MEANWELL LPV-60-5

L P V- 6 0
60W Single Output Switching Power Supply
series
Features :
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.8)
Fully isolated plastic case
Class
power unit, no FG
Pass LPS
Suitable for LED lighting and moving sign applications (Note.7)
100% full load burn-in test
Low cost, high reliability
2 years warranty
LPS IP67
SPECIFICATION
MODEL
OUTPUT
LPV-60-5
LPV-60-12
LPV-60-15
LPV-60-24
LPV-60-36
5V
12V
15V
24V
36V
48V
RATED CURRENT
8A
5A
4A
2.5A
1.67A
1.25A
CURRENT RANGE
0 ~ 8A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 1.67A
0 ~ 1.25A
RATED POWER
40W
60W
60W
60W
60W
60W
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3
8.0%
LINE REGULATION
1.0%
SETUP, RISE TIME
VOLTAGE RANGE
50ms/230VAC
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
1.2A/115VAC 1A/230VAC
COLD START 30A/115VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
83%
83%
86%
86%
86%
41.4 ~ 48.6V
55.2 ~ 64.8V
60A/230VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, UL1310 Class 2(except for LPV-60-5), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1, EN61347-2-13
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
2.0%
Note.4 90 ~ 264VAC
PROTECTION
OTHERS
5.0%
6.0%
OVER CURRENT
EMC
LPV-60-48
Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
HOLD UP TIME (Typ.)
SAFETY &
( except for 5V,48V )
DC VOLTAGE
LOAD REGULATION
INPUT
( for 48V only)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
732Khrs min. MIL-HDBK-217F (25 )
162.5*42.5*32mm (L*W*H)
0.4Kg; 32pcs/13.8Kg/0.56CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. In the European market this product is only suitable for LED lighting applications that don't have to comply with the harmonic current requirements of
EN61000-3-2 Class C.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
File Name:LPV-60-SPEC 2011-06-24
L P V- 6 0
60W Single Output Switching Power Supply
Mechanical Specification
Case No. 976A
162.5
600 30
series
Unit:mm
600 30
3.5
3.6
42.5
15
UL1015 18AWG
AC/N(Blue)
AC/L(Brown)
3.6
81.5
T case
3.5
3.5
UL1007 16AWG
+V(Red)
-V(Black)
3.5
32
T case: Max. Case Temperature.
Recommend Mounting Direction
Block Diagram
fosc : 65KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
230VAC
90
80
80
70
115VAC
LOAD (%)
LOAD (%)
60
40
20
-30
-15
0
15
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPV-60-SPEC 2011-06-24