Parameter
AC Operating Voltage
Load Current
On-State Voltage Drop
Blocking Voltage
Rating
20 - 240
3
0.8
800
Units
Vrms
Arms
Vrms (at IL = 3Arms)
VP
Features
•
•
•
•
•
•
•
•
•
•
•
•
Load Current up to 3Arms
800VP Blocking Voltage
5mA Sensitivity
5000Vrms Input to Output Isolation
Off-State dV/dt: 1000V/s Minimum
12.5mm External Creepage Distance with
Appropriate Layout
Zero-Cross Switching
DC Control, AC Output
Optically Isolated
TTL and CMOS Compatible
Low EMI and RFI Generation
High Noise Immunity
Description
CPC1966B is an AC Solid State Switch utilizing
dual power SCR outputs. This device also includes
zero-cross turn-on circuitry and is specified with a
blocking voltage of 800VP .
In addition, the tightly controlled zero-cross circuitry
ensures low noise switching of AC loads by
minimizing the generation of transients. The optically
coupled input and output circuits provide 5000Vrms of
isolation and noise immunity between the control and
load circuits. As a result, the CPC1966B is well suited
for industrial environments where electromagnetic
interference would disrupt the operation of plant facility
communication and control systems.
Approvals
• UL 508: Pending
• CSA Industrial Control Switches Approval: Pending
Ordering Information
Part #
CPC1966B
Applications
•
•
•
•
•
•
•
•
•
•
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Description
8-Pin Power SOIC (25/Tube)
Pin Configuration
8
AC Load
7
RoHS
2002/95/EC
DS-CPC1966B-R02
AC Load
5
ZC
1
N/C
Pb
6
2
+ LED
3
– LED
4
N/C
e3
www.ixysic.com
1
INTEGRATED CIRCUITS DIVISION
CPC1966B
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage (VDRM)
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage Input to Output
ESD, Human Body Model
Operational Temperature
Storage Temperature
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 20 mW / ºC
Ratings
800
5
50
1
150
2400
5000
8
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
kV
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameters
Output Characteristics
Load Current, Continuous
Maximum Surge Current
Off State Leakage Current
On-State Voltage Drop 1
Off-State dV/dt
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage
Holding Current
Latching Current
Operating Frequency 2
Load Power Factor for
Guaranteed Turn-On 3
Input Characteristics
Input Control Current 4
Input Drop-out Voltage
Input Voltage Drop
Reverse Input Current
Common Characteristics
Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max
Units
VL=120-240Vrms
t < 16ms
VDRM
IL=2AP
IF=0mA
IL
IP
0.1
1000
0.88
-
3
30
100
1.1
-
Arms
AP
AP
VP
V/s
ton
toff
IH
IL
20
5
44
48
-
0.5
0.5
20
5
50
75
500
cycles
cycles
V
V
mA
mA
Hz
60Hz
PF
0.25
-
-
-
f=60Hz, IL=1A Resistive
IF=5mA
VR=5V
IF
VF
IR
0.8
0.9
-
1.2
-
5
1.4
10
mA
V
V
A
-
CI/O
-
-
3
pF
IF = 5 mA
1st half cycle
Subsequent half cycle
-
ILEAK
dV/dt
1
Tested at a peak value equivalent.
2 Zero Cross 1st half cycle @ <100Hz.
3 Snubber circuits may be required at low power factors.
4 For high-noise environments, or for high-frequency operation, use I > 10mA.
F
2
www.ixysic.com
R02
INTEGRATED CIRCUITS DIVISION
CPC1966B
Performance Data (@ 25ºC Unless Otherwise Noted) *
LED Forward Voltage Distribution
(N=50, IF=5mA)
35
25
LED Current to Operate Distribution
(60Hz Resistive Load)
(N=50, VL=120VAC)
20
Zero Cross Voltage Distribution
(N=50, IF=5mA)
25
20
15
10
5
0
1.25
1.26
1.27
1.28
1.29
LED Forward Voltage (V)
20
Device Count (N)
Device Count (N)
Device Count (N)
30
15
10
1.44
1.48
1.52
30
30
25
Device Count (N)
Device Count (N)
1.60
25
20
15
10
4.3
4.6
4.9
5.2
5.5
Zero Cross Voltage (V)
5.8
20
15
10
5
0.88 0.90 0.92 0.94 0.96
SCR Forward Voltage (V)
LED Forward Voltage vs. Temperature
IF=50mA
0
850
852
854
856
858
Blocking Voltage (VP)
LED Current to Operate
vs. Load Frequency
(VL=140Vrms, RL=400:)
2.8
1.6
0.98
LED Current (mA)
1.5
IF=20mA
1.4
1.3
IF=10mA
1.2
3.0
2.4
2.2
2.0
1.8
1.6
1.2
20
40
60
Temperature (ºC)
80
100
ZL=200mH
IL=500mA
2.5
2.0
RL=400:
IL=350mA
1.5
1.0
1.4
IF=5mA
860
LED Current to Operate
(fO=60Hz)
3.5
2.6
LED Current (mA)
0.86
0
4.0
1.64
Typical Blocking Voltage Distribution
(N=50)
35
5
Forward Voltage (V)
1.56
LED Current (mA)
0
-20
5
0
1.40
Typical SCR Forward Voltage Distribution
(N=50, IF=5mA, IL=2A)
1.1
-40
10
5
0
1.30
15
0
100
200
300
400
Load Frequency (Hz)
500
600
0.5
-40
-20
0
20
40
60
Temperature (ºC)
80
100
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
R02
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
CPC1966B
Performance Data (@ 25ºC Unless Otherwise Noted) *
1.00
Voltage Drop (VP)
2
0
-2
0.90
0.85
0.80
-4
0.75
-6
-1.5
0.70
-40
-1.0
-0.5
0.0
0.5
Load Voltage (VP)
1.0
1.5
VL=600V
VL=300V
10
1
-40
-20
0
20
40
60
Temperature (ºC)
80
0
20
40
60
Temperature (ºC)
80
60
50
40
30
20
-40
100
100
920
3.5
880
3.0
840
800
760
720
-40
-20
0
20
40
60
Temperature (ºC)
80
100
80
100
Maximum Load Current
vs. Temperature
Load Current (Arms)
Blocking Voltage (VP)
Leakage Current (nA)
10000
100
-20
Holding Current vs. Temperature
(IF=0mA)
70
Typical Blocking Voltage
vs. Temperature
Leakage Current vs. Temperature
1000
80
IL=3AP
IL=2AP
IL=1AP
0.95
4
Load Current (AP)
Voltage Drop vs. Temperature
(IF=5mA)
Holding Current (mA)
6
Typical Load Voltage vs. Load Current
(IF=5mA)
2.5
2.0
1.5
1.0
-20
0
20
40
60
Temperature (ºC)
80
100
-40
-20
0
20
40
60
Temperature (ºC)
Maximum Surge Current
(non-Repetitive)
(Values Apply to TJ=50ºC Before Surge)
35
Load Current (AP)
30
25
20
15
10
5
0
1
10
100
1000
Time (ms)
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
4
www.ixysic.com
R02
INTEGRATED CIRCUITS DIVISION
CPC1966B
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper
operation of our devices when handled according to the limitations and information in that standard as well as to any
limitations set forth in the information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Rating
CPC1966B
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device
Maximum Temperature x Time
CPC1966B
245ºC for 30 seconds
Board Wash
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.
Cleaning methods that employ ultrasonic energy should not be used.
Pb
R02
RoHS
2002/95/EC
e3
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
CPC1966B
MECHANICAL DIMENSIONS
CPC1966B
21.082 ± 0.381
(0.830 ± 0.015)
Pin 8
16.764 ± 0.381
(0.660 ± 0.015)
3.302 ± 0.051
(0.130 ± 0.002)
0.127 ± 0.076
(0.005 ± 0.003)
15.90
(0.626)
10.160 ± 0.254
(0.400 ± 0.010)
2.00
(0.079)
0.889 ± 0.127
(0.035 ± 0.005)
Pin 1
0.764 ± 0.102
(0.030 ± 0.004)
5.076 ± 0.127
(0.200 ± 0.005)
7.622 ± 0.127
(0.300 ± 0.005)
Recommended PCB Pattern
1.524 typ
(0.060)
1.016 ± 0.127
(0.040 ± 0.005)
1.650 ± 0.102
(0.065 ± 0.004)
5.080 ± 0.127
(0.200 ± 0.005)
0.381 ± 0.025
(0.015 ± 0.001)
Dimensions
Unless Otherwise Noted
mm
(inches)
Note: Tolerances are non-cumulative.
5.076
(0.200)
7.622
(0.300)
5.076
(0.200)
0.95
(0.037)
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its
products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
6
Specification: DS-CPC1966B-R02
©Copyright 2012, IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
6/26/2012