D-60 60W Dual Output Switching Power Supply series Features : Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on Fixed switching frequency at 54KHz 2 years warranty SPECIFICATION MODEL OUTPUT INPUT D-60A CH1 CH2 CH1 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 4A 3A 3A 1.8A CURRENT RANGE 0.3 ~ 6A 0.2 ~ 4A 0.3 ~ 6A 0.2 ~ 2.2A RATED POWER 56W RIPPLE & NOISE (max.) Note.2 75mVp-p NOTE CH1 : 4.75 ~ 5.5V 2.0% 6.0% 150mVp-p 5.0% 0.5% 1.0% 0.5% 0.5% LOAD REGULATION 0.5% 4.0% 0.5% 4.0% SETUP, RISE TIME 300ms, 50ms / 230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 73% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1A/230VAC COLD START 20A/115VAC LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. OVER VOLTAGE 5V : 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed. VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE OTHERS 75mVp-p LINE REGULATION WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT (Note 4) 150mVp-p CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% WORKING TEMP. EMC CH2 58W VOLTAGE ADJ. RANGE PROTECTION SAFETY & D-60B OUTPUT NUMBER 800ms, 50ms / 115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC 76% 40A/230VAC -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 / 70% RH EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF DIMENSION 301.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) PACKING 0.54Kg; 24pcs/13.8Kg/0.75CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:D-60-SPEC 2010-10-18 D-60 60W Dual Output Switching Power Supply Mechanical Specification Case No. 901 series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2-M 6 97 65 9.5 2 3 7 3.5 4.5 78 24 159 150 22 Pin No. 1 2 3 38 3.5 M3 28.5 3.5 3- Terminal Pin No. Assignment 18 18.5 9 9 6.5 Assignment AC/L AC/N FG Pin No. 4 5 6,7 Assignment DC OUTPUT +V2 DC OUTPUT +V1 DC OUTPUT COM 117 Block Diagram fosc : 54KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. PWM CONTROL O.V.P. Derating Curve Static Characteristics (B) Ta=25 100 OUTPUT VOLTAGE (V) 60 LOAD (%) 300 +5V 80 40 20 -10 -10 5.2 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 24 5.0 250 +24V 23 4.8 200 22 4.6 150 21 4.4 100 20 4.2 19 4.0 +24V +5V 60 80 100 120 140 160 180 200 220 240 50 OUTPUT RIPPLE (mVp-p) 25 25 260 INPUT VOLTAGE (V) 60Hz File Name:D-60-SPEC 2010-10-18