal pull-up/Down Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.5 Bootstrap Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1.5.1 Recommended Default Boostrap Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1.6 Default Switch Configuration and Initialization Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2.0 Block Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.1 Internal Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.2 MAC Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.2.1 RMII MAC Module (RMAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.2.1.1 GPSI (7WS) Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.2.2 CPU MAC Module (CMAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.2.3 MII MAC Module (MMAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.2.4 PHY Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.3 Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.4 Frame Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2.5 Search Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.6 Heartbeat Packet Generation and Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.7 Timeout Reset Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2.8 JTAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.0 Management and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.1 Register Configuration, Frame Transmission, and Frame Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.1.1 Register Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.1.2 Rx/Tx of Standard Ethernet Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.1.3 Control Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.2 I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 3.2.1 Start Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 3.2.2 Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.2.3 Data Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.2.4 Acknowledgment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.2.5 Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.2.6 Stop Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.3 Synchronous Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.3.1 Write Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 3.3.2 Read Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.0 Data Forwarding Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4.1 Unicast Data Frame Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4.2 Multicast Data Frame Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4.3 Frame Forwarding To and From CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.0 Search Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.1 Search Engine Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.2 Basic Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.3 Search, Learning, and Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.3.1 MAC Search. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.3.2 Learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.3.3 Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 5.4 MAC Address Filtering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 5.5 Protocol Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 5.6 Logical Port Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 5.7 Quality of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 5.8 Priority Classification Rule. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5.9 Port Based VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.0 Frame Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.1 Data Forwarding Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.2 Frame Engine Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.2.1 FCB Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.2.2 Rx Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.2.3 RxDMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.2.4 TxQ Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.2.5 Port Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 6.2.6 TxDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 7.0 Quality of Service and Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 7.1 Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 7.2 Two QoS Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7.2.1 Strict Priority. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7.2.2 Weighted Fair Queuing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7.3 WRED Drop Threshold Management Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7.4 Shaper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.5 Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.6 Buffer Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.6.1 Dropping When Buffers Are Scarce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7.7 Flow Control Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7.7.1 Unicast Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.7.2 Multicast Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.8 Mapping to IETF Diffserv Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.9 Failover Backplane Feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8.0 Port Trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 8.1 Features and Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 8.2 Unicast Packet Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 8.3 Multicast Packet Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 9.0 Traffic Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 9.1 Mirroring Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 9.2 Using port mirroring for loop back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 10.0 Clocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.1 Clock Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.1.1 System Clock (SCLK) speed requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.1.2 RMAC Reference Clock (M_CLK) speed requirement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.1.3 MMAC Reference Clock (REF_CLK) speed requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.1.4 JTAG Test Clock (TCK) speed requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.2 Clock Generation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.2.1 MDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.2.2 SCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.2.3 Ethernet Interface Clocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 11.0 Hardware Statistics Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 11.1 Hardware Statistics Counters List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 11.2 IEEE 802.3 HUB Management (RFC 1516) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 11.2.1 Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 11.2.1.1 ReadableOctet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 11.2.1.2 ReadableFrame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.2.1.3 FCSErrors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.2.1.4 AlignmentErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 5 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 11.2.1.5 FrameTooLongs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.2.1.6 ShortEvents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.7 Runts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.8 Collisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.9 LateEvents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.10 VeryLongEvents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.11 DataRateMisatches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.12 AutoPartitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.2.1.13 TotalErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3 IEEE 802.1 Bridge Management (RFC 1286) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3.1 Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3.1.1 InFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3.1.2 OutFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3.1.3 InDiscards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3.1.4 DelayExceededDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.3.1.5 MtuExceededDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.4 RMON – Ethernet Statistic Group (RFC 1757) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.4.1 Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.4.1.1 Drop Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.4.1.2 Octets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 11.4.1.3 BroadcastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.4.1.4 MulticastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.4.1.5 CRCAlignErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.4.1.6 UndersizePkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.4.1.7 OversizePkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11.4.1.8 Fragments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 11.4.1.9 Jabbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 11.4.1.10 Collisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 11.4.1.11 Packet Count for Different Size Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 11.5 Miscellaneous Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 12.0 Register Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 12.1 ZL50400 Register Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 12.2 Directly Accessed Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 12.2.1 INDEX_REG0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 12.2.2 DATA_FRAME_REG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 12.2.3 CONTROL_FRAME_REG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 12.2.4 COMMAND&STATUS Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 12.2.5 Interrupt Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 12.2.6 Control Command Frame Buffer1 Access Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 12.2.7 Control Command Frame Buffer2 Access Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 12.3 Indirectly Accessed Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 12.3.1 (Group 0 Address) MAC Ports Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 12.3.1.1 ECR1Pn: Port n Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 12.3.1.2 ECR2Pn: Port n Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 12.3.1.3 ECR3Pn: Port n Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 12.3.1.4 ECR4Pn: Port n Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 12.3.1.5 BUF_LIMIT – Frame Buffer Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 12.3.1.6 FCC – Flow Control Grant Period. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 12.3.2 (Group 1 Address) VLAN Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 12.3.2.1 AVTCL – VLAN Type Code Register Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 12.3.2.2 AVTCH – VLAN Type Code Register High. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 12.3.2.3 PVMAP00_0 – Port 0 Configuration Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 6 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 12.3.2.4 PVMAP00_1 – Port 0 Configuration Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 12.3.2.5 PVMAP00_3 – Port 0 Configuration Register 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 12.3.2.6 PVMAPnn_0,1,3 – Ports 1~9 Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 12.3.2.7 PVMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 12.3.3 (Group 2 Address) Port Trunking Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 12.3.3.1 TRUNKn– Trunk Group 0~7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 12.3.3.2 TRUNKn_HASH10 – Trunk group n hash result 1/0 destination port number . . . . . . . . . . . 74 12.3.3.3 TRUNKn_HASH32 – Trunk group n hash result 3/2 destination port number . . . . . . . . . . . 74 12.3.3.4 TRUNKn_HASH54 – Trunk group n hash result 5/4 destination port number . . . . . . . . . . . 75 12.3.3.5 TRUNKn_HASH76 – Trunk group n hash result 7/6 destination port number . . . . . . . . . . . 75 Multicast Hash Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 12.3.3.6 MULTICAST_HASHn-0 – Multicast hash result 0~7 mask byte 0 . . . . . . . . . . . . . . . . . . . . 76 12.3.3.7 MULTICAST_HASHn-1 – Multicast hash result 0~7 mask byte 1 . . . . . . . . . . . . . . . . . . . . 76 12.3.4 (Group 3 Address) CPU Port Configuration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 12.3.4.1 MAC0 – CPU MAC address byte 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 12.3.4.2 MAC1 – CPU MAC address byte 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 12.3.4.3 MAC2 – CPU MAC address byte 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 12.3.4.4 MAC3 – CPU MAC address byte 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 12.3.4.5 MAC4 – CPU MAC address byte 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 12.3.4.6 MAC5 – CPU MAC address byte 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 12.3.4.7 INT_MASK0 – Interrupt Mask. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 12.3.4.8 INTP_MASK0 – Interrupt Mask for MAC Port 0,1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 12.3.4.9 INTP_MASKn – Interrupt Mask for MAC Ports 2~9 Registers . . . . . . . . . . . . . . . . . . . . . . . 78 12.3.4.10 RQS – Receive Queue Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 12.3.4.11 RQSS – Receive Queue Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 12.3.4.12 MAC01 – Increment MAC port 0,1 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 12.3.4.13 MAC23 – Increment MAC port 2,3 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 12.3.4.14 MAC45 – Increment MAC port 4,5 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 12.3.4.15 MAC67 – Increment MAC port 6,7 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 12.3.4.16 MAC9 – Increment MAC port 9 address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 12.3.4.17 CPUQINS0 - CPUQINS6 – CPU Queue Insertion Command . . . . . . . . . . . . . . . . . . . . . . 80 12.3.4.18 CPUQINSRPT – CPU Queue Insertion Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 12.3.4.19 CPUGRNHDL0 - CPUGRNHDL1 – CPU Allocated Granule Pointer . . . . . . . . . . . . . . . . . 81 12.3.4.20 CPURLSINFO0 - CPURLSINFO4 – Receive Queue Status . . . . . . . . . . . . . . . . . . . . . . . 81 12.3.4.21 CPUGRNCTR – CPU Granule Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 12.3.5 (Group 4 Address) Search Engine Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 12.3.5.1 AGETIME_LOW – MAC address aging time Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 12.3.5.2 AGETIME_HIGH –MAC address aging time High . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 12.3.5.3 SE_OPMODE – Search Engine Operation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 12.3.6 (Group 5 Address) Buffer Control/QOS Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 12.3.6.1 QOSC – QOS Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 12.3.6.2 UCC – Unicast Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.3.6.3 MCC – Multicast Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.3.6.4 MCCTH – Multicast Threshold Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.3.6.5 RDRC0 – WRED Rate Control 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.3.6.6 RDRC1 – WRED Rate Control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.3.6.7 RDRC2 – WRED Rate Control 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.3.6.8 SFCB – Share FCB Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.3.6.9 C1RS – Class 1 Reserve Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.3.6.10 C2RS – Class 2 Reserve Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.3.6.11 C3RS – Class 3 Reserve Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 12.3.6.12 AVPML – VLAN Tag Priority Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 7 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 12.3.6.13 AVPMM – VLAN Priority Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 12.3.6.14 AVPMH – VLAN Priority Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 12.3.6.15 AVDM – VLAN Discard Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 12.3.6.16 TOSPML – TOS Priority Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 12.3.6.17 TOSPMM – TOS Priority Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 12.3.6.18 TOSPMH – TOS Priority Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 12.3.6.19 TOSDML – TOS Discard Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 12.3.6.20 USER_PROTOCOL_n – User Define Protocol 0~7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 12.3.6.21 USER_PROTOCOL_FORCE_DISCARD – User Define Protocol 0~7 Force Discard . . . . 89 User Defined Logical Ports and Well Known Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 12.3.6.22 WELL_KNOWN_PORT[1:0]_PRIORITY- Well Known Logic Port 1 and 0 Priority . . . . . . 90 12.3.6.23 WELL_KNOWN_PORT[3:2]_PRIORITY- Well Known Logic Port 3 and 2 Priority . . . . . . 90 12.3.6.24 WELL_KNOWN_PORT[5:4]_PRIORITY- Well Known Logic Port 5 and 4 Priority . . . . . . 90 12.3.6.25 WELL_KNOWN_PORT[7:6]_PRIORITY- Well Known Logic Port 7 and 6 Priority . . . . . . 90 12.3.6.26 WELL_KNOWN_PORT_ENABLE – Well Known Logic Port 0 to 7 Enables . . . . . . . . . . . 91 12.3.6.27 WELL_KNOWN_PORT_FORCE_DISCARD – Well Known Logic Port 0~7 Force Discard91 12.3.6.28 USER_PORT[7:0]_[LOwithHIGH] – User Define Logical Port 0~7 . . . . . . . . . . . . . . . . . . 92 12.3.6.29 USER_PORT_[1:0]_PRIORITY - User Define Logic Port 1 and 0 Priority . . . . . . . . . . . . . 92 12.3.6.30 USER_PORT_[3:2]_PRIORITY - User Define Logic Port 3 and 2 Priority . . . . . . . . . . . . . 92 12.3.6.31 USER_PORT_[5:4]_PRIORITY - User Define Logic Port 5 and 4 Priority . . . . . . . . . . . . . 92 12.3.6.32 USER_PORT_[7:6]_PRIORITY - User Define Logic Port 7 and 6 Priority . . . . . . . . . . . . . 93 12.3.6.33 USER_PORT_ENABLE[7:0] – User Define Logic Port 0 to 7 Enables . . . . . . . . . . . . . . . 93 12.3.6.34 USER_PORT_FORCE_DISCARD[7:0] – User Define Logic Port 0~7 Force Discard . . . . 93 12.3.6.35 RLOWL – User Define Range Low Bit 7:0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 12.3.6.36 RLOWH – User Define Range Low Bit 15:8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 12.3.6.37 RHIGHL – User Define Range High Bit 7:0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 12.3.6.38 RHIGHH – User Define Range High Bit 15:8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 12.3.6.39 RPRIORITY – User Define Range Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 12.3.7 (Group 6 Address) MISC Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 12.3.7.1 MII_OP0 – MII Register Option 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 12.3.7.2 MII_OP1 – MII Register Option 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 12.3.7.3 FEN – Feature Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 12.3.7.4 MIIC0 – MII Command Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 12.3.7.5 MIIC1 – MII Command Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 12.3.7.6 MIIC2 – MII Command Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 12.3.7.7 MIIC3 – MII Command Register 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 12.3.7.8 MIID0 – MII Data Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 12.3.7.9 MIID1 – MII Data Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 12.3.7.10 USD – One Micro Second Divider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 12.3.7.11 DEVICE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 12.3.7.12 CHECKSUM - EEPROM Checksum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 12.3.7.13 LHBTimer – Link Heart Beat Timeout Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 12.3.7.14 LHBReg0, LHBReg1 - Link Heart Beat OpCode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 12.3.7.15 fMACCReg0, fMACCReg1 - MAC Control Frame OpCode . . . . . . . . . . . . . . . . . . . . . . . . 99 12.3.7.16 FCB Base Address Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 12.3.7.17 FCB Base Address Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 12.3.7.18 FCB Base Address Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 12.3.8 (Group 7 Address) Port Mirroring Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 12.3.8.1 MIRROR CONTROL – Port Mirror Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 12.3.8.2 MIRROR_DEST_MAC[5:0] – Mirror Destination MAC Address 0~5 . . . . . . . . . . . . . . . . . 100 12.3.8.3 MIRROR_SRC _MAC[5:0] – Mirror Source MAC Address 0~5 . . . . . . . . . . . . . . . . . . . . . 100 12.3.8.4 RMAC_MIRROR0 – RMAC Mirror 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 8 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 12.3.8.5 RMAC_MIRROR1 – RMAC Mirror 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 12.3.9 (Group 8 Address) Per Port QOS Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 12.3.9.1 FCRn – Port 0~9 Flooding Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 12.3.9.2 BMRCn - Port 0~9 Broadcast/Multicast Rate Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 12.3.9.3 PR100_n – Port 0~7 Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.4 PR100_CPU – Port CPU Reservation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.5 PRM – Port MMAC Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.6 PTH100_n – Port 0~7 Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.7 PTH100_CPU – Port CPU Threshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.8 PTHG – Port MMAC Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.9 QOSC00, QOSC01 - Classes Byte Limit port 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 12.3.9.10 QOSC02, QOSC15 - Classes Byte Limit port 1-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 12.3.9.11 QOSC16 - QOSC21 - Classes Byte Limit CPU port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 12.3.9.12 QOSC22 - QOSC27 - Classes Byte Limit MMAC port . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 12.3.9.13 QOSC28 - QOSC31 - Classes WFQ Credit For MMAC. . . . . . . . . . . . . . . . . . . . . . . . . . 103 12.3.9.14 QOSC36 - QOSC39 - Shaper Control Port MMAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.3.10 (Group E Address) System Diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.3.10.1 DTSRL – Test Output Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.3.10.2 DTSRM – Test Output Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.3.10.3 TESTOUT0, TESTOUT1 – Testmux Output [7:0], [15:8] . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.3.10.4 MASK0-MASK4 – Timeout Reset Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 12.3.10.5 BOOTSTRAP0 – BOOTSTRAP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 12.3.10.6 PRTFSMST0~9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 12.3.10.7 PRTQOSST0-PRTQOSST7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 12.3.10.8 PRTQOSST8A, PRTQOSST8B (CPU port) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 12.3.10.9 PRTQOSST9A, PRTQOSST9B (MMAC port) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 12.3.10.10 CLASSQOSST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 12.3.10.11 PRTINTCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 12.3.10.12 QMCTRL0~9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 12.3.10.13 QCTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 12.3.10.14 BMBISTR0, BMBISTR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 12.3.10.15 BMControl. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 12.3.10.16 BUFF_RST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 12.3.10.17 FCB_HEAD_PTR0, FCB_HEAD_PTR1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 12.3.10.18 FCB_TAIL_PTR0, FCB_TAIL_PTR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 12.3.10.19 FCB_NUM0, FCB_NUM1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 12.3.10.20 BM_RLSFF_CTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 12.3.10.21 BM_RSLFF_INFO[5:0] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 12.3.11 (Group F Address) CPU Access Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 12.3.11.1 GCR - Global Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 12.3.11.2 DCR - Device Status and Signature Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 12.3.11.3 DCR1 - Device Status Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 12.3.11.4 DPST – Device Port Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 12.3.11.5 DTST – Data read back register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 12.3.11.6 DA – Dead or Alive Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 13.0 Characteristics and Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 13.1 Absolute Maximum Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 13.2 DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 13.3 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 13.4 AC Characteristics and Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 13.4.1 Typical Reset & Bootstrap Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 13.4.2 Reduced Media Independent Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 9 Zarlink Semiconductor Inc. ZL50410 Data Sheet Table of Contents 13.4.3 Media Independent Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 13.4.4 General Purpose Serial Interface (7-wire) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 13.4.5 MDIO Input Setup and Hold Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 13.4.6 I²C Input Setup Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 13.4.7 Serial Interface Setup Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 13.4.8 JTAG (IEEE 1149.1-2001) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 14.0 Document History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 14.1 July 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 14.2 November 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 14.3 February 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 14.4 August 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 14.5 November 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 10 Zarlink Semiconductor Inc. ZL50410 1.0 BGA and Ball Signal Descriptions 1.1 BGA Views (Top-View) 1 Data Sheet 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A SCLK P_CS# P_RD# P_WE # P_DAT A1 P_DAT A3 P_DAT A5 P_DAT A7 P_DAT A9 P_DAT A11 P_DAT A13 P_DAT A15 GREF_ CLK M9_TX CLK M9_M TXCLK M9_TX EN A B P_INT # P_A0 P_A1 P_A2 P_DAT A0 P_DAT A2 P_DAT A4 P_DAT A6 P_DAT A8 P_DAT A10 P_DAT A12 P_DAT A14 TCK TMS M9_TX ER M9_RX CK B C RESET OUT# TSTO UT1 TSTO UT3 TSTO UT5 TSTO UT6 TSTO UT7 TSTO UT9 TSTO UT11 TSTO UT12 TSTO UT14 TSTO UT15 TRST# TDI M9_RX D7 M9_C RS M9_C OL C D RESIN # TSTO UT0 TSTO UT2 TSTO UT4 3.3V SCAN_ EN TSTO UT8 TSTO UT10 1.8V TSTO UT13 TDO 3.3V M9_RX D5 M9_RX D6 M9_RX DV M9_RX ER D E M2_C OL M0_C OL M1_C OL 3.3V 3.3V M9_RX D4 M9_TX D6 M9_TX D7 E F M_MD C M_MDI O M0_RX D2 M0_RX D3 M9_RX D2 M9_RX D3 M9_TX D4 M9_TX D5 F G M0_RX D0 M0_RX D1 M0_RX CK M0_TX D3 GND GND GND GND M9_RX D0 M9_RX D1 M9_TX D2 M9_TX D3 G H M0_C RS M0_TX EN M0_TX D2 1.8V GND GND GND GND 1.8V M7_C OL M9_TX D0 M9_TX D1 H J M0_TX D0 M0_TX D1 M0_TX CK M1_RX D3 GND GND GND GND M7_TX D3 M7_TX CK M7_TX D1 M7_TX D0 J K M1_RX D0 M1_RX D1 M1_RX D2 M1_RX CK GND GND GND GND M7_TX D2 M7_RX D2 M7_TX EN M7_C RS K L M1_C RS M1_TX EN M1_TX D2 M1_TX D3 M7_RX D3 M7_RX CK M7_RX D1 M7_RX D0 L M M1_TX D0 M1_TX D1 M1_TX CK 3.3V 3.3V M6_C OL M5_C OL M4_C OL M N M2_RX D3 M2_TX CK M2_TX D3 M3_RX D3 3.3V M3_TX D3 1.8V M4_RX D3 M4_TX CK M4_TX D3 M5_RX D3 M5_TX CK M5_TX D3 M6_RX D3 M6_TX CK M6_TX D3 N P M2_RX D2 M2_RX CK M2_TX D2 M3_RX D2 M3_RX CK M3_TX D2 M3_C OL M4_RX D2 M4_RX CK M4_TX D2 M5_RX D2 M5_RX CK M5_TX D2 M6_RX D2 M6_RX CK M6_TX D2 P R M2_RX D1 M2_TX EN M2_TX D1 M3_RX D1 M3_TX EN M3_TX D1 M_CLK M4_RX D1 M4_TX EN M4_TX D1 M5_RX D1 M5_TX EN M5_TX D1 M6_RX D1 M6_TX EN M6_TX D1 R T M2_RX D0 M2_C RS M2_TX D0 M3_RX D0 M3_C RS M3_TX D0 M3_TX CK M4_RX D0 M4_C RS M4_TX D0 M5_RX D0 M5_C RS M5_TX D0 M6_RX D0 M6_C RS M6_TX D0 T 3 4 6 7 8 10 11 13 14 1 1.2 2 5 9 12 Power and Ground Distribution G7-10, H7-10, J7-10, K7-10 GND VSS Ground D5, D12, E4, E13, M4, M13, N5 3.3V VCC I/O Power D9, H4, H13, N7 1.8V VDD Core Power 11 Zarlink Semiconductor Inc. 15 16 ZL50410 1.3 Data Sheet Ball Signal Descriptions All pins are CMOS type; all Input Pins are 5 Volt tolerance; and all Output Pins are 3.3 CMOS drive. Notes #= Active low signal Input = Input signal Input-ST = Input signal with Schmitt-Trigger Output = Output signal (Tri-State driver) I/O-TS = Input & Output signal with Tri-State driver pull-up = Weak internal pull-up (nominal 100K ohm) (refer to Section 1.4 on page 17 as some internal pull-ups are not enabled in certain configurations) pull-down = Weak internal pull-down (nominal 100K ohm) (refer to Section 1.4 on page 17 as some internal pull-downs are not enabled in certain configurations) Ball Signal Description Table Ball No(s) Symbol I/O Description 16-Bit CPU Bus Interface A12, B12, A11, B11, A10, B10, A9, B9, A8, B8, A7, B7, A6, B6, A5, B5 P_DATA[15:0] I/O-TS with pull-up Processor Bus Data Bit [15:0]. P_DATA[7:0] is used in 8-bit mode. B4, B3, B2 P_A[2:0] Input with pull-up Processor Bus Address Bit [2:0] A4 P_WE# Input with pull-up CPU Bus-Write Enable A3 P_RD# Input CPU Bus-Read Enable A2 P_CS# Input with pull-up Chip Select B1 P_INT# Output CPU Interrupt Fast Ethernet Access Ports [7:0] MII L13, K14, L15, L16, N14, P14, R14, T14, N11, P11, R11, T11, N8, P8, R8, T8, N4, P4, R4, T4, N1, P1, R1, T1, J4, K3, K2, K1, F4, F3, G2, G1 M[7:0]_RXD[3:0] Input with pull-up Ports [7:0] – Receive Data Bit [3:0] K16, T15, T12, T9, T5, T2, L1, H1 M[7:0]_CRS_DV Input with pull-up Ports [7:0] – Carrier Sense and Receive Data Valid 12 Zarlink Semiconductor Inc. ZL50410 Data Sheet Ball Signal Description Table (continued) Ball No(s) K15, R15, R12, R9, R5, R2, L2, H2 Symbol M[7:0]_TXEN I/O Description Output, slew Ports [7:0] – Transmit Enable This pin also serves as a bootstrap pin. J13, K13, J15, J16, N16, P16, R16, T16, N13, P13, R13, T13, N10, P10, R10, T10, N6, P6, R6, T6, N3, P3, R3, T3, L4, L3, M2, M1, G4, H3, J2, J1 M[7:0]_TXD[3:0] Output, slew Ports [7:0] – Transmit Data Bit [3:0] H14, M14, M15, M16, P7, E1, E3, E2 M[7:0]_COL Input with pull-down Ports[7:0] – Collision J14, N15, N12, N9, T7, N2, M3, J3 M[7:0]_TXCLK Input or Output with pull-up Ports[7:0] – Transmit Clock This pin in an output if ECR4Pn[0]='1' L14, P15, P12, P9, P5, P2, K4, G3 M[7:0]_RXCLK Input or Output with pull-up Ports[7:0] – Receive Clock This pin in an output if ECR4Pn[1]='1' Gigabit Ethernet Uplink Port GMII E16, E15, F16, F15, G16, G15, H16, H15 M9_TXD[7:0] Output Transmit Data Bit [7:0] D15 M9_RXDV Input with pull-up Receive Data Valid D16 M9_RXER Input with pull-up Receive Error C15 M9_CRS Input with pull-down Carrier Sense C16 M9_COL Input with pull-down Collision Detected B16 M9_RXCLK Input or Output with pull-up Receive Clock In MII mode, this pin in an output if ECR4P9[1]='1' C14, D14, D13, E14, F14, F13, G14, G13 M9_RXD[7:0] Input with pull-up Receive Data Bit [7:0] A16 M9_TXEN Output with pull-up Transmit Data Enable This pin also serves as a bootstrap pin. B15 M9_TXER Output with pull-up Transmit Error This pin also serves as a bootstrap pin. 13 Zarlink Semiconductor Inc. ZL50410 Data Sheet Ball Signal Description Table (continued) Ball No(s) Symbol I/O Description A15 M9_MTXCLK Input with pull-up Transmit Clock A14 M9_TXCLK Output Gigabit Transmit Clock TSTOUT[15:0] Output [15:4] Reserved [3] EEPROM checksum is good [2] Initialization Completed [1] Memory Self Test in progress [0] Initialization started Test Interface C11, C10, D10, C9, C8, D8, C7, D7, C6, C5, C4, D4, C3, D3, C2, D2 These pins also serve as bootstrap pins. Test Facility C13 TDI Input with pull-up JTAG - Test Data In C12 TRST# Input with pull-up JTAG - Test Reset B13 TCK Input with pull-up JTAG - Test Clock B14 TMS Input with pull-up JTAG - Test Mode State D11 TDO Output JTAG - Test Data Out D6 SCAN_EN Input Scan Enable. Manufacturing test option. Must be externally pulled-down Should be externally pulled-down for proper operation. System Clock, Power, and Ground Pins A1 SCLK Input System Clock. Based on system requirement, SCLK needs to operate at difference frequency. SCLK requires 40/60% duty cycle clock. D9, H4, H13, N7, VDD Power +1.8 Volt DC Supply D5, D12, E4, E13, M4, M13, N5, VCC Power +3.3 Volt DC Supply G7-10, H7-10, J7-10, K7-10 VSS Power Ground Ground D1 RESIN# Input Reset Input C1 RESETOUT# Output Reset PHY Misc. 14 Zarlink Semiconductor Inc. ZL50410 Data Sheet Ball Signal Description Table (continued) Ball No(s) Symbol I/O Description F1 M_MDC Output MII Management Data Clock F2 M_MDIO I/O-TS with pull-up MII Management Data I/O R7 M_CLK Input RMAC Reference Clock A13 GREF_CLK Input with pull-up GMAC Reference Clock Bootstrap Pins (1= pull-up 0= pull-down)1 (See “Bootstrap Options” on page 20) D2 TSTOUT[0] Input (Reset Only) Enable Debounce of STROBE signal Pullup – Enabled Pulldown - Disabled C3, D3, C2 TSTOUT[3:1] Input (Reset Only) Management interface operation mode: 000 – 16-bit parallel interface 001 – 8-bit parallel interface 010 – Serial with MII as Ethernet frame transfer interface. 011 – Serial only. CPU can transmit/receive frames with the serial interface. 111 – Unmanaged Serial. No CPU packet can be transmit or received with the serial interface. EEPROM can be used to configure the device at bootup. A one (1) indicates pullup. A zero (0) indicates pulldown. TSTOUT[1] is the Least Significant Bit (LSB). C5, C4, D4 TSTOUT[6:4] Input (Reset Only) Device ID. Default address of the device for serial interface. Up to 8 device can be sharing the serial management bus with different device ID. A one (1) indicates pullup. A zero (0) indicates pulldown. TSTOUT[4] is the Least Significant Bit (LSB). C6 TSTOUT[7] Input (Reset Only) EEPROM not installed. Pullup: Not installed Pulldown: Installed D7 TSTOUT[8] Input (Reset Only) Manufacturing Option. Must be pulled up. Must be externally pulled-up 15 Zarlink Semiconductor Inc. ZL50410 Data Sheet Ball Signal Description Table (continued) Ball No(s) Symbol I/O Description C7 TSTOUT[9] Input (Reset Only) Module Detect Pullup: Enable. In this mode, the device will detect the existence of a PHY (for hot swap purpose). Pulldown: Disable D8 TSTOUT[10] Input (Reset Only) Manufacturing Option. Must be pulled down. Must be externally pulled-down C8 TSTOUT[11] Input (Reset Only) Power Saving Pullup: Enable MAC power saving mode Pulldown: Disable MAC power saving mode C9 TSTOUT[12] Input (Reset Only) Timeout Reset Enable Pullup: Enable Pulldown: Disable C11, C10, D10 TSTOUT[15:13] Input (Reset Only) Manufacturing Options. Must be pulled-up. Must be externally pulled-up K15, R15, R12, R9, R5, R2, L2, H2 M[7:0]_TXEN Input (Reset Only) User Defined Bootstrap: Usually used in conjuction with Module Detect to determine what interface to use for the inserted module. Can be read from BOOTSTRAP2 register A16, B15 M9_TXEN, M9_TXER Input with pull-up (Reset Only) User Defined Bootstrap: Usually used in conjuction with Module Detect to determine what interface to use for the inserted module. Can be read from BOOTSTRAP3 register 1. External pull-up/down resistors are required on all bootstrap pins for proper operation. Recommend 10K for pull-ups and 1K for pull-downs. 16 Zarlink Semiconductor Inc. ZL50410 1.4 Data Sheet Signal Mapping and Internal pull-up/Down Configuration The ZL50410 Fast Ethernet access ports (0-7) support 3 interface options: RMII, MII & GPSI. The table below summarizes the interface signals required for each interface and how they relate back to the Pin Symbol name shown in the “Ball Signal Description Table” on page 12. It also specifies whether the internal pull-up/down resistor is present for each pin in the specific operating mode. Notes: I – Input O – Output U – Pullup D - Pulldown Fast Ethernet Access Ports Pin Symbol No Module (Bootstrap TSTOUT9=’1’) RMII Mode MII Mode GPSI Mode (ECR4Pn[4:3]='11') (ECR4Pn[4:3]='01') (ECR4Pn[4:3]='00') M[7:0]_RXD0 (U) M[7:0]_RXD0 (I) M[7:0]_RXD0 (I) M[7:0]_RXD (I) M[7:0]_RXD1 (U) M[7:0]_RXD1 (I) M[7:0]_RXD1 (I) NC (U) M[7:0]_RXD2 (U) NC (U) M[7:0]_RXD2 (I) NC (U) M[7:0]_RXD3 (U) NC (U) M[7:0]_RXD3 (I) NC (U) M[7:0]_TXEN (O) M[7:0]_TXEN (O) M[7:0]_TXEN (O) M[7:0]_TXEN (O) M[7:0]_CRS_DV (U) M[7:0]_CRS_DV (I) M[7:0]_DV (I) M[7:0]_CRS (I) M[7:0]_TXD0 (O) M[7:0]_TXD0 (O) M[7:0]_TXD0 (O) M[7:0]_TXD (O) M[7:0]_TXD1 (O) M[7:0]_TXD1 (O) M[7:0]_TXD1 (O) NC (O) M[7:0]_TXD2 (O) NC (O) M[7:0]_TXD2 (O) NC (O) M[7:0]_TXD3 (O) NC (O) M[7:0]_TXD3 (O) NC (O) M[7:0]_COL (D) NC (D) M[7:0]_COL (I) M[7:0]_COL (I) M[7:0]_TXCLK (U) NC (U) M[7:0]_TXCLK (IO) M[7:0]_TXCLK (IO) M[7:0]_RXCLK (U) NC (U) M[7:0]_RXCLK (IO) M[7:0]_RXCLK (IO) Table 1 - Signal Mapping In Different Operation Mode 17 Zarlink Semiconductor Inc. ZL50410 Data Sheet The ZL50410 Gigabit Ethernet uplink port (port 9) supports 2 interface options: GMII & MII. The table below summarizes the interface signals required for each interface, and how they relate back to the Pin Symbol name shown in “Ball Signal Description Table” on page 12. Gigabit Ethernet Uplink Port Pin Symbol No Module (Bootstrap TSTOUT9=’1’) GMII Mode MII Mode (ECR4P9[4:3]='11') (ECR4P9[4:3]='00') M9_RXD0 (U) M9_RXD0 (I) M9_RXD0 (I) M9_RXD1 (U) M9_RXD1 (I) M9_RXD1 (I) M9_RXD2 (U) M9_RXD2 (I) M9_RXD2 (I) M9_RXD3 (U) M9_RXD3 (I) M9_RXD3 (I) M9_RXD4 (U) M9_RXD4 (I) NC (U) M9_RXD5 (U) M9_RXD5 (I) NC (U) M9_RXD6 (U) M9_RXD6 (I) NC (U) M9_RXD7 (U) M9_RXD7 (I) NC (U) M9_RXDV (U) M9_RXDV (I) M9_RXDV (I) M9_RXER (U) M9_RXER (I) NC (U) M9_CRS (D) M9_CRS (I) M9_CRS (I) M9_COL (D) M9_COL (I) M9_COL (I) M9_RXCLK (U) M9_RXCLK (I) M9_RXCLK (IO) M9_TXD0 (O) M9_TXD0 (O) M9_TXD0 (O) M9_TXD1 (O) M9_TXD1 (O) M9_TXD1 (O) M9_TXD2 (O) M9_TXD2 (O) M9_TXD2 (O) M9_TXD3 (O) M9_TXD3 (O) M9_TXD3 (O) M9_TXD4 (O) M9_TXD4 (O) NC (O) M9_TXD5 (O) M9_TXD5 (O) NC (O) M9_TXD6 (O) M9_TXD6 (O) NC (O) M9_TXD7 (O) M9_TXD7 (O) NC (O) M9_TXEN (U) M9_TXEN (O) M9_TXEN (O) M9_TXER (U) M9_TXER (O) NC (O) M9_TXCLK (O) M9_TXCLK (O) NC (O) GREF_CLK (U) GREF_CLK (I) REF_CLK (I) M9_MTXCLK (U) M9_MTXCLK (I) M9_MTXCLK (I) Table 2 - Signal Mapping In Different Operation Mode 18 Zarlink Semiconductor Inc. ZL50410 Data Sheet The ZL50410 CPU access support 5 interface options: 8 or 16-bit parallel, serial+MII (port 8), serial only, and unmanaged serial (with optional EEPROM). The table below summarizes the interface signals required for each interface, and how they relate back to the Pin Symbol name shown in “Ball Signal Description Table” on page 12. Management Interface Pin Symbol 16-bit CPU 8-bit CPU Serial with MII Serial Only (TSTOUT[3:1]=’000’) (TSTOUT[3:1]=’001’) (TSTOUT[3:1]=’010’) (TSTOUT[3:1]=’011’ or ‘111’) P_A[0] P_A[0] (I) P_A[0] (I) NC (U) SDA (IOU) (111 only) P_A[1] P_A[1] (I) P_A[1] (I) NC (U) SCL (OU) (111 only) P_A[2] P_A[2] (I) P_A[2] (I) NC (U) NC (U) P_WE# P_WE# (I) P_WE# (I) STROBE (IU) STROBE (IU) P_RD# P_RD# (I) P_RD# (I) DATAOUT (O) DATAOUT (O) P_CS# P_CS# (I) P_CS# (I) DATAIN (IU) DATAIN (IU) P_INT# P_INT# (O) P_INT# (O) P_INT# (O) P_INT# (O) P_DATA0 P_DATA0 (IOU) P_DATA0 (IOU) CPU_MII_TXD0 (O) NC (U) P_DATA1 P_DATA1 (IOU) P_DATA1 (IOU) CPU_MII_TXD1 (O) NC (U) P_DATA2 P_DATA2 (IOU) P_DATA2 (IOU) CPU_MII_TXD2 (O) NC (U) P_DATA3 P_DATA3 (IOU) P_DATA3 (IOU) CPU_MII_TXD3 (O) NC (U) P_DATA4 P_DATA4 (IOU) P_DATA4 (IOU) CPU_MII_TXCLK (O) NC (U) P_DATA5 P_DATA5 (IOU) P_DATA5 (IOU) CPU_MII_TXEN (O) NC (U) P_DATA6 P_DATA6 (IOU) P_DATA6 (IOU) NC (U) NC (U) P_DATA7 P_DATA7 (IOU) P_DATA7 (IOU) NC (U) NC (U) P_DATA8 P_DATA8 (IOU) NC (U) CPU_MII_RXD0 (I) NC (U) P_DATA9 P_DATA9 (IOU) NC (U) CPU_MII_RXD1 (I) NC (U) P_DATA10 P_DATA10 (IOU) NC (U) CPU_MII_RXD2 (I) NC (U) P_DATA11 P_DATA11 (IOU) NC (U) CPU_MII_RXD3 (I) NC (U) P_DATA12 P_DATA12 (IOU) NC (U) CPU_MII_RXCLK (O) NC (U) P_DATA13 P_DATA13 (IOU) NC (U) CPU_MII_RXDV (I) NC (U) P_DATA14 P_DATA14 (IOU) NC (U) NC (U) NC (U) P_DATA15 P_DATA15 (IOU) NC (U) NC (U) NC (U) Table 3 - Signal Mapping In Different Operation Mode 19 Zarlink Semiconductor Inc. ZL50410 1.5 Data Sheet Bootstrap Options TSTOUT[15:0], M[7:0]_TXEN, M9_TXEN and M9_TXER pins serve as bootstrap pins during device power-up or reset. Please refer to “Typical Reset & Bootstrap Timing Diagram” on page 124 for more information on when the bootstrap pins are sampled. The bootstrap pins require external pull-up/down resistors for proper operation. The table below summarizes the bootstrap options. Feature CPU Interface Description The ZL50410 allows the selection of 5 different management interfaces: 8/16-bit parallel, serial with MII, serial only and unmanaged serial with I2C EEPROM. TSTOUT[3:1] is used to select the interface options mentioned above. If the serial interface is selected, addition bootstrap options are required: • TSTOUT[0] enables or disables the DEBOUNCE feature (refer to “Synchronous Serial Interface” on page 32) • TSTOUT[6:4] selects the device ID Also, in unmanaged mode, an optional I2C EEPROM can be used to configure the device at power-up or reset. TSTOUT[7] selects the EEPROM option. Ethernet Interface The ZL50410 supports module hotswap on all it's ports. This is enabled via TSTOUT[9]. When enabled, bootstrap pins M[7:0]_TXEN (ports 0-7) and M9-TXEN & M9_TXER (port 9) are used to specify the module type to support multiple ethernet interfaces during module hotswap. Another feature is the MAC power savings mode. When enabled via TSTOUT[11], each port's MAC will detect inactivity on the port and go into a power savings state. When activity is detected once again on the port, the MAC will come out of this state. Misc. Features One other feature selected via bootstrap is Timeout Reset Enable (TSTOUT[12]). This enables a monitoring block with the device which will detect if any hardware state machine is in a non-idle state for more than 5 seconds. Refer to section 2.7 for more details on this feature. Table 4 - Bootstrap Features 1.5.1 Recommended Default Bootstrap Settings The following are the recommended default settings for the bootstrap options: • Unmanaged/Lightly Managed • Reserved/Manufacturing bootstraps - TSTOUT[15:13,8] must be pulled-up - TSTOUT[10] must be pulled-down • CPU Interface: - Strobe debounce bootstrap, TSTOUT[0], should be normally pulled-up, unless you wish to disable the debounce logic - CPU Interface bootstrap, TSTOUT[3:1], should be pulled-up to indicate unmanaged SSI CPU interface. To enable SSI-only lightly managed mode, pulled-down TSTOUT[3]. To enable SSI+MII lightly managed mode, pulled-down TSTOUT[3,1] 20 Zarlink Semiconductor Inc. ZL50410 Data Sheet - • SSI Device ID bootstrap, TSTOUT[6:4], should be pulled-down to indicate device ID 0x0 for the SSI interface. Can be changed to whatever device ID required if more than one device on the SSI bus. - EEPROM bootstrap, TSTOUT[7], should be pulled-up to disable until the system is debugged. You can pull-down this bootstrap if using the optional EEPROM in unmanaged mode (NOTE: this bootstrap is not valid in any other CPU mode) • Module Detect bootstrap, TSTOUT[9], should be pulled-down - In lightly managed mode, you can enable the optional Module Detect feature - If enabled, need to use Mn_TXEN to indicate module type • Power Saving bootstrap, TSTOUT[11], should be normally pulled-up • Timeout Reset bootstrap, TSTOUT[12], should be pull-down - Once system is debugged, you can enable the optional feature with pull-up (Refer to section 2.7 for more details on this feature) Managed • Reserved/Manufacturing bootstraps - TSTOUT[15:13,6:4,8,7,0] must be pulled-up - TSTOUT[10] must be pulled-down • CPU Interface - TSTOUT[3:1], should be pulled-down to indicate 16-bit CPU mode - For 8-bit CPU mode, pull-up TSTOUT[1] • Module Detect bootstrap, TSTOUT[9], should be pulled-down, unless using the Module Detect feature - If enabled, need to use Mn_TXEN to indicate module type • Power Saving bootstrap, TSTOUT[11], should be normally pulled-up • Timeout Reset bootstrap, TSTOUT[12], should be pull-down - Once system is debugged, you can enable the optional feature with pull-up (Refer to section 2.7 for more details on this feature) 1.6 Default Switch Configuration and Initialization Sequence The ZL50410 will come out of reset in a default configuration, which will allow for basic L2 switching and automatic MAC address learning. In unmanaged mode, the default configuration will take effect immediately after reset. The default settings can be changed using the optional EEPROM. • • System Defaults • Port-based VLAN • MAC address 00-00-00-00-00-00 not learned • Drop MAC addresses 01-80-C2-00-00-01~F • No IP Multicast switching support • Trunking and mirroring disabled • MAC address agetime is 300 seconds • VLAN 802.1p prioritization - All priority bits mapped to priority 0 (lowest) • 96 queued unicast/multicast frames will trigger flow control • All WRED drop percentages equal to 0% • Unicast/multicast/broadcast flood control disabled • No shared or per-class buffer pools Per-port Defaults • Disable per-port fixed priority and drop precedence • Disable asynchronous flow control • Spanning Tree per-port state equal to forwarding • Don’t filter tagged/untagged VLAN frames 21 Zarlink Semiconductor Inc. ZL50410 • • • • • • • • Data Sheet Automatic learning enabled Per-port security disabled Support frame size 64 <= n <= 1522 Pad transmit frames < 64B Standard preamble Strict Priority scheduling FE Ports - RMII mode - Auto-negotiate 100M/Full Duplex/Flow Control - Rate control disabled - per-source port buffer pool of 96 buffers, with flow control threshold of 48 buffers Uplink Port - GMII mode - Auto-negotiate 1000M/Full Duplex/Flow Control - per-source port buffer pool of 384 buffers, with flow control threshold of 192 buffers In lightly managed/managed mode, the default configuration can be used as well, however, the device needs to be told when to start switching. This is done via the “Init Complete” bit, set in GCR[4]. The default settings can be overridden using the CPU interface, but should be done before setting of GCR[4]. One thing to note is after reset, the device will start to initialize the control tables. Therefore, a short delay (100us~1ms) is necessary before changing the register settings and/or control tables, and before setting GCR[4]. • • System Defaults • CPU MAC address is 00-00-00-00-00-00 • Forward MAC addresses 01-80-C2-00-00-00~FF to CPU port - Except 01-80-C2-00-00-01~F, which are dropped • All interrupts enabled • MAC address learn report to CPU disabled • Statistics counters disabled • DiffServ EF code support disabled • No VLAN ID hashing Per-port Defaults • FE Ports - Link heart beat disabled • CPU Port - 100M/Full Duplex/Flow Control - 8-byte header padding - per-source port buffer pool of 96 buffers, with flow control threshold of 48 buffers 22 Zarlink Semiconductor Inc. ZL50410 2.0 Data Sheet Block Functionality RMAC X 8 G GMAC Frame Engine Search Engine Other Internal Memory Block Management Module Internal Memory Figure 2 - Functional Block Diagram 2.1 Internal Memory Two Megabit of internal memory is provided for ethernet Frame Data Buffering (FDB), storing of MAC Control Table database (MCT), and the Network Management (NM) Database statistics counters and MIB. The MCT is used for storing MAC addresses and their physical port number. The FDB is used for storing the received frame data contents. The contents are stored in this memory until it is ready to be transmitted to the egress port. A memory arbiter is used to arbitrary the memory access requests from various sources. A Built In Self Test (BIST) is used to detect any error in the memory array when the device is powered up. The BIST can also be requested by the writing to the GCR register. 2.2 2.2.1 MAC Modules RMII MAC Module (RMAC) The RMII Media Access Control (RMAC) module provides the necessary buffers and control interface between the Frame Engine (FE) and the external physical device (PHY). It has five interfaces: MII, RMII, GPSI (only for 10M), Reverse MII, or Reverse GPSI (only for 10M). The RMAC of the ZL50410 device meets the IEEE 802.3 specification. It is able to operate in either Half or Full Duplex mode with a back pressure/flow control mechanism. In addition, it will automatically retransmit upon collision for up to 16 total transmissions. These eight ports are denoted as ports 0 to 7. The PHY addresses for the PHY devices connected to the 8 RMAC ports has to be from 08h (port 0) to 0Fh (port 7). 23 Zarlink Semiconductor Inc. ZL50410 2.2.1.1 Data Sheet GPSI (7WS) Interface The RMAC ethernet port can function in GPSI (7WS) mode. In this mode, the TXD[0], RXD[0] serve as TX data, RX data and respectively. The link and duplex of the port can be controlled by programming the ECR1Pn register. Only port-based VLAN is supported with GPSI interface. 2.2.2 CPU MAC Module (CMAC) The CPU Media Access Control (CMAC) module provides the necessary buffers and control interface between the Frame Engine (FE) and the external CPU device. It support either a Reverse MII interface, providing the necessary interface TX and RX clocks to the CPU, or a register access mechanism via the 8/16-bit or serial interface. Using the MII interface, the CMAC of the ZL50410 device meets the IEEE 802.3 specification. It is able to operate in either Half or Full Duplex mode with a back pressure/flow control mechanism. In addition, it will automatically retransmit upon collision for up to 16 total transmissions. This port is denoted as port 8. 2.2.3 GMII MAC Module (GMAC) The GMII Media Access Control (GMAC) module provides the necessary buffers and control interface between the Frame Engine (FE) and the external physical device (PHY). The GMAC implements both GMII and MII interface, which offers a simple migration from 10/100 to 1G. The GMAC of the ZL50410 device meets the IEEE 802.3Z specification. It is able to operate in 10M/100M either Half or Full Duplex mode with a back pressure/flow control mechanism or in 1G Full duplex mode with flow control mechanism. Furthermore, it will automatically retransmit upon collision for up to 16 total transmissions. This port is denoted as port 9. The PHY address for the PHY device connected to the GMAC port has to be 10h. 2.2.4 PHY Addresses The table below provides an overview of the PHY addresses required for each port in order for the MDIO auto-negotiation to work between the ZL50410 MAC and the PHY device. If a different PHY address is used, then the port must be manually brought up and the PHY will need to be polled for link status via the MIIC/D registers. MAC Port PHY Address RMAC Port 0 0x08 RMAC Port 1 0x09 ... ... RMAC Port 7 0x0F CMAC Port 8 NA GMAC Port 9 0x10 Table 5 - PHY Addresses 2.3 Management Module The CPU can send a control frame to access or configure the internal network management database. The Management Module decodes the control frame and executes the functions requested by the CPU. This module is only active in managed mode. In unmanaged mode, no control frame is accepted by the device. 24 Zarlink Semiconductor Inc. ZL50410 2.4 Data Sheet Frame Engine The main function of the frame engine is to forward a frame to its proper destination port or ports. When a frame arrives, the frame engine parses the frame header (64 bytes) and formulates a switching request, sent to the search engine, to resolve the destination port. The arriving frame is moved to the internal memory. After receiving a switch response from the search engine, the frame engine performs transmission scheduling based on the frame’s priority. The frame engine forwards the frame to the MAC module when the frame is ready to be sent. 2.5 Search Engine The Search Engine resolves the frame’s destination port or ports according to the destination MAC address (L2) or IP multicast address (IP multicast packet) by searching the database. It also performs MAC learning, priority assignment, and trunking functions. 2.6 Heartbeat Packet Generation and Response The ZL50410 provides the ability to monitor a link and detect a simple link failure. The Link Heart Beat (LHB) packet generation module allows simultaneous tracking of all the RMAC ports. Periodically, a LHB message will be sent for each link when inactivity is detected with in a programmable time period, If a reply is not received in a specified amount of time, the failover detection module will identify a point-to-point failure for that link. The failover detection module will then interrupt the CPU. The LHB packet response module can also reply to LHB messages initiated by other ZL50410 devices in the system, or by non-ZL50410 devices which use a conventional and recognizable LHB message format. 2.7 Timeout Reset Monitor The ZL50410 supports a state machine monitoring block which can trigger a reset or interrupt if any state machine is determined to be stuck in a non-idle state for more than 5 seconds. This feature is enabled via a bootstrap pin (TSTOUT12). It also requires some register configuration via the CPU interface. See Programming Timeout Reset application note, ZLAN-41, for more information. 2.8 JTAG An IEEE1149.1 compliant test interface is provided for boundary scan. 25 Zarlink Semiconductor Inc. ZL50410 3.0 Data Sheet Management and Configuration One extra port is dedicated to the CPU via the CPU interface module. Three modes this port can operate: managed, lightly managed or unmanaged mode. The different between these modes is tx/rx Ethernet frame, tx/rx control frame and receiving interrupt due to the lack of constant attention or processing power from the CPU. The CPU interface utilizes a 8/16-bit bus in managed mode. It also supports a serial+MII, serial only, and an I2C interface, which provides an easy and lower cost way to configure the system for reduced management. Supported CPU interface modes are Operation Mode ISA Interface Serial MII I²C 16-bit CPU 16-bit NA NA NA 8-bit CPU 8-bit NA NA NA Serial with MII interface NA Yes Yes No Lightly Managed Serial NA Yes No No Unmanaged Serial NA Yes No Yes Table 6 - Supported CPU interface modes 1. 16-bit CPU interface similar to the Industry Standard Architecture (ISA) specification. 2. 8-bit CPU interface similar to ISA. 3. Serial with MII. A synchronous serial interface (SSI) bus is used for accessing the configuration register and control frame. MII is used for sending and receiving CPU packets. 4. Lightly Managed Serial. Configuration registers access, Control frame and CPU transmit/receive packets are sent through a synchronous serial interface (SSI) bus. 5. Unmanaged Serial. The device can be configured by EEPROM using an I²C interface at bootup, or via a synchronous serial interface (SSI) otherwise. All configuration registers and internal control blocks are accessible by the interface. However, the CPU cannot receive or transmit frames nor will it receive any interrupt information. The CPU interface provides for easy and effective management of the switching system. Figure 3 on page 27 provides an overview of the 8/16-bit interface. Figure 4 on page 28 provides an overview of the SSI interface. Figure 5 on page 29 provides an overview of the SSI+MII interface. 26 Zarlink Semiconductor Inc. ZL50410 Data Sheet Processor Index Reg 0 (Addr = 0) Config Data Reg (Addr = 2) P_INT# Index Reg 1 (Addr = 1) P_CS# Address P_RD# 8/16-bit Data Bus P_WE# 3-bit Address Bus I/O Data MUX Command/ Status Reg (Addr = 4) CPU Frame Reg (Addr = 3) Interrupt Reg (Addr = 5) Control Command 1 Reg (Addr = 6) Control Command 2 Reg (Addr = 7) 8/16-bit Data Bus 16-bit Address 8-bit Data Bus Internal Registers Inderect Access 8/16-bit Data Bus Control Control Command 1 Command 1Transmit Receive FIFO FIFO CPU frame Transmit CPU frame Receive FIFO FIFO Interrupt Figure 3 - Overview of the 8/16-bit Interface 27 Zarlink Semiconductor Inc. Control Command 2 Transmit FIFO ZL50410 Data Sheet Processor Serial Out Serial In Strobe Interrupt Synchronous Serial Interface 3-bit Address Bus 16-bit Data Bus Address Index Reg 1 (Addr = 1) Index Reg 0 (Addr = 0) Config Data Reg (Addr = 2) INT CS W R I/O Data MUX Command/ Status Reg (Addr = 4) CPU Frame Reg (Addr = 3) Interrupt Reg (Addr = 5) Control Command 1 Reg (Addr = 6) Control Command 2 Reg (Addr = 7) 8/16-bit Data Bus 16-bit Address 8-bit Data Bus Internal Registers Inderect Access 8/16-bit Data Bus Control Control Command 1 Command 1Transmit Receive FIFO FIFO CPU frame Transmit CPU frame Receive FIFO FIFO Interrupt Figure 4 - Overview of the SSI Interface 28 Zarlink Semiconductor Inc. Control Command 2 Transmit FIFO ZL50410 Data Sheet Processor Tclk Txd Txen Rxd Rxdv Rclk Serial Out MII Interface Serial In Strobe Synchronous Serial Interface 3-bit Address Bus 16-bit Data Bus Address Index Reg 1 (Addr = 1) 8/16-bit Data Bus Interrupt Index Reg 0 (Addr = 0) 16-bit Address CPU frame Transmit CPU frame Receive FIFO FIFO INT CS W R I/O Data MUX Config Data Reg (Addr = 2) Command/ Status Reg (Addr = 4) Interrupt Reg (Addr = 5) 8-bit Data Bus Control Command 1 Reg (Addr = 6) Control Command 2 Reg (Addr = 7) 8/16-bit Data Bus Control Control Command 1 Command 1Transmit Receive FIFO FIFO Internal Registers Inderect Access Control Command 2 Transmit FIFO Interrupt Figure 5 - Overview of the SSI+MII Interface 3.1 3.1.1 Register Configuration, Frame Transmission, and Frame Reception Register Configuration The ZL50410 has many programmable parameters, covering such functions as QoS weights, VLAN control, and port mirroring setup. In managed mode, the CPU interface provides an easy way of configuring these parameters. The parameters are contained in 8-bit configuration registers. The device allows indirect access to these registers, as follows: • • • If operating in 8-bit interface mode, two “index” registers (addresses 000b and 001b) need to be written, to indicate the desired 16-bit register address. In 16-bit mode, only one register (address 000b) needs to be written for the desired 16-bit register address. In serial mode, the address, command and data are shifted in serially. To access the configuration registers, only one “index” register (addresses 000b) needs to be written with the configuration register address. The desired data can be written into or read from the “data” register (address 010b). • For example, if “XX” is required to be written to register “YY”, a write of “YY” is required to write to address “000b” (Index register). Then, a write of “XX” is required to write to address “010b” (Data Register). This completes the register write and register “YY” will contain the value of “XX”. To indirectly configure the register addressed by the index register(s), a “data” register (address 010b) must be written with the desired 8-bit data. • The ZL50410 supports special register-write in serial and 16-bit mode. This allows CPU to write to two consecutive configuration registers in a single write operation. By writing to bit[14] of configuration 29 Zarlink Semiconductor Inc. ZL50410 Data Sheet register address, CPU can write 16-bit data to address 010b. Lower 8 bit of data is for the address specified in index register and upper 8 bit of data is for the address + 1. In 8-bit mode, this special feature will be ignored. • • 15 14 INC R/W SP W 13 12 0 11 Reserved 12 Bit Register Address Similarly, to read the value in the register addressed by the index register(s), the “data” register can now simply be read. The ZL50410 supports an incremental read/write. If CPU requires to read or write to the configuration registers incrementally, CPU only has to write to index register once with the MSB of configuration register address set and then CPU can continuously reading or writing to “data” register (010b). In summary, access to the many internal registers is carried out simply by directly accessing only two registers – one register to indicate the index of the desired parameter, and one register to read or write a value. Of course, because there is only one bus master, there can never be any conflict between reading and writing the configuration registers. 3.1.2 Rx/Tx of Standard Ethernet Frames In serial mode with MII, the MII interface is used for CPU to transmit and receive Ethernet frames. In 8/16-bit or serial only mode, the Ethernet frame is transmitted and received through the CPU interface. There is no ability to send/receive Ethernet frames in unmanaged mode. To transmit a frame from the CPU in 8/16-bit or serial only mode: • • The CPU writes to the “data frame” register (address 011) with the frame size, destination port number, and frame status. After writing all the transmitting status bytes, it then writes the data it wants to transmit (minimum 64 bytes). The ZL50410 forwards the Ethernet frame to the desired destination port, no longer distinguishing the fact that the frame originated from the CPU. To receive a frame into the CPU in 8/16-bit or serial only mode: • • • The CPU receives an interrupt when an Ethernet frame is available to be received. Frame information arrives first in the data frame register. This includes source port number, frame size, and VLAN tag. The actual data follows the frame information. The CPU uses the frame size information to read the frame out. To transmit a frame from the CPU with MII interface: • • • ZL50410 acts as a PHY to provide receive clock (RXCLK) to CPU so the CPU will depend on this receive clock to send packets to ZL50410 ZL50410 has the ability to halt the receive clock if the receive FIFO of ZL50410 is overflow. Transmitting from CPU to ZL50410 will resume once the receive FIFO of ZL50410 is no longer overflow Follow the standard Ethernet transmission format. CPU assert receive data valid (RXDV) before transmitting data to ZL50410 and de-assert RXDV after transmitting the last data To receive a frame into the CPU with MII interface: • • • ZL50410 acts as a PHY to provide transmit clock (TXCLK) to CPU so the CPU will depend on the transmit clock to receive packets from ZL50410 ZL50410 has the ability to halt the transmit clock if the transmit FIFO of ZL50410 is under-run. CPU will resume receiving packets from ZL50410 once the transmit FIFO of ZL50410 is no longer under-run Follow the standard Ethernet transmission format. CPU will see transmit enable (TXEN) be asserted by ZL50410 and CPU can start receiving data. CPU will stop receiving data once TXEN is de-asserted by ZL50410. 30 Zarlink Semiconductor Inc. ZL50410 Data Sheet In summary, in 8/16-bit or serial only mode, receiving and transmitting frames to and from the CPU is a simple process that uses one direct access register only. In serial mode with MII interface, the CPU will be allowed to transmit and receive frames using standard IEEE 802.3 Ethernet transmission format. The details of sending an Ethernet Frame via the CPU interface is described in the Processor Interface Application Note, ZLAN-26. 3.1.3 Control Frames In addition to standard Ethernet frames described in the preceding section, the CPU is also called upon to handle special “Control frames,” generated by the ZL50410 and sent to the CPU. These proprietary frames are related to such tasks as statistics collection, MAC address learning, and aging, etc… All Control frames are up to 40 bytes long. Transmitting and receiving these frames is similar to transmitting and receiving Ethernet frames, except that the register accessed is the “Control frame data” register (address 111). Specifically, there are the following types of control frames generated by the CPU and sent to the ZL50410: • • • • • • • • • • • Memory read request Memory write request Learn Unicast MAC address Delete Unicast MAC address Search Unicast MAC address Learn IP Multicast address Delete IP Multicast address Search IP Multicast address Learn Multicast MAC address Delete Multicast MAC address Search Multicast MAC address Note: Memory read and write requests by the CPU may include all internal memories which include statistic counters, MAC address control link table and the 2Mbit (256KB) memory block. In addition, the following types of Control frames are generated by the ZL50410 and sent to the CPU: • • • • • • • • • Interrupt CPU when statistics counter rolls over Response to memory read request from CPU Learn Unicast MAC address Delete Unicast MAC address Delete Multicast MAC address Delete IP Multicast address Response to search Unicast MAC address request from CPU Response to search IP Multicast address request from CPU Response to search Multicast MAC address request from CPU The format of the Control Frame is described in the Processor Interface application note, ZLAN-26. 3.2 I2C Interface The I²C interface serves the function of configuring the ZL50410 at boot time. The master is the ZL50410, and the slave is the EEPROM memory. The I²C interface uses two bus lines, a serial data line (SDA) and a serial clock line (SCL). The SCL line carries the control signals that facilitate the transfer of information from EEPROM to the switch. Data transfer is 8-bit serial and bidirectional, at 50 Kbps. Data transfer is performed between master and slave IC using a request / acknowledgment style of protocol. The master IC generates the timing signals and terminates data transfer. Figure 6 depicts the data transfer format. The slave address is the memory address of the EEPROM. Refer to “ZL50410 Register Description” on page 60 for I²C address for each register. 31 Zarlink Semiconductor Inc. ZL50410 START SLAVE ADDRESS R/W ACK DATA 1 (8bits) Data Sheet ACK DATA 2 ACK DATA M ACK STOP Figure 6 - Data Transfer Format for I²C Interface 3.2.1 Start Condition Generated by the master (in our case, the ZL50410). The bus is considered to be busy after the Start condition is generated. The Start condition occurs if while the SCL line is High, there is a High-to-Low transition of the SDA line. Other than in the Start condition (and Stop condition), the data on the SDA line must be stable during the High period of SCL. The High or Low state of SDA can only change when SCL is Low. In addition, when the I²C bus is free, both lines are High. 3.2.2 Address The first byte after the Start condition determines which slave the master will select. The slave in our case is the EEPROM. The first seven bits of the first data byte make up the slave address. 3.2.3 Data Direction The eighth bit in the first byte after the Start condition determines the direction (R/W) of the message. A master transmitter sets this bit to W; a master receiver sets this bit to R. 3.2.4 Acknowledgment Like all clock pulses, the acknowledgment-related clock pulse is generated by the master. However, the transmitter releases the SDA line (High) during the acknowledgment clock pulse. Furthermore, the receiver must pull-down the SDA line during the acknowledge pulse so that it remains stable Low during the High period of this clock pulse. An acknowledgment pulse follows every byte transfer. If a slave receiver does not acknowledge after any byte, then the master generates a Stop condition and aborts the transfer. If a master receiver does not acknowledge after any byte, then the slave transmitter must release the SDA line to let the master generate the Stop condition. 3.2.5 Data After the first byte containing the address, all bytes that follow are data bytes. Each byte must be followed by an acknowledge bit. Data is transferred MSB first. 3.2.6 Stop Condition Generated by the master. The bus is considered to be free after the Stop condition is generated. The Stop condition occurs if while the SCL line is High, there is a Low-to-High transition of the SDA line. 3.3 Synchronous Serial Interface The synchronous serial interface (SSI) serves the function of configuring the ZL50410 not at boot time but via a PC. The PC serves as master and the ZL50410 serves as slave. The protocol for the synchronous serial interface is nearly identical to the I²C protocol. The main difference is that there is no acknowledgment bit after each byte of data transferred. Debounce logic on the clock signal (STROBE) can be turned off to speedup command time. 3 ID bits are used to allow up to eight ZL50410 devices to share the same synchronous serial interface. The ID of each device can be setup by bootstrap. To reduce the number of signals required, the register address, command and data are shifted in serially through the DATAIN pin. STROBE- pin is used as the shift clock. DATAOUT pin is used as data return path. 32 Zarlink Semiconductor Inc. ZL50410 Data Sheet Each command consists of four parts. • • • • START pulse Register Address Read or Write command Data to be written or read back Write operation can be aborted in the middle by sending an ABORT pulse to the ZL50410. Read operation can only be aborted before issuing the read command to the ZL50410. A START command is detected when DATAIN is sampled high when STROBE- rise and DATAIN is sampled low when STROBE- fall. An ABORT command is detected when DATAIN is sampled low when STROBE- rise and DATAIN is sampled high when STROBE- fall. 3.3.1 Write Command All registers in ZL50410 can be modified through this synchronous serial interface. Once the data has been sent, two extra STOBE clocks must be generated to indicate the end of the write command. The DATAIN line should be held high for these two pulses. STROBE2 Extra clocks after last transfer DATAIN D0 ID0 START ID1 ID2 A0 ID A1 A2 ADDR W D0 D1 D2 D3 CMD ... D12 D13 D14 D15 DATA Figure 7 - Serial Interface Write Command Functional Timing 3.3.2 Read Command All registers in ZL50410 can be read through this synchronous serial interface. STROBE- DATAIN D0 ID0 START ID1 ID ID2 A0 A1 A2 R ADDR CMD DATAOUT AUTOFD- DATA D0 D1 D2 ... D12 D13 D14 D15 Figure 8 - Serial Interface Read Command Functional Timing 33 Zarlink Semiconductor Inc. ZL50410 4.0 Data Forwarding Protocol 4.1 Unicast Data Frame Forwarding Data Sheet When a frame arrives, it is assigned a handle in memory by the Frame Control Buffer Manager (FCB Manager). An FCB handle will always be available, because of advance buffer reservations. The memory (SRAM) interface is a 64-bit bus, connected to internal memory block. The Receive DMA (RxDMA) is responsible for multiplexing the data and the address. On a port’s “turn”, the RxDMA will move 8 bytes (or up to the end-of-frame) from the port’s associated RxFIFO into memory (Frame Data Buffer, or FDB). Once an entire frame has been moved to the FDB, and a good end-of-frame (EOF) has been received, the Rx interface makes a switch request. The RxDMA arbitrates among multiple switch requests. The switch request consists of the first 64 bytes of a frame, containing among other things, the source and destination MAC addresses of the frame. The search engine places a switch response in the switch response queue of the frame engine when done. Among other information, the search engine will have resolved the destination port of the frame and will have determined that the frame is unicast. After processing the switch response, the Transmission Queue Manager (TxQ manager) of the frame engine is responsible for notifying the destination port that it has a frame to forward. But first, the TxQ manager has to decide whether or not to drop the frame, based on global FDB reservations and usage, as well as TxQ occupancy at the destination. If the frame is not dropped, then the TxQ manager links the frame’s FCB to the correct per-port-per-class TxQ. The switch response will come with 8 classified results. The TxQ manager will map this result into the per-port-per-class queue. Unicast TxQ’s are linked lists of transmission jobs, represented by their associated frames’ FCB’s. There is one linked list for each transmission class for each port. There are 2 transmission classes for each of the 8 RMAC ports, and 4 classes for the GMAC and CPU ports – a total of 24 unicast queues. The TxQ manager is responsible for scheduling transmission among the queues representing different classes for a port. When the port control module determines that there is room in the MAC Transmission FIFO (TxFIFO) for another frame, it requests the handle of a new frame from the TxQ manager. The TxQ manager chooses among the head-of-line (HOL) frames from the per-class queues for that port, using a Zarlink Semiconductor scheduling algorithm. The Transmission DMA (TxDMA) is responsible for multiplexing the data and the address. On a port’s turn, the TxDMA will move 8 bytes (or up to the EOF) from memory into the port’s associated TxFIFO. After reading the EOF, the port control requests a FCB release for that frame. The TxDMA arbitrates among multiple buffer release requests. The frame is transmitted from the TxFIFO to the line. 4.2 Multicast Data Frame Forwarding After receiving the switch response, the TxQ manager has to make the dropping decision. A global decision to drop can be made, based on global FDB utilization and reservations. If so, then the FCB is released and the frame is dropped. In addition, a selective decision to drop can be made, based on the TxQ occupancy at some subset of the multicast packet’s destinations. If so, then the frame is dropped at some destinations but not others, and the FCB is not released. If the frame is not dropped at a particular destination port, then the TxQ manager formats an entry in the multicast queue for that port and class. Multicast queues are physical queues (unlike the linked lists for unicast frames). There are 2 multicast queues for each of the 8 RMAC ports. There are 4 multicast queues for the GMAC and CPU ports. The mapping from the classified result to the priority queue is the same as the unicast traffic. By default, for the RMAC ports to map the 8 transmit priorities into 2 multicast queues, the 2 LSB are discarded. For the GMAC and CPU ports, to map the 8 transmit priorities into 4 multicast queues, the LSB is discarded. The priority mapping can be modified through memory configuration command. The multicast queue that is in FIFO format shares the 34 Zarlink Semiconductor Inc. ZL50410 Data Sheet space in the internal memory block. The size and starting address can also be programmed through memory configuration command. During scheduling, the TxQ manager treats the unicast queue and the multicast queue of the same class as one logical queue. The older head of line of the two queues is forwarded first. The port control requests a FCB release only after the EOF for the multicast frame has been read by all ports to which the frame is destined. 4.3 Frame Forwarding To and From CPU Frame forwarding from the CPU port to a regular transmission port is nearly the same as forwarding between transmission ports. The only difference is that the physical destination port must be indicated in addition to the destination MAC address. Frame forwarding to the CPU port is nearly the same as forwarding to a regular transmission port. The only difference is in frame scheduling. Instead of using the patent-pending Zarlink Semiconductor scheduling algorithms, scheduling for the CPU port is simply based on strict priority. That is, a frame in a high priority queue will always be transmitted before a frame in a lower priority queue. There are four output queues to the CPU and one receive queue. 5.0 Search Engine 5.1 Search Engine Overview The ZL50410 search engine is optimized for high throughput searching, with enhanced features to support: • • • • • • • • • • Up to 4 K of Unicast/Multicast MAC addresses and IP Multicast MAC addresses Up to 4 K VLANs Private VLAN Edge (protected ports) support Up to 8 groups of port trunking Traffic classification into 2 (or 4 for GMAC) transmission priorities, and 2 drop precedence levels Packet filtering based on MAC address, Protocol or Logical Port number Security Up to 4 K IP Multicast groups Individual Flooding, Broadcast, Multicast Storm Control MAC address learning and aging 5.2 Basic Flow Shortly after a frame enters the ZL50410 and is written to the Frame Data Buffer (FDB), the frame engine generates a Switch Request, which is sent to the search engine. The switch request consists of the first 64 bytes of the frame, which contain all the necessary information for the search engine to perform its task. When the search engine is done, it writes to the Switch Response Queue, and the frame engine uses the information provided in that queue for scheduling and forwarding. In performing its task, the search engine extracts and compresses the useful information from the 64-byte switch request. Among the information extracted are the source and destination MAC addresses, the packet’s VLAN ID, and whether the frame is unicast or multicast or broadcast. Requests are sent to the SRAM to locate the associated entries in the MCT table. When all the information has been collected from the SRAM, the search engine has to compare the MAC address on the current entry with the MAC address for which it is searching. If it is not a match, the process is repeated on the internal MCT Table. All MCT entries other than the first of each linked list are maintained internal to the chip. If the desired MAC address is still not found, then the result is either learning (source MAC address unknown) or flooding (destination MAC address unknown). In addition, VLAN information is used to select the correct set of destination ports for the frame (for multicast), or to verify that the frame’s destination port is associated with the VLAN (for unicast). 35 Zarlink Semiconductor Inc. ZL50410 Data Sheet If the destination MAC address belongs to a port trunk, then the trunk number is retrieved instead of the port number. But on which port of the trunk will the frame be transmitted? This is easily computed using a hash of the source and destination MAC addresses. When all the information is compiled, the switch response is generated, as stated earlier. The search engine also interacts with the CPU with regard to learning and aging. 5.3 5.3.1 Search, Learning, and Aging MAC Search The search block performs source MAC address and destination MAC address (or destination IP address for IP multicast) searching. As we indicated earlier, if a match is not found, then the next entry in the linked list must be examined, and so on until a match is found or the end of the list is reached. In tag-based VLAN mode, if the frame is unicast, and the frame's destination port is recognized as a member of the VLAN, then the frame is forwarded to that port; otherwise, the frame is forwarded to all the members in the VLAN domain. If the frame is multicast or broadcast, the frame is forwarded to all the members in the VLAN. Moreover, if port trunking is enabled, this block selects the destination port (among those in the trunk group). In private VLAN Edge (protected ports) mode, the private VLAN domain is used for final qualification at the egress port. In port based VLAN mode, a bit map is used to determine whether the frame should be forwarded to the outgoing port. The main difference in this mode is that the bit map is not dynamic. Ports cannot enter and exit groups because of real-time learning made by a CPU. The MAC search block is also responsible for updating the source MAC address timestamp used for aging. 5.3.2 Learning The learning module learns new MAC addresses and performs port change operations on the MCT database. The goal of learning is to update this database as the networking environment changes over time. When CPU reporting is enabled, learning and port change will be performed when the CPU request queue has room, and a “Learn MAC Address” message is sent to the CPU. 5.3.3 Aging Aging time is controlled by register 400h and 401h. The aging module scans and ages MCT entries based on a programmable “age out” time interval. As we indicated earlier, the search module updates the source MAC address timestamps for each frame it processes. When an entry is ready to be aged, the entry is removed from the table, and a “Delete MAC Address” message is sent to inform the CPU. Supported MAC entry types are: dynamic, static, source filter, destination filter, IP multicast, source and destination filter, secure and multicast MAC address. Only dynamic entries can be aged; all others are static. The MAC entry type is stored in the “status” field of the MCT data structure. 5.4 MAC Address Filtering The ZL50410's implementation of intelligent traffic switching provides filters for source and destination MAC addresses. This feature filters unnecessary traffic, thereby providing intelligent control over traffic flows and broadcast traffic. Broadcast, unknown unicast or unknown multicast MAC address and unknown IP multicast address can also be filter on per VLAN basis. 36 Zarlink Semiconductor Inc. ZL50410 Data Sheet MAC address filtering allows the ZL50410 to block an incoming packet to an interface when it sees a specified MAC address in either the source address or destination address of the incoming packet. For example, if your network is congested because of high utilization from a MAC address, you can filter all traffic transmitted from that address and restore network flow, while you troubleshoot the problem. 5.5 Protocol Filtering Packet filtering can be performed based on protocol type field in the packets. Up to eight protocols can be programmed to filter or allow packet to pass through the switch. 5.6 Logical Port Filtering Similar to protocol filtering, if the packet’s logical ports match the programmable registers, the packet can be filtered or passed through the switch. Up to eight programmable ports and one ranges can be assigned. 5.7 Quality of Service Quality of Service (QoS) refers to the ability of a network to provide better service to selected network traffic over various technologies. Primary goals of QoS include dedicated bandwidth, controlled jitter and latency (required by some real-time and interactive traffic), and improved loss characteristics. Traditional Ethernet networks have had no prioritization of traffic. Without a protocol to prioritize or differentiate traffic, a service level known as “best effort” attempts to get all the packets to their intended destinations with minimum delay; however, there are no guarantees. In a congested network or when a low-performance switch/router is overloaded, “best effort” becomes unsuitable for delay-sensitive traffic and mission-critical data transmission. The advent of QoS for packet-based systems accommodates the integration of delay-sensitive video and multimedia traffic onto any existing Ethernet network. It also alleviates the congestion issues that have previously plagued such “best effort” networking systems. QoS provides Ethernet networks with the breakthrough technology to prioritize traffic and ensure that a certain transmission will have a guaranteed minimum amount of bandwidth. Extensive core QoS mechanisms are built into the ZL50410 architecture to ensure policy enforcement and buffering of the ingress port, as well as weighted fair-queue (WFQ) scheduling at the egress port. In the ZL50410, QoS-based policies sort traffic into a small number of classes and mark the packets accordingly. The QoS identifier provides specific treatment to traffic in different classes, so that different quality of service is provided to each class. Frame and packet scheduling and discarding policies are determined by the class to which the frames and packets belong. For example, the overall service given to frames and packets in the premium class will be better than that given to the standard class; the premium class is expected to experience lower loss rate or delay. The ZL50410 supports the following QoS techniques: • • • • In a port-based setup, any station connected to the same physical port of the switch will have the same transmit priority. In a tag-based setup, a 3-bit field in the VLAN tag provides the priority of the packet. This priority can be mapped to different queues in the switch to provide QoS. In a TOS/DS-based set up, TOS stands for “Type of Service” that may include “minimize delay,” “maximize throughput,” or “maximize reliability.” Network nodes may select routing paths or forwarding behaviours that are suitably engineered to satisfy the service request. In a logical port-based set up, a logical port provides the application information of the packet. Certain applications are more sensitive to delays than others; using logical ports to classify packets can help speed up delay sensitive applications, such as VoIP. 37 Zarlink Semiconductor Inc. ZL50410 5.8 Data Sheet Priority Classification Rule Figure 9 shows the ZL50410 priority classification rule. Fix Port Priority? Yes Use Default port settings No TOS Precedence over VLAN? (QOSC Register bit 5) Yes No Use VLAN priority Yes No VLAN Tag? IP Frame? No IP Frame? Yes Yes Use Logical Port? No No Use TOS Yes Use Default port settings Use logical port Figure 9 - Priority Classification Rule 5.9 Port and Tag Based VLAN The ZL50410 supports two models for determining and controlling how a packet gets assigned to a VLAN: port priority and tag -based VLAN. 5.9.1 Port-Based VLAN An administrator can use the PVMAP Registers to configure the ZL50410 for port-based VLAN (see “Register Definition” on page 60). For example, ports 1-3 might be assigned to the Marketing VLAN, ports 4-6 to the Engineering VLAN, and ports 7-9 to the Administrative VLAN. The ZL50410 determines the VLAN membership of each packet by noting the port on which it arrives. From there, the ZL50410 determines which outgoing port(s) is/are eligible to transmit each packet, or whether the packet should be discarded. 38 Zarlink Semiconductor Inc. ZL50410 Data Sheet Destination Port Numbers Bit Map Port Registers 9 Register for Port #0 PVMAP00_0[7:0] to PVMAP00_1[1:0] … 2 1 0 0 1 1 0 Register for Port #1 PVMAP01_0[7:0] to PVMAP01_1[1:0] 0 1 0 1 Register for Port #2 PVMAP02_0[7:0] to PVMAP02_1[1:0] 0 0 0 0 0 0 0 0 … Register for Port #9 PVMAP09_0[7:0] to PVMAP09_1[1:0] Table 7 - Port-Based VLAN Mapping For example, in the above table a 1 denotes that an outgoing port is eligible to receive a packet from an incoming port. A 0 (zero) denotes that an outgoing port is not eligible to receive a packet from an incoming port. In this example: • • • Data packets received at port #0 are eligible to be sent to outgoing ports 1 and 2. Data packets received at port #1 are eligible to be sent to outgoing ports 0 and 2. Data packets received at port #2 are NOT eligible to be sent to ports 0 and 1. 5.9.2 Tag-Based VLAN The ZL50410 supports the IEEE 802.1q specification for “tagging” frames. The specification defines a way to coordinate VLANs across multiple switches. In the specification, an additional 4-octet header (or “tag”) is inserted in a frame after the source MAC address and before the frame type. 12 bits of the tag are used to define the VLAN ID. Packets are then switched through the network with each ZL50410 simply swapping the incoming tag for an appropriate forwarding tag rather than processing each packet's contents to determine the path. This approach minimizes the processing needed once the packet enters the tag-switched network. In addition, coordinating VLAN IDs across multiple switches enables VLANs to extend to multiple switches. Up to 4 K VLANs are supported in the ZL50410. When tag-based VLAN is enabled, each MAC address is learned with it associated VLAN. See IEEE 802.1Q VLAN Setup application note, ZLAN-51, for more information. 5.9.3 VLAN Stacking (Q-in-Q) The ZL50410 partially supports VLAN stacking, also called IEEE 802.1Q-in-Q. This technology allows an additional VLAN tag, called a provider VLAN tag, to be inserted into an existing IEEE 802.1Q tagged Ethernet frame. This technology has been widely adapted in Metro Ethernet applications since it provides a very cost-effective solution to transport multiple customers' VLAN across the service provider's MAN/WAN without interfering each other. The below figure illustrates the IEEE 802.1Q frame and the Q-in-Q frame, where the provider VLAN tag is inserted in front of the IEEE 802.1Q tag. 39 Zarlink Semiconductor Inc. ZL50410 Data Sheet IEEE 802.1Q Tagged Ethernet Frame Dest MAC (6 Bytes) IEEE 802.1Q Tag VLAN VLAN TCI Tag Protocol ID (2 Bytes) (0x8100) Source MAC (6 Bytes) Source MAC (6 Bytes) Data Provider Tag IEEE 802.1Q-in-Q Tagged Ethernet Frame Dest MAC (6 Bytes) Type/Length (2 Byte) (P-VLAN) VLAN Tag Protocol ID (0x88A8*) VLAN TCI (2 Bytes) IEEE 802.1Q Tag VLAN VLAN TCI Tag Protocol ID (2 Bytes) (0x8100) Type/Length (2 Byte) Data IEEE 802.1Q Tag TPID = 0x8100 * Provider Tag TPID = Configurable on per device basis Figure 10 - Q-in-Q Tagged Ethernet Frame The value of the TPID of the Provider VLAN tag is not assigned in the IEEE 802.1ad standard. The ZL50410 provides a global configurable TPID but only supports the Extreme EtherType TPID (i.e. the stacked VLAN tag cannot equal 0x81-00). See Stacked VLAN application note, ZLAN-82, for more information. 5.9.4 Private VLAN Edge The PVLAN Edge (protected port) is a feature that has only local significance to the switch (unlike Private VLANs), and there is no isolation provided between two protected ports located on different L2 switches. A protected port does not forward any traffic (unicast, multicast, or broadcast) to any other port that is also a protected port in the same switch. Traffic cannot be forwarded between protected ports at L2, thus, all traffic passing between protected ports must be forwarded through a Layer 3 (L3) device. The ZL50410 supports private VLAN Edge by allowing each of the RMAC ports to setup a private VLAN domain, defined by registers PVLAN_Pn. The private VLAN domain is used for final qualification at the egress port. See Private VLAN Edge application note, ZLAN-130, for more information. 5.10 IP Multicast Switching The ZL50410 supports IP Multicast Filtering by: • • Passively snooping on the IGMP Query and IGMP Report packets transferred between IP Multicast Routers and IP Multicast host groups to learn IP Multicast group members, and Actively sending IGMP Query messages to solicit IP Multicast group members. The purpose of IP multicast filtering is to optimize a switched network performance, so multicast packets will only be forwarded to those ports containing multicast group hosts members and routers instead of flooding to all ports in the subnet (VLAN). The ZL50410 with IP multicast filtering/switching capability not only passively monitor IGMP Query and Report messages, DVMRP Probe messages, PIM, and MOSPF Hello messages; they also actively send IGMP Query messages to learn locations of multicast routers and member hosts in multicast groups within each VLAN. See IP Multicast Switching application note, ZLAN-52, for more information. 40 Zarlink Semiconductor Inc. ZL50410 6.0 Frame Engine 6.1 Data Forwarding Summary Data Sheet When a frame enters the device at the RxMAC, the RxDMA will move the data from the MAC RxFIFO to the FDB. Data is moved in 8-byte granules in conjunction with the scheme for the SRAM interface. A switch request is sent to the Search Engine. The Search Engine processes the switch request. A switch response is sent back to the Frame Engine and indicates whether the frame is unicast or multicast, and its destination port or ports. On receiving the response, the Frame Engine will check all the QoS related information and decide if this frame can be forwarded. A Transmission Scheduling Request is sent in the form of a signal notifying the TxQ manager. Upon receiving a Transmission Scheduling Request, the device will format an entry in the appropriate Transmission Scheduling Queue (TxSch Q) or Queues. There are 2 TxSch Q for each RMAC port (and 4 per GMAC and CPU ports), one for each priority. Creation of a queue entry either involves linking a new job to the appropriate linked list if unicast, or adding an entry to a physical queue if multicast. When the port is ready to accept the next frame, the TxQ manager will get the head-of-line (HOL) entry of one of the TxSch Qs, according to the transmission scheduling algorithm (so as to ensure per-class quality of service). (The unicast linked list and the multicast queue for the same port-class pair are treated as one logical queue. The older HOL between the two queues goes first. The TxDMA will pull frame data from the memory and forward it granule-by-granule to the MAC TxFIFO of the destination port. 6.2 Frame Engine Details This section briefly describes the functions of each of the modules of the ZL50410 frame engine. 6.2.1 FCB Manager The FCB manager allocates FCB handles to incoming frames, and releases FCB handles upon frame departure. The FCB manager is also responsible for enforcing buffer reservations and limits that will be used for QoS control and source port flow control. The default values can be determined by referring to Section 7.6 on page 45. The frame buffer is managed in a 128bytes block unit. During initialization, this block will link all the available blocks in a free buffer list. When each port is ready to receive, this module hands the buffer handle to each requesting port. The FCB manager will also link the released buffer back into the free buffer list. The maximum buffer size can be increased from the standard 1518 bytes (1522 with VLAN tag) to up to 4 K bytes. This is done using BUF_LIMIT, and is enabled on a per port basis via bit [1] in ECR3Pn. See Buffer Allocation application note, ZLAN-47, for more information. 6.2.2 Rx Interface The Rx interface is mainly responsible for communicating with the RxMAC. It keeps track of the start and end of frame and frame status (good or bad). Upon receiving an end of frame that is good, the Rx interface makes a switch request. 6.2.3 RxDMA The RxDMA arbitrates among switch requests from each Rx interface. It also buffers the first 64 bytes of each frame for use by the search engine when the switch request has been made. 41 Zarlink Semiconductor Inc. ZL50410 6.2.4 Data Sheet TxQ Manager First, the TxQ manager checks the per-class queue status and global reserved resource situation, and using this information, makes the frame dropping decision after receiving a switch response. The dropping decision includes the head-of-link blocking avoidance if the source port is not flow control enabled. If the decision is not to drop, the TxQ manager links the unicast frame’s FCB to the correct per-port-per-class TxQ and updates the FCB information. If multicast, the TxQ manager writes to the multicast queue for that port and class and also update the FCB information including the duplicate count for this multicast frame. The TxQ manager can also trigger source port flow control for the incoming frame’s source if that port is flow control enabled. Second, the TxQ manager handles transmission scheduling; it schedules transmission among the queues representing different classes for a port. Once a frame has been scheduled, the TxQ manager reads the FCB information and writes to the correct port control module. The detail of the QoS decision guideline is described in chapter 5. 6.2.5 Port Control The port control module calculates the SRAM read address for the frame currently being transmitted. It also writes start of frame information and an end of frame flag to the MAC TxFIFO. When transmission is done, the port control module requests that the buffer be released. 6.2.6 TxDMA The TxDMA multiplexes data and address from port control, and arbitrates among buffer release requests from the port control modules. 7.0 Quality of Service and Flow Control 7.1 Model Quality of service is an all-encompassing term for which different people have different interpretations. In general, the approach to quality of service described here assumes that we do not know the offered traffic pattern. We also assume that the incoming traffic is not policed or shaped. Furthermore, we assume that the network manager knows his applications, such as voice, file transfer, or web browsing, and their relative importance. The manager can then subdivide the applications into classes and set up a service contract with each. The contract may consist of bandwidth or latency assurances per class. Sometimes it may even reflect an estimate of the traffic mix offered to the switch. As an added bonus, although we do not assume anything about the arrival pattern, if the incoming traffic is policed or shaped, we may be able to provide additional assurances about our switch’s performance. Table 8 shows examples of QoS applications with three transmission priorities, but best effort (P0) traffic may form a fourth class with no bandwidth or latency assurances. GMAC port actually has four total transmission priorities. 42 Zarlink Semiconductor Inc. ZL50410 Goals TotalAssured Bandwidth (user defined) Data Sheet Low Drop Probability (low-drop) High Drop Probability (high-drop) Highest transmission priority, P3 50 Mbps Apps: phone calls, circuit emulation. Latency: < 1 ms. Drop: No drop if P3 not oversubscribed. Apps: training video. Latency: < 1 ms. Drop: No drop if P3 not oversubscribed; first P3 to drop otherwise. Middle transmission priority, P2 37.5 Mbps Apps: interactive apps, Web business. Latency: < 4-5 ms. Drop: No drop if P2 not oversubscribed. Apps: non-critical interactive apps. Latency: < 4-5 ms. Drop: No drop if P2 not oversubscribed; firstP2 to drop otherwise. Low transmission priority, P1 12.5 Mbps Apps: emails, file backups. Latency: < 16 ms desired, but not critical. Drop: No drop if P1 not oversubscribed. Apps: casual web browsing. Latency: < 16 ms desired, but not critical. Drop: No drop if P1 not oversubscribed; first to drop otherwise. Total 100 Mbps Table 8 - Two-dimensional World Traffic A class is capable of offering traffic that exceeds the contracted bandwidth. A well-behaved class offers traffic at a rate no greater than the agreed-upon rate. By contrast, a misbehaving class offers traffic that exceeds the agreed-upon rate. A misbehaving class is formed from an aggregation of misbehaving microflows. To achieve high link utilization, a misbehaving class is allowed to use any idle bandwidth. However, such leniency must not degrade the quality of service (QoS) received by well-behaved classes. As Table 8 illustrates, the six traffic types may each have their own distinct properties and applications. As shown, classes may receive bandwidth assurances or latency bounds. In the table, P3, the highest transmission class, requires that all frames be transmitted within 1 ms, and receives 50% of the 100 Mbps of bandwidth at that port. Best-effort (P0) traffic forms a fourth class that only receives bandwidth when none of the other classes have any traffic to offer. It is also possible to add a fourth class that has strict priority over the other three; if this class has even one frame to transmit, then it goes first. In the ZL50410, each RMAC port will support two total classes, and the GMAC port will support four classes. We will discuss the various modes of scheduling these classes in the next section. In addition, each transmission class has two subclasses, high-drop and low-drop. Well-behaved users should rarely lose packets. But poorly behaved users–users who send frames at too high a rate – will encounter frame loss, and the first to be discarded will be high-drop. Of course, if this is insufficient to resolve the congestion, eventually some low-drop frames are dropped, and then all frames in the worst case. Table 8 shows that different types of applications may be placed in different boxes in the traffic table. For example, casual web browsing fits into the category of high-loss, high-latency-tolerant traffic, whereas VoIP fits into the category of low-loss, low-latency traffic. 7.2 Two QoS Configurations There are two basic pieces to QoS scheduling in the GMAC port of ZL50410: strict priority (SP) or weighted fair queuing (WFQ). The only configuration for a RMAC and CPU port is strict priority between the queues. 43 Zarlink Semiconductor Inc. ZL50410 7.2.1 Data Sheet Strict Priority When strict priority is part of the scheduling algorithm, if a queue has any frame to transmit, it goes first. For RMAC ports, this is an easy way to provide the different service. For all recognizable traffic, the bandwidth is guaranteed to 100% of the line rate. This scheme works as long as the overall high priority bandwidth is not over the line rate and the latency on all the low priority traffic is don’t care. The strict priority queue in the GMAC and CPU ports is similar to RMAC ports other than having 4 queues instead of 2 queues. The priority queue P0 can be scheduled only if the priority queue P1 is empty, so as to priority queues P2 and P3. The lowest priority queue is treated as best effort queue. Because we do not provide any assurances for best effort traffic, we do not enforce latency by dropping best effort traffic. Furthermore, because we assume that strict priority traffic is carefully controlled before entering the ZL50410, we do not enforce a fair bandwidth partition by dropping strict priority traffic. To summarize, dropping to enforce bandwidth or delay does not apply to strict priority or best effort queues. We only drop frames from best effort and strict priority queues when queue size is too long or global / class buffer resources become scarce. 7.2.2 Weighted Fair Queuing In some environments – for example, in an environment in which delay assurances are not required, but precise bandwidth partitioning on small time scales is essential, WFQ may be preferable to a strict assurance scheduling discipline. The ZL50410 provides this kind of scheduling algorithm on GMAC port only. The user sets four WFQ “weights” such that all weights are whole numbers and sum to 64. This provides per-class bandwidth partitioning with granular within 2%. In WFQ mode, though we do not assure frame latency, the ZL50410 still retains a set of dropping rules that helps to prevent congestion and trigger higher level protocol end-to-end flow control. 7.3 WRED Drop Threshold Management Support To avoid congestion, the Weighted Random Early Detection (WRED) logic drops packets according to specified parameters. The following table summarizes the behavior of the WRED logic. Px > WRED_L1 Px > WRED_L2 BM Reject High Drop X% 100% 100% Low Drop Y% Z% 100% Table 9 - WRED Logic Behaviour Px is the total byte count, in the priority queue x, can be the strict priority queue of RMAC ports and higher 3 priority queues for GMAC port. The WRED logic has two drop levels, depending on the value of Px. Each drop level has defined high-drop and low-drop percentages, which indicate the minimum and maximum percentages of the data that can be discarded. The X, Y Z percent can be programmed by the register RDRC0, RDRC1. All packets will be dropped only if the system runs out of the specific buffer resource, per class buffer or per source port buffer. The WRED thresholds of each queue can be programmed by the QOS control registers (refer to the register group 8). See Programming QoS Registers application note, ZLAN-42, for more information. 7.4 Shaper Although traffic shaping is not a primary function of the ZL50410, the chip does implement a shaper for every queue in the GMAC port. Our goal in shaping is to control the average rate of traffic exiting the ZL50410. If shaper is enabled, strict priority will be applied to that queue. The priority between two shaped queue is the same as in strict priority scheduling. Traffic rate is set using a programmable whole number, no greater than 64. For example, if the setting is 32, then the traffic rate transmit out of the shaped queue is 32/64 * 1000 Mbps = 500 Mbps. See Programming QoS Register application note, ZLAN-42, for more information. 44 Zarlink Semiconductor Inc. ZL50410 Data Sheet Also, when shaping is enabled, it is possible for a queue to explode in length if fed by a greedy source. The reason is that a shaper is by definition not work-conserving; that is, it may hold back from sending a packet even if the line is idle. Though we do have global resource management, we do nothing other than per port WRED to prevent this situation locally. We assume the traffic is policed at a prior stage to the ZL50410 or WRED dropping is fine and shall restrain this situation. 7.5 Rate Control The ZL50410 provides a rate control function on its RMAC ports. The concept is much the same as shaping, except that it applies to both ingress and egress directions and the control is per port rather than per queue. It provides a way of reducing the total bandwidth of all frames received from or transmitted to a port, to a rate below wire speed. As with shaping, the maximum burst size can also be configured. Rate control may be a valuable feature on RMAC ports in access applications where the service provider would like to limit the traffic received and transmitted by each port independently of each other, and independently of the physical line rate. The service provider can then provide differential pricing, based on the negotiated bandwidth requirements for each user. In such applications of the ZL50410, the GMAC port is viewed as an uplink port, where rate control is not desired. See Rate Control application note, ZLAN-33, for more information. 7.6 Buffer Management Because the number of FDB slots is a scarce resource, and because we want to ensure that one misbehaving source port or class cannot harm the performance of a well-behaved source port or class, we introduce the concept of buffer management into the ZL50410. Our buffer management scheme is designed to divide the total buffer space into numerous reserved regions and one shared pool, as shown in Figure 11 on page 46. As shown in the figure, the FDB pool is divided into several parts. A reserved region for temporary frames stores frames prior to receiving a switch response. Such a temporary region is necessary, because when the frame first enters the ZL50410, its destination port and class are as yet unknown, and so the decision to drop or not needs to be temporarily postponed. This ensures that every frame can be received first before subjecting them to the frame drop discipline after classifying. Three priority sections, one for each pair of the first six priority classes, ensure a programmable number of FDB slots per class. The lowest two classes do not receive any buffer reservation. Furthermore, a frame is stored in the region of the FDB corresponding to its class. As we have indicated, the eight classes use only two transmission scheduling queues for RMAC ports (four queues for the GMAC & CPU ports), but as far as buffer usage is concerned, there are still eight distinguishable classes. Another segment of the FDB reserves space for each of the 10 ports — 9 ports for Ethernet and one CPU port (port number 8). Each port has it’s own programmable source port reservation. These 10 reserved regions make sure that no well-behaved source port can be blocked by another misbehaving source port. In addition, there is a shared pool, which can store any type of frame. The frame engine allocates the frames first in the three priority sections. When the priority section is full or the packet has priority 1 or 0, the frame is allocated in the shared pool. Once the shared pool is full the frames are allocated in the section reserved for the source port. The following registers define the size of each section of the Frame data Buffer: - PR100_N - Port Reservation for RMAC Ports PR100_CPU - Port Reservation for CPU Port PRG - Port Reservation for GMAC Port SFCB - Share FCB Size C1RS - Class 1 Reserve Size (priority 2 & 3) C2RS - Class 2 Reserve Size (priority 4 & 5) C3RS - Class 3 Reserve Size (priority 6 & 7) 45 Zarlink Semiconductor Inc. ZL50410 Data Sheet Temporary reservation Rpri1 Rpri2 Rpri3 Shared Pool S Per Class Reservation Per Source Port Reservation Rp0 Rp1 Rp2 Rp3 Rp4 Rp5 Rp6 Rp7 Rp8 Rp9 (CPU) Figure 11 - Buffer Partition Scheme See Buffer Allocation application note, ZLAN-47, for more information. 7.6.1 Dropping When Buffers Are Scarce As already discussed, the WRED mechanism may drop frames on output queue status. In addition to these reasons for dropping, we also drop frames when global buffer space becomes scarce. The function of buffer management is to make sure that such dropping causes as little blocking as possible. If a received frame is dispatched to the best effort queue, the buffer management will check on the overall buffer situation plus the output queue status to decide the frame drop condition. If the source port has not enough buffer for it, the frame will be dropped. If the output queue reach the UCC (unicast congest control) and the shared buffer has run out, the frame will be dropped by b%. If the output queue reach the UCC and the source port reservation is lower than the buffer low threshold, the frame will be dropped. All the dropping functions are disabled if the source port is flow control capable. 7.7 Flow Control Basics Because frame loss is unacceptable for some applications, the ZL50410 provides a flow control option. When flow control is enabled, scarcity of source port buffer space may trigger a flow control signal; this signal tells a source port sending a packet to this switch, to temporarily hold off. While flow control offers the clear benefit of no packet loss, it also introduces a problem for quality of service. When a source port receives an Ethernet flow control signal, all microflows originating at that port, well-behaved or not, are halted. A single packet destined for a congested output can block other packets destined for un-congested outputs. The resulting head-of-line blocking phenomenon means that quality of service cannot be assured with high confidence when flow control is enabled. On the other hand, the ZL50410 will still prioritize the received frame disregarding the outgoing port flow control capability. If a frame is classified as high priority, it is still subjected to the WRED, which means the no-loss on the high priority queue is not guaranteed. To resolve this situation, the user may set the output port WRED threshold so high that may never be reached, or program the priority mapping table in the queue manager to map all the traffic to best effort queue on the flow control capable port. The first method has side impact on the global resource management since the port may hold too much per class resource that is scarce in the system. The second method, by nature, lost the benefit of prioritization. See Programming Flow Control Registers application note, ZLAN-44, for more information. 7.7.1 Unicast Flow Control For unicast frames, flow control is triggered by source port resource availability. Recall that the ZL50410’s buffer management scheme allocates a reserved number of FDB slots for each source port. If a programmed number of a source port’s reserved FDB slots have been used, then flow control Xoff is triggered. 46 Zarlink Semiconductor Inc. ZL50410 Data Sheet Xon is triggered when a port is currently being flow controlled, and all of that port’s reserved FDB slots have been released. Note that the ZL50410’s per-source-port FDB reservations assure that a source port that sends a single frame to a congested destination will not be flow controlled. 7.7.2 Multicast Flow Control Flow control for multicast frames is triggered by a global buffer counter. When the system exceeds a programmable threshold of multicast packets, Xoff is triggered. Xon is triggered when the system returns below this threshold. Note: If per-port flow control is on, QoS performance will be affected. 7.8 Mapping to IETF Diffserv Classes The mapping between priority classes discussed in this chapter and elsewhere is shown below. ZL50410 P3 P2 P1 P0 IETF NM+EF AF0 AF1 BE Table 10 - Mapping to IETF Diffserv Classes for GMAC & CPU Ports As the table illustrates, the classes of Table 10 are merged in pairs— P3 is used for network management (NM) and expedited forwarding service (EF) frames. Classes P2 and P1 correspond to an assured forwarding (AF) group of size 2. Finally, P0 is for best effort (BE) class. Features of the ZL50410 that correspond to the requirements of their associated IETF classes are summarized in the table below. Network management (NM) and Expedited forwarding (EF) Global buffer reservation for NM and EF Shaper for traffic on uplink port No dropping if admission controlled Assured forwarding (AF) Global buffer reservation for two AF classes Shaper for traffic on uplink port Random early discard, with programmable levels Best effort (BE) Service only when other queues are idle means that QoS not adversely affected Shaper for traffic on uplink port Random early discard, with programmable levels Traffic from flow control enabled ports automatically classified as BE Table 11 - ZL50410 Features Enabling IETF Diffserv Standards 7.9 Failover Backplane Feature The ZL50410 implements a hardware assisted link failure detection mechanism utilizing a Link Heart Beat (LHB) packet. The LHB packet format is defined as a 64-byte MAC control frame with a user defined opcode. The packet format is illustrated below: 01-80-C2-00-00-01 xx-xx-xx-xx-xx-xx 88-08 yy-yy 00-00-... CRC Where “xx-xx-xx-xx-xx-xx” is the source port MAC address and “yy-yy” is the special opcode defined by register setup (LHBReg0,1). The opcode “00-01” is reserved for the flow control packet. We recommend opcode “00-12” for the LHB packet. 47 Zarlink Semiconductor Inc. ZL50410 Data Sheet The LHB is done between two compatible MACs providing this function. A timer parameter will be set for both the receiver and transmitter (LHBTimer). On the transmission side, the MAC will monitor the transmission activities. If there is no activity for more than the set period, a LHB packet will be sent to its link partner. Therefore, there should always be at least one packet transmitted from the MAC for every period specified. On the receiving side, the MAC will also monitor the activity. If there is no good packet received for more than 2X the set period, an alarm will be raised to the CPU. The LHB packet is only used by the ZL50410 to reset the timeout counter, it is ignored otherwise (i.e. not passed on within the system). See the Failover Protection Application Note, ZLAN-43, for more information. 8.0 Port Trunking See Port Trunking application note, ZLAN-48, for more information. 8.1 Features and Restrictions A port group (i.e. trunk) can include up to 8 physical ports, all of the ports in a group can be in the same ZL50410 or in multiple ZL50410 to form a fault tolerant link. There are eight trunk groups total. Load distribution among the ports in a trunk for unicast is performed using hashing based on source MAC address and destination MAC address. Three other options include source MAC address only, destination MAC address only, and source port (in bidirectional ring mode only). Load distribution for multicast is performed similarly. If a VLAN includes any of the ports in a trunk group, all the ports in that trunk group should be in the same VLAN member map. The ZL50410 also provides a safe fail-over mode for port trunking automatically. If one of the ports in the trunking group goes down, the ZL50410 can redistribute the traffic over to the remaining ports in the trunk with software assistance. 8.2 Unicast Packet Forwarding The search engine finds the destination MCT entry, and if the status field says that the destination port found belongs to a trunk, then the trunk group number is retrieved. The source port of the packet is checked against the destination trunk group. If the source port belongs to the destination trunk group, the packet is discarded. A hash key, based on some combination of the source and destination MAC addresses for the current packet, selects the appropriate forwarding port, as specified in the Trunk_Hash registers. Each trunk has eight trunk_hash registers which selects one of the potential eight outgoing ports. The hash key provides a pseudo flow identifier which force the same flow to the same destination flow. As a result, the packet will always arrive in order. 8.3 Multicast Packet Forwarding For multicast packet forwarding, the device must determine the proper set of ports from which to transmit the packet based on the VLAN and hash key. Three functions are required in order to distribute multicast packets to the appropriate destination ports in a port trunking environment. • • • Determining the VLAN group it is forwarding port per group. The source port/group must be excluded from the forwarding. Select one port per trunk group to forward the packet to. This selection is based on hash key described in previous section. 48 Zarlink Semiconductor Inc. ZL50410 Data Sheet For example, port 0,1 and 2 belong to trunk group 0 and port 3 and 4 belong to trunk group 1. A single VLAN is established in this system with port 0,1,2,3,4,5 and 6 as the members in the VLAN. When a multicast packet is sent in from port 3, the ZL50410 select port 0,1,2,3,4,5 and 6 as potential destination based on the VLAN. Then port 3 and 4 are removed because they belong to the source port group (trunk group 1). Two ports from trunk group 0 will be removed based on the hash key. In this example, we assume port 0 and 1 are removed. As a result, port 2,5 and 6 are the only outgoing ports for this multicast packet. 9.0 Traffic Mirroring See Traffic Mirroring application note, ZLAN-50, for more information. 9.1 Mirroring Features Packets can be mirrored (duplicated) for network monitor purpose and/or network debug purpose. Three types of mirroring is available in ZL50410. 1. Source or Destination MAC address based 2. Flow based 3. Port based In source or destination mac address based mirroring, the “M” bit of the mirroring MAC address in the MCT is set. Also, the user need to specify the mirroring MAC address is source or destination of the packet. If source is selected, any packet received with the mirroring MAC address as source MAC address will be copied to the mirrored port. In the same way, if destination is selected, any packet received with mirroring MAC address as destination MAC address will be copied to the mirrored port. In flow based mirroring, a flow is established based on the source and destination mac address pair. When enabled, a packet with source and destination address match the pre-programmed source and destination mac address pair will be copied to the mirrored port. In reverse direction (source and destination match pre programmed destination and source), the flow can also be enabled and the frame will be copied to the mirrored port. In port based mirroring, traffic from any RMAC port can be mirrored to any RMAC port. The traffic from the source port can be either ingress or egress traffic. Up to two ports can be setup as mirrored ports. As a result, the traffic (both ingress and egress) of a specific port can be monitored by setting up both mirrored ports. Once a port is setup as mirrored port, it cannot be used for regular traffic. The mirrored port can be any port in the ZL50410. 9.2 Using port mirroring for loop back To perform remote loop back test, port mirroring can be used to bounce back the packet to the source port to check the data path. The CPU needs to setup the remote device through the command channel to enable port mirroring in the remote device. A CPU packet is send to the port in test in Device A. The packet will be forwarded to the test port, external cable, the destination port in Device B, and loop back to itself, back to the cable and go back to Device A and the CPU. This way, the whole channel can be tested. 49 Zarlink Semiconductor Inc. ZL50410 Data Sheet CPU DEVICE B DEVICE A Figure 12 - Remote Loopback Test 10.0 Clocks 10.1 Clock Requirements 10.1.1 System Clock (SCLK) speed requirement SCLK is the primary clock for the ZL50410 device. The speed requirement is based on the system configuration. Below is a table for a few configuration. Minimum SCLK speed required Configuration 8 Port 10/100M + 1 port 1000M 100 MHz 6-9 ports 10/100M 50 MHz 1-5 ports 10/100M 25 Mhz Table 12 - SCLK Speed Requirements 10.1.2 RMAC Reference Clock (M_CLK) speed requirement M_CLK is a 50 MHz clock used for the RMAC ports (ports 0-7) and CPU port (port 8). If none of the RMAC ports are configured in RMII mode or Reverse MII mode, a different clock frequency can be applied to M_CLK, as long as it's less than 50 MHz. In this case, register USD must be set to provide an internal 1usec timing. 10.1.3 GMAC Reference Clock (GREF_CLK) speed requirement GREF_CLK is a 125 MHz reference clock required for the GMAC port (port 9). If the device is in a 9 port 10/100 configuration only, GREF_CLK can be a lower frequency clock and can be connected to M_CLK to reduce the number of clock sources. If port 9 is not being used, GREF_CLK can be left unconnected. 10.1.4 JTAG Test Clock (TCK) speed requirements TCK is a clock used for the JTAG port. The frequency on this clock can vary. Refer to “JTAG (IEEE 1149.1-2001)” on page 135 for the frequency range. 50 Zarlink Semiconductor Inc. ZL50410 10.2 10.2.1 Data Sheet Clock Generation MDC MDC is used for the MII Management Interface and clocks data on MDIO. It is generated by the device from M_CLK and is equal to 500 kHz (M_CLK/100). If a different speed clock other than 50MHz is used on M_CLK, the USD register must be programmed to reset MDC. 10.2.2 SCL SCL is used for the I2C interface and clocks data on SDA. It is generated by the device from M_CLK and is equal to 50kHz (M_CLK/1000). If a different speed clock other than 50MHz is used on M_CLK, the USD register must be programmed to reset SCL. 10.2.3 Ethernet Interface Clocks If the RMAC ports are configured in Reverse MII mode, TXCLK and RXCLK are generated from M_CLK and are equal to M_CLK/2 for 100M mode or M_CLK/20 for 10M mode. M_CLK needs to be a 50 MHz clock in this mode. If the RMAC ports are configured in Reverse GPSI mode, TXCLK and RXCLK are generated from M_CLK and are equal to M_CLK/2 for 10M mode. M_CLK needs to be a 20 MHz clock in this mode and USD must be programmed accordingly. For the CPU port in serial+MII mode, TXCLK and RXCLK are generated from M_CLK and are equal to M_CLK/2 for 100M mode or M_CLK/20 for 10M mode. M_CLK needs to be a 50MHz clock in this mode. The gigabit port generates an external TXCLK interface clock in GMII mode. It is equal to the 125 MHz GREF_CLK. If the GMAC port is configured in Reverse MII mode, RXCLK is generated from GREF_CLK and is equal to GREF_CLK/2 for 100M mode (no support for 10M Reverse MII mode). GREF_CLK needs to be a 50 MHz clock in this mode. 51 Zarlink Semiconductor Inc. ZL50410 11.0 Hardware Statistics Counters 11.1 Hardware Statistics Counters List Data Sheet ZL50410 hardware provides a full set of statistics counters for each Ethernet port. The CPU accesses these counters through the CPU interface. All hardware counters are rollover counters. When a counter rolls over, the CPU is interrupted, so that long-term statistics may be kept. The MAC detects all statistics, except for the delay exceed discard counter (detected by buffer manager) and the filtering counter (detected by queue manager). The following is the wrapped signal sent to the CPU through the command block. 63 30 Other Status Bits 29 0 Status Wrapped Signal B[0] 0-d Bytes Sent (D) B[1] 1-L Unicast Frame Sent B[2] 1-U Frame Send Fail B[3] 2-I Flow Control Frames Sent B[4] 2-u Non-Unicast Frames Sent B[5] 3-d Bytes Received (Good and Bad) (D) B[6] 4-d Frames Received (Good and Bad) (D) B[7] 5-d Total Bytes Received (D) B[8] 6-L Total Frames Received B9] 6-U Flow Control Frames Received B[10] 7-l Multicast Frames Received B[11] 7-u Broadcast Frames Received B[12] 8-L Frames with Length of 64 Bytes B[13] 8-U Jabber Frames B[14] 9-L Frames with Length Between 65-127 Bytes B[15] 9-U Oversize Frames B[16] A-l Frames with Length Between 128-255 Bytes B[17] A-u Frames with Length Between 256-511 Bytes B[18] B-l Frames with Length Between 512-1023 Bytes B[19] B-u Frames with Length Between 1024-1528 Bytes 52 Zarlink Semiconductor Inc. ZL50410 B[20] C-l Fragments B[21] C-U1 Alignment Error B[22] C-U Undersize Frames B[23] D-l CRC B[24] D-u Short Event B[25] E-l Collision B[26] E-u Drop B[27] F-l Filtering Counter B[28] F-U1 Delay Exceed Discard Counter B[29] F-U Late Collision Notation: X-Y X: Address in the contain memory Y: Size and bits for the counter d: D Word counter L: 24 bits counter bit [23:0] U: 8 bits counter bit [31:24] U1: 8 bits counter bit [23:16] l: 16 bits counter bit [15:0] u: 16 bits counter bit [31:16] 53 Zarlink Semiconductor Inc. Data Sheet ZL50410 11.2 Data Sheet IEEE 802.3 HUB Management (RFC 1516) 11.2.1 Event Counters 11.2.1.1 ReadableOctet Counts number of bytes (i.e. octets) contained in good valid frames received. Frame size: > 64 bytes, < 1522 bytes if VLAN Tagged; (< 1518 bytes if not VLAN Tagged) (< BUF_LIMIT if enabled for this port) No FCS (i.e. checksum) error No collisions 11.2.1.2 ReadableFrame Counts number of good valid frames received. Frame size: > 64 bytes, < 1522 bytes if VLAN Tagged; (< 1518 bytes if not VLAN Tagged) (< BUF_LIMIT if enabled for this port) No FCS error No collisions 11.2.1.3 FCSErrors Counts number of valid frames received with bad FCS. Frame size: > 64 bytes, < 1522 bytes if VLAN Tagged; (< 1518 bytes if not VLAN Tagged) (< BUF_LIMIT if enabled for this port) No framing error No collisions 11.2.1.4 AlignmentErrors Counts number of valid frames received with bad alignment (not byte-aligned). Frame size: > 64 bytes, < 1522 bytes if VLAN Tagged; (< 1518 bytes if not VLAN Tagged) (< BUF_LIMIT if enabled for this port) No framing error No collisions 54 Zarlink Semiconductor Inc. ZL50410 11.2.1.5 Data Sheet FrameTooLongs Counts number of frames received with size exceeding the maximum allowable frame size. Frame size: > 64 bytes, > 1522 bytes if VLAN Tagged; (> 1518 bytes if not VLAN Tagged) (> BUF_LIMIT if enabled for this port) FCS error: don’t care Framing error: don’t care No collisions 11.2.1.6 ShortEvents Counts number of frames received with size less than the length of a short event. Frame size: < 10 bytes FCS error: don’t care Framing error: don’t care No collisions 11.2.1.7 Runts Counts number of frames received with size under 64 bytes, but greater than the length of a short event. Frame size: > 10 bytes, FCS error: don’t care Framing error: don’t care < 64 bytes No collisions 11.2.1.8 Collisions Counts number of collision events. Frame size: 11.2.1.9 any size LateEvents Counts number of collision events that occurred late (after LateEventThreshold = 64 bytes). Frame size: any size Events are also counted by collision counter 55 Zarlink Semiconductor Inc. ZL50410 11.2.1.10 Data Sheet VeryLongEvents Counts number of frames received with size larger than Jabber Lockup Protection Timer (TW3). Frame size: 11.2.1.11 > Jabber DataRateMisatches For repeaters or HUB application only. 11.2.1.12 AutoPartitions For repeaters or HUB application only. 11.2.1.13 TotalErrors Sum of the following errors: • • • • • • • FCSErrors AlignmentErrors FrameTooLong ShortEvents LateEvents VeryLongEvents DataRateMisatches 11.3 IEEE 802.1 Bridge Management (RFC 1286) 11.3.1 11.3.1.1 Event Counters InFrames Counts number of frames received by this port or segment. Note: A frame received by this port is only counted by this counter if and only if it is for a protocol being processed by the local bridge function. 11.3.1.2 OutFrames Counts number of frames transmitted by this port. Note: A frame transmitted by this port is only counted by this counter if and only if it is for a protocol being processed by the local bridge function. 11.3.1.3 InDiscards Counts number of valid frames received which were discarded (i.e., filtered) by the forwarding process. 11.3.1.4 DelayExceededDiscards Counts number of frames discarded due to excessive transmit delay through the bridge. 11.3.1.5 MtuExceededDiscards Counts number of frames discarded due to excessive size. 56 Zarlink Semiconductor Inc. ZL50410 11.4 Data Sheet RMON – Ethernet Statistic Group (RFC 1757) 11.4.1 11.4.1.1 Event Counters Drop Events Counts number of times a packet is dropped, because of lack of available resources. DOES NOT include all packet dropping -- for example, random early drop for quality of service support. 11.4.1.2 Octets Counts the total number of octets (i.e. bytes) in any frames received. 11.4.1.3 BroadcastPkts Counts the number of good frames received and forwarded with broadcast address. Does not include non-broadcast multicast frames. 11.4.1.4 MulticastPkts Counts the number of good frames received and forwarded with multicast address. Does not include broadcast frames. 11.4.1.5 CRCAlignErrors Counts number of frames received with FCS or alignment errors Frame size: > 64 bytes, < 1522 bytes if VLAN Tagged; (< 1518 bytes if not VLAN Tagged) (< BUF_LIMIT if enabled for this port) No collisions: 11.4.1.6 UndersizePkts Counts number of frames received with size less than 64 bytes. Frame size: < 64 bytes, No FCS error No framing error No collisions 57 Zarlink Semiconductor Inc. ZL50410 11.4.1.7 OversizePkts Counts number of frames received with size exceeding the maximum allowable frame size. Frame size: > 1522 bytes if VLAN Tagged; (> 1518 bytes if not VLAN Tagged) (> BUF_LIMIT if enabled for this port) FCS error don’t care Framing error don’t care No collisions 11.4.1.8 Fragments Counts number of frames received with size less than 64 bytes and with bad FCS. Frame size: < 64 bytes Framing error don’t care No collisions 11.4.1.9 Jabbers Counts number of frames received with size exceeding maximum frame size and with bad FCS. Frame size: > 1522 bytes if VLAN Tagged; (> 1518 bytes if not VLAN Tagged) (> BUF_LIMIT if enabled for this port) Framing error don’t care No collisions 58 Zarlink Semiconductor Inc. Data Sheet ZL50410 11.4.1.10 Data Sheet Collisions Counts number of collision events detected. Only a best estimate since collisions can only be detected while in transmit mode, but not while in receive mode. Frame size: 11.4.1.11 any size Packet Count for Different Size Groups Six different size groups – one counter for each: Pkts64Octets for any packet with size = 64 bytes Pkts65to127Octets for any packet with size from 65 bytes to 127 bytes Pkts128to255Octets or any packet with size from 128 bytes to 255 bytes Pkts256to511Octets for any packet with size from 256 bytes to 511 bytes Pkts512to1023Octets for any packet with size from 512 bytes to 1023 bytes Pkts1024to1518Octets for any packet with size from 1024 bytes to 1518 bytes (to 1522 with VLAN tag; to BUF_LIMIT if enabled for this port) Counts both good and bad packets. 11.5 Miscellaneous Counters In addition to the statistics groups defined in previous sections, the ZL50410 has other statistics counters for its own purposes. We have two counters for flow control – one counting the number of flow control frames received, and another counting the number of flow control frames sent. We also have two counters, one for unicast frames sent, and one for non-unicast frames sent. A broadcast or multicast frame qualifies as non-unicast. Furthermore, we have a counter called “frame send fail.” This keeps track of FIFO under-runs, late collisions, and collisions that have occurred 16 times. 59 Zarlink Semiconductor Inc. ZL50410 12.0 Register Definition 12.1 ZL50410 Register Description Register Data Sheet CPU Addr (Hex) Description R/W I²C Addr (Hex) Default 0. ETHERNET Port Control Registers (Substitute [n] with Port number (0..9)) ECR1Pn Port Control Register 1 for Port n 000+2n R/W 000+n 0C0 ECR2Pn Port Control Register 2 for Port n 001+2n R/W 00A+n 000 ECR3Pn Port Control Register 3 for Port n 080+2n R/W 014+n 000 ECR4Pn Port Control Register 4 for Port n 081+2n R/W 01E+n 018 BUF_LIMIT Frame Buffer Limit 036 R/W NA 040 FCC Flow Control Grant Period 037 R/W NA 003 1. VLAN Control Registers (Substitute [n] with Port number (0..9)) AVTCL VLAN Type Code Register Low 100 R/W 028 000 AVTCH VLAN Type Code Register High 101 R/W 029 081 PVMAPn_0 Port n Configuration Register 0 102+4n R/W 02A+n 0FF PVMAPn_1 Port n Configuration Register 1 103+4n R/W 034+n 0FF PVMAPn_3 Port n Configuration Register 3 105+4n R/W 03E+n 000 PVMODE VLAN Operating Mode 170 R/W 048 000 2. TRUNK Control Registers (Substitute [n] with Trunk Group number (0..7)) TRUNKn Trunk Group n 200+n R/W NA 000 TRUNKn_HASH10 Trunk Group n Hash 10 Destination Port 208+4n R/W NA 000 TRUNKn_HASH32 Trunk Group n Hash 32 Destination Port 209+4n R/W NA 000 TRUNKn_HASH54 Trunk Group n Hash 54 Destination Port 20A+4n R/W NA 000 TRUNKn_HASH76 Trunk Group n Hash 76 Destination Port 20B+4n R/W NA 000 Table 13 - Register Description 60 Zarlink Semiconductor Inc. Notes ZL50410 Register Description Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default PVLAN_Pn Private VLAN Edge (protected ports) Port n Egress Portmap 220+n R/W NA 000 MULTICAST_HASHn-0 Multicast hash result n mask byte 0 228+2n R/W NA 0FF MULTICAST_HASHn-1 Multicast hash result n mask byte 1 229+2n R/W NA 0FF Notes 3. CPU Port Configuration MAC0 CPU MAC Address byte 0 300 R/W NA 000 MAC1 CPU MAC Address byte 1 301 R/W NA 000 MAC2 CPU MAC Address byte 2 302 R/W NA 000 MAC3 CPU MAC Address byte 3 303 R/W NA 000 MAC4 CPU MAC Address byte 4 304 R/W NA 000 MAC5 CPU MAC Address byte 5 305 R/W NA 000 INT_MASK0 Interrupt Mask 0 306 R/W NA 000 INTP_MASKn Interrupt Mask for MAC Port 2n, 2n+1 310+n R/W NA 000 RQS Receive Queue Select 323 R/W NA 000 RQSS Receive Queue Status 324 RO NA NA MAC01 Increment MAC port 0,1 address 325 R/W NA 000 MAC23 Increment MAC port 2,3 address 326 R/W NA 000 MAC45 Increment MAC port 4,5 address 327 R/W NA 000 MAC67 Increment MAC port 6,7 address 328 R/W NA 000 MAC9 Port 9 MAC address byte 5 329 R/W NA 000 CPUQINS[6:0] 330-336 R/W NA 000 CPUQINSRPT 337 RO NA NA CPUGRNHDL[1:0] 338-339 RO NA NA CPURLSINFO[4:0] 33A-33E R/W NA 000 33F R/W NA 000 400 R/W 049 05C CPUGRNCTR 4. Search Engine Configurations AGETIME_LOW MAC Address Aging Time Low Table 13 - Register Description (continued) 61 Zarlink Semiconductor Inc. (n=0..4) ZL50410 Register Description Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default AGETIME_HIGH MAC Address Aging Time High 401 R/W 04A 000 SE_OPMODE Search Engine Operating Mode 403 R/W NA 000 QOSC QOS Control 500 R/W 04B 000 UCC Unicast Congestion Control 510 R/W 068 006 MCC Multicast Congestion Control 511 R/W 069 006 MCCTH Multicast Congestion Threshold 512 R/W NA 003 RDRC0 WRED Drop Rate Control 0 513 R/W 090 000 RDRC1 WRED Drop Rate Control 1 514 R/W 091 000 RDRC2 WRED Drop Rate Control 2 515 R/W NA 000 SFCB Share FCB Size 518 R/W 074 000 C1RS Class 1 Reserve Size 519 R/W 075 000 C2RS Class 2 Reserve Size 51A R/W 076 000 C3RS Class 3 Reserve Size 51B R/W 077 000 AVPML VLAN Priority Map Low 530 R/W 056 000 AVPMM VLAN Priority Map Middle 531 R/W 057 000 AVPMH VLAN Priority Map High 532 R/W 058 000 AVDM VLAN Discard Map 533 R/W 05C 000 TOSPML TOS Priority Map Low 540 R/W 059 000 TOSPMM TOS Priority Map Middle 541 R/W 05A 000 TOSPMH TOS Priority Map High 542 R/W 05B 000 TOSDML TOS Discard Map 543 R/W 05D 000 USER_PROTOCOL_n User Define Protocol n 550+n R/W 0B3+n 000 USER_PROTOCOL_ FORCE_DISCARD User Define Protocol 0 To 7 Force Discard Enable 558 R/W 0BB 000 WLPP10 Well Known Logic Port 0 and 1 Priority 560 R/W 0A8 000 Notes 5. Global QOS Control Table 13 - Register Description (continued) 62 Zarlink Semiconductor Inc. (n=0..7) ZL50410 Register Description Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default WLPP32 Well Known Logic Port 2 and 3 Priority 561 R/W 0A9 000 WLPP54 Well Known Logic Port 4 and 5 Priority 562 R/W 0AA 000 WLPP76 Well Known Logic Port 6 and 7 Priority 563 R/W 0AB 000 WLPE Well Known Logic Port 0 To 7 Enable 564 R/W 0AC 000 WLPFD Well Known Logic Port 0 To 7 Force Discard Enable 565 R/W 0AD 000 USER_PORTn_LOW User Define Logical Port n Low 570+2n R/W 092+n 000 USER_PORTn_HIGH User Define Logical Port n High 571+2n R/W 09A+n 000 USER_PORT1:0_ PRIORITY User Define Logic Port 0 and 1 Priority 590 R/W 0A2 000 USER_PORT3:2_ PRIORITY User Define Logic Port 2 and 3 Priority 591 R/W 0A3 000 USER_PORT5:4_ PRIORITY User Define Logic Port 4 and 5 Priority 592 R/W 0A4 000 USER_PORT7:6_ PRI ORITY User Define Logic Port 6 and 7 Priority 593 R/W 0A5 000 USER_PORT_ ENABLE[7:0] User Define Logic Port 0 To 7 Enable 594 R/W 0A6 000 USER_PORT_ FORCE_DISCARD[7:0] User Define Logic Port 0 To 7 Force Discard Enable 595 R/W 0A7 000 RLOWL User Define Range Low Bit [7:0] 5A0 R/W 0AE 000 RLOWH User Define Range Low Bit [15:8] 5A1 R/W 0AF 000 RHIGHL User Define Range High Bit [7:0] 5A2 R/W 0B0 000 RHIGHH User Define Range High Bit [15:8] 5A3 R/W 0B1 000 RPRIORITY User Define Range Priority 5A4 R/W 0B2 000 6. MISC Configuration Register MII_OP0 MII Register Option 0 600 R/W 0BC 000 MII_OP1 MII Register Option 1 601 R/W 0BD 000 Table 13 - Register Description (continued) 63 Zarlink Semiconductor Inc. Notes (n=0..7) ZL50410 Register Description Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default FEN Feature Registers 602 R/W 0BE 010 MIIC0 MII Command Register 0 603 R/W NA 000 MIIC1 MII Command Register 1 604 R/W NA 000 MIIC2 MII Command Register 2 605 R/W NA 000 MIIC3 MII Command Register 3 606 R/W NA 000 MIID0 MII Data Register 0 607 RO NA NA MIID1 MII Data Register 1 608 RO NA NA USD One micro second divider 609 R/W NA 000 DEVICE Device id and test 60A R/W NA 002 SUM EEPROM Checksum Register 60B R/W 0FF 000 LHBTimer Link heart beat time out timer 610 R/W NA 000 LHBReg0 LHB control field value[7:0] 611 R/W NA 000 LHBReg1 LHB control field value [15:8] 612 R/W NA 000 fMACCReg0 Forced MAC control field value [7:0] 613 R/W NA 000 fMACCReg1 Forced MAC control field value [15:8] 614 R/W NA 000 FCB_BASE_ADDR0 FCB Base Address Register 0 620 R/W 0BF 000 FCB_BASE_ADDR1 FCB Base Address Register 1 621 R/W 0C0 060 FCB_BASE_ADDR2 FCB Base Address Register 2 622 R/W 0C1 000 7. Port Mirroring Controls MIRROR_DEST_MAC0 Mirror Destination MAC Address 0 700 R/W NA 000 MIRROR_DEST_MAC1 Mirror Destination MAC Address 1 701 R/W NA 000 MIRROR_DEST_MAC2 Mirror Destination MAC Address 2 702 R/W NA 000 MIRROR_DEST_MAC3 Mirror Destination MAC Address 3 703 R/W NA 000 MIRROR_DEST_MAC4 Mirror Destination MAC Address 4 704 R/W NA 000 Table 13 - Register Description (continued) 64 Zarlink Semiconductor Inc. Notes ZL50410 Register Description Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default MIRROR_DEST_MAC5 Mirror Destination MAC Address 5 705 R/W NA 000 MIRROR_SRC_MAC0 Mirror Source MAC Address 0 706 R/W NA 000 MIRROR_SRC_MAC1 Mirror Source MAC Address 1 707 R/W NA 000 MIRROR_SRC_MAC2 Mirror Source MAC Address 2 708 R/W NA 000 MIRROR_SRC_MAC3 Mirror Source MAC Address 3 709 R/W NA 000 MIRROR_SRC_MAC4 Mirror Source MAC Address 4 70A R/W NA 000 MIRROR_SRC_MAC5 Mirror Source MAC Address 5 70B R/W NA 000 MIRROR_CONTROL Port Mirror Control Register 70C R/W NA 000 RMAC_MIRROR0 RMAC Mirror 0 710 R/W NA 000 RMAC_MIRROR1 RMAC Mirror 1 711 R/W NA 000 Notes 8. Per Port QOS Control FCRn Flooding Control Register n 800+n R/W 04C+n 000 BMRCn Broadcast/Multicast Rate Control n 820+n R/W 05E+n 000 PR100_n Port Reservation for RMAC Ports (n=0..7) 840+n R/W 06A+n 006 ‘d1536/1 6=‘d96, ‘d96>>4= ’h6 PR100_CPU Port Reservation for CPU Port 848 R/W 073 006 ‘d96 PRG Port Reservation for GMAC Port 849 R/W 072 024 ‘d96x6=‘ d576, ‘d576>>4 =’h24 PTH100_n Port Threshold for RMAC Ports (n=0..7) 860+n R/W 0C2+n 003 ½ PTH100_CPU Port Threshold for CPU Port 868 R/W 0CB 003 ½ PTHG Port Threshold for GMAC Port 869 R/W 0CA 012 ½ Table 13 - Register Description (continued) 65 Zarlink Semiconductor Inc. (n=0..9) ZL50410 Register QOSCn Description QOS Control n Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default Notes 880+n R/W 078-08F 000 (n=0..39) NA E. System Diagnostic DTSRL Test Register Low E00 R/W NA 000 DTSRM Test Register Medium E01 R/W NA 001 TESTOUT0 Testmux Output [7:0] E02 R/O NA NA TESTOUT1 Testmux Output [15:8] E03 R/O NA NA MASK0 MASK Timeout 0 E10 R/W 0F6 000 MASK1 MASK Timeout 1 E11 R/W 0F7 000 MASK2 MASK Timeout 2 E12 R/W 0F8 000 MASK3 MASK Timeout 3 E13 R/W 0F9 000 MASK4 MASK Timeout 4 E14 R/W 0FA 000 BOOTSTRAP[2:0] BOOTSTRAP Read Back E80-E82 RO NA NA PRTFSMSTn Ethernet Port n Status Read Back E90+n RO NA NA (n=0..9) PRTQOSSTn RMAC Port n QOS and Queue Status EA0+n RO NA NA (n=0..7) PRTQOSST8A CPU Port QOS and Queue Status A EA8 RO NA NA PRTQOSST8B CPU Port QOS and Queue Status B EA9 RO NA NA PRTQOSST9A GMAC Port QOS and Queue Status A EAA RO NA NA PRTQUSST9B GMAC Port QOS and Queue Status B EAB RO NA NA CLASSQOSST Class Buffer Status EAC RO NA NA PRTINTCTR Buffer Interrupt Status EAD R/W NA 000 QMCTRLn Ports Queue Control Status EB0+n R/W NA 000 QCTRL Ports Queue Control EBA R/W NA 000 BMBISTR0 Memory bist result EBB R/O NA NA BMBISTR1 Memory bist result EBC R/O NA NA BMControl Memory control EBD R/W NA 00F BUFF_RST Buffer Reset Pool EC0 R/W NA 000 FCBHEADPTR0 FCB Head Pointer [7:0] EC1 R/W NA 000 Table 13 - Register Description (continued) 66 Zarlink Semiconductor Inc. (n=0..9) ZL50410 Register Description Data Sheet CPU Addr (Hex) R/W I²C Addr (Hex) Default FCB_HEAD_PTR1 FCB Head Pointer [15:8] EC2 R/W NA 000 FCB_TAIL_PTR0 FCB Tail Pointer [7:0] EC3 R/W NA 000 FCB_TAIL_PTR1 FCB Tail Pointer [15:8] EC4 R/W NA 000 FCB_NUM0 FCB Number [7:0] EC5 R/W NA 000 FCB_NUM1 FCB Init Start and FCB Number [14:8] EC6 R/W NA 006 BM_RLSFF_CTRL Read control register EC7 R/W NA 000 BM_RLSFF_INFO0 Bm_rlsfifo_info[7:0] EC8 RO NA NA BM_RLSFF_INFO1 Bm_rlsfifo_info[15:8] EC9 RO NA NA BM_RLSFF_INFO2 Bm_rlsfifo_info[23:16] ECA RO NA NA BM_RLSFF_INFO3 Bm_rlsfifo_info[31:24] ECB RO NA NA BM_RLSFF_INFO4 Bm_rlsfifo_info[39:32] ECC RO NA NA BM_RLSFF_INFO5 Fifo_cnt[2:0],Bm_rlsfifo_inf o[44:40] ECD RO NA NA GCR Global Control Register F00 R/W NA 000 DCR Device Control Register F01 RO NA NA DCR1 Device Control Register 1 F02 RO NA NA DPST Device Port Status Register F03 R/W NA 000 DTST Data read back register F04 RO NA NA DA DA Register FFF RO NA 0DA F. System Control Table 13 - Register Description (continued) 12.2 12.2.1 • • INDEX_REG0 Address for indirectly accessed register addresses (8/16 bits) Address = 0 (write only) • In 16-bit or serial mode: Address bits [15:0] • In 8-bit mode: Address bits [7:0] 12.2.2 • • Directly Accessed Registers INDEX_REG1 (only needed for 8-bit mode) Address for indirectly accessed register addresses (8 bits) Address = 1 (write only) • In 16-bit or serial mode: NA • In 8-bit mode: Address bits [15:8] 67 Zarlink Semiconductor Inc. Notes ZL50410 12.2.3 • • DATA_FRAME_REG Data of indirectly accessed registers (8 bits) Address = 2 (read/write) 12.2.4 • • • Data Sheet CONTROL_FRAME_REG CPU transmit/receive switch frames (8/16 bits) Address = 3 (read/write) Format: 8-byte of Frame status (Frame size, Source port #, VLAN tag) Frame Data (size should be in multiple of 8-byte) 12.2.5 • • • • COMMAND&STATUS Register CPU interface commands and status (8 bits) Address = 4 (read/write) When the CPU writes to this register Bit [0]: Set Control Frame Receive buffer ready, after CPU writes a complete frame into the buffer. This bit is self-cleared. Bit [1]: Set Control Frame Transmit buffer1 ready, after CPU reads out a complete frame from the buffer. This bit is self-cleared. Bit [2]: Set Control Frame Transmit buffer2 ready, after CPU reads out a complete frame from the buffer. This bit is self-cleared. Bit [3]: Set this bit to indicate CPU received a whole frame (transmit FIFO frame receive done), and flushed the rest of frame fragment, If occurs. This bit will be self-cleared. Bit [4]: Set this bit to indicate that the following Write to the Receive FIFO is the last one (EOF). This bit will be self-cleared. Bit [5]: Set this bit to re-start the data that is sent from the CPU to Receive FIFO (re-align). This feature can be used for software debug. For normal operation must be '0'. Bits [7:6]: Reserved. Must be '0' When the CPU reads this register: Bit [0]: Control Frame receive buffer ready, CPU can write a new frame 1 – CPU can write a new control command 1 0 – CPU has to wait until this bit is 1 to write a new control command 1 Bit [1]: Control Frame transmit buffer1 ready for CPU to read 1 – CPU can read a new control command 1 0 – CPU has to wait until this bit is 1 to read a new control command Bit [2]: Control Frame transmit buffer2 ready for CPU to read 1 – CPU can read a new control command 1 0 – CPU has to wait until this bit is 1 to read a new control command Bit [3]: Transmit FIFO has data for CPU to read (TXFIFO_RDY) Bit [4]: Receive FIFO has space for incoming CPU frame (RXFIFO_SPOK) Bit [5]: Transmit FIFO End Of Frame (TXFIFO_EOF) Bits [7:6]: Reserved 68 Zarlink Semiconductor Inc. ZL50410 12.2.6 • • Data Sheet Interrupt Register Interrupt sources (8 bits) Address = 5 (read/write) Bit [0]: CPU frame interrupt Bit [1]: Control Frame 1 interrupt. Control Frame receive buffer1 has data for CPU to read Bit [2]: Control Frame 2 interrupt. Control Frame receive buffer2 has data for CPU to read Bits [6:3]: Reserved Bit [7]: Device Timeout Detected interrupt Note: This bit is not self-cleared. After reading, the CPU has to clear the bit writing 0 to it. 12.2.7 • • • Control Command Frame Buffer1 Access Register CPU transmit/receive control frames (8/16 bits) Address = 6 (read/write) When CPU writes to this register: Data is written to the Control Command Frame Receive Buffer • When CPU reads this register: Data is read from the Control Command Frame Transmit Buffer1 12.2.8 • • • Control Command Frame Buffer2 Access Register CPU receive control frames (8/16 bits) Address = 7 (read only) When CPU reads this register: Data is read from the Control Command Frame Transmit Buffer2 12.3 Indirectly Accessed Registers 12.3.1 12.3.1.1 (Group 0 Address) MAC Ports Group ECR1Pn: Port n Control Register I²C Address 000+n; CPU Address:0000+2n (n = port number) Accessed by CPU and I²C (R/W) Port 0 – 7 & 9: (RMAC & GMAC Ports) Bit [0] Flow Control 0 - Enable (Default) 1 - Disable Bit [1] Duplex Mode 0 - Full Duplex (Default) 1 - Half Duplex - Only in 10/100 mode Bit [2] Speed 0 - 100 Mbps (Default) 1 - 10 Mbps 69 Zarlink Semiconductor Inc. ZL50410 Bits [4:3] 00 - Enable Auto-Negotiation (Default) This enables hardware state machine for auto-negotiation. 01 - Limited Disable Auto-Negotiation This disables hardware state machine for speed auto-negotiation (use ECR1Pn[2:0] for configuration). Hardware will still poll PHY for link status. 10 - Force Link Down Disable the port. Hardware does not talk to PHY. 11 - Force Link Up The configuration in ECR1Pn[2:0] is used for (speed/duplex/flow control) setup. Hardware does not talk to PHY. Bit [5] Asymmetric Flow Control Enable. 0 – Disable asymmetric flow control (Default) 1 – Enable Asymmetric flow control Data Sheet When this bit is set and flow control is on (bit [0] = 0), the device does not send out flow control frames, but it’s receiver interprets and processes flow control frames. Bits [7:6] SS - Spanning tree state (IEEE 802.1D spanning tree protocol) 00 - Blocking: Frame is dropped 01 - Listening: Frame is dropped 10 - Learning: Frame is dropped. Source MAC address is learned. 11 - Forwarding: Frame is forwarded. Source MAC address is learned. (Default) Port 8: (CPU Port) 8/16-bit or Serial Only Modes Bit [5:0] Reserved Bits [7:6] SS - Spanning tree state (IEEE 802.1D spanning tree protocol) 00 - Blocking: Frame is dropped 01 - Listening: Frame is dropped 10 - Learning: Frame is dropped. Source MAC address is learned. 11 - Forwarding: Frame is forwarded. Source MAC address is learned. (Default) Serial + MII Mode Bit [0] Flow Control 0 - Enable (Default) 1 - Disable Bit [1] Duplex Mode Must be 0 - Full Duplex (Default) Bit [2] Speed 0 - 100 Mbps (Default) 1 - 10 Mbps Bit [3] 1 - MII Port Up The configuration in ECR1Pn[2:0] is used for (speed/duplex/flow control) setup. 0 - MII Port Down Note: Bit [4] must be ‘1’. Bit [4] Must be ‘1’. 70 Zarlink Semiconductor Inc. ZL50410 Bit [5] Data Sheet Asymmetric Flow Control Enable. 0 – Disable asymmetric flow control (Default) 1 – Enable Asymmetric flow control When this bit is set and flow control is on (bit [0] = 0), the device does not send out flow control frames, but it’s receiver interprets and processes flow control frames. Bits [7:6] 12.3.1.2 SS - Spanning tree state (IEEE 802.1D spanning tree protocol) 00 - Blocking: Frame is dropped 01 - Listening: Frame is dropped 10 - Learning: Frame is dropped. Source MAC address is learned. 11 - Forwarding: Frame is forwarded. Source MAC address is learned. (Default) ECR2Pn: Port n Control Register I²C Address: 00A+n; CPU Address:0001+2n (n = port number) Accessed by CPU and I²C (R/W) Bit [0]: Filter untagged frame 0: Disable (Default) 1: All untagged frames from this port are discarded or follow security option when security is enable Bit [1]: Filter Tag frame 0: Disable (Default) 1: All tagged frames from this port are discarded or follow security option when security is enable Bit [2]: Learning Disable 0: Learning is enabled on this port (Default) 1: Learning is disabled on this port Bit [3]: Rate control timer select (RMAC ports only) 0: 10 microsecond refreshing time (Default) 1: 1 millisecond refreshing time Bit [4] Force VLAN Tag Out 0: Disable (Default) 1: Enable If this feature is enabled, a packet leaving the device will ALWAYS have a VLAN tag. Only applicable in tagged-based VLAN mode (PVMODE[0]=’1’). In port-based VLAN mode (PVMODE[0]=’0’), this bit must be 0. Bit [5] Do not change VLAN tag. This overrides PVMAPnn_3 bit [2]. If this bit is set, no tag will be replaced nor removed. 0: Disable (Default) 1: Enable 71 Zarlink Semiconductor Inc. ZL50410 Bits [7:6] Data Sheet Security Enable. The ZL50410 checks the incoming data for one of the following conditions: • If the source MAC address of the incoming packet is in the MAC table and is defined as secure address but the ingress port is not the same as the port associated with the MAC address in the MAC table. • A MAC address is defined as secure when its entry at MAC table has static status and bit 0 is set to 1. MAC address bit 0 (the first bit transmitted) indicates whether the address is unicast or multicast. As source addresses are always unicast bit 0 is not used (always 0). ZL50410 uses this bit to define secure MAC addresses. • If the port is set as learning disable and the source MAC address of the incoming packet is not defined in the MAC address table or the MAC address is not associated to the ingress port. If any one of the conditions is met, the packet is forwarded based on these setting. 00 – Disable port security, forward packets as usual. (Default) 01 – Discard violating packets 10 – Forward violating packets as usual and also to the CPU for inspection 11 – Forward violating packets to the CPU for inspection It also checks for one of the following additional conditions: • If the port is configured to filter untagged frames and an untagged frame arrives, or • If the port is configured to filter tagged frames and a tagged frame arrives, or • If the packet has the source mac address on the source mac address filter list, or • If the packet has the destination mac address on the destination mac address filter list If any one of the conditions is met, the packet will be handled according to: 0X – Discard violating packets 1X – Forward violating packets to CPU for inspection 12.3.1.3 ECR3Pn: Port n Control Register I²C Address: 014+n; CPU Address:0080+2n (n = port number) Accessed by CPU and I²C (R/W) Bit [0]: Enable receiving short frame < 64B 0: Disable (Default) 1: Allow receiving short frame with correct CRC. Bit [1]: Enable receiving long frame > 1522 0: Disable (Default) 1: Allow receiving long frame that are <= BUF_LIMIT value Bit [2]: Enable pad frame to 64B when transmitted 0: Allow padding to 64B (Default) 1: Disable Bit [3]: Enable compress preamble 0: Send standard preamble (Default) 1: Only one byte preamble+SFD Bits [6:4] Number of bytes removed from the Inter-Frame Gap (IFG). (Default 0x0) 72 Zarlink Semiconductor Inc. ZL50410 Bit [7] 12.3.1.4 Data Sheet Link Heart Beat Transmit (RMAC ports only) 0: Disable (Default) 1: Enable ECR4Pn: Port n Control Register I²C Address: 01E+n; CPU Address:0081+2n (n = port number) Accessed by CPU and I²C (R/W) Port 0 – 7: (RMAC Ports) Bit [0]: Enable TXCLK output. Active high 0: Disable (Default) 1: Mn_TXCLK pin becomes output in GPSI or MII mode Bit [1]: Enable RXCLK output. Active high 0: Disable (Default) 1: Mn_RXCLK pin becomes output in GPSI or MII mode Bit [2]: Internal loopback. 0: Disable (Default) 1: Enable In this mode, the packet is looped back in the MAC layer before going out of the chip. You must force linkup at full duplex as well. External loopback is another level of system diagnostic which involves the PHY device to loopback the packet. Bits [4:3]: Interface mode: 00 - GPSI mode 01 - MII mode 10 - Reserved 11 - RMII mode (Default) Bit [5]: Frame loopback. 0: Disable frame from sending back to its source port. (Default) 1: Allow frame to send back to its source port In a regular ethernet switch, a packet should never be receive and forwarded to the same port. Setting the bit allows it to happen. This is not the same as an ingress MAC loopback. The destination MAC address has to be stored (learned) in the MCT and associated with the originating source port. The frame loopback will only work for unicast packets. Bit [6]: Link Heart Beat Receive 0: Disable (Default). Also clears all MAC LHB status. 1: Enable Bit [7]: Soft reset. 0: Normal operation (Default) 1: Reset. Not self clearing. 73 Zarlink Semiconductor Inc. ZL50410 Data Sheet Port 8: (CPU Port) Bits [1:0]: Reserved Bit [2]: Enable special write to 2 registers in a single write operation. 0: Disable (Default) 1: Enable Should be enabled only in serial mode and disabled in 8/16-bit mode. Bits [4:3]: Enable insertion of 2-byte CPU information in CPU frame packet in Serial + MII mode 00: No information is inserted 01: Insert 2-byte of CPU information 10: Reserved 11: Insert 6-byte of padding + 2-byte of CPU information (Default) In port-based VLAN mode, the CPU MII interface must be in “No information is inserted” mode (ECR4P8[4:3]='00'). In tagged-based VLAN mode, the CPU MII interface supports all three modes (0,2,8 bytes insertion). Bit [5]: Frame loopback. 0: Disable frame from sending back to its source port. (Default) 1: Allow frame to send back to its source port In a regular ethernet switch, a packet should never be receive and forwarded to the same port. Setting the bit allows it to happen. This is not the same as an ingress MAC loopback. The destination MAC address has to be stored (learned) in the MCT and associated with the originating source port. The frame loopback will only work for unicast packets. Bit [6]: Reserved Bit [7]: Soft reset. 0: Normal operation (Default) 1: Reset. Not self clearing. Port 9: (GMAC Port) Bit [0]: Reserved Bit [1]: Enable RXCLK output. Active high 0: Disable (Default) 1: M9_RXCLK pin becomes output in MII mode Note: To configure port 9 with the device providing the interface clocks, you need to tie M9_RXCLK to M9_MTXCLK externally as M9_MTXCLK is not a bidirectional clock. 74 Zarlink Semiconductor Inc. ZL50410 Bit [2]: Data Sheet Internal loopback. 0: Disable (Default) 1: Enable In this mode, the packet is looped back in the MAC layer before going out of the chip. You must force linkup at full duplex as well. External loopback is another level of system diagnostic which involves the PHY device to loopback the packet. Bits [4:3]: Interface mode: 00 - MII mode 11 - GMII mode (Default) Bit [5]: Frame loopback. 0: Disable frame from sending back to its source port. (Default) 1: Allow frame to send back to its source port In a regular ethernet switch, a packet should never be receive and forwarded to the same port. Setting the bit allows it to happen. This is not the same as an ingress MAC loopback. The destination MAC address has to be stored (learned) in the MCT and associated with the originating source port. The frame loopback will only work for unicast packets. 12.3.1.5 Bit [6]: Reserved Bit [7]: Soft reset. 0: Normal operation (Default) 1: Reset. Not self clearing. BUF_LIMIT – Frame Buffer Limit CPU Address:h036 Accessed by CPU (R/W) 12.3.1.6 Bits [6:0]: Frame Buffer Limit (max 4 KB). Multiple of 64 bytes (Default 0x40) Bit [7]: Reserved FCC – Flow Control Grant Period CPU Address:h037 Accessed by CPU (R/W) Bits [2:0]: Flow Control Grant Period (Default 0x3) Bits [7:3]: Reserved 75 Zarlink Semiconductor Inc. ZL50410 12.3.2 12.3.2.1 Data Sheet (Group 1 Address) VLAN Group AVTCL – VLAN Type Code Register Low I²C Address 028; CPU Address:h100 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.2.2 VLANType_LOW: Lower 8 bits of the VLAN type code (Default 0x00) AVTCH – VLAN Type Code Register High I²C Address 029; CPU Address:h101 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.2.3 VLANType_HIGH: Upper 8 bits of the VLAN type code (Default is 0x81) PVMAP00_0 – Port 0 Configuration Register 0 I²C Address 02A, CPU Address:h102 Accessed by CPU and I²C (R/W) In Port Based VLAN Mode Bits [7:0]: VLAN Mask for port 0 (Default 0xFF) This register indicates the legal egress ports. A “1” on bit 3 means that the packet can be sent to port 3. A “0” on bit 3 means that any packet destined to port 3 will be discarded. This register works with registers 1 to form a 10 bit mask to all egress ports. In Tag based VLAN Mode Bits [7:0]: PVID [7:0] (Default is 0xFF) This is the default VLAN tag. It works with configuration register PVMAP00_1 [7:5] [3:0] to form a default VLAN tag. If the received packet is untagged, then the packet is classified with the default VLAN tag. If the received packet has a VLAN ID of 0, then PVID is used to replace the packet’s VLAN ID. 12.3.2.4 PVMAP00_1 – Port 0 Configuration Register 1 I²C Address h34, CPU Address:h103 Accessed by CPU and I²C (R/W) In Port based VLAN Mode Bits [1:0]: VLAN Mask for ports 9 to 8 (Default 0x3) Bits [7:2]: Reserved (Default 0x3F) 76 Zarlink Semiconductor Inc. ZL50410 Data Sheet In Tag based VLAN Mode 12.3.2.5 Bits [3:0]: PVID [11:8] (Default is 0xF) Bit [4]: Untrusted Port. This register is used to change the VLAN priority field of a packet to a predetermined priority. 1: VLAN priority field is changed to Bit [7:5] at ingress port (Default) 0: Keep VLAN priority field Bits [7:5]: Untag Port Priority (Default 0x7) PVMAP00_3 – Port 0 Configuration Register 3 I²C Address h3E, CPU Address:h105 Accessed by CPU and I²C (R/W) In Port Based VLAN Mode Bits [2:0]: Reserved Bits [5:3]: Default Transmit priority. Used when Bit [7]=1 (Default 0) Transmit Priority Level 0 (Lowest) Transmit Priority Level 1 Transmit Priority Level 2 Transmit Priority Level 3 (Highest) Bit [6]: Default Discard priority. Used when Bit [7]=1 0 – Discard Priority Level 0 (Lowest) (Default) 1 – Discard Priority Level 1(Highest) Bit [7]: Enable Fix Priority (Default 0) 0 - Disable. All frames are analysed. Transmit Priority and Discard Priority are based on VLAN Tag, TOS or Logical Port. 1 - Enable. Transmit Priority and Discard Priority are based on values programmed in bit [6:3] In Tag-based VLAN Mode Bit [0]: Not used Bit [1]: Ingress Filter Enable 0 - Disable Ingress Filter. Packets with VLAN not belonging to source port are forwarded, if destination port belongs to the VLAN. Symmetric VLAN. (Default) 1 - Enable Ingress Filter. Packets with VLAN not belonging to source port are filtered. Asymmetric VLAN. Bit [2]: Force untag out (VLAN tagging is based on IEEE 802.1Q rule). 0 - Disable (Default) 1 - Force untagged output. All packets transmitted from this port are untagged. This bit is used when this port is connected to legacy equipment that does not support VLAN tagging. 77 Zarlink Semiconductor Inc. ZL50410 Bits [5:3]: Data Sheet Default Transmit priority. Used when Bit [7]=1 (Default 0) Transmit Priority Level 0 (Lowest) Transmit Priority Level 1 Transmit Priority Level 2 Transmit Priority Level 3 (Highest) 12.3.2.6 Bit [6]: Default Discard priority. Used when Bit [7]=1 0 – Discard Priority Level 0 (Lowest) (Default) 1 – Discard Priority Level 1(Highest) Bit [7]: Enable Fix Priority (Default 0) 0 - Disable. All frames are analysed. Transmit Priority and Discard Priority are based on VLAN Tag, TOS or Logical Port. 1 - Enable. Transmit Priority and Discard Priority are based on values programmed in bit [6:3] PVMAPnn_0,1,3 – Ports 1~9 Configuration Registers PVMAP01_0,1,3 I²C Address h2B,35,3F; CPU Address:h106,107,109 (Port 1) PVMAP02_0,1,3 I²C Address h2C,36,40; CPU Address:h10A, 10B, 10D (Port 2) PVMAP03_0,1,3 I²C Address h2D,37,41; CPU Address:h10E, 10F, 111 (Port 3) PVMAP04_0,1,3 I²C Address h2E,38,42; CPU Address:h112, 113, 115 (Port 4) PVMAP05_0,1,3 I²C Address h2F,39,43; CPU Address:h116, 117, 119 (Port 5) PVMAP06_0,1,3 I²C Address h30,3A,44; CPU Address:h11A, 11B, 11D (Port 6) PVMAP07_0,1,3 I²C Address h31,3B,45; CPU Address:h11E, 11F, 121 (Port 7) PVMAP08_0,1,3 I²C Address h32,3C,46; CPU Address:h122, 123, 125 (Port CPU) PVMAP09_0,1,3 I²C Address h33,3D,47; CPU Address:h126, 127, 129 (Port GMAC) 12.3.2.7 PVMODE I²C Address: h048, CPU Address:h170 Accessed by CPU and I²C (R/W) Bit [0]: VLAN Mode 0: Port based VLAN Mode (Default) 1: Tag based VLAN Mode Bit [1]: Slow learning (Default = 0) Same function as SE_OPMODE bit [7]. Either bit can enable the function; both need to be turned off to disable the feature. Bit [2]: Disable dropping of frames with destination MAC addresses 01-80-C2-00-00-01 to 0x01-80-C2-00-00-0F. 0: Drop all frames in this range (Default) 1: Disable dropping of frames in this range 78 Zarlink Semiconductor Inc. ZL50410 Data Sheet Bit [3]: Flooding control in secure mode 0: Enable - Learning disabled port will not receive any flooding packets (Default) 1: Disable Bit [4]: Support MAC address 0 0: MAC address 0 is not learned. (Default) This means packet with destination MAC address 0 is forwarded as unknown destination. It is subjected to unicast to multicast rate control. 1: MAC address 0 is learned. Bit [5]: Disable IEEE multicast control frame (01-80-C2-00-00-00 to 01-80-C2-00-00-FF) to CPU in managed mode. In unmanaged mode, frame is forwarded as multicast (except PAUSE frame). 0: Frame is forwarded to CPU (Default) 1: Frame is forwarded as multicast (except PAUSE frame) Bit [6]: IP Multicast Enable 0: Disable (default) 1: Enable In general, this bit is equal to ^FEN[4]. Bit [7]: 12.3.3 Enable logical port match in secure mode 0: Disable (Default) 1: Enable - When Well Known or User Define logical port force discard enabled, force any IP packet with logical port number matching logical port numbers to CPU. (Group 2 Address) Port Trunking Groups Trunk Group – Up to eight RMAC ports can be selected for each trunk group. 12.3.3.1 TRUNKn– Trunk Group 0~7 CPU Address:h200+n (n = trunk group) Accessed by CPU (R/W) Bit [7:0] Port 7-0 bit map of trunk n. (Default 0) B i t 0 B i t 7 TRUNK0 P o r t 0 P o r t 7 79 Zarlink Semiconductor Inc. ZL50410 12.3.3.2 Data Sheet TRUNKn_HASH10 – Trunk group n hash result 1/0 destination port number CPU Address:h208+4n (n = trunk group) Accessed by CPU (R/W) 12.3.3.3 Bits [3:0] Hash result 0 destination port number (Default 0) Bits [7:4] Hash result 1 destination port number (Default 0) TRUNKn_HASH32 – Trunk group n hash result 3/2 destination port number CPU Address:h209+4n (n = trunk group) Accessed by CPU (R/W) 12.3.3.4 Bits [3:0] Hash result 2 destination port number (Default 0) Bits [7:4] Hash result 3 destination port number (Default 0) TRUNKn_HASH54 – Trunk group n hash result 5/4 destination port number CPU Address:h20A+4n (n = trunk group) Accessed by CPU (R/W) 12.3.3.5 Bits [3:0] Hash result 4 destination port number (Default 0) Bits [7:4] Hash result 5 destination port number (Default 0) TRUNKn_HASH76 – Trunk group n hash result 7/6 destination port number CPU Address:h20B+4n (n = trunk group) Accessed by CPU (R/W) Bits [3:0] Hash result 6 destination port number (Default 0) Bits [7:4] Hash result 7 destination port number (Default 0) 80 Zarlink Semiconductor Inc. ZL50410 12.3.3.6 Data Sheet PVLAN_Pn – Per-Port Private VLAN Edge (Protected Ports) CPU Address:h220+n (n = RMAC port number) Accessed by CPU (R/W) Only applicable if Private VLAN Edge feature is enable (FEN[1]=’1’). NOTE: These registers overlap TRUNK6/7_HASHxy registers, thus, trunk groups 6 and 7 must be disabled (TRUNK6=TRUNK7=0x00) if the PVLAN feature is enabled. Bits [7:0] Port 9,7-0 bit map of protected port n (Default 0x00) Bits [7:0] represent ports 9,7-0, excluding the source port. For example: For port 0, [7:0] represent ports 9,7..1 For port 1, [7:0] represent ports 9,7..2,0 For port 2, [7:0] represent ports 9,7..3,1..0 Multicast Hash Registers Multicast Hash registers are used to distribute multicast traffic. 16 registers are used to form a 8-entry array; each entry has 10 bits, with each bit representing one port. Any port not belonging to a trunk group should be programmed with 1. Ports belonging to the same trunk group should only have a single port set to “1” per entry. The port set to “1” is picked to transmit the multicast frame when the hash value is met. Hash Value =0 HASH0-1 HASH0-0 Hash Value =1 HASH1-1 HASH1-0 Hash Value =2 HASH2-1 HASH2-0 Hash Value =3 HASH3-1 HASH3-0 Hash Value =4 HASH4-1 HASH4-0 Hash Value =5 HASH5-1 HASH5-0 Hash Value =6 HASH6-1 HASH6-0 Hash Value =7 HASH7-1 HASH7-0 P o r t 9 12.3.3.7 P o r t 8 P o r t 7 P o r t 0 MULTICAST_HASHn-0 – Multicast hash result 0~7 mask byte 0 CPU Address:h228+2n (n = hash value) Accessed by CPU (R/W) Bits [7:0]: Port 7-0 bit map for multicast hash. (Default 0xFF) 81 Zarlink Semiconductor Inc. ZL50410 12.3.3.8 Data Sheet MULTICAST_HASHn-1 – Multicast hash result 0~7 mask byte 1 CPU Address:h229+2n (n = hash value) Accessed by CPU (R/W) Bits [1:0]: Port 9-8 bit map for multicast hash. (Default 0x3) Bit [2]: MULTICAST_HASH1-1 Unknown IP Multicast Filter Enable 1: Enable (default) 0: Disable If this feature is enabled, unknown IP multicast packets or unknown multicast packets can be either filtered or sent to the CPU, based on bits [13:12] in the per VLAN Port Association table. This feature is only applicable in tagged-based VLAN mode (PVMODE[0]=’1’). In port-based VLAN mode (PVMODE[0]=’0’), this bit is ignored. MULTICAST_HASH[7:2,0]-1 Reserved (Default 0x1) Bits [5:3]: Reserved (Default 0x7) Bits [7:6]: MULTICAST_HASH0-1 Hash Select. The hash algorithm selected is valid for all trunks 00 - Use Source and Destination MAC Address for hashing 01 - Use Source MAC Address for hashing 10 - Use Destination MAC Address for hashing 11 - Use Source Port Number for hashing (Default) MULTICAST_HASH[7:1]-1 Reserved (Default 0x3) 12.3.4 (Group 3 Address) CPU Port Configuration Group 47 0 MAC5 MAC4 MAC3 MAC2 MAC1 (MC bit) MAC0 MAC5 to MAC0 registers form the CPU MAC address. When a packet with destination MAC address match MAC [5:0], the packet is forwarded to the CPU. The default MAC address is 00-00-00-00-00-00. 12.3.4.1 MAC0 – CPU MAC address byte 0 CPU Address:h300 Accessed by CPU (R/W) Bits [7:0]: Byte 0 (bits [7:0]) of the CPU MAC address (Default 0) 82 Zarlink Semiconductor Inc. ZL50410 12.3.4.2 Data Sheet MAC1 – CPU MAC address byte 1 CPU Address:h301 Accessed by CPU (R/W) Bits [7:0]: 12.3.4.3 Byte 1 (bits [15:8]) of the CPU MAC address (Default 0) MAC2 – CPU MAC address byte 2 CPU Address:h302 Accessed by CPU (R/W) Bits [7:0]: 12.3.4.4 Byte 2 (bits [23:16]) of the CPU MAC address (Default 0) MAC3 – CPU MAC address byte 3 CPU Address:h303 Accessed by CPU (R/W) Bits [7:0]: 12.3.4.5 Byte 3 (bits [31:24]) of the CPU MAC address (Default 0) MAC4 – CPU MAC address byte 4 CPU Address:h304 Accessed by CPU (R/W) Bits [7:0]: 12.3.4.6 Byte 4 (bits [39:32]) of the CPU MAC address (Default 0) MAC5 – CPU MAC address byte 5 CPU Address:h305 Accessed by CPU (R/W) Bits [7:0]: Byte 5 (bits [47:40]) of the CPU MAC address (Default 0) Note: Bits [42:40] are set on a per port basis using MAC01, MAC23, MAC45, MAC67 registers. For port 9, this register is ignored and MAC9 is used for bits [47:40]. 12.3.4.7 INT_MASK0 – Interrupt Mask CPU Address:h306 Accessed by CPU (R/W) The CPU can dynamically mask the interrupt when it is busy and doesn’t want to be interrupted. (Default 0x00) - 1: Mask the interrupt 0: Unmask the interrupt (Enable interrupt) (Default) 83 Zarlink Semiconductor Inc. ZL50410 Data Sheet Bit [0]: CPU frame interrupt. CPU frame buffer has data for CPU to read Bit [1]: Control Command 1 interrupt. Control Command Frame buffer1 has data for CPU to read Bit [2]: Control Command 2 interrupt. Control command Frame buffer2 has data for CPU to read Bits [6:3]: Reserved Bit [7]: Device Timeout Detected interrupt 12.3.4.8 INTP_MASK0 – Interrupt Mask for MAC Port 0,1 CPU Address:h310 Accessed by CPU (R/W) The CPU can dynamically mask the interrupt when it is busy and doesn’t want to be interrupted (Default 0x00) - 1: Mask the interrupt 0: Unmask the interrupt (Default) Bit [0]: Port 0 statistic counter wrap around interrupt mask. An Interrupt is generated when a statistic counter wraps around. Refer to hardware statistic counter for interrupt sources Bit [1]: Port 0 link change mask Bit [2]: Port 0 module detect mask Bit [3]: Reserved Bit [4]: Port 1 statistic counter wrap around interrupt mask. An interrupt is generated when a statistic counter wraps around. Refer to hardware statistic counter for interrupt sources. Bit [5]: Port 1 link change mask Bit [6]: Port 1 module detect mask Bit [7] Reserved 12.3.4.9 INTP_MASKn – Interrupt Mask for MAC Ports 2~9 Registers INTP_MASK1 CPU Address:h311 (Ports 2,3) INTP_MASK2 CPU Address:h312 (Ports 4,5) INTP_MASK3 CPU Address:h313 (Ports 6,7) INTP_MASK4 CPU Address:h314 (Port CPU,GMAC) 12.3.4.10 RQS – Receive Queue Select CPU Address:h323 Accessed by CPU (RW) Select which receive queue is being used by the CPU port. Note: Strict priority applies between different selected queues (UQ3>UQ2>UQ1>UQ0>MQ3>MQ2>MQ1>MQ0). 84 Zarlink Semiconductor Inc. ZL50410 Bit [0]: Data Sheet Select Queue 0 0: Not selected (Default) 1: Selected 12.3.4.11 Bit [1]: Select Queue 1 Bit [2]: Select Queue 2 Bit [3]: Select Queue 3 Bit [4]: Select Multicast Queue 0 Bit [5]: Select Multicast Queue 1 Bit [6]: Select Multicast Queue 2 Bit [7]: Select Multicast Queue 3 RQSS – Receive Queue Status CPU Address:h324 Accessed by CPU (RO) CPU receive queue status Bits [3:0]: Unicast Queue 3 to 0 not empty 0: Empty 1: Not Empty Bits [7:4]: 12.3.4.12 Multicast Queue 3 to 0 not empty MAC01 – Increment MAC port 0,1 address CPU Address:h325 Accessed by CPU (RW) Bits [2:0]: Bits [42:40] of Port 0 CPU MAC address Bit [3]: Reserved Bits [6:4]: Bits [42:40] of Port 1 CPU MAC address Bit [7]: Reserved MAC01, MAC23, MAC45, MAC67, and MAC9 registers are used with the MAC0~5 registers to form the CPU MAC address on a per port basis. 12.3.4.13 MAC23 – Increment MAC port 2,3 address CPU Address:h326 Accessed by CPU (RW) Bits [2:0]: Bits [42:40] of Port 2 CPU MAC address Bit [3]: Reserved 85 Zarlink Semiconductor Inc. ZL50410 Bits [6:4]: Bits [42:40] of Port 3 CPU MAC address Bit [7]: Reserved 12.3.4.14 Data Sheet MAC45 – Increment MAC port 4,5 address CPU Address:h327 Accessed by CPU (RW) Bits [2:0]: Bits [42:40] of Port 4 CPU MAC address Bit [3]: Reserved Bits [6:4]: Bits [42:40] of Port 5 CPU MAC address Bit [7]: Reserved 12.3.4.15 MAC67 – Increment MAC port 6,7 address CPU Address:h328 Accessed by CPU (RW) Bits [2:0]: Bits [42:40] of Port 6 CPU MAC address Bit [3]: Reserved Bits [6:4]: Bits [42:40] of Port 7 CPU MAC address Bit [7]: Reserved 12.3.4.16 MAC9 – Increment MAC port 9 address CPU Address:h329 Accessed by CPU (RW) Bits [7:0]: 12.3.4.17 Bits [47:40] of Port 9 CPU MAC address CPUQINS0 - CPUQINS6 – CPU Queue Insertion Command CPU Address:h330-336 Accessed by CPU, (R/W) 55 CQ6 0 CQ5 CQ4 CQ3 CQ2 86 Zarlink Semiconductor Inc. CQ1 CQ0 ZL50410 Data Sheet CPU Queue insertion command Bits [9:0]: Destination Map (GMAC, CPU, port 7-0). Bits [13:10] Priority Bits [20:14] Number of granules for the frame Bits [35:21] Tail pointer Bits [50:36] Header Pointer Bit [51] Multicast frame (has to be one if more than one destination port) Bits [54:52] Reserved Bit [55] Command valid (will be processed on the rising edge of the signal) 12.3.4.18 CPUQINSRPT – CPU Queue Insertion Report CPU Address:h337 Accessed by CPU, (RO) CPU command queue status Bit [0]: The command is under processing. Bit [1]: Insertion Fail (May be due to queue full, WRED or filtering) 12.3.4.19 CPUGRNHDL0 - CPUGRNHDL1 – CPU Allocated Granule Pointer CPU Address:h338-339 Accessed by CPU, (RO) 15 0 CG1 CG0 CPU Queue insertion command Bits [14:0]: Granule pointer. Bit [15]: Pointer valid 12.3.4.20 CPURLSINFO0 - CPURLSINFO4 – Receive Queue Status CPU Address:h33A-33E Accessed by CPU, (R/W) 0 CR4 CR3 CR2 CR1 87 Zarlink Semiconductor Inc. CR0 ZL50410 Data Sheet CPU Queue insertion command Bits [14:0]: Header pointer Bits [30:15] Tail pointer Bits [38:32] Number of granules for the release 12.3.4.21 CPUGRNCTR – CPU Granule Control CPU Address:h33f Accessed by CPU, (R/W) CPU receive queue status Bit [0]: Allocate granule to the CPU if set to one. Otherwise, do not allocate any resource. Bit [1]: Read allocated granule (at rising edge only) Bit [2]: Release info valid (will be processed at rising edge only) 12.3.5 (Group 4 Address) Search Engine Group 12.3.5.1 AGETIME_LOW – MAC address aging time Low I²C Address h049; CPU Address:h400 Accessed by CPU and I²C (R/W) Used in conjuction with AGETIME_HIGH. The ZL50410 removes the MAC address from the data base and sends a Delete MAC Address Control Command to the CPU. Bits [7:0]: 12.3.5.2 Low byte of the MAC address aging timer (Default 0x5C) AGETIME_HIGH –MAC address aging time High I²C Address h04A; CPU Address h401 Accessed by CPU and I²C (R/W) Bits [7:0]: High byte of the MAC address aging timer (Default 0x00) The default setting of AGETIME_LOW/HIGH provides 300 seconds aging time. Aging time is based on the following equation: {AGETIME_HIGH,AGETIME_LOW} X (# of MAC entries in the memory X 800 µsec). Number of MAC entries = 4 K. 88 Zarlink Semiconductor Inc. ZL50410 12.3.5.3 Data Sheet SE_OPMODE – Search Engine Operation Mode CPU Address:h403 Accessed by CPU (R/W) Note: ECR2[2] enable/disable learning for each port. Bit [0]: Reserved. Must be 0. Bit [1]: Protocol filtering mode 0 – Inclusive (Default) 1 – Exclusive Bit [2]: Delete MAC report control 0 – Report MAC address deletion (MAC address is deleted from MCT after aging time) (Default) 1 – Disable report MAC address deletion Bit [3]: Delete Control 0 – MAC address entry is removed when it is old enough to be aged (Default) 1 – Disable aging logic from removing MAC during aging However, a report is still sent to the CPU in both cases, when bit [2] = 0 12.3.6 12.3.6.1 Bit [4]: Enable RSVP Packet trapping 0 - Disable RSVP Packet trapping. (Default) 1 - Enable RSVP Packet trapping. IP Multicast also needs to be enabled for this function. Bit [5] ARP report control 0 - No ARP packet reporting (Default) 1 - Report ARP packet to CPU Bit [6]: Disable MCT speed-up aging 0 – Enable speed-up aging when MCT resource is low. (Default) 1 – Disable speed-up aging when MCT resource is low. Bit [7]: Slow Learning 0 – Learning is performed independent of search demand (Default) 1 – Enable slow learning. Learning is temporary disabled when search demand is high (Group 5 Address) Buffer Control/QOS Group QOSC – QOS Control I²C Address h04B; CPU Address:h500 Accessed by CPU and I2C (R/W) Bit [0]: Enable TX rate control (on RMAC ports only) 0 – Disable (Default) 1 – Enable 89 Zarlink Semiconductor Inc. ZL50410 12.3.6.2 Bit [1]: Enable RX rate control (on RMAC ports only) 0 – Disable (Default) 1 – Enable Bits [4:2]: Reserved Bit [5]: Select VLAN tag or TOS (IP packets) to be preferentially picked to map transmit priority and drop priority 0 – Select VLAN Tag priority field over TOS (Default) 1 – Select TOS over VLAN tag priority field Bit [6]: Select TOS bits for Priority 0 – Use TOS [4:2] bits to map the transmit priority (Default) 1 – Use TOS [7:5] bits to map the transmit priority Bit [7]: Select TOS bits for Drop priority 0 – Use TOS [4:2] bits to map the drop priority (Default) 1 – Use TOS [7:5] bits to map the drop priority Data Sheet UCC – Unicast Congestion Control I2C Address h068, CPU Address: 510 Accessed by CPU and I2C (R/W) Bits [7:0]: 12.3.6.3 Number of frame count. Used for best effort dropping at B% when destination port’s best effort queue reaches UCC threshold and shared pool is all in use. Granularity is 16 granule (Default 0x6) MCC – Multicast Congestion Control I²C Address h069, CPU Address: 511 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.6.4 In multiples of 16 granules (granularity). Used for triggering MC flow control when destination port’s multicast best effort queue reaches MCC threshold. (Default 0x6) MCCTH – Multicast Threshold Control CPU Address: 512 Accessed by CPU (R/W) Bits [7:0]: Threshold on the multicast granule count. Exceeding the threshold consider as multicast resource low and the new multicast will be dropped at B% or flow control is triggered if enabled. (Default: 0x3) 90 Zarlink Semiconductor Inc. ZL50410 12.3.6.5 Data Sheet RDRC0 – WRED Rate Control 0 I²C Address 090, CPU Address 513 Accessed by CPU and I2C (R/W) Bits [3:0]: Corresponds to the frame drop percentage Y% for WRED. Granularity 6.25%. Bits [7:4]: Corresponds to the frame drop percentage X% for WRED. Granularity 6.25%. See Programming QoS Registers application note, ZLAN-42, for more information 12.3.6.6 RDRC1 – WRED Rate Control 1 I²C Address 091, CPU Address 514 Accessed by CPU and I²C (R/W) Bits [3:0]: Corresponds to the best effort frame drop percentage B%, when shared pool is all in use and destination port best effort queue reaches UCC. Granularity 6.25%. Bits [7:4]: Corresponds to the frame drop percentage Z% for WRED. Granularity 6.25%. See Programming QoS Registers application note, ZLAN-42, for more information 12.3.6.7 RDRC2 – WRED Rate Control 2 CPU Address 515 Accessed by CPU (R/W) 12.3.6.8 Bits [3:0]: Corresponds to the frame drop percentage RB% for ingress rate control. Granularity 6.25%. Bits [7:4]: Corresponds to the frame drop percentage RA% for ingress rate control. Granularity 6.25%. SFCB – Share FCB Size I²C Address h074, CPU Address 518 Accessed by CPU and I²C (R/W) Bits [7:0]: Expressed in multiples of 16 granules. Buffer reservation for shared pool. 91 Zarlink Semiconductor Inc. ZL50410 12.3.6.9 Data Sheet C1RS – Class 1 Reserve Size I²C Address h075, CPU Address 519 Accessed by CPU and I²C (R/W) Bits [7:0]: Class 1 FCB Reservation Buffer reservation for class 1. Granularity 16 granules. (Default 0) 12.3.6.10 C2RS – Class 2 Reserve Size I²C Address h076, CPU Address 51A Accessed by CPU and I²C (R/W) Bits [7:0]: Class 2 FCB Reservation Buffer reservation for class 2. Granularity 16 granules. (Default 0) 12.3.6.11 C3RS – Class 3 Reserve Size I²C Address h077, CPU Address 51B Accessed by CPU and I²C (R/W) Bits [7:0]: Class 3 FCB Reservation Buffer reservation for class 3. Granularity 16 granules. (Default 0) 12.3.6.12 AVPML – VLAN Tag Priority Map I²C Address h056; CPU Address:h530 Accessed by CPU and I²C (R/W) Registers AVPML, AVPMM, and AVPMH allow the eight VLAN Tag priorities to map into eight Internal level transmit priorities. Under the Internal transmit priority, seven is the highest priority where as zero is the lowest. This feature allows the user the flexibility of redefining the VLAN priority field. For example, programming a value of 7 into bit 2:0 of the AVPML register would map packet VLAN priority 0 into Internal transmit priority 7. The new priority is used inside the ZL50410. When the packet goes out it carries the original priority. Bits [2:0]: Priority when the VLAN tag priority field is 0 (Default 0) Bits [5:3]: Priority when the VLAN tag priority field is 1 (Default 0) Bits [7:6]: Priority when the VLAN tag priority field is 2 (Default 0) 92 Zarlink Semiconductor Inc. ZL50410 12.3.6.13 AVPMM – VLAN Priority Map I²C Address h057, CPU Address:h531 Accessed by CPU and I²C (R/W) Map VLAN priority into eight level transmit priorities: 12.3.6.14 Bit [0]: Priority when the VLAN tag priority field is 2 (Default 0) Bits [3:1]: Priority when the VLAN tag priority field is 3 (Default 0) Bits [6:4]: Priority when the VLAN tag priority field is 4 (Default 0) Bit [7]: Priority when the VLAN tag priority field is 5 (Default 0) AVPMH – VLAN Priority Map I²C Address h058, CPU Address:h532 Accessed by CPU and I²C (R/W) Map VLAN priority into eight level transmit priorities: 12.3.6.15 Bits [1:0]: Priority when the VLAN tag priority field is 5 (Default 0) Bits [4:2]: Priority when the VLAN tag priority field is 6 (Default 0) Bits [7:5]: Priority when the VLAN tag priority field is 7 (Default 0) AVDM – VLAN Discard Map I²C Address h05C, CPU Address:h533 Accessed by CPU and I²C (R/W) Map VLAN priority into frame discard when low priority buffer usage is above threshold Bit [0]: Frame drop priority when VLAN Tag priority field is 0 (Default 0) Bit [1]: Frame drop priority when VLAN Tag priority field is 1 (Default 0) Bit [2]: Frame drop priority when VLAN Tag priority field is 2 (Default 0) Bit [3]: Frame drop priority when VLAN Tag priority field is 3 (Default 0) Bit [4]: Frame drop priority when VLAN Tag priority field is 4 (Default 0) Bit [5]: Frame drop priority when VLAN Tag priority field is 5 (Default 0) Bit [6]: Frame drop priority when VLAN Tag priority field is 6 (Default 0) Bit [7]: Frame drop priority when VLAN Tag priority field is 7 (Default 0) 93 Zarlink Semiconductor Inc. Data Sheet ZL50410 12.3.6.16 TOSPML – TOS Priority Map I²C Address h059, CPU Address:h540 Accessed by CPU and I²C (R/W) Map TOS field in IP packet into eight level transmit priorities 12.3.6.17 Bits [2:0]: Priority when the TOS field is 0 (Default 0) Bits [5:3]: Priority when the TOS field is 1 (Default 0) Bits [7:6]: Priority when the TOS field is 2 (Default 0) TOSPMM – TOS Priority Map I²C Address h05A, CPU Address:h541 Accessed by CPU and I²C (R/W) Map TOS field in IP packet into eight level transmit priorities 12.3.6.18 Bit [0]: Priority when the TOS field is 2 (Default 0) Bits [3:1]: Priority when the TOS field is 3 (Default 0) Bits [6:4]: Priority when the TOS field is 4 (Default 0) Bit [7]: Priority when the TOS field is 5 (Default 0) TOSPMH – TOS Priority Map I²C Address h05B, CPU Address:h542 Accessed by CPU and I²C (R/W) Map TOS field in IP packet into eight level transmit priorities: 12.3.6.19 Bits [1:0]: Priority when the TOS field is 5 (Default 0) Bits [4:2]: Priority when the TOS field is 6 (Default 0) Bits [7:5]: Priority when the TOS field is 7 (Default 0) TOSDML – TOS Discard Map I²C Address h05D, CPU Address:h543 Accessed by CPU and I²C (R/W) Map TOS into frame discard when low priority buffer usage is above threshold Bit [0]: Frame drop priority when TOS field is 0 (Default 0) Bit [1]: Frame drop priority when TOS field is 1 (Default 0) Bit [2]: Frame drop priority when TOS field is 2 (Default 0) 94 Zarlink Semiconductor Inc. Data Sheet ZL50410 12.3.6.20 Bit [3]: Frame drop priority when TOS field is 3 (Default 0) Bit [4]: Frame drop priority when TOS field is 4 (Default 0) Bit [5]: Frame drop priority when TOS field is 5 (Default 0) Bit [6]: Frame drop priority when TOS field is 6 (Default 0) Bit [7]: Frame drop priority when TOS field is 7 (Default 0) Data Sheet USER_PROTOCOL_n – User Define Protocol 0~7 I²C Address h0B3+n, CPU Address:h550+n Accessed by CPU and I²C (R/W) (Default 00) This register is duplicated eight times from PROTOCOL 0~7 and allows the CPU to define eight separate protocols. Bits [7:0]: 12.3.6.21 User Define Protocol USER_PROTOCOL_FORCE_DISCARD – User Define Protocol 0~7 Force Discard I²C Address h0BB, CPU Address 558 Accessed by CPU and I²C (R/W) Bit [0]: Enable Protocol 0 Force Discard 1 – Enable 0 – Disable Bit [1]: Enable Protocol 1 Force Discard Bit [2]: Enable Protocol 2 Force Discard Bit [3]: Enable Protocol 3 Force Discard Bit [4]: Enable Protocol 4 Force Discard Bit [5]: Enable Protocol 5 Force Discard Bit [6]: Enable Protocol 6 Force Discard Bit [7]: Enable Protocol 7 Force Discard User Defined Logical Ports and Well Known Ports The ZL50410 supports classifying packet priority through layer 4 logical port information. It can be setup by 8 Well Known Ports, 8 User Defined Logical Ports, and 1 User Defined Range. The 8 Well Known Ports supported are: • • • • • 23 512 6000 443 111 95 Zarlink Semiconductor Inc. ZL50410 • • • Data Sheet 22555 22 554 Their respective priority can be programmed via WELL_KNOWN_PORT[7:0]_PRIORITY WELL_KNOWN_PORT[_ENABLE can individually turn on/off each Well Known Port if desired. register. Similarly, the User Defined Logical Port provides the user programmability to the priority, plus the flexibility to select specific logical ports to fit the applications. The 8 User Logical Ports can be programmed via User_Port 0-7 registers. Two registers are required to be programmed for the logical port number. The respective priority can be programmed to the User_Port [7:0] priority register. The port priority can be individually enabled/disabled via User_Port_Enable register. The User Defined Range provides a range of logical port numbers with the same priority level. Programming is similar to the User Defined Logical Port. Instead of programming a fixed port number, an upper and lower limit need to be programmed, they are: {RHIGHH, RHIGHL} and {RLOWH, RLOWL} respectively. If the value in the upper limit is smaller or equal to the lower limit, the function is disabled. Any IP packet with a logical port that is less than the upper limit and more than the lower limit will use the priority specified in RPRIORITY. 12.3.6.22 WELL_KNOWN_PORT[1:0]_PRIORITY- Well Known Logic Port 1 and 0 Priority I²C Address h0A8, CPU Address 560 Accessed by CPU and I²C (R/W) 12.3.6.23 Bits [3:0]: Priority setting, transmission + dropping, for Well known port 0 (23 for telnet) Bits [7:4]: Priority setting, transmission + dropping, for Well known port 1 (512 for TCP/UDP) WELL_KNOWN_PORT[3:2]_PRIORITY- Well Known Logic Port 3 and 2 Priority I²C Address h0A9, CPU Address 561 Accessed by CPU and I²C (R/W) 12.3.6.24 Bits [3:0]: Priority setting, transmission + dropping, for Well known port 2 (6000 for XWIN) Bits [7:4]: Priority setting, transmission + dropping, for Well known port 3 (443 for HTTP sec) WELL_KNOWN_PORT[5:4]_PRIORITY- Well Known Logic Port 5 and 4 Priority I²C Address h0AA, CPU Address 562 Accessed by CPU and I²C (R/W) Bits [3:0]: Priority setting, transmission + dropping, for Well known port 4 (111 for sun remote procedure call) Bits [7:4]: Priority setting, transmission + dropping, for Well known port 5 (22555 for IP Phone call setup) 96 Zarlink Semiconductor Inc. ZL50410 12.3.6.25 Data Sheet WELL_KNOWN_PORT[7:6]_PRIORITY- Well Known Logic Port 7 and 6 Priority I²C Address h0AB, CPU Address 563 Accessed by CPU and I²C (R/W) 12.3.6.26 Bits [3:0]: Priority setting, transmission + dropping, for Well known port 6 (22 for ssh) Bits [7:4]: Priority setting, transmission + dropping, for Well known port 7 (554 for rtsp) WELL_KNOWN_PORT_ENABLE – Well Known Logic Port 0 to 7 Enables I²C Address h0AC, CPU Address 564 Accessed by CPU and I²C (R/W) 12.3.6.27 Discard Bit [0]: Enable Well Known Port 0 Priority 1 – Enable 0 – Disable Bit [1]: Enable Well Known Port 1 Priority Bit [2]: Enable Well Known Port 2 Priority Bit [3]: Enable Well Known Port 3 Priority Bit [4]: Enable Well Known Port 4 Priority Bit [5]: Enable Well Known Port 5 Priority Bit [6]: Enable Well Known Port 6 Priority Bit [7]: Enable Well Known Port 7 Priority WELL_KNOWN_PORT_FORCE_DISCARD – Well Known Logic Port 0~7 Force I²C Address h0AD, CPU Address 565 Accessed by CPU and I²C (R/W) Bit [0]: Enable Well Known Port 0 Force Discard 1 – Enable 0 – Disable Bit [1]: Enable Well Known Port 1 Force Discard Bit [2]: Enable Well Known Port 2 Force Discard Bit [3]: Enable Well Known Port 3 Force Discard Bit [4]: Enable Well Known Port 4 Force Discard Bit [5]: Enable Well Known Port 5 Force Discard Bit [6]: Enable Well Known Port 6 Force Discard Bit [7]: Enable Well Known Port 7 Force Discard 97 Zarlink Semiconductor Inc. ZL50410 12.3.6.28 Data Sheet USER_PORT[7:0]_[LOwithHIGH] – User Define Logical Port 0~7 I²C Address h092+n(Low); CPU Address 570+2n(Low) (n = logical port number) I²C Address h09A+n(High); CPU Address 571+2n(High) Accessed by CPU and I²C (R/W) (Default 00) This register is duplicated eight times from PORT 0 through PORT 7 and allows the CPU to define eight separate ports. 7 0 TCP/UDP Logic Port Low 7 0 TCP/UDP Logic Port High 12.3.6.29 USER_PORT_[1:0]_PRIORITY - User Define Logic Port 1 and 0 Priority I²C Address h0A2, CPU Address 590 Accessed by CPU and I²C (R/W) The chip allows the CPU to define the priority 12.3.6.30 Bits [3:0]: Priority setting, transmission + dropping, for logic port 0 Bits [7:4]: Priority setting, transmission + dropping, for logic port 1 (Default 00) USER_PORT_[3:2]_PRIORITY - User Define Logic Port 3 and 2 Priority I²C Address h0A3, CPU Address 591 Accessed by CPU and I²C (R/W) 12.3.6.31 Bits [3:0]: Priority setting, transmission + dropping, for logic port 2 Bits [7:4]: Priority setting, transmission + dropping, for logic port 3 (Default 00) USER_PORT_[5:4]_PRIORITY - User Define Logic Port 5 and 4 Priority I²C Address h0A4, CPU Address 592 Accessed by CPU and I²C (R/W) Bits [3:0]: Priority setting, transmission + dropping, for logic port 4 Bits [7:4]: Priority setting, transmission + dropping, for logic port 5 (Default 00) 98 Zarlink Semiconductor Inc. ZL50410 12.3.6.32 Data Sheet USER_PORT_[7:6]_PRIORITY - User Define Logic Port 7 and 6 Priority I²C Address h0A5, CPU Address 593 Accessed by CPU and I²C (R/W) 12.3.6.33 Bits [3:0]: Priority setting, transmission + dropping, for logic port 6 Bits [7:4]: Priority setting, transmission + dropping, for logic port 7 (Default 00) USER_PORT_ENABLE[7:0] – User Define Logic Port 0 to 7 Enables I²C Address h0A6, CPU Address 594 Accessed by CPU and I²C (R/W) Bit [0]: Enable User Port 0 Priority 1 – Enable 0 – Disable 12.3.6.34 Bit [1]: Enable User Port 1 Priority Bit [2]: Enable User Port 2 Priority Bit [3]: Enable User Port 3 Priority Bit [4]: Enable User Port 4 Priority Bit [5]: Enable User Port 5 Priority Bit [6]: Enable User Port 6 Priority Bit [7]: Enable User Port 7 Priority USER_PORT_FORCE_DISCARD[7:0] – User Define Logic Port 0~7 Force Discard I²C Address h0A7, CPU Address 595 Accessed by CPU and I²C (R/W) Bit [0]: Enable User Port 0 Force Discard 1 – Enable 0 – Disable Bit [1]: Enable User Port 1 Force Discard Bit [2]: Enable User Port 2 Force Discard Bit [3]: Enable User Port 3 Force Discard Bit [4]: Enable User Port 4 Force Discard Bit [5]: Enable User Port 5 Force Discard Bit [6]: Enable User Port 6 Force Discard Bit [7]: Enable User Port 7 Force Discard 99 Zarlink Semiconductor Inc. ZL50410 12.3.6.35 Data Sheet RLOWL – User Define Range Low Bit 7:0 I²C Address h0AE, CPU Address: 5A0 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.6.36 Lower 8 bit of the User Define Logical Port Low Range RLOWH – User Define Range Low Bit 15:8 I²C Address h0AF, CPU Address: 5A1 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.6.37 Upper 8 bit of the User Define Logical Port Low Range RHIGHL – User Define Range High Bit 7:0 I²C Address h0B0, CPU Address: 5A2 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.6.38 Lower 8 bit of the User Define Logical Port High Range RHIGHH – User Define Range High Bit 15:8 I²C Address h0B1, CPU Address: 5A3 Accessed by CPU and I²C (R/W) Bits [7:0]: 12.3.6.39 Upper 8 bit of the User Define Logical Port High Range RPRIORITY – User Define Range Priority I²C Address h0B2, CPU Address: 5A4 Accessed by CPU and I²C (R/W) RLOW and RHIGH form a range for logical ports to be classified with priority specified in RPRIORITY. Bit [0]: Drop Priority (inclusive only) Bits [3:1] Transmit Priority (inclusive only) Bits [5:4] Reserved Bits [7:6] 00 - No Filtering 01 - Exclusive Filtering (x<=RLOW or x>=RHIGH) 10 - Inclusive Filtering (RLOW<x<RHIGH) 11 - Invalid 100 Zarlink Semiconductor Inc. ZL50410 12.3.7 12.3.7.1 Data Sheet (Group 6 Address) MISC Group MII_OP0 – MII Register Option 0 I²C Address 0BC, CPU Address:h600 Accessed by CPU and I²C (R/W) Bits [4:0]: Vendor specified link status register address (null value means don’t use it) (Default 00). This is used if the Linkup bit position in the PHY is non-standard Bits [5] Disable jabber detection. This is for HomePNA applications or any serial operation slower than 10 Mbps. 0 = Enable 1 = Disable Bits [6] Reserved Bit [7]: Half duplex flow control feature 0 = Half duplex flow control always enable 1 = Half duplex flow control by negotiation 12.3.7.2 MII_OP1 – MII Register Option 1 I²C Address 0BD, CPU Address:h601 Accessed by CPU and I²C (R/W) Bits [3:0]: Duplex bit location in vendor specified register Bits [7:4]: Speed bit location in vendor specified register (Default 00) 12.3.7.3 FEN – Feature Register I²C Address 0BE, CPU Address:h602) Accessed by CPU and I²C (R/W) Bit [0]: Statistic Counter 0 – Disable (Default) 1 – Enable (all ports) When statistic counter is enable, an interrupt control frame is generated to the CPU, every time a counter wraps around. This feature requires an external CPU. 101 Zarlink Semiconductor Inc. ZL50410 Bit [1]: Data Sheet Private VLAN Edge Support 0: Disable (default) 1: Enable If this feature is enabled, use registers PVLAN_Pn to set up the egress protected port map. This feature is only applicable in tagged-based VLAN mode (PVMODE[0]=’1’). In port-based VLAN mode (PVMODE[0]=’0’), this bit must be 0. See Private VLAN Edge application note, ZLAN-130, for more information. Bit [2]: Support DS EF Code. 0 – Disable (Default) 1 – Enable (all ports) When 101110 is detected in DS field (TOS[7:2]), the frame priority is set for 110 and drop is set for 0. Bit [3]: Enable VLAN ID hashing 0 – Disable (Default) 1 – Enable Bit [4]: Disable IP Multicast Support 0 – Enable IP Multicast Support (Must also set PVMODE[6]=1) 1 – Disable IP Multicast Support (Default) When enable, IGMP packets are identified by search engine and are passed to the CPU for processing. IP multicast packets are forwarded to the IP multicast group members according to the VLAN port mapping table. Bit [5]: Report to CPU 0 – Disable (Default) 1 – Enable When disable new VLAN port association report, new MAC address report or aging reports are disable for all ports. When enable, register SE_OPMODE is used to enable/disable selectively each function. 12.3.7.4 Bit [6]: MII Management State Machine 0: Enable (Default) 1: Disable This bit must be set so that there is no contention on the MDIO bus between MII Management state machine and MIIC & MIID PHY register accesses. Bit [7]: MCT Link List structure 0 – Enable (Default) 1 – Disable MIIC0 – MII Command Register 0 CPU Address:h603 Accessed by CPU (R/W) Bits [7:0]: MII Command Data [7:0] 102 Zarlink Semiconductor Inc. ZL50410 Data Sheet Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY, and no VALID; then program MII command. 12.3.7.5 MIIC1 – MII Command Register 1 CPU Address:h604 Accessed by CPU (R/W) Bits [7:0]: MII Command Data [15:8] Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY and no VALID; then program MII command. 12.3.7.6 MIIC2 – MII Command Register 2 CPU Address:h605 Accessed by CPU (R/W) Bits [4:0] REG_AD – Register PHY Address Bits [6:5] OP – Operation code “10” for read command and “01” for write command Bits [7] Reserved Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY and no VALID; then program MII command. 12.3.7.7 MIIC3 – MII Command Register 3 CPU Address:h606 Accessed by CPU (R/W) Bits [4:0] PHY_AD – 5 Bit PHY Address Bit [5] Reserved Bit [6] VALID – Data Valid from PHY (Read Only) Bit [7] RDY – Data is returned from PHY (Read Only) Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY and no VALID; then program MII command. Writing this register will initiate a serial management cycle to the MII management interface. 12.3.7.8 MIID0 – MII Data Register 0 CPU Address:h607 Accessed by CPU (RO) Bits [7:0]: MII Data [7:0] 103 Zarlink Semiconductor Inc. ZL50410 12.3.7.9 Data Sheet MIID1 – MII Data Register 1 CPU Address:h608 Accessed by CPU (RO) Bits [7:0]: 12.3.7.10 MII Data [15:8] USD – One Micro Second Divider CPU Address:h609 Accessed by CPU (R/W) Bits [5:0]: Divider to get one micro second from M_CLK (only used when not in standard RMII mode) In a MII or GPSI system, a 50MHz M_CLK may not be available. The system designer can decide to use another frequency on the M_CLK signal. To compensate for this, this register is required to be programmed. For example. If 20MHz is used on M_CLK, to compensate for the difference, this register is programmed with 20 to provide 1usec for internal reference. Bits [7:6]: 12.3.7.11 Reserved DEVICE Mode CPU Address:h60A Accessed by CPU (R/W) 12.3.7.12 Bit [0]: Reserved Bit [1]: CPU Interrupt Polarity 0: Negative Polarity 1: Positive Polarity (Default) Bits [4:2]: Reserved Bits [7:5]: DEVICE ID (Default 0). This is for stacking operation. This is the stack ID for loop topology. CHECKSUM - EEPROM Checksum I²C Address 0FF, CPU Address:h60B Accessed by CPU and I²C (R/W) Bits [7:0]: Checksum content (Default 0) This register is used in unmanaged mode only. Before requesting that the ZL50410 updates the EEPROM device, the correct checksum needs to be calculated and written into this checksum register. 104 Zarlink Semiconductor Inc. ZL50410 Data Sheet The checksum formula is: FF Σ I²C register = 0 i=0 When the ZL50410 boots from the EEPROM the checksum is calculated and the value must be zero. If the checksum is not zeroed the ZL50410 does not start and pin CHECKSUM_OK is set to zero. 12.3.7.13 LHBTimer – Link Heart Beat Timeout Timer CPU Address:h610 Accessed by CPU (R/W) In slot time (512 bit time). LHB packet will be sent out to the remote device if no other packet is transmitted in half this period. The receiver will trigger LHB timeout interrupt if not receiving any good packet in this period. 12.3.7.14 LHBReg0, LHBReg1 - Link Heart Beat OpCode CPU Address:h611, h612 Accessed by CPU (R/W) The LHB frame uses MAC control frame format (same as flow control frame.) The register here defines the operation code (we recommend h00-12). 12.3.7.15 fMACCReg0, fMACCReg1 - MAC Control Frame OpCode CPU Address:h613, h614 Accessed by CPU (R/W) The registers define the operation code if MAC control frame is forced out by processor. 12.3.7.16 FCB Base Address Register 0 I²C Address 0BF, CPU Address:h620 Accessed by CPU and I²C (R/W) Bits [7:0] 12.3.7.17 FCB Base address bit 7:0 (Default 0) FCB Base Address Register 1 I²C Address 0C0, CPU Address:h621 Accessed by CPU and I²C (R/W) Bits [7:0] FCB Base address bit 15:8 (Default 0x60) 105 Zarlink Semiconductor Inc. ZL50410 12.3.7.18 Data Sheet FCB Base Address Register 2 I²C Address 0C1, CPU Address:h622 Accessed by CPU and I²C (R/W) Bits [7:0] 12.3.8 12.3.8.1 FCB Base address bit 23:16 (Default 0) (Group 7 Address) Port Mirroring Group MIRROR CONTROL – Port Mirror Control Register CPU Address 70C Accessed by CPU (R/W) (Default 00) 12.3.8.2 Bits [3:0]: Destination port to be mirrored to. Bit [4] Mirror Flow from MIRROR_SRC_MAC[5:0] to MIRROR_DEST_MAC[5:0] Bit [5] Mirror Flow from MIRROR_DEST_MAC[5:0] to MIRROR_SRC_MAC[5:0] Bit [6]: Mirror when address is destination Bit [7]: Mirror when address is source MIRROR_DEST_MAC[5:0] – Mirror Destination MAC Address 0~5 CPU Address 700-705 Accessed by CPU (R/W) 12.3.8.3 DEST_MAC5 DEST_MAC4 DEST_MAC3 DEST_MAC2 DEST_MAC1 DEST_MAC0 [47:40] (Default 00) [39:32] (Default 00) [31:24] (Default 00) [23:16] (Default 00) [15:8] (Default 00) [7:0] (Default 00) MIRROR_SRC _MAC[5:0] – Mirror Source MAC Address 0~5 CPU Address 706-70B Accessed by CPU (R/W) SRC_MAC5 SRC_MAC4 SRC_MAC3 SRC_MAC2 SRC_MAC1 SRC_MAC0 [47:40] (Default 00) [39:32] (Default 00) [31:24] (Default 00) [23:16] (Default 00) [15:8] (Default 00) [7:0] (Default 00) 106 Zarlink Semiconductor Inc. ZL50410 12.3.8.4 Data Sheet RMAC_MIRROR0 – RMAC Mirror 0 CPU Address 710 Accessed by CPU (R/W) 12.3.8.5 Bits [2:0]: Source port to be mirrored Bit [3]: Mirror path 0: Receive 1: Transmit Bits [6:4]: Destination port for mirrored traffic Bit [7]: Mirror enable RMAC_MIRROR1 – RMAC Mirror 1 CPU Address 711 Accessed by CPU (R/W) 12.3.9 12.3.9.1 Bits [2:0]: Source port to be mirrored Bit [3]: Mirror path 0: Receive 1: Transmit Bits [6:4]: Destination port for mirrored traffic Bit [7]: Mirror enable (Group 8 Address) Per Port QOS Control FCRn – Port 0~9 Flooding Control Register I²C Address h04C+n; CPU Address:h800+n (n = port number) Accessed by CPU and I²C (R/W) Bits [3:0]: U2MR: Unicast to Multicast Rate. Units in terms of time base defined in bits [6:4]. This is used to limit the amount of flooding traffic from Port n. The value in U2MR specifies how many packets are allowed to flood within the time specified by bit [6:4]. To disable this function, program U2MR to 0. (Default = 0) Bits [6:4]: Time Base for Unicast to Multicast, Multicast and Broadcast rate control of Port n: (Default = 000) 000 = 100 us 001 = 200 us 010 = 400 us 011 = 800 us 100 = 1.6 ms 101 = 3.2 ms 110 = 6.4 ms 111 = 12.8 ms Bit [7]: Reserved 107 Zarlink Semiconductor Inc. ZL50410 12.3.9.2 Data Sheet BMRCn - Port 0~9 Broadcast/Multicast Rate Control I²C Address h05E+n, CPU Address:h820+n (n = port number) Accessed by CPU and I²C (R/W) This broadcast and multicast rate defines for Port n, the number of packets allowed to be forwarded within a specified time. Once the packet rate is reached, packets will be dropped. To turn off the rate limit, program the field to 0. Time base is based on register FCR0 [6:4] Bits [3:0]: Multicast Rate Control. Number of multicast packets allowed within the time defined in bits 6 to 4 of the Flooding Control Register (FCRn). (Default 0). Bits [7:4]: Broadcast Rate Control. Number of broadcast packets allowed within the time defined in bits 6 to 4 of the Flooding Control Register (FCRn). (Default 0) 12.3.9.3 PR100_n – Port 0~7 Reservation I²C Address h06A+n, CPU Address 840+n (n = port number) Accessed by CPU and I²C (R/W) Expressed in multiples of 16 granules. (Default 0x6) 12.3.9.4 PR100_CPU – Port CPU Reservation I²C Address h073, CPU Address 848 Accessed by CPU and I²C (R/W) Expressed in multiples of 16 granules. (Default 0x6) 12.3.9.5 PRG – Port GMAC Reservation I²C Address h072, CPU Address 849 Accessed by CPU and I²C (R/W) Expressed in multiples of 16 granules. (Default 0x24) 12.3.9.6 PTH100_n – Port 0~7 Threshold I²C Address h0C2+n, CPU Address 860+n (n = port number) Accessed by CPU and I²C (R/W) Expressed in multiples of 16 granules. More than this number used on a source port will trigger either random drop or flow control (Default 0x3) 12.3.9.7 PTH100_CPU – Port CPU Threshold I²C Address h0CB, CPU Address 868 Accessed by CPU and I²C (R/W) Expressed in multiples of 16 granules. More than this number used on a source port will trigger either random drop or flow control (Default 0x3) 108 Zarlink Semiconductor Inc. ZL50410 12.3.9.8 Data Sheet PTHG – Port GMAC Threshold I²C Address h0CA, CPU Address 869 Accessed by CPU and I²C (R/W) Expressed in multiples of 16 granules. More than this number used on a source port will trigger either random drop or flow control (Default 0x12) 12.3.9.9 QOSC00, QOSC01 - Classes Byte Limit port 0 Accessed by CPU and I²C (R/W) • • QOSC00 – BYTE_L1 (I²C Address h078, CPU Address 880) QOSC01 – BYTE_L2 (I²C Address h079, CPU Address 881) Multiple of 16 granules. The two numbers set the two level for WRED on the high priority queue. When the queue size exceeds the L1 threshold, received frame will subject to X% (high drop) or Y% (low drop) WRED. When the queue size exceeds L2 threshold, received frame will either be filtered (high drop) or subject to Z% WRED. 12.3.9.10 QOSC02, QOSC15 - Classes Byte Limit port 1-7 I²C Address 07A-087, CPU Address:h882-88F Accessed by CPU and I²C (R/W) Same as QOSC00, QOSC01 12.3.9.11 QOSC16 - QOSC21 - Classes Byte Limit CPU port Accessed by CPU and I2C (R/W): • • • • • • QOSC16 QOSC17 QOSC18 QOSC19 QOSC20 QOSC21 – – – – – – BYTE_L11 Level 1 for queue 1 (I2C Address h088, CPU Address 890) BYTE_L21 Level 2 for queue 1 (I2C Address h089, CPU Address 891) BYTE_L12 Level 1 for queue 2 (I2C Address h08A, CPU Address 892) BYTE_L22 Level 2 for queue 2 (I2C Address h08B, CPU Address 893) BYTE_L13 Level 1 for queue 3 (I2C Address h08C, CPU Address 894) BYTE_L23 Level 2 for queue 3 (I2C Address h08D, CPU Address 895) Multiple of 16 granules. The two numbers set the two level for WRED on the high priority queue. When the queue size exceeds the L1 threshold, received frame will subject to X% (high drop) or Y% (low drop) WRED. When the queue size exceeds L2 threshold, received frame will either be filtered (high drop) or subject to Z% WRED. 12.3.9.12 QOSC22 - QOSC27 - Classes Byte Limit GMAC port Accessed by CPU and I²C (R/W) • • • • • • QOSC22 QOSC23 QOSC24 QOSC25 QOSC26 QOSC27 – – – – – – BYTE_L11 Level 1 for queue 1 (I²C Address h08E, CPU Address 896) BYTE_L21 Level 2 for queue 1 (I²C Address h08F, CPU Address 897) BYTE_L12 Level 1 for queue 2 (CPU Address 898) BYTE_L22 Level 2 for queue 2 (CPU Address 899) BYTE_L13 Level 1 for queue 3 (CPU Address 89A) BYTE_L23 Level 2 for queue 3 (CPU Address 89B) Multiple of 16 granules. The two numbers set the two level for WRED on the high priority queue. When the queue size exceeds the L1 threshold, received frame will subject to X% (high drop) or Y% (low drop) WRED. When the queue size exceeds L2 threshold, received frame will either be filtered (high drop) or subject to Z% WRED. 109 Zarlink Semiconductor Inc. ZL50410 12.3.9.13 Data Sheet QOSC28 - QOSC31 - Classes WFQ Credit For GMAC Accessed by CPU (R/W) W0 – QOSC28[5:0] – CREDIT_C00 (CPU Address 89C) W1 – QOSC29[5:0] – CREDIT_C01 (CPU Address 89D) W2 – QOSC30[5:0] – CREDIT_C02 (CPU Address 89E) W3 – QOSC31[5:0] – CREDIT_C03 (CPU Address 89F) QOSC28 through QOSC31 represents one set of WFQ parameters for GMAC port. The granularity of the numbers is 1, and their sum must be 64. QOSC31 corresponds to W3 that is the highest priority, and QOSC27 corresponds to W0. Default scheduling method will be strict priority across all queues. Only when the bit 7 in the class is set, the queue will be scheduled as WFQ. The credit number also works as shaper credit if bit 6 is set. The queue with shaper enabled will be scheduled by strict priority when the token is available. The shaper setting override the NS setting. Bits [5:0]: Class scheduling credit Bit [6]: Shaper enable Bit [7]: Not strict priority apply 12.3.9.14 QOSC36 - QOSC39 - Shaper Control Port GMAC Accessed by CPU (R/W) W0 – QOSC36[7:0] – TOKEN_LIMIT_C00 (CPU Address 8A4) W1 – QOSC37[7:0] – TOKEN_LIMIT_C01 (CPU Address 8A5) W2 – QOSC38[7:0] – TOKEN_LIMIT_C02 (CPU Address 8A6) W3 – QOSC39[7:0] – TOKEN_LIMIT_C03 (CPU Address 8A7) QOSC36 through QOSC39 represents one set of token limit on the shaper of GMAC port. The granularity of the numbers is 64 bytes. The shaper is implemented as leaky bucket and the limit here works as bucket size. Since the hardware implementation can keep negative number, the limit can be as small as one and still can transmit oversized frame, as long as one byte token is available. 12.3.10 (Group E Address) System Diagnostic NOTE: Device Manufacturing test registers. 12.3.10.1 DTSRL – Test Output Selection CPU Address E00 Accessed by CPU (R/W) Test group selection for testout[7:0]. 12.3.10.2 DTSRM – Test Output Selection CPU Address E01 Accessed by CPU (R/W) Test group selection for testout[15:8]. 110 Zarlink Semiconductor Inc. ZL50410 12.3.10.3 Data Sheet TESTOUT0, TESTOUT1 – Testmux Output [7:0], [15:8] CPU Address E02, E03 Accessed by CPU (RO) 12.3.10.4 MASK0-MASK4 – Timeout Reset Mask CPU Address E10-E14 Accessed by CPU (R/W) Disable timeout reset on selected state machine status. See Programming Timeout Reset application note, ZLAN-41, for more information. 12.3.10.5 BOOTSTRAP0 – BOOTSTRAP3 CPU Address E80-E83 Accessed by CPU (RO) 31 23 BT3 15 BT2 0 BT1 Bits [15:0]: Bootstrap value from TSTOUT[15:0]: Bit [6:0]: TSTOUT[6:0] Bit [8:7]: Invert of TSTOUT[8:7] Bit [9]: TSTOUT[11] Bit [10]: TSTOUT[9] Bit [11]: TSTOUT[10] Bit [14:12]: TSTOUT[14:12] Bit [15]: Always 0 Bits [23:16]: Bootstrap value from M[7:0]_TXEN Bit [16]: M0_TXEN Bit [17]: M1_TXEN ... Bit [23]: M7_TXEN Bits [25:24]: Bootstrap value from M9_TXEN, M9_TXER Bits [31:26]: Reserved 12.3.10.6 PRTFSMST0~9 CPU Address E90+n Accessed by CPU (RO) Bit [0]: TX FSM NOT idle for 5 sec Bit [1]: TX FIFO control NOT idle for 5 sec Bit [2]: RX SFD detection NOT idle for 5 sec Bit [3]: RXINF NOT idle for 5 sec 111 Zarlink Semiconductor Inc. BT0 ZL50410 12.3.10.7 Bit [4]: PTCTL NOT idle for 5 sec Bit [5]: Reserved Bit [6] LHB frame detected Bit [7]: LHB receiving timeout Data Sheet PRTQOSST0-PRTQOSST7 CPU Address EA0+n Accessed by CPU (RO) 12.3.10.8 Bit [0]: Source port reservation low Bit [1]: No source port buffer left Bit [2]: Unicast congestion detected on best effort queue Bit [3]: Reserved Bit [4]: High priority queue reach L1 WRED level Bit [5]: High priority queue reach L2 WRED level Bit [6]: Low priority MC queue full Bit [7]: High priority MC queue full PRTQOSST8A, PRTQOSST8B (CPU port) CPU Address EA8 – EA9 Accessed by CPU (RO) 0 15 PQSTB PQSTA Bit [0]: Source port reservation low Bit [1]: No source port buffer left Bit [2]: Unicast congestion detected on best effort queue Bit [3]: Reserved Bit [4]: priority queue 1 reach L1 WRED level Bit [5]: priority queue 1 reach L2 WRED level Bit [6]: priority queue 2 reach L1 WRED level Bit [7]: priority queue 2 reach L2 WRED level Bit [8]: priority queue 3 reach L1 WRED level 112 Zarlink Semiconductor Inc. ZL50410 Bit [9]: priority queue 3 reach L2 WRED level Bit [10]: priority 0 MC queue full Bit [11]: priority 1 MC queue full Bit [12]: priority 2 MC queue full Bit [13]: Priority 3 MC queue full Bits [15:14]: Reserved 12.3.10.9 Data Sheet PRTQOSST9A, PRTQOSST9B (GMAC port) CPU Address EAA – EAB Accessed by CPU (RO) 0 15 PQSTB PQSTA Bit [0]: Source port reservation low Bit [1]: No source port buffer left Bit [2]: Unicast congestion detected on best effort queue Bit [3]: Reserved Bit [4]: Priority queue 1 reach L1 WRED level Bit [5]: Priority queue 1 reach L2 WRED level Bit [6]: Priority queue 2 reach L1 WRED level Bit [7]: Priority queue 2 reach L2 WRED level Bit [8]: Priority queue 3 reach L1 WRED level Bit [9]: Priority queue 3 reach L2 WRED level Bit [10]: Priority 0 MC queue full Bit [11]: Priority 1 MC queue full Bit [12]: Priority 2 MC queue full Bit [13]: Priority 3 MC queue full Bits [15:14]: Reserved 113 Zarlink Semiconductor Inc. ZL50410 12.3.10.10 CLASSQOSST CPU Address EAC Accessed by CPU (RO) Bit [0]: No share buffer Bit [1]: No class 1 buffer Bit [2]: No class 2 buffer Bit [3]: No class 3 buffer Bits [7:4]: Reserved 12.3.10.11 PRTINTCTR CPU Address EAD Accessed by CPU (R/W) Bit [0]: Interrupt when source buffer low Bit [1]: Interrupt when no source buffer Bit [2]: Interrupt when UC congest Bit [3]: Interrupt when L1 WRED level Bit [4]: Interrupt when L2 WRED level Bit [5]: Interrupt when MC queue full Bit [6]: Interrupt when LHB timeout Bit [7]: Interrupt when no class buffer 12.3.10.12 QMCTRL0~9 CPU Address EB0+n Accessed by CPU (R/W) Bit [0]: Suspend port scheduling (no departure) Bit [1]: Reset queue Bits [4:2]: Reserved Bit [5]: Force out MAC control frame Bit [6]: Force out XOFF flow control frame Bit [7]: Force out XON flow control frame 114 Zarlink Semiconductor Inc. Data Sheet ZL50410 12.3.10.13 QCTRL CPU Address EBA Accessed by CPU (R/W) Bit [0]: Stop QM FSM at idle Bit [1]: Stop MCQ FSM at idle Bit [2]: Stop new granule grant to any source Bit [3]: Stop release granule from any source Bits [7:4]: Reserved 12.3.10.14 BMBISTR0, BMBISTR1 CPU Address EBB, EBC Accessed by CPU (RO) 12.3.10.15 BMControl CPU Address EBD Accessed by CPU (R/W) Bits [3:0]: Block Memory redundancy control 0: Use hardware detected value All others: Overwrite the hardware detected memory swap map Bits [7:4]: Reserved 115 Zarlink Semiconductor Inc. Data Sheet ZL50410 12.3.10.16 Data Sheet BUFF_RST CPU Address EC0 Accessed by CPU (R/W) Bits [3:0] Assign a value that the pool to be reset 0: port 0 pool 1: port 1 pool 2: port 2 pool 3: port 3 pool 4: port 4 pool 5: port 5 pool 6: port 6 pool 7: port 7 pool 8: port GMAC pool 9: shared pool 10: class 1 pool 11: class 2 pool 12: class 3 pool 13: multicast pool 14: cpu pool 15: reserved Bit [4] If this bit is 1, then all the pools are assigned Bit [5] Set 1 to reset the pools that are assigned Bits [7:6] Reserved If CPU wants to reset pools again, CPU has to clear bit 5 and then set bit 5. Note: Before CPU doing so, CPU should set QCTRL (CPU Address EBA) bit 2 and bit 3 to one. After reset the pools, CPU shall reprogram free granule link list (CPU address EC1, EC2, EC3, EC4, EC5, EC6). Then clear QCTRL (EBA). 12.3.10.17 FCB_HEAD_PTR0, FCB_HEAD_PTR1 CPU address EC1 Accessed by CPU (R/W) Bits [7:0] Fcb_head_ptr[7:0]. The head pointer of free granule link that CPU assigns. CPU address EC2 Accessed by CPU (R/W) Bits [6:0] Fcb_head_ptr[14:8]. The head pointer of free granule link that CPU assigns. Bit [7] Set 1 to write If CPU wants to write again, CPU has to clear bit 15 and then set bit 15. 116 Zarlink Semiconductor Inc. ZL50410 12.3.10.18 Data Sheet FCB_TAIL_PTR0, FCB_TAIL_PTR1 CPU address EC3 Accessed by CPU (R/W) Bits [7:0] Fcb_tail_ptr[7:0]. The tail pointer of free granule link that CPU assigns. CPU address EC4 Accessed by CPU (R/W) Bits [6:0] Fcb_tail_ptr[14:8]. The tail pointer of free granule link that CPU assigns. Bit [7] Set 1 to write If CPU wants to write again, CPU has to clear bit 15 and then set bit 15. 12.3.10.19 FCB_NUM0, FCB_NUM1 CPU address EC5 Accessed by CPU (R/W) Bits [7:0] Fcb_number[7:0]. The total number of granules that CPU assigns. CPU address EC6 Accessed by CPU (R/W) Bits [6:0] Fcb_number[14:8]. The total number of granules that CPU assigns. Bit [7] Set 1 to write If CPU wants to write again, CPU has to clear bit 15 and then set bit 15. Note: There are two ways to reprogram the free granules. 1. CPU links all the granules: CPU writes memory directly, at last write head pointer (address EC1, EC2), tail pointer (address EC3, EC4) and granule number (address EC5, EC6). 2. CPU tells Buffer Manager to link: CPU clear head pointer (address EC1, EC2), clear tail pointer (address EC3, EC4), then write granule number that tells Buffer Manager to link (address EC5, EC6). 12.3.10.20 BM_RLSFF_CTRL CPU address EC7 Accessed by CPU (R/W) Bit [0] Read BM release FIFO. Bits [7:1] Reserved The information of BM release FIFO is relocated to registers BM_RLSFF_INFO (address ECD, ECC, ECB, ECA, EC9 and EC8). If the FIFO is not empty, CPU can read out the next by setting the bit 0. Read only happens when bit 0 is changing from 0 to 1. 117 Zarlink Semiconductor Inc. ZL50410 12.3.10.21 BM_RSLFF_INFO[5:0] CPU address EC8 Accessed by CPU (RO) Bits [7:0] Rls_head_ptr[7:0]. CPU address EC9 Accessed by CPU (RO) Bits [6:0] Rls_head_ptr[14:8]. Bit [7] Rls_tail_ptr[0] CPU address ECA Accessed by CPU (RO) Bits [7:0] Rls_tail_ptr[8:1] CPU address ECB Accessed by CPU (RO) Bits [5:0] Rls_tail_ptr[14:9] Bits [7:6] Rls_count[1:0] CPU address ECC Accessed by CPU (RO) Bits [4:0] Rls_count[6:2] Bit [5] If 1, then It is multicast packet. Bits [7:6] Rls_src_port[1:0[ CPU address ECD Accessed by CPU (RO) Bits [1:0] Rls_src_port[3:2] Bits [3:2] Class[1:0] Bit [4] This release request is from QM directly. Bits [7:5] Entries count in release FIFO, 0 means FIFO is empty 118 Zarlink Semiconductor Inc. Data Sheet ZL50410 12.3.11 12.3.11.1 Data Sheet (Group F Address) CPU Access Group GCR - Global Control Register CPU Address: hF00 Accessed by CPU (R/W) Bit [0]: Store configuration (Default = 0) Write ‘1’ followed by ‘0’ to store configuration into external EEPROM Bit [1]: Store configuration and reset (Default = 0) Write ‘1’ to store configuration into external EEPROM and reset chip Bit [2]: Start BIST (Default = 0) Write ‘1’ followed by ‘0’ to start the device’s built-in self-test. The result is found in the DCR register. Bit [3]: Soft Reset (Default = 0) Write ‘1’ to reset chip Bit [4]: Initialization Completed (Default = 0) This bit is reserved in unmanaged mode. In managed mode, the CPU writes this bit with ‘1’ to indicate initialization is completed and ready to forward packets. The ‘0' to '1' transition will toggle TSTOUT[2] from low to high. Bits [7:5]: 12.3.11.2 Reserved DCR - Device Status and Signature Register CPU Address: hF01 Accessed by CPU (RO) Bit [0]: 1: Busy writing configuration to I²C 0: Not busy (not writing configuration to I²C) Bit [1]: 1: Busy reading configuration from I²C 0: Not busy (not reading configuration from I²C) Bit [2]: 1: BIST in progress 0: BIST not running Bit [3]: 1: RAM Error 0: RAM OK Bits [5:4]: Device Signature 11: ZL50410 device Bits [7:6]: Revision 00: Initial Silicon 01: Second Silicon 10: Third Silicon 119 Zarlink Semiconductor Inc. ZL50410 12.3.11.3 Data Sheet DCR1 - Device Status Register 1 CPU Address: hF02 Accessed by CPU (RO) 12.3.11.4 Bits [6:0] Reserved Bit [7] Chip initialization completed DPST – Device Port Status Register CPU Address:hF03 Accessed by CPU (R/W) 12.3.11.5 Bits [4:0]: Read back index register. This is used for selecting what to read back from DTST. (Default 00) - 5’b00000 - Port 0 Operating mode and Negotiation status - 5’b00001 - Port 1 Operating mode and Negotiation status - 5’b00010 - Port 2 Operating mode and Negotiation status - 5’b00011 - Port 3 Operating mode and Negotiation status - 5’b00100 - Port 4 Operating mode and Negotiation status - 5’b00101 - Port 5 Operating mode and Negotiation status - 5’b00110 - Port 6 Operating mode and Negotiation status - 5’b00111 - Port 7 Operating mode and Negotiation status - 5’b01000 - Port CPU Operating mode and Negotiation status - 5’b01001 - Port GMAC Operating mode and Negotiation status Bits [7:5]: Reserved DTST – Data read back register CPU Address: hF04 Accessed by CPU (RO) This register provides various internal information as selected in DPST bit [4:0]. Refer to the PHY Port Control Application Note, ZLAN-37. Bit [0] Flow control enable 1: Flow control 0: No flow control Bit [1] Full duplex port 1: Full duplex 0: Half duplex Bit [2] Fast Ethernet port (if bit [5] not set) 1: FE Port Bit [3] Link is down 1: Link down 0: Link up 120 Zarlink Semiconductor Inc. ZL50410 Bit [4] Auto negotiation disabled 1: Disable 0: Enable Bit [5] Gigabit Ethernet port 1: GE Port Bit [6] Reserved Bit [7] Module detected (for hot swap purpose) 0: No module 1: Module detected Data Sheet Note: If Module Detect feature is disabled (bootstrap TSTOUT[9]=’0’), this bit will always be ‘1’. 12.3.11.6 DA – Dead or Alive Register CPU Address: hFFF Accessed by CPU (RO) Always return 8’h DA. Indicate the CPU interface or serial port connection is good. Bits [7:0] Always return DA 121 Zarlink Semiconductor Inc. ZL50410 13.0 Characteristics and Timing 13.1 Absolute Maximum Ratings Storage Temperature -65°C to +150°C Operating Temperature -40°C to +85°C Maximum Junction Temperature +125°C Supply Voltage VCC with Respect to VSS +2.95 V to +3.65 V Supply Voltage VDD with Respect to VSS +1.60 V to +2.00 V Voltage on 5 V Tolerant Input Pins -0.5 V to (VCC + 2.5 V) Voltage on Other Pins -0.5 V to (VDD + 0.3 V) Data Sheet Caution: Stress above those listed may damage the device. Exposure to the Absolute Maximum Ratings for extended periods may affect device reliability. Functionality at or above these limits is not implied. 13.2 DC Electrical Characteristics VCC = 3.3 V +/- 10% TAMBIENT = -40 C to +85 C VDD = 1.8 V +/- 5% 122 Zarlink Semiconductor Inc. ZL50410 13.3 Data Sheet Recommended Operating Conditions Symbol Parameter Description Min. Typ. Max. Unit 100 100 MHz fosc Frequency of Operation (SCLK) ICC VCC Supply Current – @ 100 MHz (full line rate) 105 mA IDD VDD Supply Current – @ 100 MHz (full line rate) 350 mA VOH Output High Voltage (CMOS) VOL Output Low Voltage (CMOS) VIH Input High Voltage (TTL 5 V tolerant) VIL 2.4 V 0.4 V VCC + 2.0 V Input Low Voltage (TTL 5 V tolerant) 0.8 V IIL Input Leakage Current (0.1 V < VIN < VCC) (all pins except those with internal pull-up/pull-down resistors) 10 µA IOL Output Leakage Current (0.1 V < VOUT < VCC) 10 µA CIN Input Capacitance 5 pF COUT Output Capacitance 5 pF CI/O I/O Capacitance 7 pF θja Thermal resistance with 0 air flow 24.3 C/W θja Thermal resistance with 1 m/s air flow 20.0 C/W θja Thermal resistance with 2 m/s air flow 18.1 C/W θjc Thermal resistance between junction and case 4.6 C/W 2.0 123 Zarlink Semiconductor Inc. ZL50410 13.4 13.4.1 Data Sheet AC Characteristics and Timing Typical Reset & Bootstrap Timing Diagram RESIN# RESETOUT# Tri-Stated R1 R3 Bootstrap Pins Outputs Inputs Outputs R2 Figure 13 - Typical Reset & Bootstrap Timing Diagram Symbol Parameter Min. R1 Delay until RESETOUT# is tri-stated R2 Bootstrap stabilization R3 RESETOUT# assertion 1 µs Typ. Note: 10 ns RESETOUT# state is then determined by the external pull-up/down resistor 10 µs Bootstrap pins sampled on rising edge of RESIN# 2 ms 124 Zarlink Semiconductor Inc. ZL50410 13.4.2 Data Sheet Typical CPU Timing Diagram for a CPU Write Cycle AD D R 0 P_A[2:0] AD D R 1 T WH TW H TW S TW S P_C S# TW A Activ e Tim e TW R R ecov ery Tim e TW A Activ e Tim e P_W E# TDH TDS P_D ATA (to dev ice) TDH T DS D ATA0 D ATA1 Set up tim e H old tim e Figure 14 - Typical CPU Timing Diagram for a CPU Write Cycle Description Write Cycle (SCLK=100 Mhz) Max. (SCLK=50 Mhz) Min. Refer to Figure 14 Symbol Min. Write Set up Time TWS 10 10 P_A and P_CS# to falling edge of P_WE# Write Active Time TWA 20 40 At least 2 SCLK cycles Write Hold Time TWH 2 2 P_A and P_CS# to rising edge of P_WE# Write Recovery time TWR 30 60 At least 3 SCLK cycles Data Set Up time TDS 10 10 P_DATA to falling edge of P_WE# Data Hold time TDH 2 2 P_DATA to rising edge of P_WE# 125 Zarlink Semiconductor Inc. Max. ZL50410 13.4.3 Data Sheet Typical CPU Timing Diagram for a CPU Read Cycle AD D R 0 P_A[2:0] AD D R 1 TRH TRS TRH T RS P_C S# TRA Activ e Tim e TRR R ecov ery Tim e TRA Activ e Tim e P_R D # TDI TDV P_D ATA (to C PU ) TDI TDV D ATA0 D ATA1 Valid tim e Inv alid tim e Figure 15 - Typical CPU Timing Diagram for a CPU Read Cycle Description Read Cycle (SCLK=100 Mhz) Max. (SCLK=50 Mhz) Min. Refer to Figure 15 Symbol Min. Max. Read Set up Time TRS 10 10 P_A and P_CS# to falling edge of P_RD# Read Active Time TRA 20 40 At least 2 SCLK cycles Read Hold Time TRH 2 2 P_A and P_CS# to rising edge of P_RD# Read Recovery time TRR 30 60 At least 3 SCLK cycles Data Valid time TDV 12 12 P_DATA to falling edge of P_RD# Data Invalid time TDI 10 10 P_DATA to rising edge of P_RD# Table 14 - AC Characteristics - CPU Read Cycle 126 Zarlink Semiconductor Inc. ZL50410 13.4.4 Data Sheet Reduced Media Independent Interface M_CLK M6-max M6-min Mn_TXEN M7-max M7-min Mn_TXD[1:0] Figure 16 - AC Characteristics – Reduced media independent Interface (TX) M_CLK M2 Mn_RXD M3 M4 Mn_CRS_DV M5 Figure 17 - AC Characteristics – Reduced Media Independent Interface (RX) M_CLK=50 MHz Symbol Parameter Note: Min. (ns) Max. (ns) M2 M[7:0]_RXD[1:0] Input Setup Time 4 M3 M[7:0]_RXD[1:0] Input Hold Time 2 M4 M[7:0]_CRS_DV Input Setup Time 4 M5 M[7:0]_CRS_DV Input Hold Time 3 M6 M[7:0]_TXEN Output Delay Time 2 11 CL = 20 pF M7 M[7:0]_TXD[1:0] Output Delay Time 2 11 CL = 20 pF 127 Zarlink Semiconductor Inc. ZL50410 13.4.5 Data Sheet Media Independent Interface Mn_TXCLK MM6-max MM6-min Mn_TXEN MM7-max MM7-min Mn _TXD[3:0] Figure 18 - AC Characteristics – Media independent Interface (TX) Mn_RXCLK MM2 Mn_RXD[3:0] MM4 Mn_CRS_DV MM 3 MM 5 Figure 19 - AC Characteristics – Media Independent Interface (RX) 25 MHz Symbol Parameter Note: Min. (ns) Max. (ns) MM2 M[9,7:0]_RXD[3:0] Input Setup Time 4 MM2 M[8]_RXD[3:0] Input Setup Time 10 MM3 Mn_RXD[3:0] Input Hold Time 2 MM4 M[9,7:0]_CRS_DV Input Setup Time 4 MM4 M[8]_CRS_DV Input Setup Time 10 MM5 Mn_CRS_DV Input Hold Time 2 MM6 Mn_TXEN Output Delay Time 2 14 CL = 20 pF MM7 Mn_TXD[3:0] Output Delay Time 2 14 CL = 20 pF 128 Zarlink Semiconductor Inc. CPU MII Interface CPU MII Interface ZL50410 13.4.6 Data Sheet General Purpose Serial Interface (7-wire) Mn_ TXCLK SM6-max SM6-min Mn_TXEN SM7-max SM7-min Mn_TXD Figure 20 - AC Characteristics – General Purpose Serial Interface (TX) Mn_RXCLK SM2 Mn_RXD SM3 SM4 Mn_CRS_DV SM5 Figure 21 - AC Characteristics – General Purpose Serial Interface (RX) 10 MHz Symbol Parameter Note: Min. (ns) Max. (ns) SM2 M[7:0]_RXD Input Setup Time 4 SM3 M[7:0]_RXD Input Hold Time 2 SM4 M[7:0]_CRS_DV Input Setup Time 4 SM5 M[7:0]_CRS_DV Input Hold Time 2 SM6 M[7:0]_TXEN Output Delay Time 2 14 CL = 20 pF SM7 M[7:0]_TXD Output Delay Time 2 14 CL = 20 pF 129 Zarlink Semiconductor Inc. ZL50410 13.4.7 Data Sheet Gigabit Media Independent Interface M9_TXCLK G12-max G12-min M9_TXD [7:0] G13-max G13-min M9_TXEN G14-max G14-min M9_TXER Figure 22 - AC Characteristics- Gigabit Media Independent Interface (TX) M9_RXCLK M9_RXCLK G1 G2 M9_RXD[7:0] M9_RXD[7:0] G3 G4 M9_RXDV M9_RXDV G5 G6 M9_RXER M9_RXER G7 G8 M9_RX_CRS M9_RX_CRS Figure 23 - AC Characteristics – Gigabit Media Independent Interface (RX) 130 Zarlink Semiconductor Inc. ZL50410 Data Sheet 125 Mhz Symbol Parameter Note: Min. (ns) Max. (ns) G1 M9_RXD[7:0] Input Setup Times 2 G2 M9_RXD[7:0] Input Hold Times 1 G3 M9_RXDV Input Setup Times 2 G4 M9_RXDV Input Hold Times 1 G5 M9_RXER Input Setup Times 2 G6 M9_RXER Input Hold Times 1 G7 M9_CRS Input Setup Times 2 G8 M9_CRS Input Hold Times 1 G12 M9_TXD[7:0] Output Delay Times 1 6 CL = 20 pf G13 M9_TXEN Output Delay Times 1 6.5 CL = 20 pf G14 M9_TXER Output Delay Times 1 6 CL = 20 pf 131 Zarlink Semiconductor Inc. ZL50410 13.4.8 Data Sheet MDIO Input Setup and Hold Timing MDC D1 D2 MDIO Figure 24 - MDIO Input Setup and Hold Timing MDC D3-max D3-min MDIO Figure 25 - MDIO Output Delay Timing MDC=500 KHz Symbol Parameter Note: Min. (ns) D1 MDIO input setup time 10 D2 MDIO input hold time 2 D3 MDIO output delay time 1 132 Zarlink Semiconductor Inc. Max. (ns) 20 CL = 50 pf ZL50410 13.4.9 Data Sheet I²C Input Setup Timing SCL S2 S1 SDA Figure 26 - I²C Input Setup Timing SCL S3-max S3-min SDA Figure 27 - I²C Output Delay Timing SCL=50 KHz Symbol Parameter Note: Min. (ns) S1 SDA input setup time 20 S2 SDA input hold time 1 S3* SDA output delay time 4 usec Max. (ns) 6 usec * Open Drain Output. Low to High transistor is controlled by external pullup resistor. 133 Zarlink Semiconductor Inc. CL = 30 pf ZL50410 13.4.10 Data Sheet Serial Interface Setup Timing STROBE D4 D1 Datain D5 D2 D1 D2 Figure 28 - Serial Interface Setup Timing STROBE D3-max D3-min Dataout Figure 29 - Serial Interface Output Delay Timing Symbol Parameter Min. (ns) Max. (ns) Note: D1 DATAIN setup time 20 D2 DATAIN hold time 3 µs Debounce on 20 ns Debounce off D3 DATAOUT output delay time D4 STROBE low time D5 1 STROBE high time 134 Zarlink Semiconductor Inc. 50 CL = 100 pf 5 µs Debounce on 50 ns Debounce off 5 µs Debounce on 50 ns Debounce off ZL50410 13.4.11 Data Sheet JTAG (IEEE 1149.1-2001) TCK TMS, TDI J1 J2 J3-max TDO J3-min Figure 30 - JTAG Timing Diagram Symbol Parameter Min. Typ. Max. Units TCK frequency of operation 0 10 50 MHz TCK cycle time 20 ns TCK clock pulse width 10 ns TRST# assert time 20 J1 TMS, TDI data setup time 3 ns J2 TMS, TDI data hold time 7 ns J3 TCK to TDO data valid 0 135 Zarlink Semiconductor Inc. - 15 ns ns Note: TRST is an asynchronous signal ZL50410 14.0 Document History 14.1 July 2003 • Initial Release 14.2 • • • • • • • • • • • • • • • • August 2004 Added Errata List to document Added section on SCL clock generation Interrupt Register was incorrectly identified as read only, should be read/write • Clarified that only bit [7] is not self-clearing Updated CPU timing diagrams to clarify timing 14.5 • • • February 2004 Added the following to the Feature List: • 4 K jumbo frames • IEEE 802.3ad support • Reverse MII/GPSI Added section on PHY addresses • Clarified that they are hard-coded Fixed error in DS on sending Ethernet Frames via 8/16-bit or serial interface. • The Status Bytes is sent before the frame, for both Tx and Rx Added more cross-references to available AppNotes Added section on Stacked VLAN (Q-in-Q) and IP Multicast Switching since they weren’t really discussed in the DS Added more clock descriptions to “Clocks” on page 50 INT_MASK and INTP_MASK registers should state that the default register value is 0x00 14.4 • • • November 2003 Clarified IP Multicast support is up to 4 K groups, as it wasn’t mentioned in the data sheets Updated Ball Signal Description Table: • clarified the ball signal I/O description for Mn_TXCLK & Mn_RXCLK showing these signals are either inputs OR outputs • clarified that M9_MTXCLK is an input only Updated Section 1.4 on page 17 to indicate operation of the internal pull-up/down resistors in different modes Clarified Section 10.1.3 on page 50 on usage of GREF_CLK Clarified PVMODE register bit description for bits [2] & [5] Updated ECR4Pn register description as port 9 (uplink) operates differently than the RMAC ports for MII bi-directional clocking (bits [1:0]) I2C address mapping was corrected for QOSCn registers Added Maximum Junction Temperature to Section 13.1 on page 122 Updated I/O voltage levels to use TTL spec values rather than % of Vcc 14.3 • Data Sheet November 2004 Added section “Default Switch Configuration and Initialization Sequence” on page 21 Added Private VLAN Edge (protected ports), force VLAN tag out, and unknown IP Multicast filtering support Updated CPU timing diagrams to clarify P_A timing 136 Zarlink Semiconductor Inc. BOTTOM VIEW TOP VIEW MIN MAX Dimension 1.40 A A1 0.30 0.50 0.53 REF A2 D 16.90 17.10 16.90 17.10 E 0.40 0.60 b 1.00 e N 208 Conforms to JEDEC MO-192 b SIDE VIEW Package Code c Zarlink Semiconductor 2002 All rights reserved. ISSUE 1 ACN 213730 DATE 14Nov02 APPRD. Previous package codes For more information about all Zarlink products visit our Web Site at www.zarlink.com Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request. Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system conforms to the I2C Standard Specification as defined by Philips. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright Zarlink Semiconductor Inc. All Rights Reserved. TECHNICAL DOCUMENTATION - NOT FOR RESALE