A P V- 1 6 16W Single Output Switching Power Supply series Features : Constant voltage design Universal AC input / Full range Protections: Short circuit / Over current / Over voltage Fully isolated plastic case Cooling by free air convection Small and compact size Pass LPS Suitable for LED lighting and moving sign applications 100% full load burn-in test Low cost, high reliability 2 years warranty F SPECIFICATION MODEL OUTPUT APV-16-5 APV-16-12 APV-16-15 5V 12V 15V 24V RATED CURRENT 2.6A 1.25A 1A 0.67A CURRENT RANGE 0 ~ 2.6A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.67A RATED POWER 13W 15W 15W 16.08W 120mVp-p 120mVp-p 150mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE TOLERANCE Note.3 5.0% LINE REGULATION 1.0% SETUP, RISE TIME VOLTAGE RANGE 20ms/230VAC Note.4 90 ~ 264VAC 76% 80% AC CURRENT INRUSH CURRENT(max.) 0.3A/230VAC 0.5A/115VAC COLD START 35A/115VAC 70A/230VAC LEAKAGE CURRENT 0.25mA / 240VAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT NOTE 127 ~ 370VDC EFFICIENCY (Typ.) PROTECTION OTHERS 1500ms,30ms / 115VAC at full load 47 ~ 63Hz 81% Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16V 17.5 ~ 21V 27.6 ~ 32.4V Protection type : Shut off o/p voltage, clamping by zener diode -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +80 , 10 ~ 95% RH VIBRATION SAFETY STANDARDS Design refer to TUV EN60950-1, EN61347-2-13,UL8750 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3 ISOLATION RESISTANCE EMC EMISSION 83% Above 105% rated output power 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes EMC IMMUNITY MTBF APV-16-24 12ms/115VAC at full load FREQUENCY RANGE OVER CURRENT EMC LPS 2.0% Note.6 1500ms, 30ms / 230VAC HOLD UP TIME (Typ.) SAFETY & SELV DC VOLTAGE LOAD REGULATION INPUT 110 Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A DIMENSION 1145.7K hrs min. MIL-HDBK-217F (25 ) 77*40*29mm (L*W*H) PACKING 0.1Kg; 120pcs/14Kg/0.93CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:APV-16-SPEC 2011-07-09 A P V- 1 6 16W Single Output Switching Power Supply Mechanical Specification series Unit:mm 90 82.5 77 150 10 UL1569 18AWG AC/N(Blue) AC/L(Brown) 15.5 40 19 +V(Red) -V(Black) 31 UL1569 20AWG T case 150 10 29 T case: Max. Case Temperature Block Diagram I/P fosc : 67KHz EMI FILTER POWER SWITCHING RECTIFIERS RECTIFIERS & FILTER +V -V DETECTION CIRCUIT PWM CONTROL Derating Curve Static Characteristics 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 200 210 220 230 240 250 264 INPUT VOLTAGE (VAC) 60Hz File Name:APV-16-SPEC 2011-07-09