MAKE-PS 200UFR

www.make-ps.com
E-mail:[email protected]
200UFR series
Single & Dual Output
DC/DC Converter
FEATURES
•
•
•
•
•
•
•
Up to 80% Efficiency
1500 VDC Isolation
4:1 Input Range
Low Ripple and Noise
Short Circuit and Over Current Protection
Remote On/Off
Internal SMD construction
DESCRIPTIONS
INPUT CHARACTERISTICS
The 200UFR series are 2 watts power modules designed to
provide low output ripple and wide operating temperature
range of -40oC to +85oC in a low-profile SIP package. The
series consists of 14 models with input voltages of 24V and 48V,
and offers regulated output voltages of 3.3V, 5V, 12V, 15V, ±5V,
±12V and ±15V.
Min Typ Max Unit/Comments
Input Voltage
24 VDC Input Models
VDC
24 36
9
48 VDC Input Models
VDC
18 48 75
Input Fuse Requirements
24 VDC Input Models
mA; Slow blow type
350
48 VDC Input Models
mA; Slow blow type
135
Start Voltage
VDC
9
7
Under Voltage Shutdown
VDC
9
6
Remonte On
VDC
0.6
Remote Off
VDC
2.7
Control Input Current (ON)
mA
1
Control Input Current (OFF)
mA
1
Input Filter
Pi Filter
The 200UFR are ideal for datacom, mobile battery driven
equipment,
distributed
power
architectures,
telecommunication equipment, mixed analog/digital
subsystems, automatic test instrumentation and industrial robot
systems.
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Line Regulation
Load Regulation
Ripple/Noise
Overload Protection
Short Circuit Protection
Temperature Coefficient
Min Typ Max Unit/Comments
±2.0 % Output voltage at
nominal line & FL
±0.2 ±0.5 % Output voltage
measured from
min. input line to
maximum
±0.75 % Output voltage
measured from FL
to 25% load
75 mV p-p, Over Line,
Load & Temp., 20
MHz B.W., 25% to
100% FL
see Note 1
see Note 1
±0.01 ±0.02 % per degree C
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
300
VDC, 1 minute
1500
Mohm, 500VDC
1000
250 500 pF, 100kHz, 1Volt
Million Hours,
1
+25oC, Ground
Benign
Note 1: Overload time should be limited to 10 sec and/or the
temperature should be maintained <85oC
>> B-37
www.make-ps.com
E-mail:[email protected]
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Min
-40
-40
Typ Max
+85
+105
95
Cooling
PHYSICAL CHARACTERISTICS
Unit/Comments
C; Ambient
o
C
% Humidity; noncondensing
Free-Air Convection
o
Unit/Comments
1.02 X 0.36 X 0.49 inches
(25.95 X9.25 X 12.45 mm)
Non-Conductive Black Plastic
UL94V-0
6.5 Grams
Case Size
Case Material
Flammability
Weight
OUTLINE DRAWING
SIDE VIEW
0.49
(12.45)
0.13 (3.2)
0.08 (2.03)
0.1(2.54)
0.1(2.54)x8 = 0.8(20.32)
0.36 (9.25)
1.02 (25.95)
0.012(0.3) PIN
7 PLACES
BOTTOM VIEW
1
2
3
6
7
8
9
0.114 (2.9)
0.02(0.5) PIN
7 PLACES
PIN OUT CHART
Pins
1
2
3
6
7
8
9
SINGLE
DUAL
- V in
- V in
+ V in
+ V in
Remote On/Off Remote On/Off
+ V out
+V out
NC
COMMON
NC
NC
- V out
- V out
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
Tolerances
Inches
mm
X.XX = ±0.01
X.X = ±0.25
X.XXX= ±0.005
X.XX = ±0.13
Pin :
±0.002
±0.05
NC = No Connection
>> B-38
www.make-ps.com
E-mail:[email protected]
HOW TO ORDER
HOW TO ORDER
2 15
D XX UFR - Y
Wattage
Output Voltage
Output
Configuration
(S=Single, D=Dual)
ROHS Compliant
Series
Nominal
Input Voltage
MODEL SELECTION CHART
Model
203S24UFR
205S24UFR
212S24UFR
215S24UFR
203S48UFR
205S48UFR
212S48UFR
215S48UFR
205D24UFR
212D24UFR
215D24UFR
205D48UFR
212D48UFR
215D48UFR
Nominal
Input Voltage
(VDC)
24
24
24
24
48
48
48
48
24
24
24
48
48
48
Input
Voltage
Range
(mA)
9 - 36
9 - 36
9 - 36
9 - 36
18 - 75
18 - 75
18 - 75
18 - 75
9 - 36
9 - 36
9 - 36
18 - 75
18 - 75
18 - 75
Output
Voltage
(VDC)
3.3
5
12
15
3.3
5
12
15
±5
±12
±15
±5
±12
±15
Full Load
Output
Current
(mA)
500
400
167
134
500
400
167
134
±200
±83
±67
±200
±83
±67
No Load
Input
Current
(mA)
20
20
20
20
15
15
15
15
20
20
20
15
15
15
Full Load
Input
Current
(mA)
97
110
106
105
49
58
54
54
144
108
106
60
55
55
Efficiency
(%)
Full Load
71
76
79
80
70
72
78
78
73
77
79
70
76
76
>> B-39
www.make-ps.com
E-mail:[email protected]
DERATING CURVES
MODEL 200UFR
Pout %
100
90
80
70
60
50
40
30
20
10
0
-40
400LFM
100LFM
Natural
Convection
50
60
200LFM
70
80
90
100
110
TEMPERATURE ° C
>> B-40