LBA120
DUAL POLE OptoMOS® Relay
Load Voltage
Load Current
Max RON
LBA120
250
170
20
Description
LBA120 is 250V, 170mA, 20Ω independent 1-Form-A and
1-Form-B relays. It features low on-resistance combined
with enhanced peak load current handling capabilities.
Current limiting version is available (“L” suffix, see specification for variations in performance).
Units
V
mA
Ω
Features
• Small 8 Pin DIP Package
• Low Drive Power Requirements (TTL/CMOS
Compatible)
• No Moving Parts
• High Reliability
• Arc-Free With No Snubbing Circuits
• 3750VRMS Input/Output Isolation
• FCC Compatible
• VDE Compatible
• No EMI/RFI Generation
• Machine Insertable, Wave Solderable
• Surface Mount and Tape & Reel
Versions Available
Approvals
• UL Recognized: File Number E76270
• CSA Certified: File Number LR 43639-10
• BSI Certified to:
• BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
• BS EN 41003:1993
Certificate #: 7344
Ordering Information
Applications
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook, Pocket Size)
• Hookswitch
• Dial Pulsing
• Ground Start
• Ringer Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment-Patient/Equipment Isolation
• Security
• Aerospace
• Industrial Controls
Part #
LBA120
LBA120P
LBA120PTR
LBA120S
LBA120STR
Description
8 Pin DIP (50/Tube)
8 Pin Flatpack (50/Tube)
8 Pin Flatpack (1000/Reel)
8 Pin Surface Mount (50/Tube)
8 Pin Surface Mount (1000/Reel)
Pin Configuration
LBA120 Pinout
AC/DC Configuration
+ Control - Normally Closed
– Control - Normally Closed
+ Control - Normally Open
– Control - Normally Open
1
8
2
7
3
6
4
5
Switching Characteristics of
Normally Open (Form A) Devices
Normally Closed Pole
Normally Open Pole
Switching Characteristics of
Normally Closed (Form B) Devices
10ms
10ms
CONTROL
CONTROL
+90%
+
90%
LOAD
10%+
10%+
TON
DS-LBA120-R5
www.clare.com
TOFF
+
90%
+10%
TOFF
TON
1
LBA120
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Min
Input Power Dissipation
-
-
1501
mW
Input Control Current
Peak (10ms)
-
-
50
1
mA
A
Reverse Input Voltage
-
-
5
V
Total Power Dissipation
-
-
8002
mW
Isolation Voltage
Input to Output
3750
-
-
VRMS
Operational Temperature
-40
-
+85
°C
Storage Temperature
-40
-
+125
°C
-
-
+260
+220
°C
°C
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/˚C
2
Derate Linearly 6.67 mw/˚C
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Typ Max Units
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Load Voltage (Peak)
-
VL
-
-
250
V
Load Current*(Continuous)
AC/DC Configuration
-
IL
-
-
170
mA
10ms
ILPK
-
-
400
mA
IL=170mA
VL=250V
RON
ILEAK
-
16
-
20
1
Ω
µA
Switching Speeds
Turn-On
Turn-Off
IF=5mA, VL=10V
IF=5mA, VL=10V
TON
TOFF
-
-
5
5
ms
ms
Output Capacitance
50V; f=1MHz
COUT
-
50
-
pF
Input Control Current
IL=120mA
IF
5
-
50
mA
Input Dropout Current
-
-
0.4
0.7
-
mA
Output Characteristics @ 25°C
Peak Load Current
On-Resistance
AC/DC Configuration
Off-State Leakage Current
Input Characteristics @ 25°C
Input Voltage Drop
IF=5mA
VF
0.9
1.2
1.4
V
Reverse Input Voltage
-
VR
-
-
5
V
Reverse Input Current
VR=5V
IR
-
-
10
µA
Input to Output Capacitance
-
CI/O
-
3
-
pF
Input to Output Isolation
-
VI/O
3750
-
-
VRMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
2
www.clare.com
Rev. 5
LBA120
PERFORMANCE DATA*
35
30
30
25
20
15
10
20
15
10
5
0
0
1.19
1.21
1.23
9.05
9.35
9.65
9.95
9.25 10.15 11.05 11.95 12.85 13.75 14.65
10.25
On-Resistance (Ω)
LBA120 - FormA
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
LBA120 - FormB
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
30
25
30
25
20
25
20
15
10
20
15
10
5
5
0
0
330
340
350
360
370
380
Device Count (N)
35
Device Count (N)
Device Count (N)
10
On-Resistance (Ω)
LBA120 - FormA
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
390
280
20
15
10
331
348
0.1
365
20
15
10
0
0.64
0.3
LED Current (mA)
0.5
0.7
0.9
1.1
1.3
0.16
Device Count (N)
20
Device Count (N)
25
20
15
10
5
1.38
Turn-On (ms)
1.62
1.86
0.40
0.48
0.56
0.64
15
10
5
0
0
1.14
0.32
LBA120 - FormA
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
LBA120 - FormB
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
25
0.90
0.24
LED Current (mA)
30
0
1.3
5
20
5
1.1
10
25
10
0.9
15
LED Current (mA)
15
0.7
0
0.1
LBA120 - FormA
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
0.5
LBA120 - FormB
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
20
0
0.66
0.3
LED Current (mA)
25
5
0.56
314
25
5
0.48
297
Device Count (N)
Device Count (N)
25
0.40
5
LBA120 - FormA
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
30
0.32
10
Blocking Voltage (V)
LBA120 - FormB
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
0.24
15
0
263
Blocking Voltage (V)
Device Count (N)
15
0
8.75
LED Forward Voltage Drop (V)
Device Count (N)
20
5
8.45
1.25
30
LBA120 - FormB
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC, IF=5mADC)
25
25
5
1.17
LBA120 - FormA
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC, IF=5mADC)
Device Count (N)
35
Device Count (N)
Device Count (N)
LBA120
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C; IF = 5mADC)
0.04
0.12
0.20
0.28
0.36
Turn-On (ms)
0.44
0.08
0.16
0.24
0.32
0.40
0.23
Turn-Off (ms)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 5
www.clare.com
3
LBA120
PERFORMANCE DATA*
LBA120 - Form A
Typical Load Current vs. Temperature
250
25
200
200
20
15
10
20mA
10mA
5mA
150
100
50
0
0
0.75
1.25
1.75
2.25
2.75
-20
0
20
0.020
0.015
0.010
0.005
0
40
80
100
-40
60
80
100
0
20
-20
0
20
40
40
60
80
100
120
Temperature (°C)
375
370
365
360
355
350
345
340
335
330
325
-40
LBA120 - FormB
Typical Blocking Voltage vs. Temperature
60
80
100
325
320
315
310
305
300
295
290
285
280
275
-40
-20
0
20
40
60
80
100
Temperature (°C)
Temperature (°C)
LBA120 - FormA
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
LBA120 - FormB
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
LBA120 - FormA
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
20mA
0.40
0.8
0.35
0.7
0.30
0.6
Turn-Off (ms)
10mA
Turn-On (ms)5mA
5mA
0.25
0.20
0.15
0.10
5mA
0.05
-20
0
20
40
60
80
-20
0
3.0
5mA
2.5
10mA
20mA
1.5
1.0
0.5
0
20
40
60
Temperature (°C)
80
100
LED Forward Voltage Drop (V)
3.5
0
20
40
60
80
0.2
100
5mA
-40
-20
0
20
40
60
80
100
Temperature (°C)
LBA120
Typical LED Forward Voltage Drop
vs. Temperature
LBA120 - FormB
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
-20
0.3
Temperature (°C)
Temperature (°C)
2.0
0.4
0
-40
100
0.5
0.1
0
-40
-20
Temperature (°C)
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-40
50
120
LBA120 - FormA
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
1.8
1.4
1.6
1.2
Turn-On (ms)
Leakage (µA)
0.025
20
60
Blocking Voltage (VRMS)
Blocking Voltage (VRMS)
0.030
0
40
LBA120 - FormA
Typical Blocking Voltage vs. Temperature
0.035
-20
5mA
100
Temperature (°C)
LBA120
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
-40
150
0
-40
3.25
Turn-Off (ms)
Turn-On (ms)
Load Current (mA)
250
5
Turn-Off (ms)
LBA120 - Form B
Typical Load Current vs. Temperature
30
Load Current (mA)
Device Count (N)
LBA120 - FormB
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
1.4
50mA
30mA
20mA
10mA
5mA
1.2
1.0
1.0
0.8
0.6
0.4
0.8
0.2
-40
-20
0
20
40
60
80
Temperature (°C)
100
120
0
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
4
www.clare.com
Rev. 5
LBA120
PERFORMANCE DATA*
Turn-Off (ms)
Turn-On (ms)
0.4
0.42
2.0
0.41
1.8
1.6
Turn-Off (ms)
0.8
0.6
LBA120 - FormB
Typical Turn-Off vs. LED Forward Current
(Load Current = 170mADC)
LBA120 - FormA
Typical Turn-Off vs. LED Forward Current
(Load Current = 170mADC)
LBA120 - FormB
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
0.40
0.39
0.38
1.4
1.2
1.0
0.2
0.37
0
0
5
10
15
20
25
30
35
40
45
0.6
0
50
5
10
15
30
35
40
45
0
50
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
LBA120 - FormA
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; IF = 5mADC)
LBA120 - FormB
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; IF = 5mADC)
LBA120 - FormA
Typical IF for Switch Operation vs. Temperature
(Load Current = 170mADC)
60
50
50
40
30
20
1.8
1.6
LED Current (mA)
60
40
30
20
10
0
-20
0
20
40
60
80
100
-20
0
20
40
60
80
1.500
1.000
0.500
80
1.2
1.0
0.8
0.6
0.4
-20
0
20
40
60
80
LBA120 - FormB
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C; IF = 5mADC)
1.0
1.0
-100
Load Current (A)
150
Load Current (mA)
150
50
0
-50
-100
20
40
60
80
100
0.8
0.6
0.4
0.2
-150
-150
-200
-2.5 -2.0 -1.5 -1.0 -0.5
-200
-2.5 -2.0 -1.5 -1.0 -0.5
0.5 1.0 1.5 2.0 2.5
0
LBA120
Energy Rating Curve
1.2
100
-20
Temperature (°C)
200
-50
100
1.5
200
0
80
2.0
-40
100
LBA120 - FormA
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C; IF = 5mADC)
50
60
0
-40
Temperature (°C)
100
40
0.5
0
100
20
2.5
1.4
Temperature (°C)
Load Voltage (V)
0
3.0
0.2
0
0
-20
LBA120 - FormB
Typical IF for Switch Dropout vs. Temperature
(Load Current = 170mADC)
LED Current (mA)
LED Current (mA)
2.000
60
0.4
Temperature (°C)
1.6
40
0.6
-40
1.8
2.500
20
0.8
100
LBA120 - FormA
Typical IF for Switch Dropout vs. Temperature
(Load Current = 170mADC)
3.000
0
1.0
Temperature (°C)
LBA120 - FormB
Typical IF for Switch Operation vs. Temperature
(Load Current = 170mADC)
-20
1.2
0
-40
Temperature (°C)
-40
1.4
0.2
0
-40
LED Current (mA)
25
LED Forward Current (mA)
10
Load Current (mA)
20
LED Forward Current (mA)
On-Resistance (Ω)
On-Resistance (Ω)
0.8
0.36
0
0.5 1.0 1.5 2.0 2.5
Load Voltage (V)
0
10µs 100µs 1ms 10ms 100ms
1s
10s 100s
Time
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 5
www.clare.com
5
LBA120
Mechanical Dimensions
9.652 ± .381
(.380 ± .015)
8 Pin DIP Through Hole (Standard)
7.620 ± .254
(.300 ± .010)
7.239 TYP.
(.285)
PC Board Pattern
(Top View)
2.540 ± .127
(.100 ± .005)
3.302
(.130)
9.144 ± .508
(.360 ± .020)
6.350 ± .127
(.250 ± .005)
9.144 TYP.
(.360)
2.540 ± .127
8-.800 DIA. (.100 ± .005)
(8-.031 DIA.)
.457 ± .076
(.018 ± .003)
7.620 ± .127
(.300 ± .005)
8.077 ± .127
(.318 ± .005 )
3.302
(.130)
.254 TYP.
(.010)
8.305 ± .127
(.327 ± .005)
9.525 ± .254
(.375 ± .010)
6.350 ± .127
(.250 ± .005)
.635 TYP.
(.025)
(.100 ± .005)
2.540 ± .127
(.100 ± .005)
7.620 ± .254
(.300 ± .010)
4.445 ± .127
(.175 ± .005)
PC Board Pattern
(Top View)
2.540 ± .127
9.652 ± .381
(.380 ± .015)
8 Pin DIP Surface Mount (“S” Suffix)
7.620 ± .127
(.300 ± .005)
6.350 ± .127
(.250 ± .005)
1.905 ± .127
(.075 ± .005)
.457 ± .076
(.018 ± .003)
1.498 ± .127
(.059 ± .005)
8.077 ± .127
(.318 ± .005)
9.652 ± .381
(.380 ± .015)
2.540 ± .127
(.100 ± .005)
8 Pin Flatpack (“P” Suffix)
2.159 TYP.
(.085)
PC Board Pattern
(Top View)
2.540 ± .127
(.100 ± .005)
7.620 ± .254
(.300 ± .010)
2.286 MAX.
.635 ± .127
(.090)
(.025)
6.350 ± .127
(.250 ± .005)
9.398 ± .127
(.370 ± .005)
8.763 ± .127
(.345 ± .005)
.203
(.008)
.457 ± .076
(.018 ± .003)
1.193
(.047)
8.077 ± .127
(.318 ± .005)
.787
(.031)
Dimensions
mm
(inches)
6
www.clare.com
Rev. 5
LBA120
Mechanical Dimensions
Tape and Reel Packaging for 8 Pin Surface Mount Package
330.2 DIA.
(13.00)
6.731 MAX.
1.753 ± .102
(.265)
(.069 ± .004)
.406 MAX.
(.016)
Top Cover
Tape Thickness
.102 MAX.
(.004)
2.007 ± .102 1.498 ± .102 3.987 ± .102
(.079 ± .004) (.059 ± .004) (.157 ± .004)
7.493 ± .102
(.295 ± .004)
1
8
12.090
(.476)
10.300
(.405)
4.877
(.192)
Top Cover
Tape
Embossed Carrier
16.002 ± .305
(.630 ± .012)
.050R TYP.
11.989 ± .102
(.472 ± .004)
10.300 ± .102
(.405 ± .004)
1.549 ± .102
(.061 ± .004)
User Direction of Feed
Embossment
Tape and Reel Packaging for 8 Pin Flatpack Package
330.2 DIA.
(13.00)
Top Cover
Tape Thickness
.102 MAX.
(.004)
6.731 MAX.
1.753 ± 0.102
(.265)
(.069 ± .004)
.406 MAX.
(.016)
2.007 ± .102 1.498 ± .102 3.987 ± .102
(.079 ± .004) (.059 ± .004) (.157 ± .004)
7.493 ± .102
(.295 ± .004)
1
8
12.090
(.476)
10.287
(.405)
4.877
(.192)
Top Cover
Tape
Embossed Carrier
Embossment
16.002 ± .305
(.630 ± .012)
.050R TYP.
11.988 ± .102
(.472 ± .004)
10.287 ± .102
(.405 ± .004)
1.549 ± .102
(.061 ± .004)
User Direction of Feed
Dimensions
mm
(inches)
Rev. 5
www.clare.com
7
Worldwide Sales Offices
CLARE LOCATIONS
EUROPE
ASIA/PACIFIC
Clare Headquarters
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
European Headquarters
CP Clare nv
Bampslaan 17
B-3500 Hasselt (Belgium)
Tel: 32-11-300868
Fax: 32-11-300890
Clare Micronix Division
145 Columbia
Aliso Viejo, CA 92656-1490
Tel: 1-949-831-4622
Fax: 1-949-831-4628
France
Clare France Sales
Lead Rep
99 route de Versailles
91160 Champlan
France
Tel: 33 1 69 79 93 50
Fax: 33 1 69 79 93 59
Asian Headquarters
Clare
Room N1016, Chia-Hsin, Bldg II,
10F, No. 96, Sec. 2
Chung Shan North Road
Taipei, Taiwan R.O.C.
Tel: 886-2-2523-6368
Fax: 886-2-2523-6369
SALES OFFICES
AMERICAS
Americas Headquarters
Clare
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
Eastern Region
Clare
P.O. Box 856
Mahwah, NJ 07430
Tel: 1-201-236-0101
Fax: 1-201-236-8685
Toll Free: 1-800-27-CLARE
Central Region
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Western Region
Clare
1852 West 11th Street, #348
Tracy, CA 95376
Tel: 1-209-832-4367
Fax: 1-209-832-4732
Toll Free: 1-800-27-CLARE
Canada
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Germany
Clare Germany Sales
ActiveComp Electronic GmbH
Mitterstrasse 12
85077 Manching
Germany
Tel: 49 8459 3214 10
Fax: 49 8459 3214 29
Italy
C.L.A.R.E.s.a.s.
Via C. Colombo 10/A
I-20066 Melzo (Milano)
Tel: 39-02-95737160
Fax: 39-02-95738829
Sweden
Clare Sales
Comptronic AB
Box 167
S-16329 Spånga
Tel: 46-862-10370
Fax: 46-862-10371
United Kingdom
Clare UK Sales
Marco Polo House
Cook Way
Bindon Road
Taunton
UK-Somerset TA2 6BG
Tel: 44-1-823 352541
Fax: 44-1-823 352797
http://www.clare.com
Clare cannot assume responsibility for use of any circuitry other
than circuitry entirely embodied in this Clare product. No circuit
patent licenses nor indemnity are expressed or implied. Clare
reserves the right to change the specification and circuitry, without notice at any time. The products described in this document
are not intended for use in medical implantation or other direct life
support applications where malfunction may result in direct physical harm, injury or death to a person.
Specification: DS-LBA120-R5
©Copyright 2000, Clare, Inc.
OptoMOS® is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
2/13/01