MAGNETROL B60-2C20-JEE

Flanged External Cage
Float Actuated
Liquid Level Switches
DESCRIPTION
External cage type level switches are completely selfcontained units designed for side mounting to a tank
or vessel with threaded or flanged pipe connections.
In hundreds of industrial applications throughout the
petroleum refining, petrochemical production and
power generation markets, these switches have
thoroughly demonstrated their worth for years.
FEATURES
• Carbon steel float chamber.
• Easy inspection of float chamber through
removable head.
• Stainless steel float and trim.
• Service pressures up to 900 psig (62 bar).
• Process temperatures up to +1000° F (+538° C).
• Specific gravity ratings as low as 0.40.
• Available switch styles including dry contact,
hermetically sealed and pneumatic.
• Operating level differentials field-adjustable.
• Single or multiple switch mechanisms available.
• Available switch enclosures include:
NEMA 1 carbon steel for pneumatics
APPLICATIONS
TYPE 4X/7/9 Class I, Div. 1 Groups C & D aluminum
• Accumulators
• Flash tanks
TYPE 4X/7/9, Class I, Div. 1, Group B, aluminum
• Receivers
• Knockout drums
• 1", 11⁄2", or 2" tank connections available in either
NPT, socket weld, flanged side/side or flanged
side/bottom construction.
• Flare pots
• Storage tanks
• Scrubbers
• Separators
• Optional high temperature insulation available.
See bulletin 41-106.
OPTIONS
• Interface calibration
• Special tank connections
• Extreme temperature modifications
• Special actuation levels
• Customized installation dimensions
• Special exterior surface preparation and finish
TECHNOLOGY
A permanent magnet Πis attached to a pivoted
switch actuator and adjustment screw . As the
float Ž rises following the liquid level, it raises the
attraction sleeve  into the field of the magnet,
which then snaps against the non-magnetic
enclosing tube , actuating the switch ‘. The
enclosing tube provides a static pressure boundary
between the switch mechanism and the process.
On a falling level, an inconel spring retracts the
magnet, deactivating the switch.
2
5
Pivot
6
4
Return
Spring
1
3
Process Liquid
Process Liquid
Rising Level
Falling Level
SPECIFICATIONS
SWITCH
MECHANISMS
AND
ENCLOSURES
SERIES B, C, D & R DRY CONTACT SWITCHES
SERIES F, HS, H1, 8 & 9 HERMETICALLY SEALED SWITCHES
• Dry contact for most applications
• Ideal for use in salt and other
corrosive atmospheres
• Designs for AC and DC
current applications
• Positively pressurized capsules for
entire mechanism and contacts
• Process temperatures
to +1000° F (+538° C)
• Process temperatures
to +1000° F (+538° C)
SERIES J & K PNEUMATIC SWITCHES
SWITCH ENCLOSURES
• Suited for applications where
electrical power is not available
• TYPE 4X/7/9 aluminum enclosures
• Designed to meet Class I, Div. 1,
Groups C & D and Class I, Div. 1
Group B
• Bleed and non-bleed designs
• Process temperatures
to +400° F (+204° C)
• Optional housing heaters and drains
available for some enclosures
• Pneumatic switch mechanisms
available with a NEMA 1 enclosure
BASIC ELECTRICAL RATINGS
Voltage
120 VAC
240 VAC
24 VDC
120 VDC
240 VDC
2
Switch Series and Non-Inductive Ampere Rating
D
F
HS
H1
R
8
B
C
15.00
15.00
6.00
0.50
0.25
15.00
15.00
10.00
1.00
0.50
10.00
—
10.00
10.00
3.00
2.50
—
4.00
0.30
—
5.00
5.00
5.00
0.50
0.25
1.00
1.00
1.00
0.40
—
1.00
1.00
1.00
0.40
—
1.00
—
3.00
—
—
9
—
—
0.50
—
—
AGENCY
APPROVALS
AGENCY
APPROVED MODEL
AREA CLASSIFICATION
FM
All with an electric switch mechanism and a housing
listed as TYPE 4X
Non-Hazardous TYPE 4X
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9
Class I, Div 1, Groups C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9 Class I, Div 1, Group B
Class I, Div 1, Groups B, C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and a
housing listed as CSA TYPE 4X
Non-Hazardous CSA TYPE 4X
All with a Series HS, H1, F, 8 or 9 electric switch
mechanism and a housing listed as CSA TYPE 4X
Class I, Div 2, Groups B, C & D
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9
Class I, Div 1, Groups C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and a housing
listed as TYPE 4X/7/9 Class I, Div 1, Group B
Class I, Div 1, Groups B, C & D
Class II, Div 1, Groups E, F & G
All with an electric switch mechanism and an
ATEX housing Œ
ATEX II 2 G EEx d IIC T6
94/9/EC
IEC Ex Ex d IIC T6
IP 66
Low Voltage Directive 2006/95/EC
Per Harmonized Standard:
EN 61010-1/1993 & Amendment No. 1
Installation Category II
Pollution Degree 2
CSA
ATEX / IEC Ex 
CE
Œ Dual stage units with ‘HS’ or ‘H1’ switches are not ATEX approved.
 IEC Installation Instructions:
The cable entry and closing devices shall be Ex d certified suitable for the conditions of use and correctly installed.
For ambient temperatures above +55° C or for process temperatures above +150° C, suitable heat resistant cables shall be used.
Heat extensions (between process connection and housing) shall never be insulated.
Special conditions for safe use:
When the equipment is installed in process temperatures higher than +85° C the temperature classification must be reduced
according to the following table as per IEC60079-0.
Maximum Process
Temperature
Temperature
Classification
< 85° C
T6
< 100° C
T5
< 135° C
T4
< 200° C
T3
< 300° C
T2
< 450° C
T1
These units are in conformity with IECEx KEM 05.0020X
Classification Ex d IIC T6
Tambient -40° C to +70° C
3
DIMENSIONAL
INCHES
SPECIFICATIONS
(mm)
CHAMBERS WITH 1-INCH CONNECTIONS
INCHES
Min. 1" NPT Threaded
1" Flanged
Sp.
& Socket Weld Upper Side/Bottom
Gr.
A
B
C
A
B
C
MILLIMETERS
1" Flanged
Side/Side
HL
A
B
C
A
B
HL
LL
76
342
325
149
417 341 149 433 74
97
D30 .65
9.19 3.27 12.75 12.06 6.12 15.63 12.71 6.12 16.25 2.50 3.33 233
83
323
306
155
397 322 155 412 63
84
66
84
B60 .68
C60 .55
C
10.19 4.33 14.63 13.06 7.18 17.50 13.71 7.18 18.19
9.81 3.80 14.25 12.68 6.68 17.12 13.33 6.68 17.75
LL
2.61 3.34
3.24 3.98
2.77 3.44
2.87 3.60
A
C
B
C
Actuating
Levels
9.94 3.02 13.50 12.81 5.87 16.44 13.46 5.87 17.06 2.95 3.85 252
L30 .40
B
1" Flanged
Side/Side
C29 .76
J30 .48
A
Actuating 1" NPT Threaded
1" Flanged
Levels
& Socket Weld Upper Side/Bottom
258
109
371
331
182
444 348 182 462
248
96
361
322
169
434 338 169 450
82 101
70
87
72
91
Levels ±0.25" (6 mm)
CHAMBERS WITH 112⁄ -INCH CONNECTIONS
INCHES
Min. 11⁄2" NPT Threaded
11⁄2" Flanged
Sp.
& Socket Weld
Upper Side/Bottom
Gr.
A
B
C
A
B
C
MILLIMETERS
11⁄2" Flanged
Side/Side
B
C
A
B
HL
LL
C29 .76
9.75 3.44 14.38 13.81 6.87 18.38 14.46 6.87 19.06 2.02 2.92 247
87
365
350
174
466 367 174 484 51
74
D30 .65
9.00 3.69 13.12 13.06 7.12 17.19 13.71 7.12 17.88 1.87 2.70 228
93
333
331
180
436 348 180 454 47
68
50
68
66
84
37
54
49
67
J30 .48
L30 .40
B60 .68
C60 .55
A
B
C
Actuating 11⁄2" NPT Threaded
11⁄2" Flanged
11⁄2" Flanged Actuating
Levels
& Socket Weld Upper Side/Bottom Side/Side
Levels
10.00 4.75 15.06 14.06 8.18 19.12 14.71 8.18 19.75
9.62 4.22 14.69 13.68 7.68 18.75 14.33 7.68 19.38
HL
LL
1.97 2.70
2.60 3.34
1.46 2.13
1.93 2.66
A
254
244
120
107
382
373
357
347
207
195
C
A
B
C
485 374 207 501
476 363 195 492
Levels ±0.25" (6 mm)
CHAMBERS WITH 2-INCH CONNECTIONS
INCHES
Min. 2" NPT Threaded
Sp.
& Socket Weld
Gr.
A
B
C
MILLIMETERS
2" Flanged
Upper Side/Bottom
B
C
A
B
C29 .76 10.00 3.56 14.44 13.81 6.87 18.25 14.46 6.87 18.94 2.02 2.97 254
90
366
350
D30 .65
96
336
331
B60 .68
A
HL
A
C60 .55
C
2" Flanged
Side/Side
C
L30 .40
B
Actuating 2" NPT Threaded
2" Flanged
Levels
& Socket Weld Upper Side/Bottom
B
J30 .48
A
2" Flanged
Side/Side
LL
A
8.75 3.81 13.25 13.06 7.12 17.56 13.71 7.12 18.25 1.50 2.33 222
9.74 4.87 15.19 14.06 8.18 19.50 14.71 8.18 20.12
9.38 4.34 14.81 13.68 7.68 19.12 14.33 7.68 19.75
1.60 2.33
2.23 2.97
1.52 2.19
1.99 2.72
C
B
C
Actuating
Levels
HL
LL
174
463 367 174 481 52
75
180
446 348 180 463 38
59
40
59
56
75
38
55
50
69
247
123
385
357
207
495 374 207 511
238
110
376
347
195
485 363 195 501
Levels ±0.25" (6 mm)
4
DIMENSIONAL
INCHES
SPECIFICATIONS
(mm)
3.78
(96)
5.93
(151)
3.78
(96)
5.93
(151)
8.46
(215)
10.12
(257)
8.46
(215)
10.12
(257)
D
D
D
plugged
D
plugged
HL
LL
HL
LL
C
C
A
A
B
B
Threaded and Socket Weld
Side/Bottom Flanged
3.78
(96)
5.93
(151)
Conduit Connections D
Electrical Switches
TYPE 4X/7/9: 1" NPT
Group B:
1" NPT
Pneumatic Switches
1
NEMA 1:
⁄4" NPT
8.46
(215)
10.12
(257)
D
D
plugged
NOTES:
1. Switch actuating levels (HL & LL) are given for minimum specific
gravity conditions. Levels will be lower in the float chamber for
higher specific gravities.
HL
LL
2. Standard process connections are a combination of 1" NPT and
1" socket weld coupling.
C
A
3. Allow overhead clearance of 10 inches (254 mm) for TYPE 4X/7/9
housing.
B
Side/Side Flanged
5
MODEL
NUMBER
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP)
MODEL NUMBER CODE
Œ
Model
No.
C29
D30 Ž
J30
L30
B60
C60
Minimum Specific Gravity 
for Models with
Material of Construction Code
1
2
0.76
0.65
0.48
0.40
0.68
0.55
0.81
0.69
0.51
0.42
0.71
0.59
Pressure Rating
psig @ ° F
bar @ ° C
100
750
900
1000
38
399
482
538
500
250
400 
300 
900
500
403
201
322 
242 
725
403
388
194
310
233
496
388
383
191
167
167
182
182
34
17
28 
21 
62
34
28
14
22 
17 
50
28
27
13
21
16
34
27
26
13
12
12
13
13
MATERIALS OF CONSTRUCTION
1
2
Carbon steel chamber, 316 stainless steel float, 400 stainless steel sleeve
Carbon steel chamber, 316 stainless steel float, 316 stainless steel sleeve
TANK CONNECTION TYPE AND SIZE
1"
Connection Size
11⁄2"
2"
Threaded
Side/Bottom
B20
C20
D20
Socket Weld
Side/Bottom
B30
C30
D30
150
300
Cage Mounting Flange Rating (lbs.)
600
150
300
600
150
300
600
Flanged Upper
Side/Bottom
N30
N40
N50
P30
P40
P50
Q30
Q40
Q50
Flanged
Side/Side
S30
S40
S50
T30
T40
T50
V30
V40
V50
Connection
Type
Connection flanges are ASME B16.5 raised face.
PNEUMATIC SWITCH MECHANISM AND ENCLOSURE
Switch
Description
Series J
Bleed Type
Series K
Non-Bleed
Maximum
Supply
Pressure
psig
bar
Maximum
Process
Temperature
°F
°C
100
60
100
40
+400
+400
+400
+400
7
4
7
3
+204
+204
+204
+204
Bleed
Orifice
Diameter
inches mm
.063
.094
—
—
1.6
2.3
—
—
Models with
Material of Construction
Code 1
Code 2
NEMA 1
NEMA 1
JDG
JEG
KOE
KOG
JDE
JEE
KOE
—
Electric switch mechanism and enclosure codes on next page
ΠModels are limited to maximum temperature rating of selected
switch mechanisms.
 For single stage models only. Consult factory for multiple stages.
Ž Model D30 recommended for Dowtherm applications.
 Float cage rated 600 psig @ +100° F (41 bar @ +38° C) and
340 psig @ +750° F (23 bar @ +399° C).
 Process temperature based on +100° F (+38° C) ambient.
‘ Consult factory for NEMA 4X//9 cast iron housing codes.
’ On condensing applications, temperature down-rated to
+400° F (+209° C) process at +100° F (+38° C) ambient.
6
ELECTRIC SWITCH MECHANISM AND ENCLOSURE
Switch
Description
Series B
Snap Switch
BKA
BLA
BMA
BNA
BOA
CKA
CLA
CMA
CNA
COA
DKB
DLB
BKB
BLB
BMB
BNB
BOB
CKB
CLB
CMB
CNB
COB
DKB
DLB
DMB
DNB
DOB
FKB
FLB
FNB
FOB
HMJ
HMN
HMS
HMY
BKK
BLK
BMK
BNK
BOK
CKK
CLK
CMK
CNK
COK
DKK
DLK
DMK
DNK
DOK
FKK
FLK
FNK
FOK
HMK
HMP
HMT
HMZ
BC9
BD9
BE9
BF9
BG9
CC9
CD9
CE9
CF9
CG9
DC9
DD9
DE9
DF9
DG9
FC9
FD9
FF9
FG9
-40 to +250
(-40 to +121)
-40 to +450
(-40 to +232)
-40 to +250
(-40 to +121)
-50 to +750
(-46 to +399)
Series HS ’
Hermetically Sealed
5-amp Snap Switch
with Wiring Leads
-50 to +550
(-46 to +288)
Series HS ’
Hermetically Sealed
5-amp Snap Switch
with Terminal Block
-50 to +550
(-46 to +288)
Series H1
Hermetically Sealed
1-amp Snap Switch
with Wiring Leads
-50 to +750
(-46 to +399)
Series R
High Temperature
Snap Switch
-40 to +750
(-40 to +399)
Series 8
Hermetically Sealed
Snap Switch
-50 to +750
(-46 to +399)
Series 9
High Temperature
Hermetically Sealed
Snap Switch
-50 to +750
(-46 to +399)
1
HM3
HM4
HA9
HM3
HM4
HA9
1
HM7
HM8
HB9
HM7
HM8
HB9
1
HKJ
HKK
HKJ
HKK
HKN
HKP
RKB
RLB
RNB
ROB
8KB
8LB
8MB
8NB
8OB
9KB
9LB
9MB
9NB
9OB
CS/Aluminum
RKK
RLK
RNK
ROK
8KK
8LK
8MK
8NK
8OK
9KK
9LK
9MK
9NK
9OK
SPDT
DPDT
SPDT
SPDT
DPDT
Series F
Hermetically Sealed
Snap Switch
BCC
BDC
BEC
BFC
BGC
CCC
CDC
CEC
CFC
CGC
DC9
DD9
DNB
DOB
FKA
FLA
FNA
FOA
HMJ
HMN
HMS
HMY
BKJ
BLJ
BMJ
BNJ
BOJ
CKJ
CLJ
CMJ
CNJ
COJ
DKK
DLK
N/A
DNK
DOK
FKJ
FLJ
FNJ
FOJ
HMK
HMP
HMT
HMZ
1
2
3
1
2
1
2
3
1
2
1
2
3
1
2
1
2
1
2
1
2
1
2
SPDT
DPDT
Series D DC Current
Snap Switch
All models with
Material of Construction Code 2
Process 
Temperature
TYPE 4X/7/9 Aluminum Enclosure ‘
Set
Contacts
Range
Points
ATEX
ATEX
°F (°C)
Class I, Div 1 Class I, Div 1
Class I, Div 1 Class I, Div 1
Ex II 2 G EEx
Ex II 2 G EEx
Groups C&D
Group B
Groups C&D
Group B
d IIC T6
d IIC T6
DPDT
Series C
Snap Switch
All models with
Material of Construction Code 1
SPDT
DPDT
SPDT
DPDT
SPDT
SPDT
DPDT
SPDT
DPDT
SPDT
DPDT
-40 to +1000
(-46 to +538)
Series 9 High
Temperature
Hermetically Sealed
Snap Switch
-50 to +1000
(-46 to +538)
SPDT
DPDT
SPDT
DPDT
N/A
N/A
2
HKN
HKP
1
2
1
2
1
2
3
1
2
1
2
3
1
2
RKB
RLB
RNB
ROB
8KA
8LA
8MA
8NA
8OA
9KA
9LA
9MA
9NA
9OA
CS/Aluminum
RKK
RLK
RNK
ROK
8KJ
8LJ
8MJ
8NJ
8OJ
9KJ
9LJ
9MJ
9NJ
9OJ
NEMA 4X
Series R High
Temperature Snap
Switch
DF9
DG9
FCC
FDC
FFC
FGC
1
2
1
2
1
2
3
1
2
R1M
R3M
RDM
REM
9AD
9BD
9CD
9DD
9ED
RC9
RD9
RF9
RG9
8CC
8DC
8EC
8FC
8GC
9CC
9DC
9EC
9FC
9GC
Cast Iron
Class I, Div 1 Class I, Div 1
Groups C&D
Group B
RKM
RKW
RLM
RLW
RNM
RNW
ROM
ROW
9KD
9KV
9LD
9LV
9MD
9MV
9ND
9NV
9OD
9OV
N/A
N/A
NEMA 4X
R1M
R3M
RDM
REM
9AM
9BM
9CM
9DM
9EM
RC9
RD9
RF9
RG9
8C9
8D9
8E9
8F9
8G9
9C9
9D9
9E9
9F9
9G9
Cast Iron
Class I, Div 1 Class I, Div 1
Groups C&D
Group B
RKM
RKW
RLM
RLW
RNM
RNW
ROM
ROW
9KM
9KW
9LM
9LW
9MM
9MW
9NM
9NW
9OM
9OW
7
QUALITY
The quality assurance system in place at
Magnetrol guarantees the highest level of quality
The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment to
throughout the company. Magnetrol is committed
to providing full customer satisfaction both in
known international quality standards providing the strongest assurance of product/service
quality products and quality service.
quality available.
Several Flanged External Cage Level Switches are
available for quick shipment, usually within one
week after factory receipt of a complete purchase
order, through the Expedite Ship Plan (ESP).
ESP service may not apply to orders of ten units
or more. Contact your local representative for
lead times on larger volume orders, as well as
other products and options.
ESP
Expedite
Ship
Plan
To take advantage of ESP, match the color
coded model number codes in the selection
charts (standard dimensions apply).
WARRANTY
All Magnetrol mechanical level and flow controls are warranted free of defects in materials
or workmanship for five full years from the
date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered
under the warranty; then, Magnetrol will repair
or replace the control at no cost to the purchaser
(or owner) other than transportation.
Magnetrol shall not be liable for misapplication,
labor claims, direct or consequential damage or
expense arising from the installation or use of
equipment. There are no other warranties
expressed or implied, except special written
warranties covering some Magnetrol products.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype are registered trademarks of Magnetrol International.
CSA logotype is a registered trademark of Canadian Standards Association
BULLETIN: 46-116.22
EFFECTIVE: August 2010
SUPERSEDES: July 2009