MEANWELL CLC-60

CLG Series
6 0~ 240W S ingle O utput w ith P FC
Features
NEW
• Universal AC input / Full range
• Protections: Short circuit / Overload / Over voltage / Over
temperature
A
• Built-in active PFC function, PF>0.9 for 75% of load or higher
B
C L G- 1 0 0
(IP67)
C L G -6 0
(I P 6 7 )
INPUT
C
C L G- 1 5 0 A ( IP6 5 )
C L G- 2 4 0 A ( IP6 5 )
OUTPUT
Blank
CLG-150 / 240
• IP67 / IP65 design for indoor or outdoor installations (exclude C type)
• OCP point adjustable through output cable or internal potential meter
(CLG-150 / 240)
• UL1310 class2 power unit (CLG-60&100)
• Cooling by free air convection
• Suitable for LED lighting and moving sign applications
• Optional model for CLG-150 / 240:
A-Type: IP65 rated. Output and constant current level can be adjusted
through internal potential meter
B-Type: IP67 rated and constant current level adjustable through
output cable (optional)
C-Type: Terminal block for I/O connection (optional)
Blank-Type: IP67 rated, cable for I/O connection (optional)
• 3 years warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
Mo d el N o .
AC i n p u t vo l tag e r ange
AC i n r u sh cu r r en t (max.)
CLG-60
CLG-100
90~264VAC; 127~370VDC
Cold start, 40A at 230VAC
CLG-150 NEW
90~280VAC; 127~396VDC
Cold start, 65A at 230VAC
DC ad j u stmen t r an ge
Fixed. Can be modified between ±10% (CLG-60) or
0~-15% (CLG-100) rated output voltage
A and C type can be adjusted by internal potential meter
Fixed. Can be modified between 75%~103% rated
output current
95%~130% constant
95%~102% constant
Cu r r en t ad j u stmen t range
Over l o ad p r o tecti o n
Setup, rise, and hold up time
Output
UL rated, 18AWGx2C (30cm)
B type: 14AWGx2C (30cm)+18AWGx2C (30cm)
172x 61.5x 39
957A
16pcs / 14.8kg
C type: Terminal block
222x 68x 39
954A
12pcs / 13kg
222x 68x 39
954A
12pcs / 13kg
60W (Class 2)
Model No.
Output
Tol.
R&N
CLG-60-12
12V, 0~5.0A
±10%
2.0V
83.0%
CLG-60-15
15V, 0~4.0A
±10%
2.4V
84.5%
11463
CLG-60-20
20V, 0~3.0A
±10%
1.8V
86.5%
11464
CLG-60-24
24V, 0~2.5A
±10%
2.7V
86.5%
11465
CLG-60-27
27V, 0~2.3A
±10%
2.7V
87.0%
11466
CLG-60-36
36V, 0~1.7A
±10%
3.6V
87.0%
11467
CLG-60-48
48V, 0~1.3A
±10%
4.6V
88.0%
96W (Class 2)
Model No.
CLG-100-12
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
Tol.
±3%
±3%
±3%
±3%
±3%
±2%
±2%
R&N
150mV
150mV
150mV
150mV
150mV
150mV
200mV
Stock No.
11651
11652
11653
11654
11655
11656
11657
Effi.
83%
85%
87%
87%
87%
87%
87%
NEW
Model No.
CLG-240-12 A
CLG-240-15 A
CLG-240-20 A
CLG-240-24 A
CLG-240-30 A
CLG-240-36 A
CLG-240-48 A
CLG-150
Output
Tol.
R&N
12V, 0~11.0A
±2%
150mV
15V, 0~9.50A
±2%
150mV
20V, 0~7.50A
±2%
150mV
24V, 0~6.30A
±1%
150mV
30V, 0~5.00A
±1%
150mV
36V, 0~4.20A
±1%
150mV
48V, 0~3.20A
±1%
200mV
B, C or blank (optional model s )
240W
CLG-100
Output
12V, 0~5.00A
15V, 0~5.00A
20V, 0~4.80A
24V, 0~4.00A
27V, 0~3.55A
36V, 0~2.65A
48V, 0~2.00A
NEW
Stock No.
Model No.
11621
CLG-150-12 A
11622
CLG-150-15 A
11623
CLG-150-20 A
11624
CLG-150-24 A
11625
CLG-150-30 A
11626
CLG-150-36 A
11627
CLG-150-48 A
□ = A (standard model) ,
Effi.
11461
244x 68x 39
---------
150W
CLG-60
11462
Stock No.
11471
11472
11473
11474
11475
11476
11477
EN61347-2-13 approved (CLG-240 pending)
EN55015, EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61547
UL rated, 18AWGx3C (30cm)
UL rated, 18AWGx3C (30cm); Terminal block for C t y pe opt i on
A & Blank type: 14AWGx2C (30cm)
Dimen si o n (L * W * H )(mm)
Case N o .
Packi n g
Stock No.
UL60950-1, UL1012, TUV EN60950-1, EN61347-1,
I nput
EM C stan d ar d s
Con n ecti o n
Can be adjusted by internal potential meter (A and C type) or through
output cable (B type)
95%~108% constant current limiting, auto-recovery
current, auto-recovery
107%~135%
110%~140% rated output voltage
1200ms, 80ms, 60ms at
1500ms, 150ms,
3000ms, 80ms, 20ms at full load and 230VAC
full load and 230VAC
no hold up time
I/P-O/P: 4.25kVDC
I/P-O/P: 3.75kVAC, I/P-FG: 1.88kVAC, O/P-FG: 0.5kVAC
-30~+70 O C (refer to output derating curve)
UL1310 Class 2, EN61347-1, EN61347-2-13, CAN/
CSA-C22.2 No.223-M91 (except for 48V) approved,
TUV EN60950-1 & UL879 (SAM list) also for CLG-100
Safety stan d ar d s
NEW
current, auto-recovery
110%~140%
Over vo l tag e p r o tection
With stan d vo l tag e
Wo r ki n g temp er atu re
CLG-240
Output
12V, 0~18.0A
15V, 0~15.0A
20V, 0~12.0A
24V, 0~10.0A
30V, 0~8.00A
36V, 0~6.70A
48V, 0~5.00A
Tol.
±2%
±2%
±1%
±1%
±1%
±1%
±1%
CLG-240
R&N
150mV
150mV
150mV
150mV
150mV
150mV
200mV
□ = A (standard model) , B, C or blank (optional model s )
31
Effi.
88%
88%
90%
90%
90%
89%
90%
Effi.
90%
90%
92%
92%
92%
93%
93%