JMK FF-1503-18

FF-1503-18
Operating Voltage = _______________ 125 Vac
Operating Current (Max) = __________ 18 AMP A/C
Frequency = _____________________ 60 HZ
Temp range (Storage) = ____________ -40 to 125oC
Temp range (Oper.) @ 18.0 AMP= ___ -40 to 85oC *
Note: (cooling air may be required)
Dielectric Withstand volt (Ph—Case) = 1500 Vac
Dielectric Withstand volt (Ph—Ph) = __ 1500 Vdc
Leakage current @ 125 V~, 60 HZ = __ 0.3 MA max.
Discharge Voltage after 1.0 sec = ____ 43 V max.
Weight = _______________________ 1300 gr / 2.9 lb.
BRN
BRN
LOAD
LINE
BLU
BLU
GRN/YEL
Order p/n: FF-1503-18
OPERATING CURRENT VS AMBIENT TEMPERATURE
90
80
INSERTION LOSS (db)
OPERATING TEMP (DEG C)
90
80
70
60
70
50
40
30
20
50
CM
60
DM
10
40
0
12.0
13.0
14.0
15.0
16.0
17.0
.01
18.0
.04
.02
.1
.07
1
.7
4
2
10
7
40
20
100
70
FREQUENCY (MEGAHERTZ)
CURRENT (AMPS)
This filter is designed to operate
with forced air cooling.
5.00
6.0 - 7.0
6.0 - 7.0
0.23 - 0.30
0.23 - 0.30
1.25
With a 26 cfm fan supplying cooling
the operating temperature is
85o C.
With a 34 cfm fan supplying cooling
the operating temperature is
90o C.
BROWN
GRN / Y
LOAD
BROWN
LINE
The curve above shows the
operating temperature versus
current in “still air”.
.4
.2
BLUE
LINE
BLUE
LOAD
2.25
1.60
1.12
0.350
2.050
2.75
0.39
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc Glasgow G13 1DN Scotland UK
4.220
10-32 INSERT
4 PLCS
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884
AWG #14
5 PLCS