MEANWELL LPV-60-15

L P V- 6 0
60W Single Output Switching Power Supply
series
Features :
Constant voltage design
Universal AC input / Full range
Epoxy encapsulated with IP67 level
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case
Cooling by free air convection
UL1310 Class 2 power unit, pass LPS
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty
LPS IP67
SPECIFICATION
MODEL
OUTPUT
( except for 5V,48V )
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
8A
5A
4A
2.5A
1.67A
1.25A
CURRENT RANGE
0 ~ 8A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 1.67A
0 ~ 1.25A
RATED POWER
40W
60W
60W
60W
60W
60W
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3
8.0%
LINE REGULATION
1.0%
SETUP, RISE TIME
2.0%
Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)
50ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT
INRUSH CURRENT(max.)
1.2A/115VAC 1A/230VAC
COLD STAR 30A/115VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER CURRENT
Note.4
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
LPV-60-48
5.0%
6.0%
LOAD REGULATION
INPUT
( for 48V only)
16ms/115VAC at full load
83%
83%
86%
86%
86%
41.4 ~ 48.6V
55.2 ~ 64.8V
60A/230VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(except for 5V,48V), IP67 approved, design refer to TUV EN60950-1, EN61347-2-13
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
732Khrs min. MIL-HDBK-217F (25 )
162.5*42.5*32mm (L*W*H)
0.4Kg; 32pcs/13.8Kg/0.56CUFT
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:LPV-60-SPEC 2008-12-16
L P V- 6 0
60W Single Output Switching Power Supply
Mechanical Specification
Case No. 976A
162.5
600
series
Unit:mm
600
18AWG
3.6
16AWG
42.5
3.6
3.5
AC/L(Brown)
AC/N(Blue)
3.5
3.5
+V(Red)
-V(Black)
32
3.5
Block Diagram
fosc : 65KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
Ta=25
100
100
230VAC
90
80
80
70
115VAC
LOAD (%)
LOAD (%)
60
40
20
-30
-15
0
15
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPV-60-SPEC 2008-12-16