MEANWELL LPC-20-350

LPC-20
20W Single Output Switching Power Supply
series
Features :
Constant current design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Over voltage
Cooling by free air convection
Small and compact size
Fully encapsulated with IP67 level (Note.7)
Fully isolated plastic case
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
LPS IP67
SPECIFICATION
MODEL
LPC-20-350
LPC-20-700
RATED CURRENT
350mA
700mA
DC VOLTAGE RANGE
9 ~ 48V
9 ~ 30V
RATED POWER
16.8W
21W
RIPPLE & NOISE (max.) Note.2 200mVp-p
OUTPUT
VOLTAGE TOLERANCE Note.3
5.0%
CURRENT ACCURACY
5.0%
LINE REGULATION
1.0%
INPUT
200mVp-p
Note.6 500ms, 250ms / 230VAC
50ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4 90 ~ 264VAC
500ms, 250ms / 115VAC at full load
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
83%
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
0.55A/115VAC 0.35A/230VAC
COLD START 35A/115VAC
70A/230VAC
LEAKAGE CURRENT
PROTECTION OVER VOLTAGE
0.25mA / 240VAC
50.4 ~ 60V
31.5 ~ 40.5V
Protection type : Shut off o/p voltage, clamping by zener diode
(Refer to "Derating Curve")
WORKING TEMP.
-30~ +70
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
-40 ~ +80
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL879, UL1310 , CSA C22.2 No. 207-M89(except for LPC-20-350), CAN/CSA C22.2 No. 223-M91(except for LPC-20-350),
IP67 approved ; design refer to TUV EN60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3KVAC
EMC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
( except for 350mA )
2.0%
LOAD REGULATION
SETUP, RISE TIME
( for 350mA only)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
786.5Khrs min. MIL-HDBK-217F (25 )
118*35*26mm (L*W*H)
0.22Kg; 60pcs/14.2Kg/0.62CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:LPC-20-SPEC 2012-03-20
LPC-20
20W Single Output Switching Power Supply
Mechanical Specification
Case No. 972A
600 30
118
series
Unit:mm
600 30
UL1015 18AWG
17
UL1015 18AWG
+V(Red)
-V(Black)
28
2-
3.6
35
T case
3.5
AC/N(Blue)
AC/L(Brown)
3.5
3.5
3.5
26
T case: Max. Case Temperature.
Recommend Mounting Direction
Block Diagram
fosc : 60KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
O.C.P.
O.L.P.
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-15
0
15
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPC-20-SPEC 2012-03-20