Features
•
•
•
•
•
15 Amp
Schottky
Meatl of Silicon Rectifier, Majority Conducton
Guard ring for transient protection
Low Forward Voltage Drop
High Current Capability, High Efficiency
Low Power Loss
Barrier Rectifier
20 to 100 Volts
Maximum Ratings
•
•
TO-220AB
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +175°C
Catalog
Number
MBR1520CT
MBR1530CT
MBR1535CT
MBR1540CT
MBR1545CT
MBR1560CT
MBR1580CT
MBR15100CT
Maximum
Recurrent
Peak Reverse
Voltage
20V
30V
35V
40V
45V
60V
80V
100V
B
Maximum
RMS
Voltage
14V
21V
24.5V
28V
31.5V
42V
56V
70V
C
IF(AV)
15 A
TC = 125°C
IFSM
150A
8.3ms, half sine
VF
.84V
.90V
.95V
IR
0.1mA
1.0mA
15mA
50mA
100mA
IFM = 15A;
TJ = 25°C
I FM = 16A
TJ = 25°C
D
A
K
2
3
F
G
I
J
N
H H
PIN 1
PIN 2
CASE
PIN 3
A
B
C
D
E
F
G
H
I
J
K
L
M
N
INCHES
.560
.625
.380
.420
.100
.135
.230
.270
.380
.420
-----.250
.500
.580
.090
.110
.020
.045
.012
.025
.139
.161
.140
.190
.045
.055
.080
.115
TJ = 125°C
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
E
PIN
1
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
1520CT-45CT
1560CT
1580CT-100CT
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
1520CT-45CT
1560CT-100CT
1520CT-45CT
1560CT
1580CT-100CT
L
M
Maximum
DC
Blocking
Voltage
20V
30V
35V
40V
45V
60V
80V
100V
www.cnelectr.com
MM
14.22
9.65
2.54
5.84
9.65
-----12.70
2.29
0.51
0.30
3.53
3.56
1.14
2.03
15.88
10.67
3.43
6.86
10.67
6.35
14.73
2.79
1.14
0.64
4.09
4.83
1.40
2.92
MBR1520CT thru MBR15100CT
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
10
100
1560CT
60
6
4
40
2
20
1520CT-1545CT
1
10
.6
6
.4
4
1580-15100CT
.2
2
TJ=25°C
25°C
mAmps .1
Amps 1
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.004
4
.04
.002
.02
.001
20
.01
.3
.4
.5
.6
.7
75
50
100
125 150
175
.8
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
15
150
13
125
11
100
75
9
Amps
Amps
50
7
25
5
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
125
1
2
4
8 10
20
40
60 80 100
Cycles
150
°C
6
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C