MEANWELL NED-100C

NED-100
100W Dual Output Switching Power Supply
series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
2 years warranty
SPECIFICATION
NED-100A
MODEL
CH2
CH1
CH2
CH1
CH2
CH1
DC VOLTAGE
5V
12V
5V
24V
12V
5V
24V
5V
RATED CURRENT
10A
4.2A
8A
2.5A
7A
3A
3.5A
3A
0.7 ~ 7.0A
1 ~ 10A
0.3 ~ 3.5A
0 ~ 8A
0 ~ 3A
0 ~ 4A
0 ~ 3A
Note.6 2 ~ 10A
100.4W
RATED POWER
INPUT
NED-100D
CH1
CURRENT RANGE
OUTPUT
NED-100C
NED-100B
OUTPUT NUMBER
100W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
80mVp-p
VOLTAGE ADJ. RANGE
200mVp-p
CH1: 4.75 ~ 5.5V
2.0%
8.0%
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
10%
99W
99W
120mVp-p
80mVp-p
CH1: 11.4 ~ 13.2V
2.0%
3.0%
120mVp-p
CH2
80mVp-p
CH1: 22.8 ~ 26.4V
2.0%
3.0%
LINE REGULATION
Note.4
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
Note.5
1.0%
5.0%
1.0%
4.0%
1.0%
2.0%
1.0%
2.0%
SETUP, RISE TIME
2000ms, 30ms/230VAC
HOLD TIME (Typ.)
25ms/230VAC
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch
FREQUENCY RANGE
EFFICIENCY (Typ.)
47 ~ 63Hz
80%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2A/115VAC
1.2A/230VAC
COLD START 45A
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
1200ms, 30ms/115VAC at full load
20ms/115VAC at full load
248 ~ 373VDC
80%
82%
82%
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH2: 5.75 ~ 6.75V
CH1: 13.8 ~ 15.8V
CH1: 5.75 ~ 6.75V
CH2: 27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on Ch1 output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 7)
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024,EN61000-6-1,light industry level, criteria A
MTBF
320.7K hrs min. MIL-HDBK-217F (25
199*98*38mm (L*W*H)
0.55Kg; 30pcs/17.5Kg/0.97CUFT
DIMENSION
PACKING
NOTE
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:NED-100-SPEC 2008-09-25
NED-100
100W Dual Output Switching Power Supply
Mechanical Specification
Case No. 902
series
Unit:mm
7
3.5
9
12
197
1
9.5
2
98
80
4
85.5
3
8.2
5
6
7
3.5
4-
+V ADJ.
M
3
57.5
4.5
120
199
190
3.5
38
3
28.5
18
18
9
3.5
3-M
Pin No.
1
2
3
Pin No.
Assignment
DC OUTPUT +V2
5
4,6
DC OUTPUT COM
DC OUTPUT +V1
7
Assignment
AC/L
AC/N
FG
157
22
fosc : 55KHz
Block Diagram
230
115
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
Terminal Pin No. Assignment
9.5
6.5
POWER
SWITCHING
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
+V1
COM
DETECTION
CIRCUIT
FG
CONTROL
O.L.P.
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
100
90
80
80
70
70
LOAD (%)
LOAD (%)
60
40
20
-20
-10
0
10
20
30
40
AMBIENT TEMPERATURE ( )
50
60
(HORIZONTAL)
60
50
40
88
176
95
190
100
200
115
230
120
240
132
264
INPUT VOLTAGE (VAC) 60Hz
File Name:NED-100-SPEC 2008-09-25