CLARE PM1206_10

PM1206
AC Power Switch
Parameter
AC Operating Voltage
Load Current
On-State Voltage Drop
(IL=500mArms)
Rating
260
500
1.4
Features
• Load Current up to 0.5Arms
• Blocking Voltages up to 600VP
• 5mA Sensitivity
• Zero-Crossing Detection
• DC Control, AC Output
• Optically Isolated
• TTL and CMOS Compatible
• Low EMI and RFI Generation
• High Noise Immunity
• VDE compatible
• Machine Insertable, Wave Solderable
Units
Vrms
mArms
Vrms
Description
The PM1206 is an AC Solid State Switch using optical
coupling with dual power SCR outputs to produce
an alternative to optocoupler and Triac circuits. The
PM1206 switches are robust enough to provide a
blocking voltage of up to 600VP. In addition, tightly
controlled zero-cross circuitry ensures switching of
AC loads without the generation of transients. The
input and output circuits are optically coupled to
provide 3750Vrms of isolation and noise immunity
between control and load circuits. As a result, the
PM1206 is well suited for industrial environments
where electromagnetic interference could disrupt the
operation of electromechanical relays.
Approvals
• UL Recognized Component: UL 508 File E69938
• CSA Certified Component: Certificate LR43639-8
Ordering Information
Applications
• Programmable Control
• Process Control
• Power Control Panels
• Remote Switching
• Gas Pump Electronics
• Contactors
• Large Relays
• Solenoids
• Motors
• Heaters
Part #
PM1206
PM1206S
PM1206STR
Description
6-Lead DIP (50/Tube)
6-Lead Surface Mount (50/Tube)
6-Lead Surface Mount (1000/Reel)
Pin Configuration
1
– LED
2
3
Pb
RoHS
2002/95/EC
DS-PM1206-R08
6
+ LED
ZC
5
AC Load
AC Load
4
e3
www.clare.com
1
PM1206
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
Derate Linearly 1.33 mW / ºC
2
Derate Linearly 6.67 mW / ºC
Min
3750
-40
-40
Max
600
5
100
1
150
800
+85
+125
Units
VP
V
mA
A
mW
mW
Vrms
ºC
ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
AC Operating Voltage
Load Current (Continuous)
Maximum Surge Current
Off-State Leakage Current
On-State Voltage Drop
Critical Rate of Rise
Switching Speeds
Turn-On
Turn-Off
Zero-Cross Turn-On Voltage
Operating Frequency 1
Load Power Factor for Guaranteed Turn-On 2
Capacitance Input-To-Output
Input Characteristics
Input Control Current
For Normal Environment
For High Noise Environment
Input Voltage Drop
Input Dropout Voltage
Reverse Input Current
1
2
2
Conditions
Symbol
Min
Typ
Max
Units
IF=5mA
VL=120-240VAC
t<16ms
VL=600VDC
IL=0.5Arms
-
VOP
IL
IPEAK
ILEAK
dV/dt
20
0.005
1000
1200
260
0.5
12
1
1.4
-
Vrms
Arms
A
mA
Vrms
V/µs
IF=5mA
ton
toff
20
0.25
-
2
3
0.5
0.5
5
1
500
-
0.9
0.8
-
1.2
-
5
10
1.4
10
1st half-cycle
Subsequent half-cycle
-
IF=5mA
VR=5V
PF
CI/O
IF
VF
IR
Cycles
V
V
Hz
pF
mA
V
V
µA
Zero Cross 1st half-cycle @ < 100Hz.
Snubber circuits may be required at low power factors.
www.clare.com
R08
PM1206
PERFORMANCE DATA*
PM1206
Load Current, Free Air
1.2
1.3
1.0
0.8
RθJA = 60ºC/W
0.6
0.4
0.2
0
-40
20
Forward Voltage (V)
25
Peak Surge Current (A)
Load Current (Arms)
PM1206
Typical Forward Voltage vs. Temperature
PM1206
Max Surge Current (Non-Repetitive)
NOTE: Values apply to
TJ=50ºC before surge.
15
10
5
85
1.1
1.0
0.9
0
0
55
Ambient Temperature (ºC)
1.2
16
50
100
Pulse Duration (ms)
PM1206
Typical dV/dt vs. Temperature
0
10
25
40
55
70
85
Ambient Temperature (ºC)
PM1206
dV/dt Method
Critical Rate of Rise (V/μs)
1400
1200
Vo
1000
800
Vo = 300V
63%
dV 0.63 x 300V 189
=
=
dt
RC
RC
In accordance with
EIA/NARM Standards
RS-443 for Solid State Relays
600
400
200
0
10%
0
25
50
Ambient Temperature (ºC)
85
RC
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R08
www.clare.com
3
PM1206
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. Clare classified all
of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry
standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to
the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled
according to the limitations and information in that standard as well as to any limitations set forth in the information or
standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Rating
PM1206
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device
Maximum Temperature x Time
PM1206
250ºC for 30 seconds
Board Wash
Clare recommends the use of no-clean flux formulations. However, board washing to remove flux residue is
acceptable. Since Clare employs the use of silicone coating as an optical waveguide in many of its optically isolated
products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes.
Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy
should not be used.
Pb
4
RoHS
2002/95/EC
e3
www.clare.com
R08
PM1206
MECHANICAL DIMENSIONS
PM1206
3.302 ± 0.051
(0.130 ± 0.002)
2.540 ± 0.127
(0.100 ± 0.005)
7.620 ± 0.254
(0.300 ± 0.010)
6.350 ± 0.127
(0.250 ± 0.005)
9.144 ± 0.508
(0.360 ± 0.020)
PCB Hole Pattern
2.540 ± 0.127
(0.100 ± 0.005)
6 - 0.800 DIA.
(6 - 0.031 DIA.)
7.620 ± 0.127
(0.300 ± 0.005)
0.254 TYP.
(0.010 TYP.)
9.652 ± 0.381
(0.380 ± 0.015)
7.239 TYP.
(0.285 TYP.)
6.350 ± 0.127
(0.250 ± 0.005)
5.080 ± 0.127
(0.200 ± 0.005)
4.064 TYP.
(0.160 TYP.)
0.457 ± 0.076
(0.018 ± 0.003)
Dimensions
mm
(inches)
2.007 ± 0.102
(0.079 ± 0.004)
PM1206S
9.525 ± 0.254
(0.375 ± 0.010)
2.540 ± 0.127
(0.100 ± 0.005)
2.54
(0.10)
6.350 ± 0.127
(0.250 ± 0.005)
7.620 ± 0.254
(0.300 ± 0.010)
0.457 ± 0.076
(0.018 ± 0.003)
9.652 ± 0.381
(0.380 ± 0.015)
3.302 ± 0.051
(0.130 ± 0.002)
PCB Land Pattern
0.254 ± 0.0127
(0.010 ± 0.0005)
0.65
(0.0256)
0.635 ± 0.127
(0.025 ± 0.005)
1.65
(0.065)
4.445 ± 0.127
(0.175 ± 0.005)
Dimensions
mm
(inches)
2.159 ± 0.102
(0.085 ± 0.004)
R08
8.90
(0.350)
www.clare.com
5
PM1206
PM1206S Tape & Reel
330.2 DIA.
(13.00 DIA.)
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
K0 =4.90
(0.193)
K1 =4.20
(0.165)
Embossed Carrier
Embossment
W=16.00
(0.63)
Bo=10.30
(0.406)
Ao=10.30
(0.406)
P=12.00
(0.472)
User Direction of Feed
Dimensions
mm
(inches)
NOTES:
1. Dimensions carry tolerances of EIA Standard 481-2
2. Tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
For additional information please visit our website at: www.clare.com
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications
and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of
Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability,
fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental
damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice.
Specification: DS-PM1206-R08
©Copyright 2010, Clare, Inc.
All rights reserved. Printed in USA.
8/6/2010
6