Q-60 60W Quad Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on Fixed switching frequency at 35KHz 2 years warranty SPECIFICATION OUTPUT CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V RATED CURRENT 5.5A 2A 0.5A 0.5A 5.5A 1.5A 0.5A 0.5A 4A 1A 1A 0.5A CURRENT RANGE 0.5 ~ 8A 0.1 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.1 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.1 ~ 3A 0.1 ~ 1.5A 0 ~ 1A RATED POWER 60W +8,-4% 5.0% 0.5% 0.5% 2.0% 0.5% 0.5% 0.5% 1.0% 2.0% 0.5% LOAD REGULATION 0.5% 4.0% 1.0% 1.0% 0.5% 4.0% 1.0% 1.0% 0.5% 4.0% 4.0% 1.0% 800ms, 20ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 5.0% 5.0% 1600ms, 20ms/115VAC at full load 15ms/115VAC at full load 120 ~ 370VDC EFFICIENCY (Typ.) 70% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 0.8A/230VAC COLD START 15A/115VAC 30A/230VAC 72% LEAKAGE CURRENT <1mA / 240VAC OVERLOAD 105 ~ 150%/115VAC rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE NOTE 5.0% CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% SETUP, RISE TIME 5.0% CH1: 4.75 ~ 5.5V 2.0% +8,-4% 1.0% WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT OTHERS CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% WORKING TEMP. (Note 4) 62W LINE REGULATION OVER VOLTAGE EMC 60W CH4 RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 150mVp-p 120mVp-p VOLTAGE ADJ. RANGE PROTECTION SAFETY & Q-60D OUTPUT NUMBER VOLTAGE TOLERANCE Note.3 INPUT Q-60C Q-60B MODEL 75% 5V: 5.75 ~ 6.75VDC Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A EMS IMMUNITY MTBF 284.8K hrs min. MIL-HDBK-217F (25 ) DIMENSION 159*97*38mm (L*W*H) 0.56Kg; 24pcs/14.4Kg/0.75CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:Q-60-SPEC 2008-03-10 Q-60 60W Quad Output Switching Power Supply Mechanical Specification Case No. 901 4.5 series Unit:mm 3.5 7 152.5 1 8.25 2 65 3 5 6 2-M 7 7 97 84.5 4 3 8 3.5 4.5 78 24 159 150 6.5 22 Pin No. 1 2 3 4 38 M3 3.5 28.5 9 3.5 3- 18 18.5 9 Terminal Pin No. Assignment Assignment AC/L AC/N FG DC OUTPUT V3 Pin No. 5 6 7 8 Assignment DC OUTPUT -V4 DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 117 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P FG RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER POWER SWITCHING O.L.P. REGULATOR -V4 REGULATOR V3 fosc : 35KHz +V2 +V1 COM DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics Ta=25 100 OUTPUT VOLTAGE (V) 12 80 LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 (VERTICAL) 55 (HORIZONTAL) 11 +12V 5.2 5.0 4.8 -5V -12V +5V 300 250 +5V +12V -5V 200 10 4.6 150 9 4.4 100 8 4.2 50 7 4.0 25 -12V 60 80 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) 13 260 INPUT VOLTAGE (V) 60Hz File Name:Q-60-SPEC 2008-03-10